• Title/Summary/Keyword: Passive sampling

Search Result 109, Processing Time 0.027 seconds

Evaluation of a Diffusive Sampler for the Measurement of Formaldehyde using Colorimetric Method (흡광광도법을 이용한 포름알데히드 확산측정기의 평가)

  • Yim, Bong-Been;Kim, Sun-Kyu;Jung, Eui-Suk;Kim, Sun-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.606-613
    • /
    • 2005
  • The badge-type diffusive sampler for the measurement of formaldehyde in indoor air using three types of colorimetric methods such as chromotrophic acid(CTA), 3-methyl-2-benzothiazolinone hydrazone(MBTH), and 4-amino-3-hydrazino-5-mercapto-1,2,4-triazole(AHMT) method. The washing of the collection filter with several cleaning solution was effected with satisfactory results, regardless of the types of cleaning solutions. The concentrations of absorbance solution in each colorimetric method were experimentally determined by considering the sampling rates. The variation blank values in each colorimetric method was below 15%. As compared with CTA and AHMT methods, the reproducibility of MBTH method was excellent and was below 10% relative standard deviation. The collected formaldehyde mass and time-weighted concentration had a good correlation (correlation coefficient > 0.93). The limit of detection and limit of quantitation, and minimum sampling time were closely correlated to the sampling rates for the measurement of formaldehyde in each method.

Comparison between the Charcoal Tube Sampling Method and the Diffusive Sampler, and the Applicability of Diffusive Sampler in the Field (확산형포집기(3M OVM #3500)와 활성탄관의 유기용제 포집농도 비교 및 확산형포집기의 현장 적용 가능성)

  • Jang, Sung Ho;Kim, Hyoung-Ah
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.261-269
    • /
    • 2005
  • To investigate the field applicability of a diffusive sampler (3M OVM #3500, passive sampling method) authors conducted a simultaneous measurement of personal organic solvents exposure in the air of the workplaces by charcoal tube with low volume sampler (active sampling method) and diffusive sampler. Samples were collected and analyzed by NIOSH method ($NMAM^{(R)}$) from thirty-eight workers in 12 factories who work in 6 different processes. Geometric mean (GM) and geometric standard deviation (GSD) were used to describe the result. To compare the results of the two methods, paired t-test was used. According to the manual of the exposure assessment of the mixed organic solvents (Ministry of Labor, Korea), Em was calculated. Simple linear regression was used to evaluate the relationship between the two methods. Results were as follows; 1. Eight different solvents (ethyl acetate, n-hexane, toluene, xylene, acetone, isopropyl alcohol, methyl ethyl ketone (MEK), and methyl isobutyl ketone) were detected simultaneously in the two methods and the concentrations of the personal exposure were lower than 0.5 TLV level. The concentration of the charcoal tube method was higher than that of a diffusive sampler in n-hexane and MEK (p<0.05). 2. Em of the charcoal tube method was higher than that of diffusive sampler method but not significantly different and was lower than the OEL (Occupational Exposure Limit) in all 6 processes. 3. There was a significant correlation between the two methods in low concentrations of the 8 organic solvents (p<0.05). In conclusion, there was no difference in charcoal tube method and diffusive sampler method in low concentrations of some organic solvents, diffusive sampler can be applied to assess the personal monitoring in low level exposure.

MCS/IEI and Personal Exposures of VOCs in Office Worker (사무직 종사자가 일상생활에서 노출되는 VOCs 농도와 화학물질과민증 자각증상에 관한 연구)

  • Choi, Yoo-Rim;Sung, Ki-Chul;Chun, Chung-Yoon;Park, Jun-Seok
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.322-327
    • /
    • 2006
  • In our previous research, office workers are relatively frequent in self-reported symptoms suggestive of MCS/IEI compare to construction worker who highly exposed to VOCs compounds. However in that research, the subjects were too small to say it clearly. Based on that research results, self reported symptom surveys to 110 office workers and personal exposure concentration measurement were conducted to 13 of people. VOCs exposure levels were measured within office, house and other places during a week by Passive Sampling Method. In this study, it was found that the number of office workers who met the operational criteria of MCS/IEI was 23.6% similar to 24.5% of previous result, and average of TVOC concentration was appeared high state by order of office, house, and personal exposure.

  • PDF

Indoor and Outdoor Formaldehyde Concentrations in Underground Environments (실내외 포름안데히드 농도에 관한 조사연구)

  • 김윤신;김미경
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.2
    • /
    • pp.1-9
    • /
    • 1989
  • A pilot study was conducted in order to measure indoor and outdoor formaldehyde levels during August 3 - 22, 1988 in several underground spaces in Seoul. Formaldehyde concentrations were monitored during 1 week in selected sampling areas (subway station, underground shopping center, underpass, tunnel, underground parking lot) using passive formaldehyde monitors. In order to investigate a relationship between respiratory prevalence and levels of formaldehyde, each subject was asked to answer respiratory questions. The mean formaldehyde concentrations were 60.1 ppb in subway station, 122.2 ppb in underground shopping stores, 72.1 ppb in underpasses, 39.7 ppb in tunnel, and 75.9 ppb in underground parking lots, respectively. The mean indoor formaldehyde concentrations in underground environments varied from 28.6 ppb to 118.7 ppb. Generally, the mean formaldehyde concentrations in ticketing office in subway stations appeared higher than those level measured in platform. The mean formaldehyde concentrations of underground shopping center in Gangnam Terminal were higher than any other areas and it exceeded 100 ppb of the American Ambient Air Quality Standards of formaldehyde. Prevalence rates of respiratory symptoms of dwellers seemed to be related to higher indoor formaldehyde levels.

  • PDF

Hybrid-Type Active Power Filters for Compensating Harmonic Current and Unbalanced Source Voltages (고조파 전류와 불평형 전원전압 보상을 위한 복합형 능동전력 필터)

  • Lee, Ji-Myeong;Lee, Dong-Chun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.5
    • /
    • pp.249-257
    • /
    • 2002
  • In this paper, a novel control scheme compensating source voltage unbalance and harmonic currents for the combined system of series active and shunt passive power filter is proposed, where no low/high-pass filters are used in deriving the reference voltage for compensation. The phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage set, which is simply obtained by using digital all-pass filters. In order to remove the phase delay in generating the reference voltage for compensation, the reference of 5th and 7th harmonic components is predicted one-sampling ahead. The validity of the proposed scheme has been verified for 3[kVA] proto-type active power filter system.

Optimal Design of Discrete Time Preview Controllers for Semi-Active and Active Suspension systems

  • Youn, Il-Joong
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.8
    • /
    • pp.807-815
    • /
    • 2000
  • In this paper, modified discrete time preview control algorithms for active and semi-active suspension systems are derived based on a simple mathematical 4 DOF half-car model. The discrete time preview control laws for ride comfort are employed in the simulation. The algorithms for MIMO system contain control strategies reacting against body forces that occur at cornering, accelerating, braking, or under payload, in addition to road disturbances. Matlab simulation results for the discrete time case are compared with those for the continuous time case and the appropriateness of the discrete time algorithms are verified by the of simulation results. Passive, active, and semi-active system responses to a sinusoidal input and an asphalt road input are analysed and evaluated. The simulation results show the extent of performance degradation due to numerical errors related to the length of the sampling time and time delay.

  • PDF

Motion analysis system using image processing (화상처리를 이용한 동작분석 시스템에 관한 연구)

  • 박경수;반영환;이안재;임창주;오인석;이현철
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.71-75
    • /
    • 1997
  • This paper presents the development of videobased 3-dimensional tracking system. Measurement of human motion is important in the application of ertonomics. The system uses advanced direct video measurement technology. Passive retro-reflecting markers are attached to a subject and movements of markers are observed by two CCD cameras. Infrared light emitted near the CCD cameras is reflected by the markers and is detected by the cameras. The images are captured by Samsung MVB302 board and the centers of markers are calculated by DSP program. The positions of markers are transferred from MVB02 board to the computer through AT bus. The computer then tracks the position of each marker and saves the data. This system has dynamic accuracy with 0.7% average error and 4.2% maximum error, and the sampling rate to 6 .approx. 10 Hz, and this system can analyse the trajectory and speed of the marker. The results of this study can be used for operator's motion analysis, task analysis, and hand movement characteristic analysis.

  • PDF

Video-based 3-dimensional tracking system (영상을 이용한 3차원 위치 추적 시스템 개발1)

  • 박경수;반영환;이안재;임창주
    • Proceedings of the ESK Conference
    • /
    • 1996.10a
    • /
    • pp.160-165
    • /
    • 1996
  • This paper presents the development of video-based 3-dimensional tracking system. Measurement of human motion is important in the application of ergonomics. The system uses advanced direct video measurement technology. Passive retro-reflecting markers are attached to a subject and movements of markers are observed by two CCD cameras. Infrared light emitted near the CCD cameras is reflected by the markers and is detected by the cameras. The image ae captured by Samsung MVBO2 board and the center of markers is calculated by DSP program. The position of markers are transferred from MVB02 board to the computer through AT bus. The computer then tracks the position of each marker and saves the data. This system has dynamic accuracy with 1% error and the sampling rate to 6-10 Hz, and can analyse the trajectory and speed of the marker. The results of this study can be used for operators motion analysis, task analysis, and hand movement characteristic analysis.

  • PDF

Health Promoting Behaviors and Influencing Factors of University Students: Optimism and Coping Skills (대학생의 건강증진행위와 영향요인: 낙관성과 대처능력을 중심으로)

  • Kim, Nam-Sun
    • Korean Journal of Adult Nursing
    • /
    • v.19 no.5
    • /
    • pp.37-46
    • /
    • 2007
  • Purpose: The purpose of this descriptive study was to identify predictors on health promoting behaviors of university students. Methods: The participants were 310 students by convenience sampling in G city. The data were collected through a questionnaire given to the students between September 10 to November 6, 2006. Descriptive statistics, t-test, ANOVA, Pearson's correlation coefficients, and stepwise multiple regression were used to analyze the data. Results: The mean score for the level of health promoting behaviors and optimism was 2.60(${\pm} .31$) and 2.70(${\pm} .55$) respectively. The most frequently used coping skill was the pursuit of social support. There were positive correlations between health promoting behaviors and optimism, between health promoting behaviors and active coping skill, and between health promoting behaviors and passive coping skill. In stepwise multiple regression analysis, the most powerful predictor of health promoting behaviors was active coping skill. Conclusion: The results suggest that coping skills with optimism can be considered when developing a health promotion program for university students.

  • PDF

Numerical study on CMT boron replenishment strategy for an AP1000 nuclear power unit

  • Wang, Hong;Zhang, Miao;Li, Jialong;Wang, Junpeng
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2321-2328
    • /
    • 2022
  • The passive safety system is adopted in an AP1000 nuclear power unit to improve the operation safety of the whole unit. However, due to boron diffusion and periodic sampling, boron dilution occurs in the core makeup tank. The boron replenishment process in the core makeup tank is essential and becomes particularly important. Based on the validated models, this article numerically investigates the influence of the replenishment flow rate and the position on the boron distribution in the core makeup tank. The thermal fatigue phenomenon of the "T" connection caused by replenishment is analyzed. Finally, the replenishment strategy is proposed to benefit both boron mixing in the core makeup tank and eliminating the thermal fatigue of the "T" connection.