• Title/Summary/Keyword: Peak force

Search Result 732, Processing Time 0.024 seconds

Effects of 3D Compression Pants and Kinesio Taping on Isokinetic Muscular Function of Leg During Knee Joint Flexion Motion (3D 밀착형 팬츠와 키네시오 테이핑이 무릎관절의 등속성 굴곡 운동 시 하지의 근기능에 미치는 영향)

  • Choi, Jiyoung;Park, Heegeun;Lee, Wanglok;Hong, Kyunghi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.2
    • /
    • pp.240-257
    • /
    • 2016
  • This study determines the effect of 3D compression pants and Kinesio taping on muscular function of the leg during knee joint flexion and extension. Eight males participated in the experiment, wearing basic pants (BP), Kinesio taping on bare skin (KT), 3D compression pants with (KTP) and without Kinesio taping (CP). The test protocol for isokinetic muscular function was composed of four sets at three angular velocities (60, 180, $240^{\circ}/sec$) using Cybex 660. Peak torque and work per repetition of the lower limbs of eight males were analyzed from the result of Cybex. Agility and power of the subjects were examined from side step and sergeant jump. Peak torque, average power, work per repetition, force decay time of subjects wearing CP and KTP were significantly better than BP or KT, especially at low angular velocity of $60^{\circ}/sec$. The time to generate peak torque of subjects wearing BP was the longest, while the force-decay time of BP was the shortest. The application of Kinesio tape on skin did not increase muscle peak torque, work and power, but did shorten the time to generate peak torque.

Comparison of Muscle Strength for One-hand and Two-hands Lifting Activity (한 손 들기 작업과 양 손 들기 작업의 근력 능력 비교 연구)

  • Kim, Hong-Ki
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.35-44
    • /
    • 2007
  • Work-related musculoskeletal disorders (WMSDs) are a major problem in industries in which manual materials handling is performed by workers. To prevent these WMSDs, it is necessary to understand the muscular strength capability and use this knowledge to design job and selection and assignment of workers. Even though two-hands lifting activity of manual materials handling tasks are prevalent at the industrial site, many manual materials handling tasks which require the worker to perform one-hand lifting are also very common at the industrial site and forestry and farming. However, a few researches have been done for one-hand lifting activity of manual materials handling tasks. The objective of this study is to compare one-hand and two-hands lifting strength in terms of static and dynamic strength of the lifting activity for the ranging from the height of knuckle to elbow. It is shown in this study that the isometric lifting strength of one-hand is ranging from 54.7 to 63.3% of the one of two-hands. However, it is found that there is no significant difference between a person's isometric lifting strength for left-hand and right-hand. It is also shown that there is no significant difference between the peak force under the dynamic sub-maximal loading with one-hand and two-hands lifting activity. Similar results were obtained for the peak acceleration and peak velocity under the dynamic sub-maximal loading with one-hand and two-hands lifting activity. Isometric lifting strength at the height of knuckle was ranging from 2 to 3 times of the dynamic peak force during sub-maximal lifting. It is concluded that the dynamic peak forces under the sub-maximal loading are not highly correlated with the isometric lifting strength in similar postures.

GRAPE AND PROJECT MILKYWAY

  • MAKINO JUNICHIRO
    • Journal of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.165-168
    • /
    • 2005
  • We overview the GRAPE (GRAvity piPE) project. The goal of the GRAPE project is to accelerate the astrophysical N-body simulations. Since almost all computing time is spent for the evaluation of the gravitational force between particles, we can greatly accelerate many N-body simulations by developing a specialized hardware for the force calculation. In 1989, the first such hardware, GRAPE-1, was completed, with the peak speed of 120 Mflops. In 2003, GRAPE-6 was completed, with the peak speed of 64 Tflops, which is nearly 106 times faster than GRAPE-l and was the fastest computer at that time. In this paper, we review the basic concept of the GRAPE hardwares, the history of the GRAPE project, and two ongoing projects, GRAPE-DR and Project Milkyway.

Dynamic Analysis of a Gear Driving System with Time-varying Mesh Stiffness/Damping and Friction (변동물림강성/감쇠와 마찰을 고려한 기어구동계의 동특성 해석)

  • Kim, Woo-Hyung;Jung, Tae-Il;Chung, Jin-Tai
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.224-231
    • /
    • 2006
  • A six-degree-of-freedom dynamic model with time-varying mesh stiffness/damping and friction has been developed for the dynamic analysis of a gear driving system. This model includes a spur gear pair, bearing, friction and prime mover. Using Newton???s method, equations of motion for the gear driving system were derived. Two computer programs are developed to calculate mesh stiffness, transmission error and friction force and analyze the dynamics of the modeled system using a time integration method. The influences of mesh stiffness/damping, bearing, and friction affecting the system were investigated by performing eigenvalue analysis and time response analysis. It is found that the reduction of the maximum peak magnitude by friction is decided according to designing the positions of pitch point and maximum peak in the responses.

  • PDF

A hybrid-separate strategy for force identification of the nonlinear structure under impact excitation

  • Jinsong Yang;Jie Liu;Jingsong Xie
    • Structural Engineering and Mechanics
    • /
    • v.85 no.1
    • /
    • pp.119-133
    • /
    • 2023
  • Impact event is the key factor influencing the operational state of the mechanical equipment. Additionally, nonlinear factors existing in the complex mechanical equipment which are currently attracting more and more attention. Therefore, this paper proposes a novel hybrid-separate identification strategy to solve the force identification problem of the nonlinear structure under impact excitation. The 'hybrid' means that the identification strategy contains both l1-norm (sparse) and l2-norm regularization methods. The 'separate' means that the nonlinear response part only generated by nonlinear force needs to be separated from measured response. First, the state-of-the-art two-step iterative shrinkage/thresholding (TwIST) algorithm and sparse representation with the cubic B-spline function are developed to solve established normalized sparse regularization model to identify the accurate impact force and accurate peak value of the nonlinear force. Then, the identified impact force is substituted into the nonlinear response separation equation to obtain the nonlinear response part. Finally, a reduced transfer equation is established and solved by the classical Tikhonove regularization method to obtain the wave profile (variation trend) of the nonlinear force. Numerical and experimental identification results demonstrate that the novel hybrid-separate strategy can accurately and efficiently obtain the nonlinear force and impact force for the nonlinear structure.

Experimental Study on Side Impact Characteristics for Automotives Door Module (자동차용 도어 모듈의 측면 충돌특성에 관한 실험적 연구)

  • Jeon, S.J.;Kim, M.H.;Lee, G.B.;Lee, M.Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.318-318
    • /
    • 2009
  • The door stiffness is one of the important factors side impact. Generally, the researches have been conducted on the assembled door module. This study is to analysis the side impact characteristics for automotives door module. The impact characteristics have been determined by door module side impact test machine. To determine the initial, intermediate and peak crush resistances use the plot of load versus displacement and obtain the integral of the applied load with respect to the crush distances specified below for each door tested. The initial crush resistance is the average force required to deform the door through the initial 6 inches of crush. The intermediate crush resistance is the average force required to deform the door through the initial 12 inches of crush. The peak crush resistance will be directly obtained from the plot of load versus displacement since it is the largest force required to deform the door through the entire 18 inches crush distance. The data are used to determine if a specific vehicle or item of automotives equipment meets the minimum performance requirements of the subject Federal Motor Vehicle Safety Standard(FMVSS). FMVSS Static 214, Side impact protection, specifies performance requirements for protection of occupants in side impact crashes.

  • PDF

The Gait Analysis of Hemiplegic Patients After Stroke I. Spatio-Temporal Parameters, Pelvic Anterior Tilting and Ground Reaction-Vertical Force (뇌졸중으로 인한 편마비환자의 보행분석 I. 시간-거리변수, 골반경사각 및 지면반발력 -수직력 중심)

  • Kwon Young-Sil;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.10 no.1
    • /
    • pp.127-138
    • /
    • 1998
  • This study was carried out tn invstigate and compare biomechanical characteristics during free speed gait in hemiplegic patients after stroke who took therapeutic exercise by analyzing kinematic and kinetic data in the sagital plane and electromyographic data. Six patients($41\~69$ years old) and age-matched six volunteers in good health(51-61 years old) wire studied. The patients were sorted into two groups, depending on their self-speed of walking : fast speed group(3 patients) and slow speed group(3 patients). The results were as fellows. : 1. In spatio-temparal parameters, affected and unaffected side of fast group showed symetry but blew group showed asymetry of single limb support, opposite foot contact and stance phase (p<0.05). Compared with normal group, patient group showed slower velocity, shoter stride length and longer double limb support (p<0.05). 2. In the pelvic anterior tilt, patient group showed lower valued than normal group. It. In the ground reaction force-vertical force, fast group showed similar double peak gragh compared with normal group, butvslow group showed lower values without double peak (p<0.05).

  • PDF

Effect of Swing Limb Heel-Strike Accuracy on Force Modulation and EMG While Stepping over an Obstacle versus Initiating Gait from a Position of Quiet Stance (보통 보행과 장애물 보행 시작시 에서 발꿈치 닿기 (Heel-Strike)의 정확도가 힘 조절과 EMG 에 미치는 영향)

  • Kim Hyeong-Dong;Park Rae-Jun;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.2
    • /
    • pp.196-209
    • /
    • 2003
  • 본 연구의 목적은 보통 보행과 장애물 보행 시작시에 accuracy constraints, 즉 발꿈치 닿기(swing limb heel-strike)의 정확도가 힘판(forceplate) 상에서 힘의 조절 (force modulation)과 EMG에 어떠한 영향을 미치는지를 분석하는 것이다. 본 실험의 대상자는 힘판(forceplate)위에서 보통 보행과 장애물 보행을 하되, 대상자 앞에 놓인 표적(target)에 정확히 발꿈치 닫기 (heel-strike)를 하도록 유도되었다. 이 때 힘판 자료와 전경골근(tibialis anterior)및 가자미근 (soleus)의 근전도 (EMG)의 활동을 양쪽 다리에서 측정하였다. 대상자 앞에 놓인 표적 (target)에 정확한 발꿈치 닫기(heel-strike)가 요구되었을 때에는 발끝밀기(swing toe-off) 시간이 증가되었으며 힘판(forceplate)상에서의 peak farce와 slope to peak force 가 감소되는 것으로 나타났다. 전경골근 (tibialis anterior)의 활동역시 큰 차이로 감소하는 것으로 나타났다. 하지만 보통 보행과 장애물 보행시의 근전도 혹은 힘판상의 자료에는 큰 차이점이 없는 것으로 나타났다. 이러한 결과는 기존의 상지(upper extremity)에서 보여준 운동제어 (motor control)의 이론들이 하지(lower extremity)에서도 동일하게 적용될 수 있음을 보여주는 것이다.

  • PDF

3-D Nano Topology Measurement using VCM (VCM(voice coil motor)를 이용한 3차원 나노 형상 측정 시스템)

  • Jung, Jong-Kyu;Youm, Woo-Sub;Park, Kiy-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1439-1443
    • /
    • 2007
  • In this paper, vibration reduction techniques of a voice coil motor (VCM) actuator are presented for AFM imaging system. The damping coefficient of the actuator driven by VCM with a flexure hinge is quite low and it cause the about 30dB peak amplitude response at the resonance frequency. To decrease this peak response, we design and apply elliptical band-stop filters to xy and z axis VCM actuator. Frequency response of each actuator with filter is measured to verify the effect of the filters. As a sensor, capacitive sensor is used. Vibration reduction rate of the xy actuator with the filter is also measured while real AFM scanning condition. As another method, closed loop control with the capacitive sensor is applied to the xy axis actuator to add an electrical damping effect and vibration reduction rate measured. These vibration reduction rates with each method are compared. In the case of z axis actuator, the frequency response of force (gap) control loop is measured. For comparison, the frequency response using a conventional PID controller is also obtained. Finally, the AFM image of a standard grid sample is measured with the designed controller to analyze the effect in the AFM imaging.

  • PDF

Optimum Shape Synthesis of Cam And Follower in Cam-Valve System to Minimize Contact Force (캠-밸브 기구에서 접촉력 최소화를 위한 캠과 종동자 형상 최적 합성)

  • 김성훈;전혁수;박윤식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.534-546
    • /
    • 1990
  • In this work, an optimum shape synthesis for rolling contact components was done to minimize contact forces considering dynamic characteristics of the system. Even this method was applied to an OHC type cam follower system, it can be expanded to general rolling contact shape design problems which are strictly forced to follow predetermined motion. First, the follower optimum angular motion was derived to minimize the valve peak acceleration while satisfying all the constraints of valve motion. Then the cam and follower contact shape were synthesized to give the proposed follower motion. Theoretically, two components shape to generate a predetermined motion can not be uniquely determined. So the cam shape was syntehsized with parametric synthesis method to minimize the peak contact force between cam and follower when the follower shape is assumed as a circle or an ellipse.