• Title/Summary/Keyword: Peak load estimation

Search Result 73, Processing Time 0.022 seconds

Performance Evaluation of Motor-Operated Valve Using Electrical Signatures

  • Park, Joo-Moon;Joo, Hyung-Jun;Jung, Jae-Cheon;Sung, Key-Yong;Seong, Se-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.52-55
    • /
    • 2001
  • This paper is to see the availability of electrical signatures as a means for evaluating the performance and monitoring mechanical anomalies of (MOVs). To estimate motor torque, two methods such as d-q frame conversion and air-gap method are suggested and estimated results are compared with measured values. The error between measured and estimated torques is within acceptable error bound with below $1\%$ under varied load. Frequency domain analysis of calculated torque has been done as well. It is shown that monitoring of peak frequency could give useful clues to detect anomalies of MOV. As results, electrical signatures at MOV motor is expected to be an available tool for estimation of motor capacity and monitoring of electrical and mechanical abnormalities.

  • PDF

An experimental Study on Effect of Lateral Ties of High-Strength Concrete Columns (고강도 콘크리트 기둥에서 띠철근의 구속효과에 관한 실험적 연구)

  • 정봉호;곽노현;이영호;은희창;정헌수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.501-506
    • /
    • 1999
  • The purpose of this study is to experimentally investigate the strength and ductility of reinforced high strength concrete columns under uniaxial load and several test variables. To do this, we have conducted tests on thirteen 20$\times$20$\times$60cm specimens with 8 and 12 longitudinal steel bars subjected to monotonic uniaxial compression. The main variables considered in this test are the configuration of ties, the space the ties, the diameter of ties and yield strength of ties. The results indicate that the strength and the ductility of reinforced high strength concrete columns have been influenced on these variables except yield strength of ties. Judging from test results, real stress of ties at peak concrete stress is suitable variable than yield strength of ties for estimation of the strength gain factor(Ks).

  • PDF

Macromodel for Short Circuit Power and Propagation Delay Estimation of CMOS Circuits

  • Jung, Seung-Ho;Baek, Jong-Humn;Kim, Seok-Yoon
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.1005-1008
    • /
    • 2000
  • This paper presents a simple method to estimate short-circuit power dissipation and propagation delay for static CMOS logic circuits. Short-circuit current expression is derived by accurately interpolating peak points of actual current curves which is influenced by the gate-to-drain coupling capacitance. The macro model and its expressions estimating the delay of CMOS circuits, which is based on the current modeling expression, are also proposed after investigating the voltage waveforms at transistor output modes. It is shown through simulations that the proposed technique yields better accuracy than previous methods when signal transition time and/or load capacitance decreases, which is a characteristic of the present technological evolution.

  • PDF

Longitudinal reaction on conductors due to tornado wind load

  • Dingyu Yao;Ashraf El Damatty
    • Wind and Structures
    • /
    • v.38 no.4
    • /
    • pp.325-339
    • /
    • 2024
  • The longitudinal force resulting from tornado loads on transmission line is considered a crucial factor contributing to the failure of transmission line structures during tornado events. Accurate estimation of this longitudinal force poses a challenge for structural designers. Therefore, the objective of this paper is to provide a set of charts that can be easily used to estimate the peak longitudinal forces transferred from the conductors to a tower. The critical wind field and corresponding configuration considered in this paper are previously studied and determined. The charts should account for all the conductor parameters that can affect the value of the longitudinal force. In order to achieve that, a parametric study is first conducted to assess the variation of the longitudinal forces with different conductor parameters, based on the critical tornado configuration. Results of this parametric study are used to develop the charts that can be used to calculate longitudinal forces by adopting a multi-variable line regression. The forces calculated from charts are validated by finite element analysis. An example for the usage of the charts is provided at the end of this paper.

Washoff Characteristics of Non-point Source pollutants and Estimation of Unit Loads in Suburban Industrial Complex Areas Runoff (교외 산업단지지역 강우유출수내 비점오염물질의 유출특성 및 원단위 산정)

  • Kim, Sung-Joon;Shin, Seon-Mi;Jeon, Yong-Tae;Won, Chan-Hee
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.2
    • /
    • pp.315-325
    • /
    • 2012
  • The characteristics of stormwater runoff and estimation of unit loads were examined in suburban industrial complex areas. During rainfall event, the peak concentrations occurred within the first 100 minutes after rainfall and then the highest concentration of NPS pollutants sharply decreased, showing strong first flush effect in suburban industrial complex. The cumulative load curves for NPS pollutants showed above the straight line, indicating that first flush effect occurred in suburban industrial complex. While the mean TSS, BOD, COD, TN and TP EMCs values were shown the highest values as 120.6 mg/L, 20.8 mg/L, 44.0 mg/L, 5.58 mg/L and 1.46 mg/L respectively. Unit loads estimated from the EMCs were TSS $43.86kg/km^2/day$, COD $52.45kg/km^2/day$, BOD $24.79kg/km^2/day$, T-N $6.65kg/km^2/day$, T-P $1.75kg/km^2/day$, and Pb $0.10kg/km^2/day$. Results of unit loads were compared with the unit pollutant loads from land-use in Korea and USA. The unit load of TSS was lower than that of USA. Estimated BOD and T-N and T-P unit loads were lower than that of Korea.

Characterization of Stormwater Pollutants and Estimation of Unit Loads for Road and Parking Lot in Gyeongan Stream Watershed (경안천지역의 도로 및 주차장에 대한 강우유출수의 특성분석과 원단위 산정)

  • Go, Sung-Hun;Memon, Sheeraz Amed;Lee, Chang-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.689-696
    • /
    • 2009
  • Unit load approach has been used to estimate the non-point pollutant load in Total Water Pollution Load Management System (TWPLMS). In this study, locally applicable unit loads for road and parking lot were developed based on the measurements of 9 rainfall events from 2007 to 2008 in Yongin city of Gyeongan stream watershed. Observations showed that stormwater runoff began at low precipitation (>1 mm) and peak pollutant concentration occurred at the beginning of the runoff because of impervious nature of the sites. Averaged event mean concentrations (EMCs) of road (parking lot) were estimated as COD 105.36(62.69) mg/L, BOD 15.94(13.20) mg/L, TSS 183.45(66.52) mg/L, T-N 4.63(3.28) mg/L, T-P 0.45(0.39) mg/L. Higher EMCs at the road than parking lot may reflect heavier traffic. Unit loads Estimated from the EMCs and 10 year average rainfall data were COD $331.17kg/km^2{\cdot}day$, BOD $50.20kg/km^2{\cdot}day$, TSS $580.13kg/km^2{\cdot}day$, T-N $14.68kg/km^2{\cdot}day$, T-P $1.43kg/km^2{\cdot}day$ in the road and COD $186.59kg/km^2{\cdot}day$, BOD $39.22kg/km^2{\cdot}day$, TSS $199.15kg/km^2{\cdot}day$, T-N $9.70kg/km^2{\cdot}day$, T-P $1.16kg/km^2{\cdot}day$ in the parking lot. The estimated unit loads are not so comparable to the ones listed in TWPLMS technical guideline and published data that locally developed unit loads should be used to estimate non-point pollutant loads.

A Control System for Attenuating Voltage-Dip and Inrush Current Caused by Starting of Inductive Load Nnetwork (유도성 부하 네트워크의 기동에 의한 순간전압강하 및 기동전류 감쇄를 위한 제어시스템)

  • Kim, Sang-Kon;Choi, In-Kyum;Kim, Tae-Kon;Seo, Sung-Kyu
    • Journal of IKEEE
    • /
    • v.16 no.2
    • /
    • pp.109-115
    • /
    • 2012
  • We propose a control system consisted of TRIAC PWM module and sequential start control system attenuating voltage-dip and inrush current caused by starting of inductive load network. To minimize the high voltage-dip and inrush current induced from a large capacity inductive load, we developed a TRIAC PWM module. And we also developed a sequential start control system preventing simultaneous starting of the inductive loads within a same power network. According to the experimental results with the proposed control system, the voltage-dip and inrush current could be effectively attenuated such that they can meet the related international standards and resolve the issues associated with simultaneous starting of multiple inductive loads. By employing this system, power cost usually implemented by the estimation of peak power consumption can be reduced and the power quality of a power distribution system connected to the inductive load network can be stabilized efficiently.

Pressure-load Calibration of Multi-anvil Press at Ambient Temperature through Structural Change in Cold Compressed Amorphous Pyrope (비정질 파이로프의 저온 압축에 따른 구조 변화를 이용한 멀티 앤빌 프레스의 상온 압력-부하 보정)

  • Lhee, Juho;Kim, Yong-Hyun;Lee, A Chim;Kim, Eun Jeong;Lee, Seoyoung;Lee, Sung Keun
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.1
    • /
    • pp.65-73
    • /
    • 2022
  • The proper estimation of physical and chemical properties of Earth materials and their structures at high pressure and high temperature conditions is key to the full understanding of diverse geological processes in Earth and planetary interiors. Multi-anvil press - high-pressure generating device - provides unique information of Earth materials under compression, mainly relevant to Earth's upper mantle. The quantitative estimation of the relationship between the oil load within press and the actual pressure conditions within the sample needs to be established to infer the planetary processes. Such pressure-load calibration has often been based on the phase transitions of crystalline earth materials with known pressure conditions; however, unlike at high temperature conditions, phase transitions at low (or room) temperatures can be sluggish, making the calibration at such conditions challenging. In this study, we explored the changes in Al coordination environments of permanently densified pyrope glasses upon the cold compression using the high-resolution 27Al MAS and 3QMAS NMR. The fractions of highly coordinated Al in the cold compressed pyrope glasses increase with increasing oil load and thus, the peak pressure condition. Based on known relationship between the peak pressure and the Al coordination environment in the compressed pyrope glasses at room temperature, we established a room temperature pressure-load calibration of the 14/8 HT assembly in 1,100-ton multi-anvil press. The current results highlight the first pressure-load calibration of any high pressure device using high-resolution NMR. Irreversible structural densification upon cold compression observed for the pyrope glasses provides insights into the deformation and densification mechanisms of amorphous earth materials at low temperature and high pressure conditions within the subducting slabs.

Application of AGNPS Model for Nitrogen and Phosphorus Load in a Stream Draining Small Agricultural Watersheds (소규모 농업유역에서 질소와 인의 하천 부하에 대한 AGNPS 모형의 적용)

  • Kim, Min-Kyeong;Choi, Yun-Yeong;Kim, Bok-Jin;Lim, Jun-Young;Chung, Jong-Bae
    • Korean Journal of Environmental Agriculture
    • /
    • v.20 no.3
    • /
    • pp.192-200
    • /
    • 2001
  • The event-based agricultural non-point source(AGNPS) pollution model was applied to estimate the loads of nitrogen and phosphorus in a stream draining small agricultural watersheds. Calibration and verification of the model were performed using observed data collected from rainfall events in the Imgo watersheds during 1997-1998. Parameter calibrations were made for the runoff curve number. The peak flow volumes in the watersheds were well reproduced by the modified model. Average deviation between observed and simulated values was 10%, and this match was confirmed by the coefficient of efficiency value of 0.97. The deviations tended to increase as the peak flows increased. The simulated total N concentrations in the stream water were fairly close to the measured values, and the coefficient of efficiency in the estimation was 0.93. However, there were relatively large variations between calculated and observed values of total P concentration, and the coefficient of efficiency in the estimation was 0.74. Any inaccuracies that arise in estimating runoff flow and nutrient loading can not be explained exactly and further adjustment and refinements may be needed for application of AGNPS in agricultural watersheds. With this restrictions in mind, it can be concluded that AGNPS can provide realistic estimates of nonpoint source nutrient yields.

  • PDF

Estimation of Reasonable Price of Battery Energy Storage System for Electricity Customers Demand Management (전력소비자 수요관리용 전지전력저장시스템의 적정 가격 산정)

  • Kim, Seul-Ki;Cho, Kyeong-Hee;Kim, Jong-Yul;Kim, Eung-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1390-1396
    • /
    • 2013
  • The paper estimated the reasonable market price of lead-acid battery energy storage system (BESS) intended for demand management of electricity customers. As time-of-use (TOU) tariffs have extended to a larger number of customers and gaps in the peak and off-peak rates have gradually risen, deployment of BESS has been highly needed. However, immature engineering techniques, lack of field experiences and high initial investment cost have been barriers to opening up ESS markets. This paper assessed electricity cost that BESS operation could save for customers and, based on the possible cost savings, estimated reasonable prices at which BESSs could become a more prospective option for demand management of customers. Battery scheduling was optimized to maximize the electricity cost savings that BESS would possibly achieve under TOU tariffs conditions. Basic economic factors such as payback period and return on investment were calculated to determine reasonable market prices. Actual load data of 12 industrial customers were used for case studies.