• Title/Summary/Keyword: Peak Flow

Search Result 1,466, Processing Time 0.024 seconds

Changes in Peak Expiratory Flow, Forced Expiratory Volume in 1 Second and Peak Cough Flow Related to Functional Level and Measurement Position in Patients With Duchenne Muscular Dystrophy (뒤시엔느 근 이영양증 환자에서 기능 수준과 측정 자세에 따른 최대호기유량, 1초간노력성호기량 및 최대기침유량의 변화)

  • Kim, Ki-Song;Cynn, Heon-Seock
    • Physical Therapy Korea
    • /
    • v.16 no.3
    • /
    • pp.1-8
    • /
    • 2009
  • It is important to find the effective position for cough and sputum clearance in respiratory physical therapy. The purpose of this study was to compare the changes in peak expiratory flow (PEF), forced expiratory volume in 1 second ($FEV_1$), and peak cough flow (PCF) related to functional level and measurement position in patients with Duchenne muscular dystrophy. Twenty one subjects were classified into three functional levels, and measurements was undertaken in three different measurement positions (upright sitting, $45^{\circ}$ reclining and supine). Vitalograph PEF/FEV DIARY was used to measure PEF and $FEV_1$, and Ferraris Pocket Peak was used to measure PCF. Mixed two-way analysis of variance and Bonferroni post-hoc test were used for statistical analysis. The results of the study were as follows: 1) Significant main effects for measurement position were found. 2) PEF was the highest in upright sitting, followed by $45^{\circ}$ reclining, and supine in order. 3) $FEV_1$ in upright sitting and $45^{\circ}$ reclining were significantly greater compared with that in supine. 4) PCF in upright sitting and $45^{\circ}$ reclining were significantly greater compared with that in supine. 5) No significant main effects for functional level were found in PEF, $FEV_1$, and PCF. 6) No significant functional level by measurement position interactions were found in PEF, $FEV_1$, and PCF. Therefore, it is concluded that upright sitting and $45^{\circ}$ degree reclining positions are recommended for effective cough and sputum clearance.

  • PDF

The Analysis of 2004 Summer Peak Load in Korea Power system (2004년 하계 첨두부하 시 계통운영 실적 분석)

  • Song, Tae-Yong;Hwang, Bong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.113-115
    • /
    • 2004
  • This year korea power system had recorded highest peak load for 6 times and finally it made new peak load 51,264MW at July 29th 3:00 PM. The new peak load is increased 8.2% from the last year peak load 47,385MW and korea power system entered 50,000MW load era. The Korea Power Exchange (KPX) snapped power system data at the peak load time using state estimation function in the EMS. And authors converted the power system data at peak load to PSS/E power flow format. Using this PSS/E peak load power flow data, this paper explains demand analysis result shun capacitor operation, voltage distribution at the peak load. And the paper shows the simulation result of 2 contingency analysis using the snapped PSS/E peak load data.

  • PDF

Clinical Outcome of Educational Program Using Self-monitoring of Peak Expiratory Flow Rate for Asthma Patients (천식 환자에 있어서 최대호기 유속의 자가 모니터링을 이용한 복약지도의 유용성)

  • Lee, Myung Bok;Shin, Hyun Taek;Kim, Sun Young
    • Korean Journal of Clinical Pharmacy
    • /
    • v.9 no.2
    • /
    • pp.97-102
    • /
    • 1999
  • The effects of pharmacist's intervention for asthma patients using self-monitoring of peak expiratory flow rate in medication teaching model was evaluated for 3 months in improving clinical outcomes including emergency visits, hospitalizations, antibiotics use, symptoms and sleep disturbance. Twenty seven patients were enrolled in study and twenty three patients completed the follow-up schedules. The selected patients were given the pre-designed instruction for medication including appropriate use of medication, metered-dose inhaler(MDI) technique, identifying and controling asthma triggers and recognizing early signs of deterioration. There were significant improvements in clinical outcomes, in terms of emergency visits, hopitalizations, antibiotics use, symptoms and sleep disturbance. There were also significant improvements in the MDI use, environmental control, and medication knowledges. There was a progressive increase in peak expiratory flow rate during the three-month intervention. In conclusion, pharmacist's intervention using self-monitoring of peak expiratory flow rate has a significant impact on improving clinical outcomes in asthma patients.

  • PDF

Tilt variation and wake turbulence in the otter board of a bottom trawl during fishing operations

  • KIM, Yong-Hae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.4
    • /
    • pp.337-348
    • /
    • 2017
  • The tension of warp from trawler and sea-floor contact can generate tilt and wake turbulence around otter boards. Preliminary measurements of otter board tilt and 3-D flow velocity during bottom trawl operations were taken using a vector instrument to investigate the effects of wake turbulence at the trailing edge of the otter board. Tilt data (i.e., yaw, pitch, and roll) at 1 Hz and flow data (velocities in the towing, lateral, and vertical directions) at 16 Hz were analyzed to determine their periods and amplitudes using global wavelet and peak event analyses. The mean period (${\pm}standard$ deviation) of the tilt from the peak event analysis ($5{\pm}2s$) was longer or double than that of flow velocity ($3{\pm}2s$). The two periods also had a significant linear relationship. The turbulence rate of flow was 30-50% at the trailing edge and was closely related to roll deviation. The frequency of phase difference ratios (i.e., peak time differences between tilts and flow periods) was significantly different from random occurrence in two trials, possibly due to side tidal effects. However, in the other trials, flow peaks were random, as shown by the even peak times between tilts and flows. Future studies should focus on reducing tilt variation, wake turbulence, and bottom contact to stabilize otter board motion.

A study of calculate a time to peak enhancement of contrast level by using blood flow (혈류에 의한 조영제 peak time의 산출에 관한 연구)

  • Choi, Kwan-Woo;Son, Soon-Yong;Lee, Ho-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2315-2321
    • /
    • 2013
  • This study attempt to develope and suggest a new, minimize side effects process for calculate a time to peak enhancement of contrast level by using blood flow instead of current mathematical process. We conducted a studies 127 patients who performed the CE MRA by using test-contrast inject way. We used measurements of a contrast inflow time and time to peak enhancement of contrast level of each cerebrovascular branch for similarity of witch cerebrovascular branch calculate a time to peak enhancement of contrast level by using blood flow in image compared with calculation a time to peak enhancement of contrast level by using current mathematical process after contrast enhancement. In this study, confidence interval were used if the variable is continuous variable; there is differences between 4 groups exist but in group 1, there is no difference with time in peak enhancement of contrast level by using mathematical method to inflow time in sinus sigmoideus. it was significant statistically, in addition there was significant low heterogeneity in Bland Altman plot. Thus, apply a new calculate a time to peak enhancement of contrast level by using blood flow method will minimize damage caused by side effect, maintain quality of image, easy and fast access. It should provide a space for the exchange of current calculate a time to peak enhancement of contrast level by using mathematical process.

Experimental study of rainfall spatial variability effect on peak flow variability using a data generation method (자료생성방법을 사용한 강우의 공간분포가 첨두유량의 변동성에 미치는 영향에 대한 실험적 연구)

  • Kim, Nam Won;Shin, Mun Ju
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.6
    • /
    • pp.359-371
    • /
    • 2017
  • This study generated flood time series of ungauged catchments in the Andongdam catchment using a distributed rainfall-runoff model and data generation method, and extracted the peak flows of 50 catchments to investigate the effect of rainfall spatial variability on peak flow simulation. The model performance statistics for three gauged catchments were reasonable for all events. The flood time series of the 50 catchments were generated using distributed and mean rainfall time series as input. The distribution of the peak flow using the mean rainfall was similar or slightly different to that using the distributed rainfall when the distribution of the distributed rainfall was nearly uniform. However, the distribution of the peak flow using the mean rainfall was reduced significantly compared to that using the distributed rainfall when actual storms moved to the top or bottom of the study catchment, or the rainfall was randomly distributed. These cases were 35% of total number events. Therefore, the spatial variability of rainfall should be considered for flood simulation. In addition, the power law relationship estimated using the peak flow of gauged catchments cannot be used for estimating the peak flow of ungauged independent catchments due to latter's significant variation of the peak flow magnitude.

Effects of Rain Garden on Reduction of Subsurface Runoff and Peak Flow (레인가든이 지하유출 및 첨두유량 감소에 미치는 효과)

  • Kim, Changsoo;Sung, Kijune
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.5
    • /
    • pp.69-79
    • /
    • 2011
  • This study assessed the subsurface runoff and peak flow reduction in rain gardens. The results showed that the highest water retention was found in rain garden mesocosms in which Rhododendron lateritium and Zoysia japonica were planted, followed by mesocosms in which either R. lateritium or Z. japonica was planted, and the lowest water retention rate was found in non-vegetated control treatment mesocosms(${\alpha}$ < 0.05). Although higher rainfall intensity caused a decrease of peak flow reduction in both vegetated and non-vegetated treatments, peak flow reduction was the greatest in mesocosms with mixed plants. A rain garden can be an effective tool for environment-friendly stormwater management and improving ecological functions in urban areas. Depending on the purpose such as delaying runoff or increasing infiltration, various plant types should be considered for rain garden designing.

Peripheral Blood Flow Velocity and Peripheral Pulse Wave Velocity Measured Using a Clip-type Pulsimeter Equipped with a Permanent Magnet and a Hall Device

  • Kim, Keun-Ho;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.47-51
    • /
    • 2015
  • We measured radial arterial pulse signals using a prototype of a clip-type pulsimeter equipped with a permanent magnet and a Hall device, which produced signals through a voltage-detecting circuit. The systolic peak time and the reflective peak time for a temporally pulsed signal were analyzed for an arbitrary pulse wave at one position of a small permanent magnet. The measured value of the peripheral pulse wave velocity was about 1.25-1.52 m/s, demonstrating the accuracy of this new method. To measure the peripheral blood flow velocity, we simultaneously connected the radial artery pulsimeter to a photoplethysmography meter. The average value of the peripheral blood flow velocity was about 0.27-0.50 m/s.

Identification of unit hydrograph peak behavior according to changes in precipitation scale in a virtual watershed (가상 유역의 강수 규모 변화에 따른 단위유량도 첨두치의 거동 규명)

  • Yoo, Ju-Hwan;Kim, Joo-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.10
    • /
    • pp.655-665
    • /
    • 2023
  • In this study, unit hydrographs are calculated when precipitations of 10 scales instantaneously occurs in a virtual watershed with a constant slope and roughness. Then, the relationship between the peak flow rate and the peak occurrence time of the unit hydrograph was calculated for the precipitation scale, respectively. At this time, the virtual watershed simplified with a rhombic shape, a constant slope, and a flow condition with a certain roughness was applied instead of a natural watershed in order to understand the effect the precipitation scale has on the peak value of the unit hydrograph. And it was assumed that the precipitation in the basin was effective rainfall and the runoff was direct runoff, and the runoff flowed in a straight, uniform flow from the drop point to the outlet. The relationship between the peak flow and the peak occurrence time of the unit hydrograph was calculated in the case of 10 types of precipitation scales of 10 mm, 40 mm, 90 mm, 160 mm, 250 mm, 360 mm, 640 mm, 1,000 mm, 1,210 mm, and 1,690 mm of effective precipitation. A noteworthy achievement of this study is that, even without the storage effect of the watershed, as the scale of precipitation increases, the depth of runoff increases, so the flow rate in the watershed increases and the distance per unit time increases, so the peak flow rate increases and the peak occurrence time increases. This is a nonlinear characteristic of watershed runoff.

Frequency Characteristics of Fluctuating Velocity According to Flow Rates in a Tip Leakage Vortex and a Wake Flow in an Axial Flow Fan (축류 홴의 익단누설와류 및 후류에서 유량에 따른 변동속도의 주파수 특성)

  • Jang, Choon-Man;Kim, Kwang-Yong;Fukano, Tohru
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.2
    • /
    • pp.181-188
    • /
    • 2004
  • The frequency characteristics in an axial flow fan operating at a design and three off-design operating conditions have been investigated by measuring the velocity fluctuation of a tip leakage vortex and a wake flow. Two hot-wire probe sensors rotating with the fan rotor. a fixed and a moving ones, were introduced to obtain a cross-correlation coefficient between two sensors as well as the fluctuating velocity. The results show that the spectral peaks due to the fluctuating velocity near the rotor tip are mainly observed in the reverse flow region of higher flow rates than those in the peak pressure operating condition. However, no peak frequency presents near the rotor tip for near stall condition. Detailed wake flow just downstream of the rotor blade was also measured by the rotating hot-wire sensor. The peak frequency of a high velocity fluctuation due to Karman vortex shedding in the wake region is mainly observed at the higher flow rate condition than that in the design point.