• Title/Summary/Keyword: Passive Tilt

Search Result 22, Processing Time 0.03 seconds

Ray backpropagation-based ship localization (음선 역전파 기반의 선박 위치 추정)

  • Cho, Seong-il;Byun, Gihoon;Byun, Sung-Hoon;Kim, J.S.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.4
    • /
    • pp.196-205
    • /
    • 2018
  • This paper presents an algorithm for passive localization of a ship by applying the ray back-propagation technique to the ship radiation noise data. The previous method [S. H. Abadi, D. Rouseff and D. R. Dowling, J. Acoust. Soc. Am. 131, 2599-2610 (2012)] estimates the position of a sound source in the near-field environment with no array tilt by using the RBD (Ray-based Blind Deconvolution) and ray back-propagation techniques. However, when there exists an array tilt, the above method leads to a large position estimation error. In order to overcome the problem, this study proposes an algorithm that estimates the position of a sound source by correcting the array tilt using the RBD and ray back-propagation techniques. The proposed algorithm was verified by using the ship noise of SAVEX15 (Shallow-water Acoustic Variability EXperiment in 2015) experimental data.

Changes of Minute Blood Flow in the Large Vessels during Orthostasis and Antiorthostasis, before and after Atropine Administration (체위변화가 두부 및 하지의 분시혈류량에 미치는 영향)

  • Park, Won-Kyun;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.19 no.2
    • /
    • pp.139-153
    • /
    • 1985
  • The passive tilt has been performed to study the orthostasis on the cardiovascular system. The orthostasis due to upright tilt was demonstrated as follows: the venous return, cardiac output and systemic arteiral blood pressure were decreased, whereas there was concomitant increase of heart rate, through the negative feedback mediated by such as the baroreceptor . Previous investigators have suggested that the tolerance to the orthostasis could he increased by blocking the cholinergic fiber with atropine which prevented vasodilation and bradycardia through the vasovagal reflex during the orthostasis. However, this hypothesis has not been clearly understood. This study was attempted to clarify the effect of atropine on the tolerance of the cardiovascular system to the upright and head-down tilt, and to investigate the change of the blood flow through head and lower leg with Electromagnetic flowmeter in both tilts before and after atropine state. Fourteen anesthetized dogs of $10{\sim}14kg$ were examined by tilting from supine position to $+77^{\circ}$ upright position (orthostasis), and then to $-90^{\circ}$ head-down position (antiorthostasis) for 10 minutes on each test. And the same course was taken 20 minutes after intravenous administration of 0.5mg atropine. The measurements were made of the blood flow(ml/min.) on the carotid artery, external jugular vein, femoral artery and femoral vein. At the same time pH, $PCO_2$, $PO_2$ and hematocrit (Hct) of the arterial and venous blood, and heart rate(HR) and respiratory rate (RR) were measured. The measurements obtained from upright and head-down tilt were compared with those from supine position. The results obtained are as follows: In upright tilt, the blood flow both on the artery and the vein through head and lower leg were decreased, however the decrement of blood flow through the head was greater than the lower leg And the atropine attenuated the decrement of the blood flow on the carotid artery, but not on the vessels of the lower leg. HR was moderately increased in upright tilt, but slightly in head-down tilt. The percent change of HR after the atropine administration was smaller than that before the atropine state in both upright and head-down tilts. Before the atropine state, RR was decreased in upright tilt, whereas increased in head-down tilt. However after the atropine state, the percent change of RR was smaller than that of before the atropine state in both upright and head-down tilts. In upright tilt, venous $PCO_2$ was increased, but arterial $PO_2$ and venous $PO_2$ were slightly decreased. Hct was increased in both upright and head-down tilts. The findings of blood $PCO_2$, $PO_2$ and Hct were not interferred by the atropine. In conclusion, 1;he administration of atropine is somewhat effective on improving the cardiovascular tolerance to postural changes. Thus, atropine attenuates the severe diminution of the blood flow to the head during orthostasis, and also reduces the changes of HR and RR in both orthostasis and antiorthostasis.

  • PDF

Circulatory and Respiratory Responses to Postural Changes (체위 변화에 수반되는 순환 및 호흡반응)

  • Chae, E-Up;Lee, Suck-Kang;Bae, Sung-Ho
    • The Korean Journal of Physiology
    • /
    • v.7 no.1
    • /
    • pp.13-21
    • /
    • 1973
  • An attempt was made to study circulatory and respiratory responses to the passive tilt. Anesthetized dogs were tilted from horizontal to upright $(+90^{\circ})$ and head down $(-90^{\circ})$ position. The arterial blood pressure was decreased in the upright position and was decreased slightly in the head down position comparing to that in the horizontal position. Cardiac index also decreased in the both upright and head down positions. The total systemic vascular resistance was slightly increased in the upright position and was markedly increased in the head down position. The mean pulmonary arterial pressure was significantly decreased in the both upright and head down positions. The total pulmonary vascular resistance was decreased in the both upright and head down positions. Oxygen consumption was slightly decreased in the upright position, whereas it was slightly increased in the head down position. The A-V $O_2$ difference (vol. %) was slightly increased in the upright position and increased in the head down position. From the above results, process of the circulatory compensation to the gravity in the Passive tilting test was discussed. Neuronal cardiovascular regulation to the gravity and tile adaptation of capacitance vessles to hydrostatic stress and oxygen consumption concerning anoxic endurance of the brain were also discussed.

  • PDF

Knee extension test for assessing hamstring flexibility (넓적다리뒤근육의 유연성 측정을 위한 무릎폄 검사)

  • Wootaek Lim
    • Journal of Korean Physical Therapy Science
    • /
    • v.30 no.1
    • /
    • pp.31-40
    • /
    • 2023
  • Hamstring flexibility is an important factor that affects muscle performance of the lower extremities and is closely associated with sports injuries. Therefore, evaluation of flexibility is important in clinical practice. Results of evaluation are determined by types of tests and cut-off values used; therefore, accurate and detailed understanding of these is necessary before examination. Although the straight leg raise and sit and reach tests are used to evaluate hamstring extensibility, structures including the nerves, fascia, and other muscles can significantly confound the results of these tests. The knee extension test is performed at 90° of hip flexion to minimize the posterior pelvic tilt that occurs during the straight leg test. The knee extension test is most recommended for selective evaluation of hamstring flexibility. The knee extension test is classified into active and passive tests. The cut-off value is usually set at 20° for the active and at 10° for the passive knee extension test. Although a strong association is observed between the two tests, the active knee extension test is preferred in clinical practice because it can be performed by a single examiner, which serves as an advantage. Age, sex, and warm-up exercise tend to affect flexibility; therefore, results should be interpreted with caution. Detailed understanding of each flexibility test is important for reliable evaluation.

Artificial Landmark Design and Recognition for Localization (위치추정을 위한 인공표식 설계 및 인식)

  • Kim, Si-Yong;Lee, Soo-Yong;Song, Jae-Bok
    • The Journal of Korea Robotics Society
    • /
    • v.3 no.2
    • /
    • pp.99-105
    • /
    • 2008
  • To achieve autonomous mobile robot navigation, accurate localization technique is the fundamental issue that should be addressed. In augmented reality, the position of a user is required for location-based services. This paper presents indoor localization using infrared reflective artificial landmarks. In order to minimize the disturbance to the user and to provide the ease of installation, the passive landmarks are used. The landmarks are made of coated film which reflects the infrared light efficiently. Infrared light is not visible, but the camera can capture the reflected infrared light. Once the artificial landmark is identified, the camera's relative position/orientation is estimated with respect to the landmark. In order to reduce the number of the required artificial landmarks for a given environment, the pan/tilt mechanism is developed together with the distortion correction algorithm.

  • PDF

Study on Effective Visual Surveillance System using Dual-mode(Fixed+Pan/Tilt/Zoom) Camera (듀얼 모드(고정형+PTZ 카메라) 감시 카메라를 이용한 효과적인 화상 감시 시스템에 관한 연구)

  • Kim, Gi-Seok;Lee, Saac;Park, Jong-Seop;Cho, Jae-Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.7
    • /
    • pp.650-657
    • /
    • 2012
  • An effective dual-mode camera system(a passive wide-angle camera and a pan-tilt-zoom camera) is proposed in order to improve the performance of visual surveillance. The fixed wide-angle camera is used to monitor large open areas, but the moving objects on the images are too small to view in detail. And, the PTZ camera is capable of increasing the monitoring area and enhancing the image quality by tracking and zooming in on a specific moving target. However, its FOV (Field of View) is limited when zooming in on a specific target. Therefore, the cooperation of wide-angle and PTZ cameras is complementary. In this paper, we propose an automatic initial set-up algorithm and coordinate transform method from the wide-angle camera coordinate to the PTZ one, which are necessary to achieve the cooperation. The automatic initial set-up algorithm is able to synchronize the views of two cameras. When a moving object appears on the image plane of a wide-angle camera after the initial set-up positioning, the obtained values of the wide-angle camera should be transformed to the PTZ values based on the coordinate transform method. We also develope the PTZ control method. Various in-door and out-door experiments show that the proposed dual-camera system is feasible for the effective visual surveillance.

A Therapeutic Approach Based on Motor Development in Congenital Muscular Torticollis: A Case Report (선천성 근육 사경 환아에 대한 운동 발달적 치료 접근: 증례보고)

  • Ryu, Je-Yong;Kim, Yu-Jin;Sung, Ju-Yeon;Shim, Jae-Hun;Lee, Gyu-Wan;Oh, Duck-Won
    • Physical Therapy Korea
    • /
    • v.13 no.2
    • /
    • pp.77-84
    • /
    • 2006
  • Although conservative management of congenital muscular torticollis (CMT) has been well documented, relatively little is known about the response to the treatment. The purposes of this case report were to describe the use of a therapeutic approach based on motor development in physical therapy intervention for an infant with CMT and to report the result of the treatment. The patient was a 20-day-old baby boy with left CMT presenting muscular mass in the left sternocleidomastoid muscle. The angle of the lateral head tilt was 20 degrees. The size of muscular mass was 5.3 mm in ultrasonography. Intervention included ultrasonic therapy, soft tissue massage, passive and active range of motion exercises, motor developmental therapy, and parent instruction. The procedures of motor developmental therapy and changes in the amount of lateral head tilt were documented using photography. The size of the mass was decreased to .3 mm before the 5-month follow-up. The patient also maintained a midline head position in the supine position and a midline head alignment during all functional activities. A therapeutic approach based on motor development is a beneficial method for reducing an asymmetrical head and neck position, and facilitating normal development as a component of physical therapy intervention.

  • PDF

Treatment of Congenital Muscular Torticollis with Unipolar Release (단극개방완화를 이용한 선천성 근육성 사경의 치료)

  • Park, Myong Chul;Song, Hyun Suk;Kim, Chee Sun;Yim, Shin Young;Park, Dong Ha;Pae, Nam Suk;Lee, Il Jae
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.38-45
    • /
    • 2009
  • Purpose: The congenital muscular torticollis is a neck deformity involving shortening of the sternocleidomastoid muscle, which is detected at birth or shortly after birth. This childhood disease is the third most common congenital musculoskeletal anomaly. The indication for surgery is a persistent head tilt with dificit of passive rotation and lateral bending of the neck and a tight band or tumor in the sternocleidomastoid muscle even after physical therapy. The purpose of this article is to report surgical outcomes with patients who had no or little response to physical therapy. Methods: Surgery was performed on 29 patients and their average age was 4.1 years (from 6 months to 20.1 years). The unipolar open release and partial myectomy were done in 28 cases and the muscle lengthening was done in 1 case. Physical therapy was started from postoperative seventh day. Follow - up period was ranged from 2 months to 5.4 years(mean follow - up, 20.4 months). Result: There were neither rotation nor lateral bending deficit after surgical treatment. Mild head tilt was noticed in 3 cases and residual bend was observed in 4 cases. The subjective assessments of surgical results by parents were excellent. Conclusion: Our surgical outcome encourages the surgical treatment of congenital muscular torticollis for patients who failed to respond to physical therapy.

A Study on the Natural Energy Effect about the Address No.0 of Eco-friendly Architecture (생태건축 0번지의 자연에너지 효과에 관한 연구)

  • Lee, Si-Woong;Kang, Byung-Ho;Lim, Sang-Hoon;Choi, Seung-Hee
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.19-25
    • /
    • 2003
  • The Address No.0 of Eco-friendly Architecture offers unique experience for those who visit the place to envisage the future architecture where nature, human and building exist in harmony. It is open to the general public including the students of elementary and secondary schools. This house has been built to provide opportunities for the general public to experience eco-friendly architecture. It's floor area is 42 pyung($140m^2$) and the overall site has the area of 180 pyung($600m^2$). The following illustrates some of its prominent features : ${\bullet}$ Remodeling of a traditional Korean residence ${\bullet}$ Application of passive solar systems ${\bullet}$ Use of clerestory windows and daylighting systems(washroom and machine room) ${\bullet}$ Operation of solar water heaters with flat plate collectors ${\bullet}$ Construction of Biotop(small ecological world) ${\bullet}$ Water circulation for Biotop by photovoltaic(150W) and wind power(400W) generation ${\bullet}$ Outdoor hot water supplied by all-glass evacuated solar tubes. Through this Address No.0 of Eco-friendly Architeture conclusions are as followings. 1. The array of tubes in collector has the best nice in that the number of tube is nine and the tilt angle is the latitude $+20^{\circ}$. 2. The thermal performance of the all-glass solar vacuum collector was excellent than of the flate-plate solar collector. 3. The adaption of new small wind power systems to buildings were proved to produce a profit if it is considered the expense of environment improvement and the wind speed increasing according to rise of building hight.

Multiple vertical depression-based HMS active target detection using GSFM pulse (GSFM 펄스를 이용한 다중 수직지향각 기반 선체고정소나 능동 표적 탐지)

  • Hong, Jungpyo;Cho, Chomgun;Kim, Geunhwan;Lee, Kyunkyung;Yoon, Kyungsik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.4
    • /
    • pp.237-245
    • /
    • 2020
  • In decades, active sonar, which transmits signals and detects incident signals reflected by underwater targets, has been significantly studied since passive sonar in Anti-Submarine Warfare (ASW) detection performance becomes lowered, as underwater threats become their radiated noise reduced. In general, active sonar using Hull-Mounted Sonar (HMS) adjusts vertical tilt (depression) and sequentially transmits multiple Linear Frequency Modulation (LFM) subpulses which have non-overlapped bands, i. e. 1 kHz ~ 2 kHz, 2 kHz ~ 3 kHz, in order to reduce shadow zones. Recently, however, Generalized SFM (GSFM), which is generalized form of SFM, is proposed, and it is confirmed that subpulses of GSFM have orthogonality among each other depending on setting of GSFM parameters. Hence, in this paper, we applied GSFM to active target detection using HMS to improve the performance by the signal processing gain obtained from enlarged bandwidths of GSFM subpulses compared to those of LFM subpulses. Through simulation, we verified that when the number of subpulses is three, the matched filter gain of GSFM is approximately 5 dB higher than that of LFM.