• 제목/요약/키워드: Patient type

검색결과 2,995건 처리시간 0.041초

I, II기 악성 림프종 환자의 방사선 치료 성적 (Result of Radiation Therapy for Stage I, II Non-Hodgkin's Lymphoma)

  • 이규찬;김철용;최명선
    • Radiation Oncology Journal
    • /
    • 제11권1호
    • /
    • pp.159-166
    • /
    • 1993
  • A retrospective analysis was done for 69 patients with Stage I and II non-Hodgkin's lymphoma who were treated from May 1981 to December 1990, in the Department of Radiadtion Oncology, Korea University Hospital. We used Ann Arbor Staging system and Working Formulation for histological classification. Forty-three patients (43/69, $62.3{\%}$) were Stage I and 26 patients (26/69, $37.7{\%}$) were Stage II, and B symptom was found in $10.1{\%}$ (7/69). Nodal lymphoma was $21.7{\%}$ (15/69); 14 patients with supradiaphragmatic disease and 1 patient with infradiaphragmatic disease. Extranodal lymphoma was $78.3{\%}$ (54/69): $64.8{\%}$ (35/54) for head and neck, $25.9{\%}$ (14/54) for gastrointestinal tract. Histologically, low grade consists of $8.7{\%}$ (6/69), intermediate grade $84.2{\%}$ (56/69), high grade $10.1{\%}$ (7/69), and diffuse large cell type was the most frequent form with 36 patients (36/69, $52.2{\%}$). Eighteen patients ($26.1{\%}$) were treated with radiation therapy alone,20 patients ($29.0{\%}$) with radiation therapy combined with chemotherapy, 15 patients ($21.7{\%}$) with radiation therapy combined with surgery and chemotherapy, Median survival duration was 28 months, and the range of survival time was from 1 month to 134 months. Overall five-year survival rate for Stage I and II disease was $54.2{\%}$, with $64.5{\%}$ for Stage I and $37.1{\%}$ for Stage II. For nodal lymphoma,5-year survival rate was $45.9{\%}$, and $56.5{\%}$ for extranodal lymphoma; $60.6{\%}$ for head and neck, $52.9{\%}$ for GI tract primary disease. Local control rate for all patients was $88.4{\%}$ (61/69), with $80{\%}$ (12/15) for nodal lymphoma and $90.7{\%}$ (49/54) for extranodal lymphoma. The total failure rate was $34.8{\%}$ (24/69). Five of 24 ($20.8{\%}$) patients who were failed developed local failure only, $12.5{\%}$ (3/24) local failure with distant failure, and distant failure only were found in $66.7{\%}$ (16/24). Between nodal lymphoma and extranodal lymphoma, there was no significant survival difference, but extranodal lymphoma showed higher incidence.

  • PDF

소아에서 관찰된 IgG-associated mesangial glomerulonephritis 2례 (Two Cases of IgG-associated Mesangial Glomerulonephritis in Children)

  • 이상후;김병길;송지선
    • Childhood Kidney Diseases
    • /
    • 제12권1호
    • /
    • pp.93-98
    • /
    • 2008
  • IgG 신병증(IgG-associated mesangial glomerulonephritis)은 전세계적으로 드물게 보고되고 있는 새로운 원발성 사구체 질환으로 1993년 Sato 등에 의해 처음으로 보고되었고 이후 1994년 Yoshikawa 등에 의해 소아에서의 10례가 보고되었다. 주로 단백뇨를 주소로 하며 현미경적 혈뇨를 동반하기도 한다. 이 질환은 조직 면역 형광 검사상 사구체 간질에 IgG의 침착을 보이는 사구체 신염이다. 이 질환은 초기에는 양성 경과를 취하는 것으로 알려졌으나 2002년 Fakhouri 등은 대부분은 양성 경과를 보이지만 일부는 말기 신부전증으로 진행함을 관찰할 수 있었으며 1례에서는 신장이식 후 이식신에서 IgG 신병증이 재발된 예도 보고 하였다. 본 증례에서는 한명은 신증후군이 동반되었고 한명은 무증상 현미경적 혈뇨만을 보였다. 이들 모두 면역 형광 현미경 소견상 사구체 간질에 IgG 침착이 주로 보였고 IgM, 보체의 침착도 보였다. 또한 전자현미경 소견상 사구체간질에 고밀도 전자 침착이 보였다. 신생검에서 면역 현미경 소견과 전자 현미경 소견으로 진단된 IgG 신병증 소아환자 2례를 경험하고 국내에서는 아직 보고된 예가 없기에 문헌 고찰과 함께 증례를 보고하는 바이다.

  • PDF

MRI 검사 시 체온상승 효과: 1.5 T vs 3.0 T (Effective of Body Temperature Increasing during Brain MRI scan)

  • 김명성;이종웅;정재은
    • 한국방사선학회논문지
    • /
    • 제11권1호
    • /
    • pp.49-54
    • /
    • 2017
  • MRI장비에서 자장의 세기가 증가 하게 되면 사용하는 RF(Radiofrequency) pulse 또한 증가 하게 되고 이는 MRI 장비 안에 놓인 인체의 체온 상승을 증가 시키게 하는 역할을 하게 된다. 이에 국소부위에서의 열 발생을 알아보고자 젤라틴과 pork sample 이용하여 측정하였다. 본 연구는 2014년 12월 21일부터 2015년 8월 14일까지 153명의 환자를 대상으로 실시하였다. 3대의 MRI(1.5T- 1대, 3.0T- 2대)장비를 사용하여 뇌 또는 간 부위에서 일상적으로 쓰이는 sequence 프로토콜을 동일하게 적용하여 검사하였다. 검사 전 후 체온 측정은 적외선 타입의 귀 체온계(Braun社)를 사용하였으며 대상자의 심리적 상태는 직접 설문을 통하여 파악했다. 임상 환자를 대상으로 한 체온 상승 결과를 보면 3.0T가 1.5T에서보다 평균 $0.15^{\circ}C$정도 높았고(p<0.012) 3.0T내 에서도 Philips제조회사에서 보다 GE社 MRI장비에서 $0.14^{\circ}C$정도 더 높았다. 심인성 상태에 따른 결과를 살펴보면 MRI검사 진행 중 나는 소리에 대한 민감성 정도와 체온상승과의 관계는 무관하였고, 폐쇄성에 대한 응답이 긴장감으로 느꼈다고 대답하는 사람일수록 체온이 더 상승하는 경향을 보였다. 자장의 세기가 높은 MRI장비일수록 RF 반응물질(물, 금속물질)에 의한 화상이나 체온상승으로 인한 위험한 상황발생(체온조절 장해 환자의 경우 고온 손상, 과다 땀 발생으로 인한 탈진)이 나타나지 않도록 환자의 상태를 좀 더 예의 주시하며 MRI검사를 진행할 필요가 있겠다. 높은 자기장을 기반으로 한 MRI장비는 인체에 흡수되는 전자파 흡수율인 SAR를 비례적으로 증가시키므로 앞으로는 RF 코일 성능을 향상하거나 영상의 질을 향상시키기 위한 이미지 프로그램을 개발하는 등 자기장 이외의 방법을 강구하는 것이 필요하다.

Ebstein 기형의 수술 -2례 보고- (Surgical Repair for Ebstein's Anomaly)

  • naf
    • Journal of Chest Surgery
    • /
    • 제12권3호
    • /
    • pp.289-296
    • /
    • 1979
  • For years, physicians and anatomists have been interested in the heart that has one functioning ventricle. Various terms have been suggested for this entity including single ventricle, common ventricle, double-inlet left ventricle, cor biatriatum triloculare, and primitive ventricle. In this report, the term "single ventricle" is utilized as suggested by Van Praagh, and is defined as that congenital cardiac anomaly in which a common or separate atrioventricular valves open into a ventricular chamber from which both great arterial trunks emerge. An outlet chamber, or infundibulum, may or may not be present and give rise to the origin of either of the great arteries. This definition excludes the entity of mitral and tricuspid atresia. An 11 year old cyanotic boy was admitted chief complaints of exertional dyspnea and frequent upper respiratory infection since 2 weeks after birth. He was diagnosed as inoperable cyanotic congenital heart disease, and remained without any corrective treatment up to his age of 11 year when he suffered from aggravation of symptoms and signs of congestive heart failure for 2 months before this admission. On 22nd of May 1979, he was admitted for total corrective operation under the impression of tricuspid atresia suggested by a pediatrician. Physical check revealed deep cyanosis with finger and toe clubbing, and grade V systolic ejection murmur with single second heart sound was audible at the left 3rd intercostal space. Development was moderate in height [135 cm] and weight[28Kg]. Routine lab findings were normal except increased hemoglobin [21.1gm%], hematocrit [64 %], and left axis deviation with left ventricular hypertrophy on EKG. Cardiac catheterization and angiography revealed 1-transposition of aorta, pulmonic valvular stenosis, double inlet of a single ventricle with d-loop, and normal atriovisceral relationship [Type III C solitus according to the classification of Van Praagh]. At operation, longitudinal incision at the outflow tract of right ventricle in between the right coronary artery and its branch [LAD from RCA] revealed high far anterior aortic valve which had fibrous continuity with mitral annulus, and pulmonic valve was stenotic up to 4 mm in diameter positioned posterolaterally to the aorta. Ventricular septum was totally defective, and one markedly hypertrophied moderator band originated from crista supraventricularis was connected down to the imaginary septum of the ventricular cavity as a pseudoseptum of the ventricle. Size of the defect was 3X3 cm2 in total. Patch closure of the defect with a Teflon felt of 3.5 x 4 cm2 was done with interrupted multiple sutures after cut off of the moderator band, which was resutured to the artificial septum after reconstruction of the ventricular septum. Pulmonic valvotomy was done from 4 mm to 11 mm in diameter thru another pulmonary arteriotomy incision, and right ventriculotomy wound was closed reconstructing the right ventricular outflow tract with pericardial autograft of 3 x 4 cm2. Atrial septal defect of 2 cm in diameter was closed with 3-0 Erdeck suture, and atrial wall was sutured also when rectal temperature reached from 24`C to 35.5`C. Complete A-V block was managed with temporary external pacemaker with a pacing rate of 110/min. thru myocardial wire, and arterial blood pressure of 80/50 mmHg was maintained with Isuprel or Dopamine dripping under the CVP of 25-cm saline. Consciousness was recovered one hour after the operation when his blood pressure reached 100 /70 mmHg, but vital signs were not stable, and bleeding from the pericardial drainage and complete anuria were persisted until his heart could not capture the pacemaker impulse, and patient died of low output syndrome 320 min after the operation.

  • PDF

늑간 신경 냉동요법에 의한 개흉술후 흉부 동통 관리 (Cryoanalgesia for the Post-thoracotomy Pain)

  • 김욱진;최영호;김형묵
    • Journal of Chest Surgery
    • /
    • 제24권1호
    • /
    • pp.54-63
    • /
    • 1991
  • Post-thoracotomy pain is so severe that lead to postoperative complications, such as sputum retention, segmental or lobar atelectasis, pneumonia, hypoxia, respiratory failure due to the patient`s inability to cough, deep breathing and movement. Many authors have been trying to reduce the post-thoracotomy pain, but there is no method of complete satisfaction. In 1974, Nelson and associates introduced the intercostal nerve block using the cryoprobe. The application of cold directly to the nerves causes localized destruction of the axons while preserving the endoneurium and connective tissue, thereby introducing a temporary pain block and able to complete regeneration of intercostal nerves. One hundred and two patients, who undergoing axillary or posterolateral thoracotomy at the Department of Thoracic and Cardiovascular Surgery in Korea University Medical Center between April 1990 and August 1990, were evaluated the effects of cryoanalgesia for the post-thoracotomy pain reduction. The patients were divided into two groups: Group A, control, the patients without the cryoanalgesia[No.=50], Group B, trial, the patients with cryoanalgesia[No.=52]. Before the thorax closed, in the group A, local anesthetics, 2% lidocaine 3cc, were injected to the intercostal nerves[one level with the thoracotomy, one cranial and caudal intercostal level and level of drainage tube insertion]. In the group B, cryoprobe was directly applied for 1 minute at the same level. Postoperative analgesic effects were evaluated by the scoring system which made arbitrary by author: The pain score 0 to 4, The limitation of motion score 0 to 3, The analgesics consumption score 0 to 3, The total score, the sum of above score, 0 to 10. For the evaluation of immediate analgesic effects, the score were evaluated at the operative day, the first postoperative day, the second postoperative day, and the seventh postoperative day. The effects of incision type, and rib cut to the post-thoracotomy pain were also evaluated. The results were as follows; 1. The intercostal block with cryoanalgesia reduced the immediate postoperative pain significantly compare with control group. 2. The intercostal block with cryoanalgesia improved the motion of the operation side significantly compare with control group. 3. The intercostal block with cryoanalgesia reduced the analgesics requirements at the immediate postoperative periods significantly. 4. The intercostal block with cryoanalgesia lowered the total score significantly compare with control group. 5. The intercostal block with cryoanalgesia were more effective to the mid-axillary incision than to the posterolateral incision 6. The intercostal block with cryoanalgesia were more effective to the patients without rib cut than to the patients with rib cut. 7. No specific complication need to be treated were not occurred during follow-up.

  • PDF

Clinical Results of Ascending Aorta and Aortic Arch Replacement under Moderate Hypothermia with Right Brachial and Femoral Artery Perfusion

  • Kim, Jong-Woo;Choi, Jun-Young;Rhie, Sang-Ho;Lee, Chung-Eun;Sim, Hee-Je;Park, Hyun-Oh
    • Journal of Chest Surgery
    • /
    • 제44권3호
    • /
    • pp.215-219
    • /
    • 2011
  • Background: Selective antegrade perfusion via axillary artery cannulation along with circulatory arrest under deep hypothermia has became a recent trend for performing surgery on the ascending aorta and aortic arch and when direct aortic cannulation is not feasible. The authors of this study tried using moderate hypothermia with right brachial and femoral artery perfusion to complement the pitfalls of single axillary artery cannulation and deep hypothermia. Materials and Methods: A retrospective analysis was performed on 36 patients who received ascending aorta or aortic arch replacement between July 2005 and May 2010. The adverse outcomes included operative mortality, permanent neurologic dysfunction and temporary neurologic dysfunction. Results: Of these 36 patients, 32 (88%) were treated as emergencies. The mean age of the patients was 61.9 years (ranging from 29 to 79 years) and there were 19 males and 17 females. The principal diagnoses for the operation were acute type A aortic dissection (31, 86%) and aneurysmal disease without aortic dissection (5, 14%). The performed operations were ascending aorta replacement (9, 25%), ascending aorta and hemiarch replacement (13, 36%), ascending aorta and total arch replacement (13, 36%) and total arch replacement only (1, 3%). The mean cardiopulmonary bypass time was $209.4{\pm}85.1$ minutes, and the circulatory arrest with selective antegrade perfusion time was $36.1{\pm}24.2$ minutes. The lowest core temperature was $24{\pm}2.1^{\circ}C$. There were five deaths within 30 post-op days (mortality: 13.8%). Two patients (5.5%) had minor neurologic dysfunction and six patients, including three patients who had preoperative cerebral infarction or unconsciousness, had major neurologic dysfunction (16.6%). Conclusion: When direct aortic cannulation is not feasible for ascending aorta and aortic arch replacement, the right brachial and femoral artery can be used as arterial perfusion routes with the patient under moderate hypothermia. This technique resulted in acceptable outcomes.

외상성 횡격막 파열에서 예후에 영향을 미치는 인자 (The Prognostic Factors of Traumatic Diaphragmatic Rupture)

  • 조석기;이응배;석양기
    • Journal of Chest Surgery
    • /
    • 제43권1호
    • /
    • pp.47-52
    • /
    • 2010
  • 배경: 외상성 횡격막 파열은 흔하지는 않지만 응급을 요하는 손상이다. 이 연구에서는 외상성 횡격막 파열의 원인, 동반된 손상의 종류, 진단 방법, 수술 후 예후 인자 등을 알아 보고자 하였다. 대상 및 방법: 2001년 1월부터 2008년 12월까지 본원 응급실을 통해서 내원한 외상 환자들 중에서 수술을 통해서 외상성 횡격막 파열로 진단된 37명의 환자를 대상으로 하였다. 외상의 종류, 동반된 손상, 술 전 활력 징후, Injury Severity Score (ISS), 진단 방법 및 수술까지 걸린 시간, 수술 시 접근 방법, 파열부위 및 파열 정도, 파열된 횡격막을 통한 장기의 이탈 정도 등이 수술 후 사망률에 미치는 영향을 분석하였다. 결과: 둔상에 의한 경우가 30명(81.1%), 관통상에 의한 경우가 7명(18.9%)이었다. 34명 (91.9%)에서 횡격막 파열 이외에 동반된 손상이 있었으며, ISS는 평균 20.8이었다. 술 후 합병증은 총 11명(29.7%)에서 발생하였으며, 술 후 사망은 6명(16.2%)에서 발생하였다. 술 후 사망에 영향을 미치는 인자로는 술 전 기관 삽입, 술 전 저혈압, 20점 이상의 ISS 등이 있었다. 결론: 외상성 횡격막 파열은 다발성 손상의 한 부분으로 발생하는 손상이며, 수술 후 예후는 횡격막 손상 자체보다는 동반된 손상 정도에 따라 결정되었다.

새로운 유전자 돌연변이로 확진된 Ornithine Transcarbamylase (OTC) 결핍증 1례 (The Ornithine Transcarbamylase (OTC) Deficiency Identified by a Novel Mutation)

  • 송아리;이기욱;양아람;김진섭;박형두;조성윤;진동규
    • 대한유전성대사질환학회지
    • /
    • 제16권3호
    • /
    • pp.148-154
    • /
    • 2016
  • 요소 회로 대사 이상은 요소 합성에 관련된 효소의 결핍으로 인해 발생하는 질환으로, ornithine과 carbamylphosphate로부터 citrulline을 생성하는 과정에 관여하는 효소인 OTC 결핍증이 가장 흔하다. OTC 결핍증은 ammonia, glutamate, glutamine, alanine 등의 축적되면서 고암모니아 혈증 및 고글루타민 혈증으로 인한 신경학적 증상이 나타나게 되며, 근긴장 저하, 호흡 부전, 경련, 기면, 혼수로 진행하여 사망에 이르게 된다. 저자들은 생후 4일 경부터 구토와 함께 의식의 저하를 보인 환자에서 직열 질량 분석법을 통해 OTC 결핍증을 진단하였고, 증상 발생 31시간 만인 생후 118시간 째에 지속적 정정맥 혈액여과(continuous venovenous hemofiltration, CVVH)을 적용하여 고암모니아 혈증을 치료하였다. 또한 직접염기서열분석법을 통해 780번과 781번 염기 사이에 CAGGCAGTGT가 삽입되는 변이(c.780_781insCAGGCAGTGT (p.Ile261Glnfs*35))를 발견하였다. 환자는 4일 간의 CVVH 이후 혈중 암모니아 농도와 의식이 호전되어 생후 53일 째 퇴원하였으나, 생후 12개월 경 좌측 대퇴골의 골절과 골수염이 발생하였고, 이후 패혈증 쇼크, 고혈당, 다발성 장기부전으로 사망하였다. 이에 저자들은 OTC 결핍증 환자에서 CVVH 치료 및 패혈증과 당뇨를 경험하였고, 유전자 검사에서 이전에 보고된 바 없는 새로운 변이를 확인하였기에 증례를 보고하는 바이다.

  • PDF

안면부에 잔류된 다양한 이물질을 측정한 CT 계수 (CT Number Measurement of Residual Foreign Bodies in Face)

  • 위서영;최환준;김미선;최창용
    • Archives of Plastic Surgery
    • /
    • 제35권4호
    • /
    • pp.423-430
    • /
    • 2008
  • Purpose: Computed tomography theoretically should improve detection of foreign bodies and provide more information of adjacent soft tissues. And the CT scanner and PACS program proved to be an excellent instrument for detection and localization of most facial foreign bodies above certain minimum levels of detectability. The severity of injury in penetrating trauma to the face, it is often underestimated by physical examination. Diagnosis of a retained foreign object is always critical. Methods: From March, 2005 to February 2008 a study was done with 200 patients who had facial trauma. Axial and coronal CT images were obtained with a General Electric(Milwaukee, Wis) 9800 CT scanner at 130 kV, 90 mA, with a 2-mm section thickness and a $512{\times}512$ matrix. Results: Axial and coronal CT images at various window widths should be used as the first imaging modality to detect facial foreign bodies. The attenuation coefficients for the metallic and nonmetallic foreign bodies ranged from -437 to +3071 HU. As a general rule, metallic foreign bodies produced more Hounsfield artifacts than nonmetallic foreign bodies, thus providing a clue to their composition. All of the metallic foreign bodies were represented by a single peak and had a maximum attenuation coefficient of +3071 HU. Of the nonmetallic foreign bodies, glass had an attenuation coefficient that ranged from +105 to +2039, while plastic had a much lower coefficient that ranged from -62 to -35. wood had the lowest range of attenuation coefficients: -491 to -437. Conclusion: The PACS program allows one to distinguish metallic from nonmetallic foreign bodies and to individually identify the specific composition of many nonmetallic foreign bodies. This program does not, however, allow identification of the specific composition of a metallic foreign body. We recommend this type of software program for CT scanning of any patient with an injury to the face in which a foreign body is suspected.

Salvage of Infected Breast Implants

  • Song, Joon Ho;Kim, Young Seok;Jung, Bok Ki;Lee, Dong Won;Song, Seung Yong;Roh, Tai Suk;Lew, Dae Hyun
    • Archives of Plastic Surgery
    • /
    • 제44권6호
    • /
    • pp.516-522
    • /
    • 2017
  • Background Implant-based breast reconstruction is being performed more frequently, and implants are associated with an increased risk of infection. We reviewed the clinical features of cases of implant infection and investigated the risk factors for breast device salvage failure. Methods We retrospectively analyzed 771 patients who underwent implant-based breast reconstruction between January 2010 and December 2016. Age, body mass index, chemotherapy history, radiation exposure, and smoking history were assessed as potential risk factors for postoperative infection. We also evaluated the presence and onset of infection symptoms, wound culture pathogens, and other complications, including seroma, hematoma, and mastectomy skin necrosis. Additionally, we examined the mastectomy type, the use of acellular dermal matrix, the presence of an underlying disease such as hypertension or diabetes, and axillary node dissection. Results The total infection rate was 4.99% (58 of 1,163 cases) and the total salvage rate was 58.6% (34 of 58). The postoperative duration to closed suction drain removal was significantly different between the cellulitis and implant removal groups. Staphylococcus aureus infection was most frequently found, with methicillin resistance in 37.5% of the cases of explantation. Explantation after infection was performed more often in patients who had undergone 2-stage expander/implant reconstruction than in those who had undergone direct-to-implant reconstruction. Conclusions Preventing infection is essential in implant-based breast reconstruction. The high salvage rate argues against early implant removal. However, when infection is due to methicillin-resistant S. aureus and the patient's clinical symptoms do not improve, surgeons should consider implant removal.