• Title/Summary/Keyword: Passive monitoring

Search Result 223, Processing Time 0.019 seconds

Evaluation of Passive Sampler as a Useful Tool for Environmental Education (환경교육의 도구로서 간이 측정기의 활용에 관한 연구)

  • 전의찬;송민종
    • Hwankyungkyoyuk
    • /
    • v.11 no.2
    • /
    • pp.252-261
    • /
    • 1998
  • Since 1980's during which environmental pollution became serious enough to urge various types of environmental educations in many areas. But, most emphasis has been put on theoretical education. Even field education training mostly focused on water pollution. Therefore, simple air pollution monitoring system was needed for better field education in air pollution. In this study, we evaluated Passive Sampler as an useful tool for teaching air pollution in field. Students have found passive sampler very effective tool. Recent comparative study of auto-monitoring and passive sampler networks suggested a potential use of passive sampler as an useful tool for environmental education. In this study, the correlation between two sets of values appears very high judging from the regression slope of 0.92 and correlation coefficient of 0.91 However, inexpensive Passive sampler with easy-to-operate colorimeter, has not been used in environmental education partially because large scale fluctuation in time and space characteristic to air pollution has been overlooked so that the sampler has not been tested for an effective educational tool. Passive sampler certainly deserves further in depth research as an effective air monitoring system, and better attention to its usefulness to teach students and public.

  • PDF

Real-time Monitoring of Ethernet Passive Optical Network Using Burst-mode FBGs

  • Binh, Nguyen Khac;Choi, Su-il
    • Current Optics and Photonics
    • /
    • v.4 no.3
    • /
    • pp.186-192
    • /
    • 2020
  • This paper describes a real-time monitoring system in Ethernet passive optical networks (EPON) that uses burst-mode fiber Bragg grating (FBG) optical sensors. The FBG interrogation unit in the optical line terminal (OLT) transmits the monitoring wavelength to optical network units (ONUs). The FBG sensor unit in each ONU returns a burst-mode monitoring signal to the OLT. As the system applies time division multiple access (TDMA), a uniform Bragg wavelength can be used to monitor the EPON system. The FBG interrogation unit analyzes the received burst-mode monitoring signals and outputs fault information on the ONU branches in EPON. The simulation results show the effectiveness of the proposed monitoring system based on TDMA. In addition, we compared the proposed TDMA-based monitoring system with a WDMA-based monitoring system.

Uniform-fiber-Bragg-grating-based Fabry-Perot Cavity for Passive-optical-network Fault Monitoring

  • Xuan, Zhang;Ning, Ning;Tianfeng, Yang
    • Current Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.47-53
    • /
    • 2023
  • We propose a centralized passive-optical-network monitoring scheme using the resonance-spectrum properties of a Fabry-Perot cavity based on fiber Bragg gratings. Each cavity consists of two identical uniform fiber Bragg gratings and a varying cavity length or grating length, which can produce a unique single-mode resonance spectrum for the drop-fiber link. The output spectral properties of each cavity can be easily adjusted by the cavity length or the grating length. The resonance spectrum for each cavity is calculated by the transfer-matrix method. To obtain the peak wavelength of the resonance spectrum more accurately, the effective cavity length is introduced. Each drop fiber with a specific resonance spectrum distinguishes between the peak wavelength or linewidth. We also investigate parameters such as reflectivity and bandwidth, which determine the basic performance of the fiber Bragg grating used, and thus the output-spectrum properties of the Fabry-Perot cavity. The feasibility of the proposed scheme is verified using the Optisystem software for a simplified 1 × 8 passive optical network. The proposed scheme provides a simple, effective solution for passive-optical-network monitoring, especially for a high-density network with small end-user distance difference.

A Study of Ozone Passive Sampler(I)-Sensitivity on Filter Substrate (오존 간이측정기에 대한 연구(I)-필터의 민감도)

  • 정상진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.383-391
    • /
    • 2002
  • Six types of ozone passive samplers were fabricated with three different filter substrates and two colorants, and tested for their feasibility on atmospheric monitoring. These passive samplers are based on a colorant which fades (indigo carmine and ChromAir (K&M environmental Inc.)) or produces color (mixture of 3-methyl-2-benzothiazolinone acetone azine and 2-phenylphenol colorant) upon reaction with ozone, whose concentration can be determined by reflectance measurement of the color change. Three filters, namely Whatman No.1 paper, SG81 chromatography paper and Silica Gel coated on polyester (TLC Plates), were prepared and coated with two colorants. The response of these passive samplers in ozone chamber were tested and compared with ChromAir (K&M environmental Inc.) passive sampler. The response of Silica Gel filter impregnated with indigo carmine was the best at the constant concentration exposure.

A Study on the Monitoring System of Passive Filter to Improve Power Quality (전력품질 개선을 위한 수동필터 모니터 시스템에 관한 연구)

  • Yu, Jae-Geun;Lee, Sang-Ik;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.89-91
    • /
    • 2007
  • In this paper, we developed DSP based control system to automatically open and close passive filter, which is used to reduce harmonics, according to operating condition of loads. Passive filter control system automatically open and close each branch of filter according to working conditions of loads by sending signals to open and close installation of passive filter after measuring and monitoring voltage, current, harmonics, reactive power, power factor and so on. We verified it's performance by connecting control system with passive filter in the power line using the 100[HP] d.c. motor drive, opening and closing passive filter according to operation condition of motor, and measuring harmonics and reactive power, etc.

  • PDF

Air Monitoring of Persistent Organic Pollutants Using Passive Air Samplers (Passive Air Sampler를 이용한 잔류성 유기오염물질의 대기 모니터링)

  • Choi, Sung-Deuk;Chang, Yoon-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.5
    • /
    • pp.481-494
    • /
    • 2005
  • The monitoring of persistent organic pollutants (POPs) in the atmosphere is a basis for the study of the fate of POPs in multimedia environments. Recently, passive air samplers (PASs) for POPs have been developed. In this paper, we deal with the principle, properties, and applications of the PAS. The principle of PAS, which has no pump, is physical sorption of semi-volatile organic chemicals on various sorbent materials. The PAS is much smaller than a high-volume air sampler and does not need electricity. These properties of the PAS make it possible to conduct various-scaled environmental monitoring all over the world including the Arctic and Antarctic, but the major disadvantage of PAS is its long sampling periods up to 2 years. To date, four kinds of PAS have been developed: polyurethane foam (PUF), polymer-coated glass (POG), semi-permeable membrane devices (SPMDs), and XAD resin-based PAS. Among them, SPMDs have been commercialized and are most widely used now. Meanwhile, the POPs emitted from China have a large potential to influence the levels and fates of POPs in Korea. Since characteristics of PAS are quite useful to monitor long-range transport of POPs, the use of PAS is highly recommended.

A Comparative Evaluation of Sampling Methods for Airbone Mercury Concentration (공기중 수은 농도의 측정방법에 대한 비교평가연구)

  • Park, Ju Young;Kim, Kwang Jong;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.184-192
    • /
    • 1995
  • This study was performed to evaluate methods for determination of airbone mercury in industrial environments. Three methods, such as Hopcalite method, passive monitoring method and Jerome method were evaluated at two (2) fluorescent lamp manufacturing Plants in Korea during a period from May 24 to May 31, 1994 and the result are as follows: 1. The average were concentrations of airbone mercury were $26{\mu}g/m^3$ by Hopcalite method, $25{\mu}g/m^3$ by passive monitoring method, and $38{\mu}g/m^3$ by the Jerome method, respectively, which were below the permissible exposure limit of $50{\mu}g/m^3$ established by both the Korean Ministry of Labor and ACGIH. However, 12 out of 49 cases(24.4%) in plant A and 2 out of 31 cases(6.5%) in plant B were in excess of the standard. 2. The relationship between the results by Hopcalite method and the passive monitoring method was significant(r=0.892). 3. The variation among three results by eath of three methods were different by process. The highest variation was determined at quality control process("process b") which invoved in large variation of concentrations. 4. When short term high concentrations were produced, the Hopcalite method was more efficient then the passive method.

  • PDF

Air Quality Evaluation with Passive Samplers for Large Cities (Passive Sampler를 이용한 대도시의 대기질 평가)

  • Jeon, Eui-Chan;Kim, Shin-Do;Choi, Kum-Chan
    • Journal of Environmental Impact Assessment
    • /
    • v.7 no.2
    • /
    • pp.83-88
    • /
    • 1998
  • Filter badge type sampler has not been widely used to evaluate air quality over large cities in Korea while it can be successfully used for multi-point sampling and analysis. We evaluated the passive sampler as a new tool to monitor air quality over large cities. We latticed Metropolitan Seoul into $2{\times}2Km$ to give 136 points. $NO_2$ concentrations were measured at all the points in the Spring and Summer of 1997. According to the passive sampler data, natural green zones generally recorded lower $NO_2$ concentrations than major streets and traffic congestion areas. Passive samplers with abundant 136 points gave more detailed picture of $NO_2$ distribution while auto-monitoring network did not clearly provide the characteristics of local land use. Also, passive samplers gave 15% higher values than auto-monitoring network. The correlation between the two values appears very high judging from the regression slope of 0.92 and correlation coefficient of 0.91. This study clearly demonstrates the effectiveness of the passive sampler as a tool to monitor air quality over large cities.

  • PDF

Evaluation and Complement of the Representativeness of Air Quality Monitoring Stations Using Passive Air Samplers (수동측정기에 의한 대기오염 자동측정망의 지역대표성 조사 및 보완방완에 대한 기초연구)

  • 우정현;김선태;김정욱
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.6
    • /
    • pp.415-426
    • /
    • 1997
  • Some arguments have been about over the representativeness of government-run air quality monitoring stations among scholars and non-governmental organizations (NGOs). However, it is not a simple problem to move monitoring stations because of continuity of data and high cost. So it is necessary to complement the monitoring data if it do not represent the ambient air quality properly. The purpose of this study was to evaluate the representativeness of some monitoring stations using passive $NO_2$ samplers and to find a complementary method from linear regression. Two stations were chosen for the evaluation: Shinlim Station was one of the most controversial stations in Seoul and Banpo Station had the best reputation. Air qualities were surveyed at seven points around each monitoring station with consideration of land use and distance. The ratios of the average $NO_2$ levels of the areas to these at the monitoring stations were 1.59 for Shinlim Station and 1.03 for Banpo Station. The differences between the average $NO_2$ levels and those at the monitoring stations were 10.75 ppb for Shilim Station and 0.34 ppb for Banpo Station. The correlation coefficients between the two levels were 0.7668 for Shinlim and 0.7662 for Banpo. The average coefficients of determination $(R^2)$ were 0.61 for Shinlim and 0.61 for Banpo. The Shinlim Station could not represent the air quality of Shinlim-Dong good because it is located in a green area at an outskirt of Shinlim-Dong. But the Banpo Station located in a central residential area of Banpo-Dong showed a fair representativeness. However, air quality turned out to be different with land use such as residential area, green area or road: the air quality data from a monitoring station located at a certain land use should not be interpreted as representing the air quality at any sites around the station. Equations to predict the average $NO_2$ levels of each area from the data from the monitoring stations were presented based on linear regression.

  • PDF

The Nationwide NO$_2$Monitoring with Passive Sampler in Korea

  • Kim, Sun-Tae;Kim, Han-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E2
    • /
    • pp.69-77
    • /
    • 2002
  • The nationwide NO$_2$monitoring program has been carried out using the passive sampler in Korea since 1993. During the sixteenth periods of measurement, total 26,474 sites of data were collected through eight years. In this paper, the roadside NO$_2$concentration of six major cities were analyzed. As results, the most frequent NO$_2$concentration of Seoul, Incheon, and Daegu ranged from 40 to 60 ppb, and that of Pusan, Kwanju, and Daejeon was from 20 to 40 ppd. Despite that the automobile number of Incheon was less than that of Daegu and Pusan, the exceedence rate of Korean national ambient air quality standard and ninetieth percentile concentration of Incheon were almost the same level as Seoul. In addition, the mean and standard deviation of roadside NO$_2$concentration of Seoul and Incheon was also appeared to be higher than that of other cities. These results indicates that NO$_2$concentration on roadside was affected by the traffic volumes and the traffic flow conditions.