• 제목/요약/키워드: Pattern of Noise Factor Frequency

검색결과 16건 처리시간 0.025초

다구찌 기법의 잡음인자 수준 정하는 기법 제안 (Propose to new Method determining level of Noise Factor of Taguchi Method)

  • 이상복
    • 한국품질경영학회:학술대회논문집
    • /
    • 한국품질경영학회 2009년도 추계학술대회
    • /
    • pp.317-323
    • /
    • 2009
  • In this paper, we propose new methods which is to determine level of noise factor. Even Taguchi give level of noise factor which is best(or maximum) and worst(or minimum) condition, we give level of noise factor which is representative value by observing noise factor frequency. Sometimes level of noise factor is given one, two and three. We know this method is more fit in real fields.

  • PDF

다양한 확률분포 하에서 다구찌 기법의 잡음인자 수준 정하는 기법 (Method determining level of Noise Factor of Taguchi Method under various probability distribution)

  • 이상복
    • 품질경영학회지
    • /
    • 제37권4호
    • /
    • pp.10-15
    • /
    • 2009
  • In this paper, we propose new methods which is to determine level of noise factor. Even Taguchi give level of noise factor which is best(or maximum) and worst(or minimum) condition, we give level of noise factor which is representative value by observing noise factor frequency. Sometimes level of noise factor is given one, two and three. We know this method is more fit in real fields.

Development of indirect EFBEM for radiating noise analysis including underwater problems

  • Kwon, Hyun-Wung;Hong, Suk-Yoon;Song, Jee-Hun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제5권3호
    • /
    • pp.392-403
    • /
    • 2013
  • For the analysis of radiating noise problems in medium-to-high frequency ranges, the Energy Flow Boundary Element Method (EFBEM) was developed. EFBEM is the analysis technique that applies the Boundary Element Method (BEM) to Energy Flow Analysis (EFA). The fundamental solutions representing spherical wave property for radiating noise problems in open field and considering the free surface effect in underwater are developed. Also the directivity factor is developed to express wave's directivity patterns in medium-to-high frequency ranges. Indirect EFBEM by using fundamental solutions and fictitious source was applied to open field and underwater noise problems successfully. Through numerical applications, the acoustic energy density distributions due to vibration of a simple plate model and a sphere model were compared with those of commercial code, and the comparison showed good agreement in the level and pattern of the energy density distributions.

위상 잡음을 개선한 CMOS VCO의 설계 및 제작 (The Design and Fabrication of Reduced Phase Noise CMOS VCO)

  • 김종성;이한영
    • 한국전자파학회논문지
    • /
    • 제18권5호
    • /
    • pp.539-546
    • /
    • 2007
  • 본 논문에서는 온-칩 스파이럴 인덕터 해석에 대한 3차원 전자장 시뮬레이션 방법을 제시하였으며, 이 방법은 정확히 예측 가능한 CMOS VCO를 설계하는데 적용될 수 있음을 보였다. VCO는 CMOS 0.25 um 표준 공정을 이용하여 LC-공진형으로 구현하였으며, 공진기의 스파이럴 인덕터는 실리콘 기판과의 사이에 그라운드 패턴을 삽입한 경우와 그렇지 않은 경우에 대해 각각 VCO를 구현하여 인덕터의 Q값 개선에 의해 VCO의 위상 잡음이 어느 정도 개선되는지를 검증하였다. 제작된 VCO는 2.5 V 제어 전압에서 3.094 GHz, -12.15 dBm 출력을 가지며, LC 공진에 사용된 단일 인덕터의 Q는 그라운드 패턴을 삽입한 경우 3 GHz에서 8% 정도 개선됨을 시뮬레이션을 통해 검증하였으며, 이로 인한 위상 잡음은 3 MHz 오프셋 주파수에서 9 dB 개선되어짐을 실험을 통해 확인하였다.

소실모형주조용 진동장치의 동특성 분석 및 설계 (Analysis of Dynamics Characteristics and Design of vibrating Table for Expendable Pattern Casting Process)

  • 이은경;설진수;임경화;이경환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.269-274
    • /
    • 2003
  • Vibration table is required to obtain high packing density in expendable pattern casting process. Packing density, which is an important manufacture factor, depends on the vibration pattern induced by vibration table. Modal test is utilized to identify the dynamic characteristics of vibration table. And finite element method is used to modify flask by fixing the stiffener. The positions of stiffener to modify are found and the natural frequency could be easily shifted to the objective value by using sensitivity analysis.

  • PDF

냉장고 정상상태 소음의 음질 인덱스 개발을 위한 심리음향학적 연구 (Psychoacoustical Study for Sound Quality Index of Steady State Noise of Refrigerators)

  • 공경수;정의봉;김태훈;신대식;안세진
    • 한국소음진동공학회논문집
    • /
    • 제26권5호
    • /
    • pp.536-545
    • /
    • 2016
  • Household refrigerator radiates noise of which the pattern is dependent on the operating condition of its parts, such as compressor, flow fans, etc. Thus the refrigerator noise has a variety of frequency characteristics. Therefore, it is required to consider the noise characteristics for evaluating the noise quality and eventually developing the sound quality index of the refrigerator noise. In this study, five units of household refrigerator were selected to measure their noises that were used to generate sound sources for jury test of the study. The measured noises of five refrigerators were divided into ten kinds of sound source by considering operating condition and frequency characteristics. Additionally, the ten sources were each edited to have the same SPL of 30 dBA. Totally twenty kinds of sound sources (10-original SPL, 10-edited SPL 30 dBA) were evaluated by twenty-two subjects, and compared with their sound quality metrics. It was found that only the loudness of the metrics was meaningfully correlated with the subjective evaluation. The rests, sharpness, roughness and fluctuation strength, were not related. The conclusion of this study is that a new sophisticated index is necessary to be developed to qualitatively evaluate the household refrigerator noise.

물에 잠긴 다공 직사각평판의 실험적 모드 해석 (Experimental Modal Analysis of Perforated Rectangular Plates Submerged In Water)

  • 유계형;이명규;정경훈;이성철
    • 한국소음진동공학회논문집
    • /
    • 제13권1호
    • /
    • pp.70-78
    • /
    • 2003
  • This paper dealt with an experimental study on the hydroelastic vibration of clamped perforated rectangular plates submerged in water. The penetration of holes in the plates had a triangular pattern with P/D (pitch to diameter) 1.750, 2.125, 2.500, 3.000 and 3.750. The natural frequencies of the perforated plates in air were obtained by the analytical method based on the relation between the reference kinetic and maximum potential energy and compared with the experimental results. Good agreement between the results was found for the natural frequencies of the perforated plates in air. It was empirically found that the natural frequencies of the perforated plate in air increase with an increase of P/D, on the other hand, the natural frequencies of the perforated plate in contact with water decrease with an increase of P/D. Additionally. the effect of the submerged depth on the natural frequency was investigated.

자동차 드럼 브레이크의 스퀼 전산 해석 연구 (Computational Study of Automotive Drum Brake Squeal)

  • 정택수;조종두
    • 한국자동차공학회논문집
    • /
    • 제22권7호
    • /
    • pp.16-22
    • /
    • 2014
  • Automotive NVH on brake operation is mainly caused by a coupling action of vehicle speed and inter parts friction and its frequency occurs over a broad band of 0.1 kHz~10 kHz. Especially, squeal noise, being a self-excited vibration generated by friction force between drum and lining, occurs over 1 kHz and consequently dynamic instability is induced when friction energy is applied to a brake vibration system. The squeal strongly depends on nonlinear properties influenced by the material of lining, velocity of vehicle, and the dynamic properties of a brake system. The dynamic properties are considered as a main influential design factor to squeal noise, however the analysis of the properties are rarely facilitated due to arbitrariness of shape by wearing down. In this paper, we research generating tendency of squeal noise through complex eigenvalue analysis, tracking drum brake's unstable modes in accordance with the wear shape of drum and lining such as tapered and bellmouth shape, and analyze computed unstable modes by variable shapes.

재가노인과 시설노인의 수면양상에 대한 비교연구 (Comparison of Sleep Patterns between Home and Institute Elderly People)

  • 김귀분;석소현;김인숙
    • 동서간호학연구지
    • /
    • 제5권1호
    • /
    • pp.65-74
    • /
    • 2000
  • This study was attempted to show basic data for search of nursing intervention about sleep improving in home and institute elderly peoples. Research design was cross-sectional survey method for comparison of sleep patterns and another variables between home and institute elderly peoples. Subjects were sampled by purpose as home and institute elderly peoples at age of 65 or older in Seoul or nearly. The survey questionnaire was used by modification of sleep questionnaire which Kim, O, Song & Bak(1997) developed. Data were collected between December, 1999 and April, 2000. And data were analyzed by SPSS PC+ for purpose of research. Results are as follows: 1. Home and institute elderly peoples, all were change of sleep patterns and sleep pattern was showed early sleeping down. But institute elderly peoples slept earlier than home elderly peoples. 2. As rest of morning, difficulty of falling asleep and disturbance of re-asleep, subjective thinking and feeling were showed more negative thing home elderly peoples than institute elderly peoples. As frequency of falling asleep within 5 min in 1 week, frequency of falling asleep over 30 min in 1 week and frequency of awakening in a day, objective frequency were showed more insomnia institute elderly peoples than home elderly peoples. Home elderly peoples didn't nap most and institute elderly peoples napped on very short time. 3. Regarding sleep-disturbing factors, physical factor was popularly joint-disturbance in all, home and institute elderly peoples. Environmental factor was popularly noise, particularly institute elderly peoples. Emotional factor wasn't all. 4. Practiced strategies for better sleep was popularly TV/Radio in home elderly peoples and were popularly regular sleep and religious action in institute elderly peoples. From the results of this study, home elderly peoples need nursing intervention of improving self-satisfaction on sleep and institute elderly peoples need nursing intervention of decreasing falling asleep-disturbing and decreasing frequency of awakening in sleep.

  • PDF

선택적으로 성장 시킨 다중 전극판을 갖는 다자유 IPMC 작동기 (MDOF Ionic-Polymer-Metal-Composite Actuators with Selectively Grown Multiple Electrodes)

  • 전진한;오일권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.294-298
    • /
    • 2008
  • The ionic polymer-metal composite actuators with selectively grown multiple electrodes were developed to mimic the swimming locomotion of a fish. The developed method is based on combining electroplating with the electroless chemical reduction using the patterned mask. The advantages of this fabrication method are that the initial compositing between the polymer and platinum particles can be assured by the chemical reduction method, and the thickness of each electrode can be controlled easily and rapidly by electroplating. By using the fabricated actuator with a multiple degree of freedom, the oscillatory wave of the flexible membrane actuator was generated and a twisting motion was also realized to verify the possibility of mimicking the fish-like locomotion. The frequency response function was analyzed to investigate the natural frequency and the damping factor by a mechanical shaker and direct electrical excitation through the swept-sine method. Present results show that this novel method can be a promising technique to easily pattern each of multiple electrodes and to implement the biomimetic motion of the polymer actuators with good mechanical bending performance.

  • PDF