• Title/Summary/Keyword: Patients' information

Search Result 4,976, Processing Time 0.032 seconds

The Relationship between Expression of EGFR, MMP-9, and C-erbB-2 and Survival Time in Resected Non-Small Cell Lung Cancer (수술을 시행한 비소세포 폐암 환자에서 EGFR, MMP-9 및 C-erbB-2의 발현과 환자 생존율과의 관계)

  • Lee, Seung Heon;Jung, Jin Yong;Lee, Kyoung Ju;Lee, Seung Hyeun;Kim, Se Joong;Ha, Eun Sil;Kim, Jeong-Ha;Lee, Eun Joo;Hur, Gyu Young;Jung, Ki Hwan;Jung, Hye Cheol;Lee, Sung Yong;Lee, Sang Yeub;Kim, Je Hyeong;Shin, Chol;Shim, Jae Jeong;In, Kwang Ho;Kang, Kyung Ho;Yoo, Se Hwa;Kim, Chul Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.3
    • /
    • pp.286-297
    • /
    • 2005
  • Background : Non-small cell lung cancer (NSCLC) is a common cause of cancer-related death in North America and Korea, with an overall 5-year survival rate of between 4 and 14%. The TNM staging system is the best prognostic index for operable NSCLC . However, epidermal growth factor receptor (EGFR), matrix metalloproteinase-9(MMP-9), and C-erbB-2 have all been implicated in the pathogenesis of NSCLC and might provide prognostic information. Methods : Immunohistochemical staining of 81 specimens from a resected primary non-small cell lung cancer was evaluated in order to determine the role of the biological markers on NSCLC . Immunohistochemical staining for EGFR, MMP-9, and C-erbB-2 was performed on paraffin-embedded tissue sections to observe the expression pattern according to the pathologic type and surgical staging. The correlations between the expression of each biological marker and the survival time was determined. Results : When positive immunohistochemical staining was defined as the extent area>20%(more than Grade 2), the positive rates for EGFR, MMP-9, and C-erbB-2 staining were 71.6%, 44.3%, and 24.1% of the 81 patients, respectively. The positive rates of EGFR and MMP-9 stain for NSCLC according to the surgical stages I, II, and IIIa were 75.0% and 41.7%, 66.7% and 47.6%, and 76.9% and 46.2%, respectively. The median survival time of the EGFR(-) group, 71.8 months, was significantly longer than that of the EGFR(+) group, 33.5 months.(p=0.018, Kaplan-Meier Method, log-rank test).. The MMP-9(+) group had a shorter median survival time than the MMP-9(-) group, 35.0 and 65.3 months, respectively (p=0.2). The co-expression of EGFR and MMP-9 was associated with a worse prognosis with a median survival time of 26.9 months, when compared with the 77 months for both negative-expression groups (p=0.0023). There were no significant differences between the C-erbB-2(+) and C-erbB-2 (-) groups. Conclusion : In NSCLC, the expression of EGFR might be a prognostic factor, and the co-expression of EGFR and MMP-9 was found to be associated with a poor prognosis. However, C-erbB-2 expression had no prognostic significance.

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

Utility of Wide Beam Reconstruction in Whole Body Bone Scan (전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성)

  • Kim, Jung-Yul;Kang, Chung-Koo;Park, Min-Soo;Park, Hoon-Hee;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of $^{99m}Tc$-HDP administered but second group altered dosage of $^{99m}Tc$-HDP with 740 and 1,110 MBq (20 mCi and 30 mCi) in same scan speed. The acquired data was reconstructed using the typical clinical protocol in use and the WBR protocol. The patient's information was removed and a blind reading was done on each reconstruction method. For each reading, a questionnaire was completed in which the reader was asked to evaluate, on a scale of 1-5 point. Results: The result of planar WBR data improved resolution more than 10%. The Full-Width at Half-Maximum (FWHM) of WBR data improved about 16% (Standard: 8.45, WBR: 7.09). SPECT WBR data improved resolution more than about 50% and evaluate FWHM of WBR data (Standard: 3.52, WBR: 1.65). A clinical evaluation study, there was no statistically significant difference between the two method, which includes improvement of the bone to soft tissue ratio and the image resolution (first group p=0.07, second group p=0.458). Conclusion: The WBR method allows to shorten the acquisition time of bone scans while simultaneously providing improved image quality and to reduce the dosage of radiopharmaceuticals reducing radiation dose. Therefore, the WBR method can be applied to a wide range of clinical applications to provide clinical values as well as image quality.

  • PDF

A Refined Method for Quantification of Myocardial Blood Flow using N-13 Ammonia and Dynamic PET (N-13 암모니아와 양전자방출단층촬영 동적영상을 이용하여 심근혈류량을 정량화하는 새로운 방법 개발에 관한 연구)

  • Kim, Joon-Young;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Ju, Hee-Kyung;Kim, Yong-Jin;Kim, Byung-Tae;Choi, Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.73-82
    • /
    • 1997
  • Regional myocardial blood flow (rMBF) can be noninvasively quantified using N-13 ammonia and dynamic positron emission tomography (PET). The quantitative accuracy of the rMBF values, however, is affected by the distortion of myocardial PET images caused by finite PET image resolution and cardiac motion. Although different methods have been developed to correct the distortion typically classified as partial volume effect and spillover, the methods are too complex to employ in a routine clinical environment. We have developed a refined method incorporating a geometric model of the volume representation of a region-of-interest (ROI) into the two-compartment N-13 ammonia model. In the refined model, partial volume effect and spillover are conveniently corrected by an additional parameter in the mathematical model. To examine the accuracy of this approach, studies were performed in 9 coronary artery disease patients. Dynamic transaxial images (16 frames) were acquired with a GE $Advance^{TM}$ PET scanner simultaneous with intravenous injection of 20 mCi N-13 ammonia. rMBF was examined at rest and during pharmacologically (dipyridamole) induced coronary hyperemia. Three sectorial myocardium (septum, anterior wall and lateral wall) and blood pool time-activity curves were generated using dynamic images from manually drawn ROIs. The accuracy of rMBF values estimated by the refined method was examined by comparing to the values estimated using the conventional two-compartment model without partial volume effect correction rMBF values obtained by the refined method linearly correlated with rMBF values obtained by the conventional method (108 myocardial segments, correlation coefficient (r)=0.88). Additionally, underestimated rMBF values by the conventional method due to partial volume effect were corrected by theoretically predicted amount in the refined method (slope(m)=1.57). Spillover fraction estimated by the two methods agreed well (r=1.00, m=0.98). In conclusion, accurate rMBF values can be efficiently quantified by the refined method incorporating myocardium geometric information into the two-compartment model using N-13 ammonia and PET.

  • PDF

Internal Changes and Countermeasure for Performance Improvement by Separation of Prescribing and Dispensing Practice in Health Center (의약분업(醫藥分業) 실시(實施)에 따른 보건소(保健所)의 내부변화(內部變化)와 업무개선방안(業務改善方案))

  • Jeong, Myeong-Sun;Kam, Sin;Kim, Tae-Woong
    • Journal of agricultural medicine and community health
    • /
    • v.26 no.1
    • /
    • pp.19-35
    • /
    • 2001
  • This study was conducted to investigate the internal changes and the countermeasure for performance improvement by Separation of Prescribing and Dispensing Practice (SPDP) in Health Center. Data were collected from two sources: Performance report before and after SPDP of 25 Health Centers in Kyongsangbuk-do and 6 Health Centers in Daegu-City and self-administerd questionnaire survey of 221 officials at health center. The results of this study were summarized as follows: Twenty-four health centers(77.4%) of 31 health centers took convenience measures for medical treatment of citizens and convenience measures were getting map of pharmacy, improvement of health center interior, introduction of order communication system in order. After the SPDP in health centers, 19.4% of health centers increased doctors and 25.8% decreased pharmacists. 58.1% of health centers showed that number of medical treatments were decreased. 96.4%, 80.6% 80.6% 96.7% of health centers showed that number of prescriptions, total medical treatment expenses, amounts paid by the insureds and the expenses to purchase drugs, respectively, were decreased. More than fifty percent(54.2%) of health centers responded that the relative importance of health works increased compared to medical treatments after the SPDP, and number of patients decreased compared to those in before the SPDP. And there was a drastic reduction in number of prescriptions, total medical treatment expenses, amounts paid by insureds, the expenses to purchase drugs after the SPDP. Above fifty percent(57.6%) of officers at health center responded that the function of medical treatment should be reduced after the SPDP. Fields requested improvement in health centers were 'development of heath works contents'(62.4%), 'rearrangement of health center personnel'(51.6%), 'priority setting for health works'(48.4%), 'restructuring the organization'(36.2%), 'quality impro­vement for medical services'(32.1%), 'replaning the budgets'(23.1%) in order. And to better the image of health centers, health center officers replied that 'health information management'(60.7%), 'public relations for health center'(15.8%), 'kindness of health center officers'(15.3%) were necessary in order. Health center officers suggested that 'vaccination program', 'health promotion', 'maternal and children health', 'communicable disease management', 'community health planning' were relatively important works, in order, performed by health center after SPDP. In the future, medical services in health centers should be cut down with a momentum of the SPDP so that health centers might reestablish their functions and roles as public health organizations, but quality of medical services must be improved. Also health centers should pay attention to residents for improving health through 'vaccination program', 'health promotion', 'mother-children health', 'acute and chronic communicable disease management', 'community health planning', 'oral health', 'chronic degenerative disease management', etc. And there should be a differentiation of relative importance between health promotion services and medical treatment services by character of areas(metropolitan, city, county).

  • PDF

Genetic Counseling in Korean Health Care System (한국 의료제도와 유전상담 서비스의 구축)

  • Kim, Hyon-J.
    • Journal of Genetic Medicine
    • /
    • v.8 no.2
    • /
    • pp.89-99
    • /
    • 2011
  • Over the years Korean health care system has improved in delivery of quality care to the general population for many areas of the health problems. The system is now being recognized in the world as the most cost effective one. It is covered by the uniform national health insurance policy for which most people in Korea are mandatory policy holders. Genetic counseling service, however, which is well recognized as an integral part of clinical genetics service deals with diagnosis and management of genetic condition as well as genetic information presentation and family support, is yet to be delivered in comprehensive way for the patients and families in need. Two major obstacles in providing genetic counseling service in korean health care system are identified; One is the lack of recognition for the need for genetic counseling service as necessary service by the national health insurance. Genetic counseling consumes a significant time in delivery and the current very low-fee schedule for physician service makes it very difficult to provide meaningful service. Second is the critical shortage of qualified professionals in the field of medical genetics and genetic counseling who can provide the service of genetic counseling in clinical setting. However, recognition and understanding of the fact that the scope and role of genetic counseling is expanding in post genomic era of personalized medicine for delivery of quality health care, will lead to the efforts to overcome obstacles in providing genetic counseling service in korean health care system. Only concerted efforts from health care policy makers of government on clinical genetics service and genetic counseling for establishing adequate reimbursement coverage and professional communities for developing educational program and certification process for professional genetic counselors, are necessary for the delivery of much needed clinical genetic counseling service in Korea.