• Title/Summary/Keyword: Passive scattering

Search Result 36, Processing Time 0.02 seconds

A Parasitic Elements Extraction of MIM Capacitor Using Short-Open Calibration Method (단락 개방 Calibration 방법을 이용한 MIM 커패시터의 기생 소자 값 추출)

  • Kim, Yu-Seon;Nam, Hun;Lim, Yeong-Seog
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.8
    • /
    • pp.114-120
    • /
    • 2008
  • In this paper, we extract the parasitic elements of the metal-insulate-metal(MIM) capacitor using short-open calibration (SOC). The scattering matrixes of short, open, and MIM structures in strip lines are measured by full electro-magnetic (EM) simulator and vector network analyser. The full EM simulations are performed by finite element method (FEM) that was fitted three dimensional structure analysis. The electro-magnetic effects of MIM capacitor laminated in the multi-layered structures are proposed the II equivalent circuit with lumped elements, and the relations between the measured scattering parameters of the MIM structures and lumped elements in the circuits are shown by performing 2 port network analysis. The extracted lumped elements using the proposed SOC method are independent to frequencies.

A Study on the Tendency of Fugitive Dust for Environmental Maintenance at the Aggregate Unloading Site of Ready-mixed Concrete Plants (레미콘 플랜트의 골재하차장 환경 유지관리를 위한 비산먼지 발생 경향에 관한 연구)

  • Cho, Hyun-Woo;Shin, Hong-Chul;Chung, Yoon-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.103-111
    • /
    • 2022
  • Fine dust can cause serious problems to human health, and fugitive dust generated at construction sites is one of the main sources of fine dust in Korea. However, monitoring of the amount of fugitive dust generated at the ready-mixed concrete plant site is not performed, and only passive monitoring methods are partially applied in the field. Since it is impossible to control fugitive dust after it is exposed to the air, it is very important to suppress the occurrence or to remove it immediately at the stage of occurrence. Therefore, after identifying the characteristics through real-time monitoring in the fugitive dust generation stage, systematic management is required for suppressing or removing scattering dust in the field. In this study, the scattering dust generation characteristics were analyzed by measuring the particle mass concentration(PMC) of Fugitive dust generated at the aggregate unloading site of the ready-mixed concrete plant in real-time.

Environmental Maintenance Technology for Concrete Manufacturing Industry by Using an Automatic Fugitive Dust Reduction System (비산먼지 자동 저감시스템을 이용한 콘크리트 제조업 환경 유지관리 기술)

  • Hyun-Woo Cho;Yoon-Seok Chung;Deuk-Hyun Ryu;Yun-Yong Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.4
    • /
    • pp.70-77
    • /
    • 2023
  • Fine dust is a cause of serious ecological problems, and fugitive dust generated from construction sites is a major source of fine dust in Korea. However, at construction sites, including concrete manufacturing industry sites, measurements are rarely made at the fugitive dust generation stage, and passive removal methods are the majority. Therefore, in this study, a fugitive dust measurement method suitable for managing fugitive dust generated during aggregate unloading in the concrete manufacturing industry sites was selected. In addition, the purpose was to analyze the amount of fugitive dust reduction according to the operation of the reduction system by applying the automatic fugitive dust reduction system to the aggregate unloading site. As a result, the reliability of the light scattering method was secured through the comparative measurement of the beta-ray absorption method and the light scattering method, and the light scattering method correction coefficient was calculated and applied to the measured value of the fugitive dust particle mass concentration at the concrete manufacturing industry sites. In addition, the fugitive dust reduction rate according to the operation of the automatic fugitive dust reduction system was derived.

RF Detecting Circuit Analysis by Using BLT Equation (BLT 방정식을 이용하 RF 검파 회로 해석)

  • Hwang, Se-Hoon;Park, Yoon-Mi;Jung, Hyun-Kyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1643-1647
    • /
    • 2007
  • Recently, there is a need for research concerning the technologies and precaution methods against electronic bomb assaults. There lays perplex constitution and much coupling phenomenon in this type of system, and thus requires much time and memory in order to translate the system with the existing translation methods. Applying the EMT (Electromagnetic Topology) would prove much more efficient. In this paper, EMT has been applied to the circuit-like micro system, previously employed in micro systems. Also, each section has been interpreted using the BLT (Baum, Liu, Tesche) equation using the EMT, then reconstructed, consequentially interpreting an entire system. In this paper, a simple circuit containing active and passive elements based on a CPW has been interpreted employing the BLT equation, and has been proven by experiment using the circuit simulation, a simulation officially recognized for its accuracy in interpreting small structures. The interpretation results have been presented by an S-parameter, and by comparing the interpretation results attained through the BLT equation and that from common simulation to that from experimentation, that the BLT equation turned out to be the most reliable interpretation method could be found.

The Difference in Severity and Frequency of Classroom Discipline Problems Between Male and Female Students in Middle School Classrooms (중학교 남·여 학급간 학급 훈육문제의 심각성과 빈도의 차이)

  • KIM, Dal-Hyo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.17 no.1
    • /
    • pp.35-47
    • /
    • 2005
  • The purpose of this study is to investigate various kinds of discipline problems in middle school classrooms, and the differences in severity and frequency of the classroom discipline problems between male and female students' classrooms in middle schools. This study shows that the discipline problems in the middle school classrooms include using a cellular phone, chattering, sleeping, chewing gum, reading comic books, asking useless questions, challenging a teacher, fighting, calling names, skipping class, throwing trash in the classroom, breaking classroom equipment, creating disorder, losing materials, playing with a ball in the classroom, gambling, and so on. Generally, male students recognized the severity of the classroom discipline problems more than the female students. However, it is shown that the frequency of discipline problems in male students' classrooms is higher than that in female students' classrooms. From the results of this study, male students have more active discipline problems (playing with a ball in the classroom, throwing trash in the classroom, coming to class late, gambling, cutting in line, and so on). On the other hand, female students have more passive discipline problems (making a noise by using a cellular phone, asking useless questions, sending messages to a classmate, studying other subjects, scattering, and so on).

High Frequency Simulations for the Meander Type Inductors on the MgO and Al2O3 Substrates (산화마그네슘 기판과 산화알루미늄 기판을 이용한 Meander 형태 인덕터의 고주파 시뮬레이션)

  • Ham, Yong-Su;Kim, Sung-Hun;Kang, Ey-Goo;Koh, Jung-Hyuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.8
    • /
    • pp.641-644
    • /
    • 2009
  • We have studied on the microwave characteristics for the meander type inductors on the MgO substrates and $Al_2O_3$ substrates by employing 3-D high frequency simulation, respectively. Proper designs of meander type inductors were proposed and confirmed through the high frequency simulations, 5, 7, 9, 11, and 13 turns meander type inductors have been choose to analyze the electrical properties for the microwave passive component applications. The Al top electrodes have 282 nm length, 45 nm width, 100 nm thickness and 15 nm gap. The simulations were carried out from 50 MHz to 30 GHz, Frequency dependent inductances and quality factor were calculated by employing the equivalent circuit model of meander type inductors. The self resonances frequency of meander type inductor were shifted from high frequency to low frequency range as the number of the turn of inductors was increased. From the microwave simulations, the inductances and quality factors of meander type inductors were extracted through the scattering parameter.

Role of Radio Frequency and Microwaves in Magnetic Fusion Plasma Research

  • Park, Hyeon K.
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.4
    • /
    • pp.169-177
    • /
    • 2017
  • The role of electromagnetic (EM) waves in magnetic fusion plasma-ranging from radio frequency (RF) to microwaves-has been extremely important, and understanding of EM wave propagation and related technology in this field has significantly advanced magnetic fusion plasma research. Auxiliary heating and current drive systems, aided by various forms of high-power RF and microwave sources, have contributed to achieving the required steady-state operation of plasmas with high temperatures (i.e., up to approximately 10 keV; 1 eV=10000 K) that are suitable for future fusion reactors. Here, various resonance values and cut-off characteristics of wave propagation in plasmas with a nonuniform magnetic field are used to optimize the efficiency of heating and current drive systems. In diagnostic applications, passive emissions and active sources in this frequency range are used to measure plasma parameters and dynamics; in particular, measurements of electron cyclotron emissions (ECEs) provide profile information regarding electron temperature. Recent developments in state-of-the-art 2D microwave imaging systems that measure fluctuations in electron temperature and density are largely based on ECE. The scattering process, phase delays, reflection/diffraction, and the polarization of actively launched EM waves provide us with the physics of magnetohydrodynamic instabilities and transport physics.

A Construction Scheme of Next Generation Wire Communication System by using Long-reach WDM-PON (장거리 전송 파장분할 다중방식 수동형 광가입자망을 이용한 차세대 국방 유선통신체계 구축방안)

  • Kim, Min-Hwan;Lee, Sang-Mook;Lee, Chang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.90-99
    • /
    • 2007
  • We demonstrate an 80km-reach 64-channel DWDM-PON based on wavelength-locked F-P LDs by changing the position of the C-band BLS for upstream channels from the CO to the RN. It mitigates the necessity of the high power C-band BLS and its handling problems. It also reduces back scattering induced penalty. We obtained less than $10^{-6}$ PLRs in all 128channels through 80km SMF. We also demonstrate a 240km-reach DWDM-PON based on wavelength-locked F-P LDs by adding a bidirectional erbium-doped fiber amplifier(EDFA). We show packet-loss-free transmission in all 128channels at 125 Mb/s per channel over 240km SMF We report the detuning effect of arrayed waveguide gratings(AWGs) and crosstalk effect in the implemented system. We Propose an architecture of a next generation defense wire communication system with the demonstrated long-reach DWDM-PON.

Polymeric Micelle Using Poly((R)-3-hydroxybutyric acid)/Poly(ethylene glycol) Amphiphilic Block Copolymer for Drug Delivery System (Poly((R)-3-hydroxybutyric acid)/Poly(ethylene glycol) 양친성 블록 공중합체를 이용한 약물전달체용 고분자 미셀)

  • Jeong, Kwan-Ho;Kim, Young-Jin
    • Polymer(Korea)
    • /
    • v.30 no.6
    • /
    • pp.512-518
    • /
    • 2006
  • A biodegradable polymer poly((R) -3-hydroxybutyric acid) (PHB) was conjugated with a hydrophilic polymer poly(ethylene glycol) (PEG) by the ttansesterification reaction to form the amphiphilic block copolymer. PHB with low molecular weight ($3000{\sim}30000$) was appropriated for the drug delivery materials. High molecular weight PHB was hydrolyzed by an acid-catalyst to produce the low molecular weight one. Amphiphilic block copolymer was formed the self-assembled polymeric micelle system in the aqueous solution that the hydrophillic PEG was wraped the hydrophobic PHB. Generally, polymeric micelle forms the small particle between $10{\sim}200nm$. These polymeric micelle systems have been widely used for the drug delivery systems because they were biodegradable, biocompatible, non-toxic and patient compliant. The hydroxyl group of PEG was substituted with carboxyl group which has the reactivity to the ester group of PHB. Amphiphilic block copolymer was conjugated between PHB, and modified PEG at $176^{\circ}C$ which was higher than the melting point of PHB. Transesterification reaction was verified with DSC, FTIR, $^1H-NMR$. In the aqueous solution, critical micelle concentration (CMC) of the mPEG-co-PHB copolymer measured by the fluororescence scanning spectrometer was $5{\times}10^{-5}g/L$. The shape and size of the nanoparticle was taken by dynamic light scattering and atomic force microscopy. The size of the nanoparticle was about 130 nm and the shape was spherical. Our polymeric micelle system can be used as the passive targeting drug delivery system.

Therapeutic Proton Beam Range Measurement with EBT3 Film and Comparison with Tool for Particle Simulation

  • Lee, Nuri;Kim, Chankyu;Song, Mi Hee;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.112-119
    • /
    • 2019
  • Purpose: The advantages of ocular proton therapy are that it spares the optic nerve and delivers the minimal dose to normal surrounding tissues. In this study, it developed a solid eye phantom that enabled us to perform quality assurance (QA) to verify the dose and beam range for passive single scattering proton therapy using a single phantom. For this purpose, a new solid eye phantom with a polymethyl-methacrylate (PMMA) wedge was developed using film dosimetry and an ionization chamber. Methods: The typical beam shape used for eye treatment is approximately 3 cm in diameter and the beam range is below 5 cm. Since proton therapy has a problem with beam range uncertainty due to differences in the stopping power of normal tissue, bone, air, etc, the beam range should be confirmed before treatment. A film can be placed on the slope of the phantom to evaluate the Spread-out Bragg Peak based on the water equivalent thickness value of PMMA on the film. In addition, an ionization chamber (Pin-point, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose. Results: The eye phantom was used for independent patient-specific QA. The differences in the output and beam range between the measurement and the planned treatment were less than 1.5% and 0.1 cm, respectively. Conclusions: An eye phantom was developed and the performance was successfully validated. The phantom can be employed to verify the output and beam range for ocular proton therapy.