• Title/Summary/Keyword: Patterns of failure

Search Result 599, Processing Time 0.034 seconds

A Study on the Optimal Operation and Policy of the Boryeong Dam Diverion Pipe Line Using the SWAT Model (SWAT 모형을 이용한 보령댐 도수로 운영 방안 및 정책 연구)

  • Park, Bumsoo;Yoon, Hyo Jik;Hong, Yong Seok;Kim, Sung Pyo
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.546-558
    • /
    • 2020
  • While industrialization has provided in abundance, the pollution it creates has caused untold damage to the environment, increasing the frequency and severity of natural disasters through changes in global climate patterns. The World Risk Forum's (WEF) World Risk Report presented the results of a survey of experts from around the world detailing the most influential risk factors over the next decade. Notably, the failure to respond to climate change ranked first and the global water crisis third. The extreme drought in the western Chungnam province was unexpected in 2016. At the time, the water level of Boryeong Dam was drastically decreased due to receiving less than half the average recorded rainfall in the region that year. The Boryeong Dam diversion pipeline has the capacity to solve the water shortage problem between these two regions by providing water from Geumgang to the western part of Chungnam, including Boryeong City. Current weather trends suggest drought is likely to continue in western Chungnam, which uses the Boryeong Dam as an intake source. This makes it necessary to operate Boryeong Dam diversion pipeline in an efficient and effective manner. SWAT is a watershed scale model developed to predict the impact of land management practices on water. The SWAT model was used in this study to evaluate the adequacy of the Boryeong Dam diversion pipeline operational plan by comparing it to present Boryeong Dam diversion pipeline operation. By investigating the number of days required to reach each reservoir stage, we determined that the number of days required to reach the boundary stage was less than that of the current operation. This determination accounts for the caveats that the Boryeong Dam waterway was not operated and only one pump will be operated from October to May of next year. As our results suggest, the most stable operation scenario is to operate two pumps at all times. This can be accomplished by operating two pumps from the caution stage to increase the number of pumps whenever the stage is raised. In addition to the stable operation of the Boryeong Dam pipeline, policy considerations are required with regard to imposing a water use charge on users of the Boryeong Dam region.

Fractal Analysis of Peri-Implant Bone Mineral Density before and after Functional Loading on Implant (기능하중에 따른 임플란트 주변 골밀도의 변화에 대한 프렉탈 구조 분석)

  • Hong, Seong-Wan;Lee, Jae-In;Cho, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.359-370
    • /
    • 2011
  • To identify osseointegration of implants, dentists were performed the radiographic analysis. The fractal analysis methods using periapical radiographs before and after loading on implants was to evaluate whether or not significant. 30 patients who were placed implants in dental hospital of Wonkwang university were participated in this study. Total of 42 implants were analyzed. And, 14 males and 16 females aged from 22 to 73 participated in this study. The two morphologic and Fractal analysis of the one trabecular patterns in alveolar bone were done using periapical views. Two periapical views, after implant placement, and after 2 months of functional loading were analysed. The analysis was done by software, Image J(1.40s, National Institute of Health, Bethesda, USA). The data were statistically analyzed using one-way ANOVA(P<.05). Multiple comparison was done by the Tukey HSD test. The results of Fractal analysis and change in bone density around implants showed significantly different values, especially mandibles. However, in case of implants with failure, Fractal values decreased from 1.2865 to 1.1521 and 1.1135 to 1.0478.

Maximising the lateral resolution of near-surface seismic refraction methods (천부 탄성파 굴절법 자료의 수평 분해능 최대화 연구)

  • Palmer, Derecke
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.85-98
    • /
    • 2009
  • The tau-p inversion algorithm is widely employed to generate starting models with most computer programs, which implement refraction tomography. This algorithm emphasises the vertical resolution of many layers, and as a result, it frequently fails to detect even large lateral variations in seismic velocities, such as the decreases which are indicative of shear zones. This study demonstrates the failure of the tau-p inversion algorithm to detect or define a major shear zone which is 50m or 10 stations wide. Furthermore, the majority of refraction tomography programs parameterise the seismic velocities within each layer with vertical velocity gradients. By contrast, the Generalized Reciprocal Method (GRM) inversion algorithms emphasise the lateral resolution of individual layers. This study demonstrates the successful detection and definition of the 50m wide shear zone with the GRM inversion algorithms. The existence of the shear zone is confirmed by a 2D analysis of the head wave amplitudes and by numerous closely spaced orthogonal seismic profiles carried out as part of a later 3D refraction investigation. Furthermore, an analysis of the shot record amplitudes indicates that a reversal in the seismic velocities, rather than vertical velocity gradients, occurs in the weathered layers. The major conclusion reached in this study is that while all seismic refraction operations should aim to provide as accurate depth estimates as is practical, those which emphasise the lateral resolution of individual layers generate more useful results for geotechnical and environmental applications. The advantages of the improved lateral resolution are obtained with 2D traverses in which the structural features can be recognised from the magnitudes of the variations in the seismic velocities. Furthermore, the spatial patterns obtained with 3D investigations facilitate the recognition of structural features such as faults which do not display any intrinsic variation or 'signature' in seismic velocities.

Treatment outcomes of radiotherapy for anaplastic thyroid cancer

  • Park, Jong Won;Choi, Seo Hee;Yoon, Hong In;Lee, Jeongshim;Kim, Tae Hyung;Kim, Jun Won;Lee, Ik Jae
    • Radiation Oncology Journal
    • /
    • v.36 no.2
    • /
    • pp.103-113
    • /
    • 2018
  • Purpose: Anaplastic thyroid cancer (ATC) is a rare tumor with a lethal clinical course despite aggressive multimodal therapy. Intensity-modulated radiotherapy (IMRT) may achieve a good therapeutic outcome in ATC patients, and the role of IMRT should be assessed. We retrospectively reviewed outcomes for ATC treated with three-dimensional conformal radiotherapy (3D-CRT) or IMRT to determine the optimal treatment option and explore the role of radiotherapy (RT). Materials and Methods: Between December 2000 and December 2015, 41 patients with pathologically proven ATC received RT with a sufficient dose of ${\geq}40Gy$. Among them, 21 patients (51%) underwent surgery before RT. Twenty-eight patients received IMRT, and 13 received 3D-CRT. Overall survival (OS) and progression-free survival (PFS), patterns of failure, and toxicity were examined. Results: The median follow-up time for survivors was 38.0 months. The median and 1-year OS and PFS rates were 7.2 months and 29%, 4.5 months and 15%, respectively. Surgery significantly improved the prognosis (median OS: 10.7 vs. 3.9 months, p = 0.001; median PFS: 5.9 vs. 2.5 months, p = 0.007). IMRT showed significantly better PFS and OS than 3D-CRT, even in multivariate analysis (OS: hazard ratio [HR] = 0.30, p = 0.005; PFS: HR = 0.33, p = 0.005). Significantly higher radiation dose could be delivered with IMRT than 3D-CRT ($EQD2_{10}$ 66 vs. 60 Gy, p = 0.005). Only 2 patients had grade III dermatitis after IMRT. No other severe toxicity ${\geq}grade$ III occurred. Conclusion: Patients with ATC showed better prognosis through multimodal treatment. Furthermore, IMRT could achieve favorable survival rates by safely delivering higher dose than 3D-CRT.

MICROTENSILE BONDING OF ONE-STEP ADHESIVES TO SHEARED AND NON-SHEARED DENTIN (도말층 존재 유무에 따른 One-step 접착 시스템의 미세인장결합강도)

  • Song, Yong-Beom;Jin, Jeong-Hee;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.3
    • /
    • pp.299-309
    • /
    • 2002
  • The purposes of this study were to evaluate the microtensile bond strength of one-step adhesives accord ing to various dentin surface treatments and to observe the interface between resin(Z-100$^{TM}$) and dentin under SEM. In this study forty-five non-caries extracted human molars and three adhesive systems were used ; AlI-Bond 2(AB), One-Up Bond F(OU), AQ-Bond(AQ). ; In Group 1, 2, 3, AB was used and tooth surfaces were treated by smearing(S), ultrasonic cleansing(US), etching(E) respectively. In Group 4. 5, 6, One-Up Bond F was used and tooth surfaces were also treated as the same way above. In Groups 7, 8, 9, AQ Bond was used and tooth surfaces wet$.$e treated as the same way. Each specimen was prepared for microtensile bond testing, and were stored for 24hrs in 37$^{\circ}C$ distilled water. After that, microtensile bond strength for each specimen was measured. Specimens were fabricated to examine the failure patterns of interface between resin and dentin and observed under the SEM. The results were as follows ; 1. The results(mean$\pm$SD) of microtensile test were group 1, 25.69$\pm$4.31MPa; group 2, 40.93$\pm$10.94MPa; group 3, 47.65$\pm$8.85MPa; group 4, 35.98$\pm$9.14MPa; group 5, 39.66$\pm$8.45MPa; group 6, 43.26$\pm$13.01MPa; group 7, 25.07$\pm$4.2MPa;group 8, 30.4$\pm$4.74MPa;group 9, 33.61$\pm$7.88MPa. 2. One-Up Bond F was showed the highest value of 36.98$\pm$9.14MPa in dentin surface treatment with smearing, and there were significant differences to the other groups (p<0.05). 3. All-Bond 2 was showed the highest value of 40.93$\pm$10.94MPa in dentin surface treatment with ultra-sonic cleansing, but was no significant difference to One-Up Bond F(p>0.05) 4. All-Bond 2 was showed the highest value of 47.65$\pm$8.85MPa in dentin surface treatment with etch ing(10%phosphoric acid), and there were significant differences to the other groups(p<0.05). 5. All-Bond 2 was showed the highest value of 47.65$\pm$8.85MPa in dentin surface treatment according to manufacture's directions. but was no significant difference to One-Up Bond F(p>0.05). 6. AQ Bond was skewed the lowest microtensile bond strength with various dentin surface treatment, and the were significant differences to the other groups(p<0.05).

Bond Behavior of Epoxy Coated Reinforcement Using Direct Pull-out Test and Beam-End Test (직접인발시험과 보-단부 시험을 이용한 에폭시 도막 철근의 부착특성)

  • Kim, Jee-Sang;Kang, Won Hyeak
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.3
    • /
    • pp.271-278
    • /
    • 2019
  • The corrosion of reinforcements embedded in concrete causes severe deterioration in reinforced concrete structures. As a countermeasure, epoxy coated reinforcements are used to prevent corrosion of reinforcements. When epoxy coated bars are used, the resistance of corrosion is excellent, but epoxy coating on the bars have a disadvantage of reduction in bond capacity comparing to that of normal bars. Therefore, it is necessary to confirm the bond performance of epoxy coated reinforcements through experimental and analytical methods. Bond behaviors of epoxy coated bars for various diameters of 13 and 19mm and thicknesses of cover concrete of 3 types(ratio of cover to bar diameter) are examined. As the diameters of the epoxy coated bars increase, the difference of bond strength between epoxy coated and uncoated bars also increases and damage patterns showed pull out failure. In addition, finite element analysis was performed based on the bond-slip relationship obtained by direct pullout test and compared with the flexural test results. It is considered that flexural member test is more useful than pullout test for simulating the behavior of actual structure.

Cat Behavior Pattern Analysis and Disease Prediction System of Home CCTV Images using AI (AI를 이용한 홈CCTV 영상의 반려묘 행동 패턴 분석 및 질병 예측 시스템 연구)

  • Han, Su-yeon;Park, Dea-woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.165-167
    • /
    • 2022
  • The proportion of cat cats among companion animals has been increasing at an average annual rate of 25.4% since 2012. Cats have strong wildness compared to dogs, so they have a characteristic of hiding diseases well. Therefore, when the guardian finds out that the cat has a disease, the disease may have already worsened. Symptoms such as anorexia (eating avoidance), vomiting, diarrhea, polydipsia, and polyuria in cats are some of the symptoms that appear in cat diseases such as diabetes, hyperthyroidism, renal failure, and panleukopenia. It will be of great help in treating the cat's disease if the owner can recognize the cat's polydipsia (drinking a lot of water), polyuria (a large amount of urine), and frequent urination (urinating frequently) more quickly. In this paper, 1) Efficient version of DeepLabCut for posture prediction running on an artificial intelligence server, 2) yolov4 for object detection, and 3) LSTM are used for behavior prediction. Using artificial intelligence technology, it predicts the cat's next, polyuria and frequency of urination through the analysis of the cat's behavior pattern from the home CCTV video and the weight sensor of the water bowl. And, through analysis of cat behavior patterns, we propose an application that reports disease prediction and abnormal behavior to the guardian and delivers it to the guardian's mobile and the main server system.

  • PDF

A Development of Analysis System for Vessel Traffic Display and Statistics based on Maritime-BigData (해상-빅데이터 기반 선박 항적 표시 및 해상교통량 통계 분석 시스템의 개발)

  • Hwang, Hun-Gyu;Kim, Bae-Sung;Shin, Il-Sik;Song, Sang-Kee;Nam, Gyeung-Tae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.6
    • /
    • pp.1195-1202
    • /
    • 2016
  • Recently, a lot of studies that applying the big data technology to various fields, are progressing actively. In the maritime domain, the big data is the meaningful information which makes and gathers by the navigation and communication equipment from the many ships on the ocean. Also, importance of the maritime safety is emphasized, because maritime accidents are rising with increasing of maritime traffic. To support prevention of maritime accidents, in this paper, we developed a vessel traffic display and statistic system based on AIS messages from the many vessels of maritime. Also, to verify the developed system, we conducted tests for vessel track display function and vessel traffic statistic function based on two test scenarios. Therefore, we verified the effectiveness of the developed system for vessel tracks display, abnormal navigation patterns, checking failure of AIS equipments and maritime traffic statistic analyses.

Results of Radiation Therapy in Nasopharyngeal Cancer (비인강암의 방사선치료 성적)

  • Cho Moon-June;Jang Ji-Young;Kim Jun-Sang;Kim Byung-Kook;Song Chang-Joon;Kim Jae-Sung
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.10-15
    • /
    • 2001
  • Purpose : This is a retrospective study to evaluate the results of radiation therapy in nasopharyngeal carcinoma. Materials and Methods : From September 1989 to October 1996, 19 patients with nasopharyngeal carcinoma completed planned radiation therapy course. Stages were 1 in 2 patients, II in 6, III in 2 IV in 9 patients, respectively. Pathology was squamous cell carcinoma in 5 patients, undifferentiated cell carcinoma in 14 patients. Fourteen patients were treated with radiation therapy only. Five patients received chemotherapy. The follow-up period ranged from 5 months to 115 months with a median of 33 months. Follow-up was possible in all patients. Results : Responses to radiation therapy were complete response in 15 patients, partial response in 2, and no response in 2, respectively. Patterns of failure were as follows : locoregional recurrence in 6 patients and distant metastasis in 4 patients. The sites of distant metastasis were bone, liver and lung. Five year survival rate was $47.8\%$ and five year disease free survival rate was $48.1\%$. Stage, T-stage, N-stage, central nervous system involvement, pathology type, performance status, response, radiation dose, chemotherapy were not significant prognostic factors. Conclusion : 5-year survival rate was $47.8\%$ and 5-year disease free survival rate was $48.1\%$. The advances in radiation therapy techniques and chemotherapy are needed.

  • PDF

A Design of Timestamp Manipulation Detection Method using Storage Performance in NTFS (NTFS에서 저장장치 성능을 활용한 타임스탬프 변조 탐지 기법 설계)

  • Jong-Hwa Song;Hyun-Seob Lee
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.6
    • /
    • pp.23-28
    • /
    • 2023
  • Windows operating system generates various logs with timestamps. Timestamp tampering is an act of anti-forensics in which a suspect manipulates the timestamps of data related to a crime to conceal traces, making it difficult for analysts to reconstruct the situation of the incident. This can delay investigations or lead to the failure of obtaining crucial digital evidence. Therefore, various techniques have been developed to detect timestamp tampering. However, there is a limitation in detection if a suspect is aware of timestamp patterns and manipulates timestamps skillfully or alters system artifacts used in timestamp tampering detection. In this paper, a method is designed to detect changes in timestamps, even if a suspect alters the timestamp of a file on a storage device, it is challenging to do so with precision beyond millisecond order. In the proposed detection method, the first step involves verifying the timestamp of a file suspected of tampering to determine its write time. Subsequently, the confirmed time is compared with the file size recorded within that time, taking into consideration the performance of the storage device. Finally, the total capacity of files written at a specific time is calculated, and this is compared with the maximum input and output performance of the storage device to detect any potential file tampering.