• Title/Summary/Keyword: Peak Degradation

Search Result 373, Processing Time 0.031 seconds

Thermogravimetric and Fourier Transform Infrared Analysis of Switchgrass Pyrolysis (스위치그라스 열분해에 대한 TGA-FTIR 분석)

  • Lee, Seong-Beom;Fasina, Oladiran O.
    • Journal of Biosystems Engineering
    • /
    • v.34 no.1
    • /
    • pp.44-49
    • /
    • 2009
  • This study was conducted to investigate the pyrolysis characteristics of switchgrass using TGA-FTIR instrument. Switchgrass is a high yielding perennial grass that has been designated as a potential energy crop, because of its high energy value. Ground switchgrass were pyrolysed at different heating rates of 10, 20, 30, and $40^{\circ}C/min$ in a TGA-FTIR instrument. The thermal decomposition characteristics of switchgrass were analyzed, and the gases volatilized during the experiment were identified. The thermal decomposition of switchgrass started at approximately $220^{\circ}C$, followed by a major loss of weight, where the main volatilization occurred, and the thermal decomposition was essentially completed by $430^{\circ}C$. The pyrolysis process was found to compose of four stages; moisture evaporation, hemicellulose decomposition, cellulose decomposition, and lignin degradation. The peak temperatures for hemicellulose decomposition ($306^{\circ}C$ to $327^{\circ}C$) and cellulose decomposition ($351^{\circ}C$ to $369^{\circ}C$) were increased with greater heating rates. FTIR analysis showed that the following gases were released during the pyrolysis of switchgrass; $CO_2$, CO, $CH_4$, $NH_3$, COS, $C_{2}H_{4}$, and some acetic acid. The most gas species were released at low temperature from 310 to $380^{\circ}C$, which was corresponding well with the observation of thermal decomposition.

Retention and Fatigue Properties of MFS Devices using Ferroelectric $LiMbO_3$ Thin Films ($LiMbO_3$ 강유전체 박막을 이용한 MFS 디바이스의 Retention 및 Fatigue 특성)

  • 정순원;김채규;김용성;김진규;이남열;김광호;유병곤;이원재
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.17-20
    • /
    • 1999
  • The retention and fatigue properties of ferroelectric LiNbO$_3$ thin films were studied. Metal-ferroelectric-semiconductor(MFS) devices by using rapid thermal annealed LiNbO$_3$/Si structures were successfully fabricated and demonstrated nonvolatile memory operations of the MFS devices. The I$_{D}$-V$_{G}$ characteristics of MFSFET\`s showed a hysteresis loop due to the ferroelectric nature of the LiNbO$_3$ thin film. The ferroelectric capacitors showed practically no polarization degradation up to about 10$^{10}$ switching cycles when subjected to symmetric bipolar voltage pulse (peak-to-peak 6V, 50% duty cycle) in the 500kHz. The retention properties of the LiNbO$_3$ thin films were quite good up to about 10$^{3}$ s . s .

  • PDF

A Simple Human Visual Weighted Hadamard Transform Image Coding (단순한 시각적 하중에 의한 아다마르 영상부호화)

  • Hwang, Jae-Jeong;Lee, Moon-Ho
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.4
    • /
    • pp.98-105
    • /
    • 1989
  • Various models incorporating Human Visual System (HVS) with the Hadamard transform (HT) represented by Walsh functions are considered. Using the exact frequency components of HT basis functions, the optimum modulation transfer function (MTF) which has a higher peak frequency than DCT schemes is obtimum modulation transfer function (MTF) which has a higher peak frequency than DCT schemes is obtained analytically and visually. The main criterion, for error measurement, is errors at the block boundaries which is an important factor in transform coding. The scheme which has no inverse HVS is proposed. It causes some degradation of image data but it is insignigicant. Crossing area of 4 blocks is equalized by the HVS weighting coefficients. The HVS weighted coding results in perceptually higher quality images compared with the unweighted scheme.

  • PDF

Degradation of OFDM Signal Performance by Chromatic Dispersion in a Several 10 Gbit/s Mobile Front-haul Link (수 10 Gbit/s 모바일 프론트홀 링크에서 색분산에 의한 OFDM 신호 전송성능 열화 분석)

  • Won, Yong-Yuk;Seo, Dongsun
    • Journal of IKEEE
    • /
    • v.20 no.1
    • /
    • pp.26-30
    • /
    • 2016
  • In this paper, an inter-orthogonal frequency division multiplexing (OFDM) sub-carrier distortion due to fiber chromatic dispersion is investigated. The fiber chromatic dispersion induces phase difference among OFDM sub-carriers, resulting in non-symmetric peak to average power ratio (PAPR) inducing inter-OFDM distortion. Experiments to confirm the fiber dispersion are performed in a direct-detection optical front-haul link. Quadrature phase shift keying (QPSK) encoded OFDM symbols at 25 Gbit/s are transmitted over 100 km fiber and the resulting error vector magnitude (EVM) of 40 % is observed.

A Study on Efficient Interpolation Method in Salt & Pepper Noise Environments (Salt & Pepper 잡음 환경에서 효율적인 보간법에 관한 연구)

  • Ko, You-Hak;Kwon, Se-Ik;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.681-683
    • /
    • 2017
  • In the digital information age, image processing is essential for various digital devices such as smart phones, cameras, and TVs. However, degradation occurs in analyzing, recognizing, and processing image data, and salt & pepper noise occurs. Therefore, in this paper, we applied linear interpolation method, newton interpolation method, lagrange interpolation method, and spline interpolation method to the image damaged by salt & pepper noise in order to find more effective interpolation method in salt & pepper noise environment, The methods were compared using the PSNR (peak signal to noise ratio).

  • PDF

Strength and mechanical behaviour of coir reinforced lime stabilized soil

  • Sujatha, Evangelin Ramani;Geetha, A.R.;Jananee, R.;Karunya, S.R.
    • Geomechanics and Engineering
    • /
    • v.16 no.6
    • /
    • pp.627-634
    • /
    • 2018
  • Soil stabilization is an essential engineering process to enhance the geotechnical properties of soils that are not suitable for construction purposes. This study focuses on using coconut coir, a natural fibre to enhance the soil properties. Lime, an activator is added to the reinforced soil to augment its shear strength and durability. An experimental investigation was conducted to demonstrate the effect of coconut coir fibers and lime on the consistency limits, compaction characteristics, unconfined compressive strength, stress-strain behaviour, subgrade strength and durability of the treated soil. The results of the study illustrate that lime stabilization and coir reinforcement improves the unconfined compressive strength, post peak failure strength, controls crack propagation and boosts the tensile strength of the soil. Coir reinforcement provides addition contact surface, improving the soil-fibre interaction and increasing the interlocking between fibre and soil and thereby improve strength. Optimum performance of soil is observed at 1.25% coir fibre inclusion. Coir being a natural product is prone to degradation and to increase the durability of the coir reinforced soil, lime is used. Lime stabilization favourably amends the geotechnical properties of the coir fibre reinforced soil.

Analysis of hysteresis rule of energy-saving block and invisible multi-ribbed frame composite wall

  • Lin, Qiang;Li, Sheng-cai;Zhu, Yongfu
    • Structural Engineering and Mechanics
    • /
    • v.77 no.2
    • /
    • pp.261-272
    • /
    • 2021
  • The energy-saving block and invisible multi-ribbed frame composite wall (EBIMFCW) is a new type of load-bearing wall. The study of this paper focus on it is hysteresis rule under horizontal cyclic loading. Firstly, based on the experimental data of the twelve specimens under horizontal cyclic loading, the influence of two important parameters of axial compression ratio and shear-span ratio on the restoring force model was analyzed. Secondly, a tetra-linear restoring force model considering four feature points and the degradation law of unloading stiffness was established by combining theoretical analysis and regression analysis of experimental data, and the theoretical formula of the peak load of the EBIMFCW was derived. Finally, the hysteretic path of the restoring force model was determined by analyzing the hysteresis characteristics of the typical hysteresis loop. The results show that the curves calculated by the tetra-linear restoring force model in this paper agree well with the experimental curves, especially the calculated values of the peak load of the wall are very close to the experimental values, which can provide a reference for the elastic-plastic analysis of the EBIMFCW.

Analysis of X-Band Link Performance Degradation Caused by Adjacent Satellite

  • Park, Durk-Jong;Ahn, Sang-Il;Chun, Yong-Sik;Kim, Eun-Kyou
    • Journal of Astronomy and Space Sciences
    • /
    • v.28 no.4
    • /
    • pp.299-304
    • /
    • 2011
  • As more satellites are designed to downlink their observed image data through the X-band frequency band, it is inevitable that the occupied bandwidth of a target satellite will overlap with that of other X-band downlink satellites. For sun-synchronized low earth orbit satellites, in particular, it can be expected that two or more satellites be placed within the looking angle of a ground station antenna at the same time. Due to the overlapping in the frequency band, signals transmitted from the adjacent satellites act as interferers, leading to degraded link performance between target satellite and ground station. In this paper, link analysis was initiated by modeling the radiation pattern of ground station antenna through a validated Jet Propulsion Laboratory peak envelope model. From the relative antenna gain depending on the offset angle from center axis of maximum antenna directivity, the ratio of received interference signal level to the target signal level was calculated. As a result, it was found that the degradation increased when the offset angle was within the first point of radiation pattern. For a 7.3 m antenna, serious link degradation began at an offset angle of 0.4 degrees. From this analysis, the link performance of the coming satellite passes can be recognized, which is helpful to establish an operating procedure that will prevent the ground station from receiving corrupted image data in the event of a degraded link.

Characterization of Fe-ACF/$TiO_2$ composite Photocatalysts Effect Via Degradation of MB Solution (Fe-ACF/$TiO_2$ 복합체의 특성과 MB용액의 분해에서 포토-펜톤 효과)

  • Zhang, Kan;Meng, Ze-Da;Ko, Weon-Bae;Oh, Won-Chun
    • Elastomers and Composites
    • /
    • v.44 no.3
    • /
    • pp.290-298
    • /
    • 2009
  • In this paper, the Fe-activated carbon fiber (ACF)/$TiO_2$ composite catalysts were prepared by a sol-gel method. The synthesized photocatalysts were used for the photo degradation of Methylene blue solution under UV light. From Brunauer-Emmett-Teller measurements (BET) data, it was shown the blocking of the micropores on the surface of ACF by treatment of Fe and Ti compound. As shown in SEM images, the ferric compounds and titanium dioxides were fixed onto the ACF surfaces. The result of X-ray powder diffraction showed that the crystal phase contained a mixing anatase and rutile structure and the 'FeO+$TiO_2$' from the composites. The EDX spectra for the elemental analysis showed the presence of C, O, and Ti with Fe peaks. Degradation activity of MB could be attributed to +OH radicals derived from electron/hole pair's reactions due to photolysis of $TiO_2$ and photo-Fenton effect of Fe.

An Analysis on Performance Degradation of Silicon Photomultipliers over Temperatures Variation for PET-MR Application (PET-MR 시스템에 적용을 위한 실리콘 광증배센서의 온도 변화에 따른 성능 열화 분석)

  • Park, Kyeongjin;Kim, Hyoungtaek;Lim, Kyungtaek;Cho, Minsik;Kim, Giyoon;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.143-151
    • /
    • 2015
  • A PET-MR system is particularly useful in diagnosing brain diseases. We have developed a prototype positron emission tomography (PET) system which can be inserted into the bore of a whole-body magnetic resonance imaging (MRI) system that enables us to obtain PET and MRI images simultaneously with a reduced cost. Silicon photomultipliers (SiPM) are appropriated as a PET detector at PET/MR system because detectors have a high gain and are insensitive to magnetic fields. Despite of its improved performance compared to that of PMT-based detectors, there is a problem of the photo-peak channel shift which is due to the increase of the temperature inside the ring detector. This problem will occur decreasing sensitivity of the PET and image distortion. In this paper, I quantitative analyze parameters of the KAIST SiPM depending on temperature by experiments. And I designed cooling methods in consideration of the degradation of sensors for correction of the temperature in the PET gantry. According to this research, we expect that distortive images and degradation of the sensitivity will not be occurred with using the above idea to reduce heat even if the PET system operates for a long time.