• 제목/요약/키워드: Passive consumption

검색결과 274건 처리시간 0.033초

A Study on Passive Cooling Strategies for Buildings in Hot Humid Region of Nepal

  • Manandhar, Rashmi;Yoon, Jongho
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.53-60
    • /
    • 2015
  • Increase in energy consumption in building is a big concern world over. In Nepal, energy crisis is a big issue but energy demand in buildings is barely even thought about. In the southern part of Nepal, where the weather is mostly hot during the year, cooling in buildings is very important. This is an initial study regarding building design strategies which focuses on cooling energy consumption in the building. It can be seen from the study that simple passive strategies can be applied in building design which can support in decreasing cooling load. Different passive cooling strategies like orientation, building size, thermal mass, window design and two direct cooling strategies have been investigated in this study. Direct cooling strategies like shading and natural cooling helps in passive cooling. Different desing strategies have different impact on the cooling energy requirement and the study shows that thermo physical property of building materials has the maximum effect on the energy consumption of the building. Each design strategy creates and average of 20% decrease in energy consumption, whereas the thermal conductivity can have as much as 10 times more effect on the energy consumption than other design strategies.

패시브 하우스 디자인 요소를 적용한 농촌지역 단독주거건물의 난방에너지 모니터링 연구 (A Study on Heating Energy Monitoring of a Rural Detached House Applying Passive House Design Components)

  • 조경민;이태구;한영해
    • KIEAE Journal
    • /
    • 제13권2호
    • /
    • pp.39-46
    • /
    • 2013
  • Recently, the field of construction is putting a variety of effort into reducing CO2, since global warming is being accelerated due to climate changes and the increase of greenhouse gas. For reduction of CO2 in the field of construction, it is required to make plans to cut down heating energy of buildings and especially, it is urgently needed to cut down energy of residential buildings in rural area where occupies the majority of consumption of petroleum-based energy sources. Therefore, this research compared and analyzed the actual energy consumption, by evaluating energy performance of a detached house applying passive house design components for reduction of energy. As the result, energy consumption showed remarkable differences, according to the operation of a heat recovery ventilation unit which is one of passive house design components, and building energy consumption displayed remarkable differences, too, depending on the difference of airtightness performance during building energy simulation conducted in process of design. Based on these results, the importance of airtightness performance of passive house was verified. The result of the actual measurement of energy consumption demonstrated that LNG was most economical amongst several heat resources yielded, on the basis of LPG source energy consumption measured within a certain period of time, and it was followed by kerosene. LPG was analyzed to have a low economic efficiency, when used for heating.

기혼 여성소비자의 소비스트레스 대처유형과 관련 변수: 사회인구학적 변수, 사회계층, 건강상태 지각 및 소비스트레스를 중심으로 (Consumption Stress Coping Types Among Married Women Consumers and Related Variables: Focused on Socio-economic Variables, Social Class, Perceived Health Status, and Consumption Stress)

  • 복미정;서정희
    • 한국생활과학회지
    • /
    • 제24권1호
    • /
    • pp.25-38
    • /
    • 2015
  • This paper focused to classify the consumption stress coping types among married women consumers and to investigate the differences of socio-economic variables, social class, perceived health status, and consumption stress among coping types. Data were collected from 500 married women through online surveys in South Korea. Two factors of consumption stress(consumption stress before purchase, consumption stress after purchase), and three factors of consumption stress coping(Social support coping, problem solving focused coping, Passive avoidance coping) were identified. K-mean cluster analysis classified into 4 coping types with consumption stress coping. 15% of the sample were included to the passive coping type, and 25% were classified into the ambivalent coping type. 26.8% of the sample were identified to the active coping type, and 35.2% were maladaptive coping type. There were significant differences among the consumption stress coping types on education, family income, social class, health status, consumption stress after purchase. Consumer education programs should develop and implement especially for passive coping type and maladaptive coping type to cope effectively with consumption stress.

기존 농촌주택과 패시브형 주택의 에너지 요구량 비교분석 - PHPP분석을 통한 주택의 기밀성 및 창호성능 분석을 중심으로 (An Analysis of the Building Energy Demand of Rural House and Passive type House - An Analysis of the Airtightness and Window system Performance according to using PHPP)

  • 조경민;이태구;김주수
    • KIEAE Journal
    • /
    • 제11권4호
    • /
    • pp.55-61
    • /
    • 2011
  • Due to global warming issues caused by climate changes which are internationally being highlighted, recently, there are lots of efforts under way to reduce energy consumption in various fields. Currently, 25 percent of energy consumption in Korea are being generated from buildings and especially, nearly 54 percent of them are being consumed by households. This study, therefore, aims to consider energy consumption status in the existing rural houses and analyze structure system performance, window system performance and air-permeability of domestic passive-type buildings using PHPP which is an analysis program of building energy to improve energy consumption problems in rural areas. Then, energy reduction plans in rural houses were proposed, by comparing and analyzing energy reduction of the existing rural houses, based on these data.

건축적 수법을 통한 주택의 에너지 절약 방안에 관한 연구 (A Study on the Energy Saving Methods of a House by Passive System)

  • 김용식
    • 한국주거학회논문집
    • /
    • 제13권2호
    • /
    • pp.73-78
    • /
    • 2002
  • Recently, the energy consumption has been sharply increased and the environmental pollution has been serious, resulted in increased use of fossil fuel. These facts are applied to most fields, and are especially important issues in the field of architecture. The energy consumption rate of building is about 30% of all energy consumption, and the rate of residential is about 20% of the rate of building and is increasing gradually. The purpose of this article is firstly to analyse an actual energy consumption rate of model building and compare it with alternative methods, which are applied passive system to, and secondly to suggest an optimal passive method for saving energy. The conclusion of this study is as follows; 1) As compared with the existing house on actual energy consumption rate, 6% in changing orientation to a south, 9% in using double low-e glazing and 23% in shading is decreased. 2) The change of insulation from 50 to 100mm did not show dramatical difference in energy consumption rate. 3) As changed indoor temperature at 2$0^{\circ}C$ in winter and 27$^{\circ}C$ in summer, the rate shows a reduction of 14% compared with the existing condition.

외피의 Passive Design 요소와 신재생에너지를 적용한 생물안전 밀폐시설의 에너지 시스템 개선방안 연구 (A Study on the Energy Improvement Plan of using Passive Design with Exterior Envelopes and Renewable Energy for Bio Safety Labotratory)

  • 황지현;범도;홍진관
    • 설비공학논문집
    • /
    • 제26권10호
    • /
    • pp.491-496
    • /
    • 2014
  • In general, the entire air supply of a bio-safety laboratory (BSL) should be exhausted on the outside to ensure bio-safety, and the air conditioning system should always be operated to maintain a difference in the room pressure. As a result, the annual energy consumption of such a building is approximately five or ten times higher than that of an office building of the same magnitude. Thus, this study applies an actual operating system that targets BSL. The energy consumption is analyzed using the Energy Plus V8.0 program (an energy analysis program), and five kinds of cases that depend on the energy consumption of the basic BSL system are also analyzed. As a result, the energy consumption in Case 1 (basic system) is of 324.95 GJ. When the basic system of Case 1 is compared to that in Case 2 (basic system+passive design with exterior envelopes), an annual energy savings of is 6.9% is achieved. For Case 3 (basic system+Photovoltaic, PV) 12.7% is achieved, and for Case 4 (Solar Geothermal Hybrid System of renewable energy, SGHS) 49.5% is achieved. If a passive design with exterior envelopes and renewable energy system (PV+SGHS) is combined, as in Case 5, the energy consumption would be 118.15 GJ. Therefore, when this last system is compared to a basic system, the passive design with exterior envelopes and renewable energy system (PV+SGHS) can reduce energy consumption by 63.6%.

농촌주민의 여가소비유형과 만족도 (Rural Residents' Leisure Satisfactions and Types by Social demographics in Korea)

  • 조영숙;이문주;황대용
    • 농촌지도와개발
    • /
    • 제16권4호
    • /
    • pp.1021-1048
    • /
    • 2009
  • Based on Rural living indicator -2005 survey data, in RDA this study attempted to investigate Rural Residents' real life satisfaction or identity model by the types of leisure consumption depending on each generation and explored the relationship between leisure consumption and the enhancement of self-identity/ interpersonal relationship, and that between leisure consumption satisfaction and real life satisfaction. Based on systematic random sampling with constructed questionnaires, 1,870 data were collected and analyzed. Overall, the results of this study showed that there are statistically significant differences between generation in leisure consumption. In detail, the findings of this study are as follows. The types of Rural Residents' leisure consumption can be divided into three styles including Semi-leisure type, Passive leisure type and Total leisure type consumption. The preferred types of leisure consumption of Rural Residents' were Semi-leisure type, Passive leisure type and Total leisure type in order. Except for times-pending leisure culture consumption, Semi-leisure type and Passive leisure type influenced on the enhancement of self-identity and interpersonal relationship, then the enhancement of self-identity and interpersonal relationship influenced on leisure consumption-satisfaction, and finally leisure consumption satisfaction influenced on real life satisfaction.

  • PDF

Eating habits and dietary supplement utilization according to food-related lifestyle among Korean adults: a cross-sectional study

  • EunJung Lee;Jin A Jang;Ji-Myung Kim
    • 대한지역사회영양학회지
    • /
    • 제29권4호
    • /
    • pp.253-264
    • /
    • 2024
  • Objectives: This study investigated the association between eating habits and the utilization of dietary supplements (DSs) according to food-related lifestyle (FRL) among Korean adults. Methods: This study included a total of 300 participants (150 men and 150 women) in their 20s to 60s living in Seoul and Gyeonggi Province. We identified two groups by factor and cluster analysis: an 'active pursuit' group and a 'passive pursuit' group. Differences in eating habits and DS utilization between the two groups were analyzed by chi-square test and t-test. Logistic regression analysis was used to analyze the effect of variables on DS consumption according to FRL. Results: There were significant differences between the two groups in terms of age, alcohol drinking frequency, total dietary score, change in DS consumption after coronavirus disease 2019, and current DS consumption (P < 0.05). The proportion who perceived many health benefits of DSs was higher in the 'active pursuit' group than in the 'passive pursuit' group (P = 0.003). The most commonly consumed type of DSs was multivitamins & minerals for the 'active pursuit' group, and omega-3 fatty acids for the 'passive pursuit' group. The 'an active pursuit' group consumed DSs 2.93 times more (95% confidence interval [CI]: 1.44-5.97) compared to the 'passive pursuit' group, after adjusting for confounders. In the 'active pursuit' group, the health pursuit (odds ratio [OR] = 6.54, 95% CI: 1.44-29.61) and rational consumption pursuit factors (OR = 0.26, 95% CI: 0.08-0.83) were associated with DS consumption, whereas only the health pursuit factor had a significant association (OR = 5.37, 95% CI: 2.08-13.88) within the 'passive pursuit' group. However, total dietary score and DSs consumption did not show a relationship. Conclusions: By understanding the consumption characteristics of DSs according to FRL, this can serve as basic data necessary for promoting health through the utilization of DSs and healthy behaviors.

사무용 건물의 에너지 절감을 위한 요소별 성능 분석 및 디자인 전략에 관한 연구 (Study of Design Strategy to Reduce Energy Consumption in a Standard Office Building)

  • 양자강;김철호;김강수
    • KIEAE Journal
    • /
    • 제16권2호
    • /
    • pp.23-31
    • /
    • 2016
  • Purpose: Recently energy consumption is rapidly increasing due to continuous development of social evolution in various field. In this situation, there is a lot of effort to reduce this energy consumption in many ways, especially in building energy. Preceding studies already started to analyze the housing area such as zero energy house and passive house by researching annual building energy consumption, but to apply the results of housing to office building is insufficient since it has different consumption tendency. Method: In this study, eQuest program was used for simulation and the base model is selected among standard office building in ASHRAE 90.1. Variables are divided into passive and active factors for comparison. Result: In passive factors, glazing system showed the highest energy saving rate by 21.3% with triple low-e glass and enhancing wall u-value showed the lowest energy saving rate by 3.6% with 0.15 m2/K. In active factors, VAV system showed 30.9% energy saving rate when compared to CAV system, and heat exchanger showed 10.2% energy saving rate. For regeneration energy part, photovoltaic panel generated 10.4% of base annual energy usage.

Observation of Water Consumption in Zn-air Secondary Batteries

  • Yang, Soyoung;Kim, Ketack
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권4호
    • /
    • pp.381-386
    • /
    • 2019
  • Zn-air battery uses oxygen from the air, and hence, air holes in it are kept open for cell operation. Therefore, loss of water by evaporation through the holes is inevitable. When the water is depleted, the battery ceases to operate. There are two water consumption routes in Zn-air batteries, namely, active path (electrolysis) and passive path (evaporation and corrosion). Water loss by the active path (electrolysis) is much faster than that by the passive path during the early stage of the cycles. The mass change by the active path slows after 10 h. In contrast, the passive path is largely constant, becoming the main mass loss path after 10 h. The active path contributes to two-thirds of the electrolyte consumption in 24 h of cell operation in 4.0 M KOH. Although water is an important component for the cell, water vapor does not influence the cell operation unless the water is nearly depleted. However, high oxygen concentration favors the discharge reaction at the cathode.