Asymmetric Saturated 3-Stage Doherty Power Amplifier Using Envelope Tracking Technique for Improved Efficiency (효율 향상을 위해 포락선 추적 기술을 이용한 비대칭 포화 3-Stage 도허터 전력 증폭기)

  • Kim, Il-Du;Jee, Seung-Hoon;Moon, Jung-Hwan;Son, Jung-Hwan;Kim, Jung-Joon;Kim, Bum-Man
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.813-822
    • /
    • 2009
  • We have investigated operation of a 1:2:2 asymmetric 3-stage Doherty PA(Power Amplifier) and implemented using the Freescale's 4 W, 10 W PEP LDMOSFETS at 1 GHz. By employing the three peak efficiency characteristics, compared to the two peak N-way Doherty PA, the asymmetric 3-stage Doherty can overcome the serious efficiency degradation along the backed-off output power region and maximize the average efficiency for the modulation signal. To maximize the efficiency characteristic, the inverse class F PA has been designed as carrier and peaking amplifiers. Furthermore, to extract the proper load modulation operation, the adaptive gate bias control signal has been applied to the two peaking PAs based on the envelope tracking technique. For the 802.16e Mobile WiMAX(World Interoperability for Microwave Access) signal with 8.5 dB PAPR(Peak to Average Power Ratio), the proposed Doherty PA has shown 55.46 % of high efficiency at an average output power of 36.85 dBm while maintaining the -37.23 dB of excellent RCE(Relative Constellation Error) characteristic. This is the first time demonstration of applying the saturated PA and adaptive gate bias control technique to the asymmetric 3-stage Doherty PA for the highly efficient transmitter of the base-station application.

Correlation Between Left Ventricular Peak Systolic Pressure/End-Systolic Volume Ratio and Symptomatic Improvement with Valve Replacement in Patients with Aortic Regurgitation and Enlarged End-Systolic Volume (대동맥판역류증과 좌심실수축말기용적 확장이 있는 환자에서 좌심실최고수축기압/수축말기용적비와 판막치환후의 증상적 호전과의 관계)

  • Kim, Woong-Han;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.867-874
    • /
    • 1996
  • This study was designed to assess the left ventricular peak systolic pressure/end-systolic volume (PSP/ESV) ratio in predicting symptomatic improvement with valve replacement in patients with aortic regurgitation and enlarged left von'lrlcular volume. We studied 21 patients (15 men and 6 women aged 15 to 60 years) with moderate or severe aortic regur- gitation, no other cardiovascular abnormalities and left ventricular end-systolic volume over 60 m11m2. In this group we assessed the preoperative variables which routinely were measured at cardiac catheterlzation to predict symptomatic improvement with valve replacement. Six months after operation, symptoms were alleviated in 13 patients(62%), and unchanged in 8()8%). By multivariate analysis, the PSP/ESV rati was a strong predictor for functional class 6 months after surgery(p=0.005) and also for change- in functional class prior to an operation to 6 months postoperatively(p=0.0)2). By 6 months after receiving valve replacement, all patients with a ratio over 1. 71 mmHglml/m'were in functional class I or II , in contrast, of those with a ratio < 1.71 mmHg/ml/m2, 40% were in functional class III. The PSP/ESV ratio may help to predict which patients with aortic regurgitation and enlarged left ven- tricular end-systolic volume will have symptomatic improvement with valve replacement.

  • PDF

Clinical Evaluation of Tooth Mobility Following Root Planing and Flap Operation (치근활택술과 치은박리소파술 후 치아동요도 변화에 관한 연구)

  • Pang, Eun-Kyoung;Chai, Jung-Kiu;Kim, Chong-Kwan;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.4
    • /
    • pp.893-914
    • /
    • 1999
  • Tooth mobility may be the decisive factor that determines whether dental treatment of any kind is undertaken. Although tooth mobility in isolation says little in itself, the finding of increased tooth mobility is of both diagnostic and prognostic importance. Only the detection of an increase or decrease in mobility makes an evaluation possible. Thus prior to treatment, we must understand the pathologic process causing the observed the tooth mobility and decide whether the pattern and degree of observed tooth mobility is reversible or irreversible. And then it must be decided whether retention and treatment or extraction and replacement. The purpose of this study was to compare tooth mobility at different time period during root planing and flap operation and to relate changes in mobility to each treatment method. Twenty-one patients (287 teeth) with chronic adult periodontitis were treated with root planing(control group) and flap operation(experimental group), and each group was divided 3 subgroups based upon initial probing pocket depth (1-3mm, 4-6mm, 7mm and more). Tooth mobility was measured with $Periotest^{(R)}$ at the day of operation, 4 days, 1 week, 2 weeks, 3 weeks, 4 weeks, 8 weeks, 12 weeks after each treatment. Tooth mobility, attachment loss, radiographic bone loss, and bleeding on probing were measured at the day of operation, 4 weeks, 8 weeks and 12 weeks after treatment. 1. In group initial probing depth was 1-3mm, tooth mobility had no significant difference after root planing and flap operation. 2 . In group initial probing depth was 4-6mm, 7mm and more, tooth mobility had decreased in 12 weeks after root planing(p<0.01). And the mobility had increased after flap operation(p<0.01) and was at peak in 1 week, and decreased at initial level in 4 weeks, below the initial level in 12 weeks(p<0.01). 3. In 1 week, significant difference in tooth mobility between control and experimental group was found(p<0.01) but, in 12 weeks no difference between two groups was found. 4. Change of immediate tooth mobility after treatment was more larger in deep pocket than in shallow one. In group with the same probing pocket depth, the change of tooth mobility in molar group was greater than that of premolar group. 5. Tooth mobility before treatment was more strongly correlated with radiographic bone loss (r=0.5325) than probing depth, attachment loss and bleeding on probing, in 12 weeks after treatment, was more strongly correlated with attachment loss($r^2$=0.4761) than probing depth and bleeding on probing. Evaluation of the treatment effect and the prognosis after root planing and flap operation were meaningful on tooth initial probing depth 4mm and more. After flap operation, evaluation of the prognosis should be performed at least in 4 weeks and in 12 weeks after treatment, no difference in tooth mobility between two groups was observed. Radiographic bone loss and attachment loss were good clinical indicators to evaluate tooth mobility.

  • PDF

Analysis of Tropospheric Carbon Monoxide over East Asia

  • Lee, S.H.;Choi, G.H.;Lim, H.S.;Lee, J.H.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.615-617
    • /
    • 2003
  • Carbon monoxide (CO) is one of the important trace gases because its concentration in the troposphere directly influences the concentrations of tropospheric hydroxyl (OH), which controls the lifetimes of tropospheric trace gases. CO traces the transport of global and regional pollutants from industrial activities and large scale biomass burning. The distributions of CO were analyzed using the MOPITT data for East Asia, which were compared with the ozone distributions. In general, seasonal CO variations are characterized by a peak in the spring, which decrease in the summer. The monthly average for CO shows a similar profile to that for O$_3$. This fact clearly indicates that the high concentration of CO in the spring is possibly due to one of two causes: the photochemical production of CO in the troposphere, or the transport of the CO into East Asia. The seasonal cycles for CO and O$_3$ in East Asia are extensively influenced by the seasonal exchanges of different air mass types due to the Asian monsoon. The continental air masses contain high concentrations of O$_3$ and CO, due to the higher continental background concentrations, and sometimes to the contribution from regional pollution. In summer this transport pattern is reversed, where the Pacific marine air masses that prevail over Korea bring low concentrations of CO and O$_3$, which tend to give the apparent summer minimums.

  • PDF

Development of Operation and Control Technology of Energy Storage System for Frequency Regulation and Operation by Grid Connected Automatic Control (주파수조정용 에너지저장장치 운전제어 기술의 개발과 계통연계 자동제어 운전)

  • Lim, Geon-Pyo;Choi, Yo-Han;Im, Ji-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.235-241
    • /
    • 2016
  • Grid-connected, large-capacity energy storage systems (ESS) can be used for peak load supply, frequency regulation, and renewable energy output smoothing. In order to confirm the capability of battery ESS to provide such services, 4MW/ 8MWh battery ESS demonstration facility was built in the Jocheon substation on Jeju Island. The frequency regulation technology developed for the Jocheon demonstration facility then became the basis for the 28MW and 24MW frequency regulation ESS facilities installed in 2014 at the Seo-Anseong and Shin-Yongin substations, respectively. The operation control systems at these two facilities were continuously improved, and their successful commercialization led to the construction of additional ESS facilities all over Korea in 2015. In seven (7) locations nationwide (e.g., Shin-Gimje and Shin-Gyeryeong), a total of 184 MW of ESS had been commercialized in 2016. The trial run for the new ESS facilities had been completed between April and May in 2016. In this paper, results of the trial run from each of the ESS facilities are presented. The results obtained from the Seo-Anseong and Shin-Yongin substations during a transient event by a nuclear power plant trip are also presented in this paper. The results show that the frequency regulation battery ESS facilities were able to quickly respond to the transient event and trial run of ESS is necessary before it is commercialized.

Reservoir Operation by Tabu Search Method during Flood (타부탐색기법에 의한 홍수시 저수지 운영에 관한 연구)

  • Jeong, Han-Woo;Choi, Seung-An;Kim, Hung-Soo;Shim, Myung-Phil
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.9 s.158
    • /
    • pp.761-770
    • /
    • 2005
  • This study applied the fuzzy logic control for the construction of the reservoir operation model which can consider uncertainty of the predicted inflow in determining reservoir release during flood period. The control rule is usually constructed based on the opinion of experts which is a general technique. To improve the drawback of general technique, this study constructed the Fuzzy-Tabu search model automatically established by the fuzzy rule using Tabu search which is a global optimization technique. As the results, the peak release is decreased and the flood control efficiency is improved. The total release is also decreased and this represents the benefit in water use. Consequently, it is confirmed that the effect of flood control can be increased through the constructed model. It also shows that the available water resources after the flood is more increased. So, the proposed Fuzzy-Tabu search model could be better than the actual reservoir operation methodology in the aspect of water use.

Development of Walking Type Chinese Cabbage Transplanter (보행형 배추정식기 개발)

  • Park S. H.;Kim J. Y.;Choi D. K.;Kim C. K.;Kwak T. Y.;Cho S. C.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.2 s.109
    • /
    • pp.81-88
    • /
    • 2005
  • Manual transplanting Chinese cabbage needs 184 hours per ha in Korea. Mechanization of Chinese cabbage transplanting operation has been highly required because it needs highly intensive labor during peak season. This study was conducted to developed walking-type Chinese cabbage transplanter. In order to find out design factor of the transplanter, a kinematic analysis software, RecurDyn, was used. The prototype was tested in the circular soil bin and its operating motion was captured and analyzed using high speed camera system. Prototype was one row type which utilized original parts of engine, transmission and etc. from walking-type rice transplanter in order to save the manufacturing cost. Success ratio of pick-up device of hole-pin type and latch type were $96.0\%$ and $99.2\%$, respectively. which was highly affected by feeding accuracy of feeding device of seedling. Transplanting device of the prototype produced a elliptic loci which were coincident with those produced by the computer simulation. Prototype proved good performance in transplanting with mulching and without mulching operation, either. Working performance of prototype was 22 hours per ha and operation cost of the prototype was 961,757 won per ha. So, it would reduce $88\%$ of the labor and $29\%$ of operation cost.

Analysis of Tropospheric Carbon Monoxide in the Northeast Asia from MOPITT

  • Lee, Sang-Hee;Choi, Gi-Hyuk;Lim, Hyo-Suk;Lee, Joo-Hee
    • Korean Journal of Remote Sensing
    • /
    • v.19 no.3
    • /
    • pp.217-221
    • /
    • 2003
  • The Measurement of Pollution in the Troposphere (MOPITT) instrument is an eight-channel gas correlation radiometer that launched on the Earth Observing System (EOS) Terra spacecraft in 1999. Its main objectives are to measure carbon monoxide (CO) and methane (CH4) concentrations in the troposphere. This study analyzes tropospheric carbon monoxide distributions using MOPITT data and compare with ozone distributions in Northeast Asia. In general, seasonal CO variations are characterized by a peak in spring and decrease in summer. Also, this study revealed that the seasonal cycles of CO are maximum in spring and minimum in summer with average concentrations ranging from 118ppbv to 170ppbv. The monthly average of CO shows a similar profile to those of O3. This fact clearly indicates that the high concentration of CO in spring is caused by two possible causes: the photochemical CO production in the troposphere, or the transport of the CO in the northeast Asia. The CO and $O_3$ seasonal cycles in the Northeast Asia are influenced extensively by the seasonal exchange of the different types of air mass due to the Asian monsoon. The continental air masses contain high concentrations of $O_3$ and CO due to higher continental background concentrations and sometimes due to the contribution of regional pollution. In summer the transport pattern is reversed. The Pacific marine air masses prevail over Korea, so that the marine air masses bring low concentrations of CO and $O_3$, which tend to give the apparent minimum in summer.

Preliminary design and assessment of a heat pipe residual heat removal system for the reactor driven subcritical facility

  • Zhang, Wenwen;Sun, Kaichao;Wang, Chenglong;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.3879-3891
    • /
    • 2021
  • A heat pipe residual heat removal system is proposed to be incorporated into the reactor driven subcritical (RDS) facility, which has been proposed by MIT Nuclear Reactor Laboratory for testing and demonstrating the Fluoride-salt-cooled High-temperature Reactor (FHR). It aims to reduce the risk of the system operation after the shutdown of the facility. One of the main components of the system is an air-cooled heat pipe heat exchanger. The alkali-metal high-temperature heat pipe was designed to meet the operation temperature and residual heat removal requirement of the facility. The heat pipe model developed in the previous work was adopted to simulate the designed heat pipe and assess the heat transport capability. 3D numerical simulation of the subcritical facility active zone was performed by the commercial CFD software STAR CCM + to investigate the operation characteristics of this proposed system. The thermal resistance network of the heat pipe was built and incorporated into the CFD model. The nominal condition, partial loss of air flow accident and partial heat pipe failure accident were simulated and analyzed. The results show that the residual heat removal system can provide sufficient cooling of the subcritical facility with a remarkable safety margin. The heat pipe can work under the recommended operation temperature range and the heat flux is below all thermal limits. The facility peak temperature is also lower than the safety limits.

Low Noise Vacuum Cleaner Design (저소음 청소기 개발)

  • Joo, Jae-Man;Lee, Jun-Hwa;Hong, Seun-Gee;Oh, Jang-Keun;Song, Hwa-Gyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.939-942
    • /
    • 2007
  • Vacuum cleaner is a close life product that can remove various dusts from our surroundings. However well vacuum cleaner clean our environments, many people are looking away from it, due to its loud noise. Its noise causes a big trouble in the usual life, for example, catch calls, TV watching and discussing etc. To reduce these inconveniences, noise reduction methods and systematic design of low noise vacuum cleaner are studied in this paper. At first, sound quality investigation is performed to get the noise level and quality that make people TV watching and catch calls available. Based on the European and domestic customer SQ survey result, sound power, peak noise level and target sound spectrum guideline are studied and introduced. As a second, precise product sound spectrums are designed into each part based on the sound quality result. Fan-motor, brush, mainbody, cyclone spectrums are decided to get the final target sound based on the contribution level. Fan-motor is the major noise source of vacuum cleaner. Specially, its peak sound, RPM peak and BPF Peak, cause the people nervous. To reduce these peak sounds, high rotating impeller and diffuser are focused due to its interaction. A lot of experimental and numerical tests, operation points are investigated and optimization of flow path area between diffusers is performed. As a bagless device, cyclones are one of the major noise sources of vacuum cleaner. To reduce its noise, previous research is used and adopted well. Brush is the most difficult part to reduce noise. Its noise sources are all comes from aero-acoustic phenomena. Numerical analysis helps the understanding of flow structure and pattern, and a lot of experimental test are performed to reduce the noise. Gaps between the carpet and brush are optimized and flow paths are re-designed to lower the noise. Reduction is performed with keeping the cleaning efficiency and handling power together and much reduction of noise is acquired. With all above parts, main-body design is studied. To do a systematic design, configuration design developments technique is introduced from airplane design and evolved with each component design. As a first configuration, fan-motor installation position is investigated and 10 configuration ideas are developed and tested. As a second step, reduced size and compressed configuration candidates are tested and evaluated by a lot of major factor. Noise, power, mass production availability, size, flow path are evaluated together. If noise reduction configuration results in other performance degrade, the noise reduction configuration is ineffective. As a third configuration, cyclones are introduced and the size is reduced one more time and fourth, fifth, sixth, seventh configuration are evolved with size and design image with noise and other performance indexes. Finally we can get a overall much noise level reduction configuration. All above investigations are adopted into vacuum cleaner design and final customer satisfaction tests in Europe are performed. 1st grade sound quality and lowest noise level of bagless vacuum cleaner are achieved.

  • PDF