• 제목/요약/키워드: Peak force

검색결과 732건 처리시간 0.026초

Dynamic response analysis of floating offshore wind turbine with different types of heave plates and mooring systems by using a fully nonlinear model

  • Waris, Muhammad Bilal;Ishihara, Takeshi
    • Coupled systems mechanics
    • /
    • 제1권3호
    • /
    • pp.247-268
    • /
    • 2012
  • A finite element model is developed for dynamic response prediction of floating offshore wind turbine systems considering coupling of wind turbine, floater and mooring system. The model employs Morison's equation with Srinivasan's model for hydrodynamic force and a non-hydrostatic model for restoring force. It is observed that for estimation of restoring force of a small floater, simple hydrostatic model underestimates the heave response after the resonance peak, while non-hydrostatic model shows good agreement with experiment. The developed model is used to discuss influence of heave plates and modeling of mooring system on floater response. Heave plates are found to influence heave response by shifting the resonance peak to longer period, while response after resonance is unaffected. The applicability of simplified linear modeling of mooring system is investigated using nonlinear model for Catenary and Tension Legged mooring. The linear model is found to provide good agreement with nonlinear model for Tension Leg mooring while it overestimates the surge response for Catenary mooring system. Floater response characteristics under different wave directions for the two types of mooring system are similar in all six modes but heave, pitch and roll amplitudes is negligible in tension leg due to high restraint. The reduced amplitude shall lead to reduction in wind turbine loads.

Friction and Pull-off Forces on Submicron-Size Asperity Measured in High Vacuum

  • Ando, Y.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.57-58
    • /
    • 2002
  • Asperity arrays and Independent asperities were fabricated on a silicon plate. Then pull-off and friction forces were measured on each asperity pattern by using AFM (atomic force microscope) in humid air and high vacuum of $2{\times}10^{-5}$ Pa. The probe of AFM cantilever has a flat square of about $1\;{\mu}m^2$ on its tip. The results showed that the pull-off force was proportional to the curvature radius of asperity peak in each ambient condition. The friction force was proportional to the pull-off force and was slightly higher in the humid air than in the high vacuum.

  • PDF

광섬유 브래그 격자를 이용한 촉각 힘 센서의 개발 (Development of Tactile Force Sensor using Fiber Bragg Grating)

  • 김만섭;이정주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.811-816
    • /
    • 2004
  • The tactile force sensor was studied using Fiber Bragg Grating (FBG). The FBG is able to multiplex easily and is immune to electromagnetic environment. A sensor frame was designed to a cantilever beam type. Strain of a beam is related with the peak shift of a bragg wavelength. Finite Element Method (FEM) was used for getting an appropriate thickness from 0.2 mm to 0.3 mm thick. FEM results showed that 0.3 mm thick was suitable for the force range 10 N. The force resolutions of 0.039 N and 0.113 N were obtained with optical spectrum analyser and tunable Fabry-Perot filter, respectively.

  • PDF

하이브리드 도어 체커 개폐력 해석 (Door Effort Analysis for Hybrid Door Checker)

  • 강성종;김동환
    • 한국자동차공학회논문집
    • /
    • 제20권3호
    • /
    • pp.52-57
    • /
    • 2012
  • Proper door effort is required for the safety of passenger and pedestrian while securing door operating convenience. 3D finite element analyses for a hybrid door checker were carried out to estimate door checker arm resistance force. And, from the estimated door checker arm resistance force and theoretically calculated self-closing force, door effort was predicted. The analysis results at checker arm peaks showed excellent correlation with the test results. Also, in order to reduce solving time, a modified model with simple spring element was investigated. Finally an equation to easily calculate checker arm resistance force from checker arm shape and spring constant was suggested and its usefulness in early design stage was discussed.

과팽창 노즐 유동에서 발생하는 측력변동에 관한 연구 (A Study of Lateral Force Fluctuations in Over-Expanded Nozzle Flow)

  • 이종성;차용수;;김희동
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.253-256
    • /
    • 2009
  • 과팽창 상태 추력 노즐 내부의 측력(Lateral Force)발생에 대한 기초적 연구 분석을 실험적, 수치 해석적 방법으로 수행하였다. 엔진 정지 과정시 추력 노즐 내에 발생하는 압력진동을 조사하였다. 구동 압력비 변화에 따른 벽 압력 분포를 측정 및 쉴리렌 가시화를 수행하였다. RSS(Restricted Shock Separation)에서 FSS(Free Shock Separation)로 천이하는 순간 벽 압력 피크값이 발생하였다.

  • PDF

실린더 구조물을 설치한 탱크 내부의 슬로싱 하중과 유동 특성 (Characteristics of sloshing load and flow inside a tank with cylinder structures)

  • 김기종;서현덕;김대겸
    • 한국가시화정보학회지
    • /
    • 제21권1호
    • /
    • pp.31-39
    • /
    • 2023
  • Sloshing of the fluid having a free surface produces an impact force on a tank wall subjected to external excitation. This paper investigates the effect of cylindrical structures in a rectangular sloshing tank under translational harmonic excitations. By varying the number of installed cylinders in the tank, the characteristics of the free-surface deformation is experimentally observed, and the peak pressure on the tank wall is extracted by threshold values. To predict the peak pressure, the numerical simulation is also conducted using smoothed particle hydrodynamics (SPH), and the peak values are compared with the experimental results. Furthermore, pressure and velocity fields in the tank and free-surface shape are analyzed at the moment of impact.

Kinetics Analysis during Stance Phase of Fore Foot Contact versus Rear Foot Contact in Running

  • Cho, Woong;Han, Jae Woong;Kim, A Young;Park, Sung Kyu;Kim, Hyung Soo
    • 국제물리치료학회지
    • /
    • 제8권1호
    • /
    • pp.1084-1089
    • /
    • 2017
  • The purpose of this study was to compare and analyze the difference of the ankle joint movements during landing. Seven adult males voluntarily participated in the study and the average foot size of the subjects was 269.8 mm. Image analysis equipment and the ground reaction force plate (landing type) was used to measure th kinetic variables. As a result of this study, it was confirmed that the vertical ground reaction force peak point appeared once in the barefoot with forefoot, while two peak points appeared in the barefoot and functional shoe foot with rear foot landing. About ankle angle, fore foot landing ankle angle, the average with bare foot landing was $-10.302^{\circ}$ and the average with functional shoe foot landing was $-2.919^{\circ}$. Also about rear foot landing, ankle angle was $11.648^{\circ}$ with bare foot landing and $15.994^{\circ}$ with functional shoe landing. The fore foot landing, ankle joint force analysis produced 1423.966N with barefoot and 1493.264N with functional shoes. But, the rear foot landing, ankle joint force analysis produced 1680.154N with barefoot and 1657.286N with functional shoes. This study suggest that the angle of ankle depends on the landing type and bare foot running/functionalized shod running, and ankle joint forces also depends on landing type.

스포츠상해 예방훈련이 여자고등학교 농구선수들의 리바운드 점프 후 착지 시 지면반력에 미치는 영향 (The Effects of Sports Injury Prevention Training Program on the Ground Reaction Force during the Rebound in Female Highschool Basketball Players)

  • 임비오;정철수;신인식;김석범;남기정;이상우;박용현
    • 한국운동역학회지
    • /
    • 제18권1호
    • /
    • pp.31-38
    • /
    • 2008
  • 본 연구는 8주간의 전방십자인대 손상예방훈련이 농구 리바운드 점프 후 착지 시 지면반력에 미치는 영향을 규명하는 것이다. 본 연구에 참가한 연구 대상자는 $16{\sim}18$세 사이의 여자 농구선수 16명이다. 8주간의 전방십자인대 손상예방훈련을 수행할 실험집단 8명과 스포츠상해 예방훈련을 수행하지 않을 통제집단 8명을 무작위로 나눈 후 훈련 전후에 농구 리바운드 점프 후 착지 시 초기피크(%BW), 최대피크(%BW), 충격량(%BW.sec) 및 부하율 (N/sec)을 산출하였다. 본 연구 결과 농구 리바운드 점프 후 착지 시에 8주간의 전방십자인대 손상예방훈련을 받은 실험집단에서 초기피크 값이 감소하였다. 또한, 실험집단에서 지면반력의 충격량과 부하율이 유의하게 감소한 것으로 나타났다. 이는 8주간의 전방십자인대 손상예방 프로그램이 점프 동작에 필요한 하지의 근신경 조직에 유의한 긍정적 영향을 미쳐 효율적으로 착지한 것으로 판단된다.

개(犬)의 교합력 관찰을 위한 견치와 열육치의 3차원 유한요소 분석 (Three-Dimensional Finite element analysis of Canine and Carnassial for Observation of Dog Bite forces)

  • 박유진;김치영;최성민
    • 대한치과기공학회지
    • /
    • 제41권4호
    • /
    • pp.295-301
    • /
    • 2019
  • Purpose: This study is for the prosthesis of dogs. Observe the occlusal relation between the dog's canine and carnassial teeth. The strength and the direction of the occlusal by 3D FEM analysis. Methods: The mandibular canine and carnassial of dogs were tested. The dog's skull was contact point confirmed by dental CAD. The skull of the dog was 3D modeled by CT. The 3D model was analyzed by ABAQUS. Opening and closing movement has been a force of 100N, 200N, 300N, 500N, 1000N, 1,500N. The peak von Mises stress distribution was confirmed. Results: As occlusal force increased, stress appeared to 1.34 MPa, 3.32 MPa, 5.00 MPa, 6.19 MPa, 5.58 MPa, 5.47 MPa in left canine. and Stress was seen at 2.10 MPa, 3.08 MPa, 3.89 MPa, 5.50 MPa, 7.04 MPa, 7.18 MPa in the right canine. Stress appeared at 2.41 MPa, 3.53 MPa, 5.15 MPa, 7.28 MPa, 31.26 MPa, 67.22 MPa in the left carnassial. and Stress was seen at 1.57 MPa, 2.96 MPa, 3.76 MPa, 6.01 MPa, 20.94 MPa, 64.38 MPa in the right carnassial. Conclusion: Peak von Mises stress values were found at the peak of the canine, the buccal of the central cusp of the carnassial, and the occlusal surface of the distal cusp.

중족골 바 형태의 전족부 라커 신발이 하지 근 활성도 및 족저압력 분포에 미치는 영향 (Effects of Forefoot Rocker Shoes with Metatarsal Bar on Lower Extremity Muscle Activity and Plantar Pressure Distribution)

  • 박인식;정지용;전근환;원용관;김정자
    • 한국운동역학회지
    • /
    • 제22권1호
    • /
    • pp.113-121
    • /
    • 2012
  • The purpose of this study was to evaluate the effects of forefoot rocker shoes equipped with a metatarsal bar on lower extremity muscle activity and plantar pressure distribution. Ten healthy women in the age of twenties were participated in this study as the subjects. All subjects walked on a treadmill(Gait Trainer, BIODEX, USA) wearing normal shoes and metatarsal bar shoes, during which the plantar pressure distribution and muscle activity were measured. Using Pedar-X system(Novel Gmbh, Germany), the plantar pressure was measured for six regions of the foot: forefoot, midfoot, rearfoot, 1st metatarsal, 2-3th metatarsal, and 4-5th metatarsal, and for each sub-region, 4 features such as maximum force, contact area, peak pressure, and mean pressure were analyzed based on the plantar pressure. EMG(Electromyography) activity was measured by attaching surface electrodes to the rectus femoris, biceps femoris, tibialis anterior, and gastrocnemius medial head, and magnitude of muscle contraction was analyzed in IEMG(Integrated EMG) value. The results show that the maximum force, contact area, peak pressure, and mean pressure in the midfoot all increased while maximum force, peak pressure, contact area, mean pressure in the 1st metatarsal and 2-3th metatarsal all decreased when wearing functional shoes. Also, muscle activities in the four muscles were all decreased when wearing the functional shoes. This paper suggests that forfoot rocker shoes equipped with a metatarsal bar can help disperse the high pressure and absorb the shock to the foot as well as give positive influence on gait pattern and postural stability by reducing muscle fatigue during walking.