• Title/Summary/Keyword: Passive safety system

Search Result 231, Processing Time 0.046 seconds

An Experimental Study on the Development of a Cabin Noise Reduction System for Improving Ship Habitability (선박 거주성 향상을 위한 선실 소음 저감 시스템 개발에 관한 실험적 연구)

  • Young-Choul Seo;Deug-Bong Kim;Chol-Seong Kim
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.620-627
    • /
    • 2023
  • Ship noise is one of the important factors for the living and health of seafarers, and ef orts to reduce ship noise are actively underway. There are two methods of noise reduction: passive noise Control (PNC) and active noise control (ANC). Unlike cars and airplanes, ANC is not widely used for noise reduction on ships. This study aimed to reduce the noise generated in the engine room by using soundproof panels and high-frequency vibration generators, as well as active noise control (ANC). For this purpose, an experimental model was made using an acrylic box, and the noise reduction effect was measured under four conditions. The experimental results are as follows: First, the soundproof panel had a noise reduction effect in all ranges from 55 dB to 85 dB. In the case of using a high-frequency vibration generator, there was no ef ect in the low noise range such as 55 dB(A), but there was a noise reduction effect in the high noise range such as 70.8 dB(A) and 85 dB(A).Second, when the soundproof panel and the high-frequency vibration generator were used simultaneously, the noise reduction ef ect was up to -2.2 dB(A). The results of this experiment were obtained from an experimental model made of acrylic, and they may be different from actual ships made of steel plate. In future studies, we plan to experiment using iron plate (considering the material, thickness, and structure) used in actual ships. We hope that this study will help to improve the living environment and health of seafarers on ships.

IDENTIFICATION AND ASSESSMENT OF AGING-RELATED DEGRADATION OCCURRENCES IN NUCLEAR POWER PLANTS

  • Choi, In-Kil;Choun, Young-Sun;Kim, Min-Kyu;Nie, Jinsuo;Braverman, Joseph I.;Hofmayer, Charles H.
    • Nuclear Engineering and Technology
    • /
    • v.44 no.3
    • /
    • pp.297-310
    • /
    • 2012
  • Aging-related degradation of nuclear power plant components is an important aspect to consider in securing the long term safety of the plant, especially the seismic safety, since the degradation of the components affects not only their seismic capacity but their response. This can cause a change in the seismic margin of a component and the overall seismic safety of a system. To better understand the status and characteristics of degradation of components in Nuclear Power Plants (NPPs), the degradation occurrences of components in the U.S. NPPs were identified by reviewing recent publicly available information sources and the characteristics of these occurrences were evaluated and compared to observations from the past. Ten categories of components that are of high risk significance in Korean NPPs were identified, comprising anchorage, concrete, containment, exchanger, filter, piping systems, reactor pressure vessels, structural steel, tanks, and vessels. Software tools were developed to expedite the review process. Results from this review effort were compared to previous data in the literature to characterize the overall degradation trends.

KTX-II RAMS Application Standard for Safety of Passenger Transportation Service (안전한 고객수송서비스를 위한 KTX-II RAMS 적용기준)

  • Cha, Jae-Hwan;Chung, In-Soo;Jo, Kwang-Woo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1525-1538
    • /
    • 2008
  • Currently, it has been a fashion to include RAMS of rolling stock in the order for purchasing the rolling stock. However, it's only to suggest a qualitative value or an ideal target without giving or demonstrating actual RAMS target, with only demonstrating passive RAMS by the data provided by the manufacturer. In the case of KTX project of 100 cars of KTX-II contracted in June 2006, their target has been suggested from the previous RAMS application standard and it aimed to achieve the reliability level of equivalent high speed rolling stock. Afterward, as actual KTX-II RAMS Plan and RAMS Demonstration Plan has been prepared and approved, it has been the first problem to secure the reliability and safety in order to introduce the new high speed rolling stock(KTX-II) successfully and we actually tried to apply overseas RAMS standard, KTX samples, electric railcar MTRC and rolling stock samples. This Report was dealt world trends of Railway RAMS standard, KTX-II RAMS Specifications, the present condition of KTX-II RAMS performance and development a way of KTX-II RAMS, We hope the "KTX-II RAMS Application Standard for Safety of Passenger Transportation Service" is served as an opportunity for the basic research for establishing and demonstrating RAMS target of components or parts composing the rolling stock system.

  • PDF

Aerodynamic performance evaluation of different cable-stayed bridges with composite decks

  • Zhou, Rui;Ge, Yaojun;Yang, Yongxin;Du, Yanliang;Zhang, Lihai
    • Steel and Composite Structures
    • /
    • v.34 no.5
    • /
    • pp.699-713
    • /
    • 2020
  • The aerodynamic performance of long-span cable-stayed bridges is much dependent on its geometrical configuration and countermeasure strategies. In present study, the aerodynamic performance of three composite cable-stayed bridges with different tower configurations and passive aerodynamic countermeasure strategies is systematically investigated by conducting a series of wind tunnel tests in conjunction with theoretical analysis. The structural characteristics of three composite bridges were firstly introduced, and then their stationary aerodynamic performance and wind-vibration performance (i.e., flutter performance, VIV performance and buffeting responses) were analyzed, respectively. The results show that the bridge with three symmetric towers (i.e., Bridge I) has the lowest natural frequencies among the three bridges, while the bridge with two symmetric towers (i.e., Bridge II) has the highest natural frequencies. Furthermore, the Bridge II has better stationary aerodynamic performance compared to two other bridges due to its relatively large drag force and lift moment coefficients, and the improvement in stationary aerodynamic performance resulting from the application of different countermeasures is limited. In contrast, it demonstrates that the application of both downward vertical central stabilizers (UDVCS) and horizontal guide plates (HGP) could potentially significantly improve the flutter and vortex-induced vibration (VIV) performance of the bridge with two asymmetric towers (i.e., Bridge III), while the combination of vertical interquartile stabilizers (VIS) and airflow-depressing boards (ADB) has the capacity of improving the VIV performance of Bridge II.

Prediction of radioactivity releases for a Long-Term Station Blackout event in the VVER-1200 nuclear reactor of Bangladesh

  • Shafiqul Islam Faisal ;Md Shafiqul Islam;Md Abdul Malek Soner
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.696-706
    • /
    • 2023
  • Consequences of an anticipated Beyond Design Basis Accident (BDBA) Long-Term Station Blackout (LTSBO) event with complete loss of grid power in the VVER-1200 reactor of Rooppur Nuclear Power Plant (NPP) of Unit-1 are assessed using the RASCAL 4.3 code. This study estimated the released radionuclides, received public radiological dose, and ground surface concentration considering 3 accident scenarios of International Nuclear and Radiological Event Scale (INES) level 7 and two meteorological conditions. Atmospheric transport, dispersion, and deposition processes of released radionuclides are simulated using a straight-line trajectory Gaussian plume model for short distances and a Gaussian puff model for long distances. Total Effective Dose Equivalent (TEDE) to the public within 40 km and radionuclides contribution for three-dose pathways of inhalation, cloudshine, and groundshine owing to airborne releases are evaluated considering with and without passive safety Emergency Core Cooling System (ECCS) in dry (winter) and wet (monsoon) seasons. Source term and their release rates are varied with the functional duration of passive safety ECCS. In three accident scenarios, the TEDE of 10 mSv and above are confined to 8 km and 2 km for the wet and dry seasons, respectively in the downwind direction. The groundshine dose is the most dominating in the wet season while the inhalation dose is in the dry season. Total received doses and surface concentration in the wet season near the plant are higher than those in the dry season due to the deposition effect of rain on the radioactive substances.

Reactogenicity to COVID-19 vaccination in the United States of America

  • Adekunle Sanyaolu;Aleksandra Marinkovic;Stephanie Prakash;Priyank Desai;Nafees Haider;Abu Fahad Abbasi;Nasima Mehraban;Isha Jain;Amarachi Ekeh;Omar Shazley;Chuku Okorie;Verner N. Orish
    • Clinical and Experimental Vaccine Research
    • /
    • v.11 no.1
    • /
    • pp.104-115
    • /
    • 2022
  • Purpose: In the United States, Pfizer-BioNTech, Moderna, and Janssen's coronavirus disease 2019 (COVID-19) vaccines have been granted Emergency Use Authorization (EUA) with the Pfizer-BioNTech vaccine presently approved by the US Food and Drug Administration. The purpose of this study is to analyze passive surveillance data on COVID-19 vaccine adverse reaction in the United States. Materials and Methods: We analyzed passive surveillance data on COVID-19 vaccine adverse reactions which were retrieved from the Vaccine Adverse Event Reporting System database. Retrieved records on demographic information as well as the top 10 common vaccine adverse events were extracted and assessed from 200 of the most recently reported cases for the study analysis. Results: Local and systemic adverse reactions were reported in the study. A significant difference (p<0.05) was recorded for the top 10 systemic reactions by age category (0.041) and by gender (0.002). Analysis of the top five systemic reactions, stratified by vaccine type yielded a significant difference (p<0.05) for chills (p=0.044), and when stratified by age group and type of vaccination received, it yielded a significant difference (p<0.05) for fatigue (p=0.023). Overall, Pfizer had 182 persons (91.0%) reporting adverse events, Moderna with 13 (6.5%), and Janssen with 5 (2.5%). Conclusion: Mild side effects were reported following vaccination with the EUA COVID-19 vaccines in the United States. Thus, continuous monitoring and reporting of all adverse events are recommended to ensure the safety of vaccination.

Damper Configuration for Seismic Performance Improvement of Heavy Facilities with Frictional Sliding Behavior inside Building (마찰 슬라이딩 거동을 보이는 건물 내 중량 설비의 내진성능 향상을 위한 감쇠기 연결 방안)

  • Ok, Seung-Yong;Park, Kwan-Soon;Lee, Jeeho
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.1
    • /
    • pp.53-61
    • /
    • 2020
  • This study proposes a new damper configuration for seismic performance improvement of heavy sliding facilities inside a building. For this purpose, we deal with two connection types of control system, and the parametric study has been performed to investigate their comparative seismic performances according to the variations of the control capacity. In order to simulate the seismic responses of the proposed system, we employed a recently-developed seismic response analysis method that can deal with the two-mass system with nonlinear frictional sliding behavior. The numerical results demonstrate that the typical method of diagonal bracing damper connection can exhibit effective control performance both on structure and the heavy sliding facilities, whereas the structure-facilities connection method does not show any control effect on both responses. On the other hand, the typical method has some limitations that it can adversely cause excessive sliding of the facilities, depending upon the frequency characteristics of structure and earthquake. On the contrary, the structure-facilities connection method is very effective in reducing the sliding displacement of the heavy facilities, even with small amount of control capacity. Thus, the following potential expectations can be inferred from these results: The typical diagonal bracing damper connection method will have some promising benefits in controlling the sliding facilities inside the building as well as the building itself, and the structure-facilities connection method can be a cost-effective way of protecting the internal heavy important facilities inside the structure already designed with sufficient seismic performance.

A Study on Battery Charging System for Improving Battery Safety and Efficiency (배터리 안전 및 효율향상을 위한 배터리 충전시스템에 관한 연구)

  • Jeon, Chan Young;Park, SangUk;Mok, HyungSoo
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.457-458
    • /
    • 2019
  • 최근 산업의 발전과 함께 고용량의 높은 에너지 밀도의 배터리에 대한 요구가 증가함에 따라 배터리의 빠르고 안정적인 충전에 관한 다양한 요구들이 발생하고 있다. 배터리는 하나의 셀이 아닌 다중 셀의 집합체로써 안정적인 충전을 위해서는 주별 셀 간의 밸런스 유지가 중요 요소이다. 이를 위하여 배터리 관리 시스템인 BMS(Battery Management System)는 배터리 셀의 밸런스 유지를 위한 다양한 방법들을 적용하여 왔다. 그 대표적인 방법으로 저항을 통해 밸런스를 조절하는 Active 방식과 셀간 에너지 교환을 실시하는 Passive 방식이 있다. 그러나 이러한 방법들은 효율 및 수명, 시간 등의 문제가 제기되었다. 이에 따라 본 논문에서는 배터리 셀 Level에서의 새로운 충전 방안을 제시하였으며, 이를 실제적인 시험 시스템을 통하여 그 성능을 입증하였다.

  • PDF

SEPARATE AND INTEGRAL EFFECT TESTS FOR VALIDATION OF COOLING AND OPERATIONAL PERFORMANCE OF THE APR+ PASSIVE AUXILIARY FEEDWATER SYSTEM

  • Kang, Kyoung-Ho;Kim, Seok;Bae, Byoung-Uhn;Cho, Yun-Je;Park, Yu-Sun;Yun, Byoung-Jo
    • Nuclear Engineering and Technology
    • /
    • v.44 no.6
    • /
    • pp.597-610
    • /
    • 2012
  • The passive auxiliary feedwater system (PAFS) is one of the advanced safety features adopted in the APR+, which is intended to completely replace the conventional active auxiliary feedwater system. With an aim of validating the cooling and operational performance of PAFS, an experimental program is in progress at KAERI, which is composed of two kinds of tests; the separate effect test and the integral effect test. The separate effect test, PASCAL ($\underline{P}$AF$\underline{S}$ $\underline{C}$ondensing Heat Removal $\underline{A}$ssessment $\underline{L}$oop), is being performed to experimentally investigate the condensation heat transfer and natural convection phenomena in PAFS. A single, nearly-horizontal U-tube, whose dimensions are the same as the prototypic U-tube of the APR+ PAFS, is simulated in the PASCAL test. The PASCAL experimental result showed that the present design of PAFS satisfied the heat removal requirement for cooling down the reactor core during the anticipated accident transients. The integral effect test is in progress to confirm the operational performance of PAFS, coupled with the reactor coolant systems using the ATLAS facility. As the first integral effect test, an FLB (feedwater line break) accident was simulated for the APR+. From the integral effect test result, it could be concluded that the APR+ has the capability of coping with the hypothetical FLB accident by adopting PAFS and proper set-points of its operation.

Function Analysis for the active surveillance system of urban transit (도시철도의 능동적 감시체계를 위한 기능 분석)

  • An, Tae-Ki;Shin, Jeong-Ryul;Lee, Woo-Dong;Han, Seok-Yoon;Kim, Moon-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1027-1028
    • /
    • 2008
  • Most of the urban transit operation company in Korea have a passive surveillance system to monitor the status of the passengers and facilities in the urban transit service area. The surveillance system is based on CCTV, closed circuit television, and several sensors, such as a fire sensor. However, this system has some limitations to prevent and cope with the emergency quickly. So the urban transit operation companies have plans to be change their surveillance system to be active. The active surveillance system has an intelligent function to detect the event predefined by managers automatically. To construct the active surveillance system, there are a standard concept design and a function analysis. In this paper, we propose the classification of the functions of the active surveillance system for urban transit. We divide the functions into five parts, ordinary monitoring, safety monitoring, environment monitoring, administration support, and record management. And we describe the systems related to the every functions to clarify the classified functions.

  • PDF