• Title/Summary/Keyword: Peak Detect

Search Result 303, Processing Time 0.028 seconds

Noise-robust electrocardiogram R-peak detection with adaptive filter and variable threshold (적응형 필터와 가변 임계값을 적용하여 잡음에 강인한 심전도 R-피크 검출)

  • Rahman, MD Saifur;Choi, Chul-Hyung;Kim, Si-Kyung;Park, In-Deok;Kim, Young-Pil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.126-134
    • /
    • 2017
  • There have been numerous studies on extracting the R-peak from electrocardiogram (ECG) signals. However, most of the detection methods are complicated to implement in a real-time portable electrocardiograph device and have the disadvantage of requiring a large amount of calculations. R-peak detection requires pre-processing and post-processing related to baseline drift and the removal of noise from the commercial power supply for ECG data. An adaptive filter technique is widely used for R-peak detection, but the R-peak value cannot be detected when the input is lower than a threshold value. Moreover, there is a problem in detecting the P-peak and T-peak values due to the derivation of an erroneous threshold value as a result of noise. We propose a robust R-peak detection algorithm with low complexity and simple computation to solve these problems. The proposed scheme removes the baseline drift in ECG signals using an adaptive filter to solve the problems involved in threshold extraction. We also propose a technique to extract the appropriate threshold value automatically using the minimum and maximum values of the filtered ECG signal. To detect the R-peak from the ECG signal, we propose a threshold neighborhood search technique. Through experiments, we confirmed the improvement of the R-peak detection accuracy of the proposed method and achieved a detection speed that is suitable for a mobile system by reducing the amount of calculation. The experimental results show that the heart rate detection accuracy and sensitivity were very high (about 100%).

A Whole Cell Bioluminescent Biosensor for the Detection of Membrane-Damaging Toxicity

  • Park, Sue-Hyung;Gu, Man-Bock
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.4 no.1
    • /
    • pp.59-62
    • /
    • 1999
  • The recombinant bacteria strain DPD2540, containing a fabA::luxCDABE fusion, was used to detect the toxicity of various chemicals in this study. Membrane damaging agents such as phenol, ethanol, and cerulenin induced a rapid bioluminescent response from this strain. Other toxic agents, such as DNA-damaging or oxidative-damaging chemicals, showed a delayed bioluminescent response in which the maximum peak appeared over 150 min after induction. This strain was also tested for measurement of toxicity in field samples such as wastewater and river water effluents.

  • PDF

Quantitative Measurement of General Odorant Using Electroantennogram of Male Silkworm Moth, Bombyx mori

  • Yun, Enug-Sik;Park, Tai-Hyun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.2
    • /
    • pp.150-152
    • /
    • 2000
  • The investigation of electroantennogram (EAG) using insect antennad has been primarily focused on the measurement of insect pheromone. Insect has highly specialized olfactroy receptors inside their antennae. In this paper, EAG was applied to detect general oborants and the feasibility of this system for the olfactroy biosensor was investigated. Electroantennogram measurement was carried out using the antennae of male silkworm moth, bombyx mori, and ammonia gas as the model odorant. EAG parametres including peak ampiltude increased linearly with the ammonia concentration and the reproducible electrical signals were generated at least for 2 hrs after the antenna was cut off from the sulkworm moth.

  • PDF

Study of Optical Transmission Performance in IP-over-WDM Networks Based on FSK/ASK Combined Modulation Format

  • Xiangjun, Xin;Andre, Paulo Sergio de Brito;Teixeira, Antonio Luis Jesus;Monteiro, Paulo P.;Rocha, Jose R. F. da
    • ETRI Journal
    • /
    • v.27 no.3
    • /
    • pp.267-272
    • /
    • 2005
  • The transmission performance of optical labeling based on a combined frequency shift keying/amplitude shift keying (FSK/ASK) format is studied by numerical simulation. The simulation demonstrates that the bit-error ratio (BER) characteristic of an ASK signal is limited by the extinction ratio, received optical power, and dispersion, simultaneously. However, an FSK signal is mainly limited by the extinction ratio (ER) and received optical power when the peak spectrum, which is used to detect the FSK signal, is relatively narrow.

  • PDF

Swing Motion of Miniaturized Humanoid Robot (소형 휴머노이드 로봇의 그네 운동)

  • 이수영;정길도;성영휘;박성훈
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.3
    • /
    • pp.267-272
    • /
    • 2004
  • In this Paper, we present analysis on the dynamics of human swing and its realization by a miniaturized humanoid robot. Since the motion of legs is the most important in the swing, the swing system can be approximated as a double pendulum. Based on Lagrangian analysis, the leg motion is designed to make the swing motion as sustained oscillation. In order to detect the peak instant of the swing and to synchronize the leg motion with the swing, we use ADXL acceleration/inclination sensor. The miniaturized humanoid in this paper has total 20 DOFs including 6 DOFs in each leg, 34cm in height, and 2kg in weight. As a result of realization of the swing by the humanoid, the sustained oscillation is verified through experiments.

A Motion Adaptive Multi-Frame Interpolation Algorithm (움직임 적응형 멀티프레임 보간 알고리즘)

  • 김희철;채종석;최철호;권병헌;최명렬
    • Proceedings of the IEEK Conference
    • /
    • 2000.06d
    • /
    • pp.54-57
    • /
    • 2000
  • In this paper, we propose a new interpolation method by using the motion between two moving image frames. In the proposed method, the movement is detected by using neighborhood pixels of target pixel in the past frame and the present frame. Then, H-shaped pseudomedian filter (below HPMED) is used for the still part of the image and Delta-shaped interpolation filter (below $\Delta$-shaped) for used in the moving part of the image. We detect the movement by comparing the differences between pixels in 4${\times}$5 window of the past frame and the present frame; the difference has a critical value. We simultaneously accomplish checking PSNR(peak signal noise ratio) and subjective assessment that is placed the focus on edge characteristic for assessment of result in computer simulation. The results show that the proposed adaptive method is better than the conventional methods.

  • PDF

A Scene Based Nonuniformity Correction Technique of Linear Array Infrared Detector (선형배열 적외선 검출기의 배경 기반 불균일 보정기법)

  • 송인태;안상호
    • Proceedings of the IEEK Conference
    • /
    • 2000.11d
    • /
    • pp.73-76
    • /
    • 2000
  • A Scene Based Technique(SBT) that corrects linear array infrared detector's nonuniformity is proposed. Basically, this technique dispenses with using temperature references on a linear array infrared detector. To correct the nonuniformity of infrared images, we use three methods. Firstly, we detect bad channels by using the information which is cumulated all the same line pixels. Secondly, a variable window method is applied to compensate more accurately. Thirdly, an adaptive method which updates gain and offset coefficient is used only on a stationary region. These results are demonstrated on a computer simulation with various images. As a result, the nonuniformity is corrected completely, so that images are enhanced and PSNR(peak signal to noise ratio) is improved much.

  • PDF

Walking Pattern Analysis Using an Acceleration Sensor Device

  • Hong, Ju-Hee;Han, Kap-Soo;Kim, Kyungho
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.396-401
    • /
    • 2017
  • In this paper, a device to analyze gait pattern was developed by using a 2-axis acceleration sensor attached to the foot. The 1st low-pass filter was adapted to limit the frequency band up to 5 Hz. An algorithm to detect the peak value exceeding the threshold voltage of an X-axis acceleration sensor and a Z-axis acceleration sensor was developed and normal and abnormal walking patterns were thus differentiated. Also, MCU and Bluetooth were combined to transfer the data to other MCUs to display on an LCD; the size of the device could then be reduced. The new algorithm and the device allowed the individual walking patterns to be easily measured at a low cost and with less restriction on activities compared to conventional multiple pressure sensors or motion camera system.

A Study on Gene Detection using Non-labeling DNA

  • Choi Yong-Sung;Lee Kyung-Sup;Kwon Young-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.10
    • /
    • pp.960-965
    • /
    • 2006
  • This research aims to develop the multiple channel electrochemical DNA chip using microfabrication technology. At first, we fabricated a high integration type DNA chip array by lithography technology. Several probe DNAs consisting of thiol group at their 5-end were immobilized on the gold electrodes. Then target DNAs were hybridized and reacted. Cyclic voltammetry showed a difference between target DNA and control DNA in the anodic peak current values. Therefore, it is able to detect a plural genes electrochemically after immobilization of a plural probe DNA and hybridization of non-labeling target DNA on the electrodes simultaneously. It suggested that this DNA chip could recognize the sequence specific genes.

Analysis of Series Arc-Fault Signals Using Wavelet Transform (웨이블렛 변환을 이용한 직렬 아크고장 신호 분석)

  • Bang, Sun-Bae;Park, Chong-Yeun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.494-500
    • /
    • 2008
  • This paper presents the analyzed result of the series arc fault current by using the discrete wavelet transform. The series arcing is caused by a loose connection in series with the load circuit. The series arc current is limited to a moderate value by the resistance of the device connected to the circuit, such as an appliance or a lighting system. The amount of energy in the sparks from the series arcing is less than in the case of parallel arcing but only a few amps are enough to be a fire hazard. Therefore, it is hard to detect the distinctive difference between a normal current and a intermittent arc current. This paper, presents the variation of the ratio of peak values and RMS values of the series arc fault current, and proposes the novel series arc fault detecting method by using the discrete wavelet transform. Loads such as a CFL lamp, a vacuum cleaner, a personal computer, and a television, which has the very similar normal current with the arc current, were selected to confirm the novel method.