• 제목/요약/키워드: Passive Cooling Method

검색결과 36건 처리시간 0.022초

On Orbit Data Analysis About the Passive Cooling of MIRIS, a Compact Space Infrared Telescope

  • Lee, Duk-Hang;Moon, Bongkon;Jeong, Woong-Seob;Pyo, Jeonghyun;Lee, Chol;Kim, Son-Goo;Park, Youngsik;Lee, Dae-Hee;Park, Sung-Joon;Kim, Il-Joong;Park, Won-Kee;Seon, Kwang-Il;Nam, Uk-Won;Cha, Sang-Mok;Park, Kwijong;Park, Jang-Hyun;Yuk, In-Soo;Ree, Chang Hee;Jin, Ho;Yang, Sun Choel;Park, Hong-Young;Shin, Ku-Whan;Suh, Jeong-Ki;Rhee, Seung-Wu;Park, Jong-Oh;Lee, Hyung Mok;Matsumoto, Toshio;Han, Wonyong
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.50.1-50.1
    • /
    • 2014
  • The Multi-purpose InfraRed Imaging System (MIRIS) is the main payload of Science and Technology Satellite 3 (STSAT-3), which was launched onboard Dnepr rocket from Russian Yasny Launch Base in November 2013. The MIRIS is an infrared (IR) camera, and the telescope has to be cooled down to below 200K in order to reduce thermal background noise. For the effective cooling and low-power consumption, we applied passive cooling method to the thermal design of the MIRIS. We also conducted thermal analysis and tested for the passive cooling before the launch of STSAT-3. After the launch, we have received State-of-Health (SOH) data from the satellite on orbit, including temperature monitoring results. It is important that the temperature of the telescope was shown to be cooled down to below 200K. In this paper, we present both the temperature data of the MIRIS on orbit and the thermal analysis results in the laboratory. We also compare these results and discuss the verification of the passive cooling.

  • PDF

해풍(海風)을 이용한 하계(夏季) 도시열환경(都市熱環境)의 풍도(風道)계획과 인체의 쾌적성에 관한 연구 (Estimating the cooling effect of see breeze along canals and outdoor thermal comfort on urban heat load in summer)

  • 정창원;윤인;최영식
    • 한국산업융합학회 논문집
    • /
    • 제2권1호
    • /
    • pp.19-25
    • /
    • 1999
  • A new urban design method from the viewpoint of climate is considered to be desired for urban life. The authors verified on an environmental planning based on new urban design concept which introduced the effect of sea breeze blowing along canals. The field observation of urban thermal environment were carried out to examine the cooling effects of a river through city. The observations were conducted to find the effect of a sea breeze and climate in summer along canals. Effective distance from the sea and cooling effect of the sea breeze on urban temperature was analyzed. The thermal index using outdoor environment was modified with New Effective Temperature ET*. On the basis of the observation. Human thermal comfort is relieved and affected by sea breeze blowing along canals. The canals were utilized as the trail on which sea breeze blows towards the center of city. From these results, The wind trail is one of the effective passive design method from the viewpoint of urban climate.

  • PDF

비주거용 건물의 리모델링 계획 시 에너지 성능 향상을 위한 LT method의 적용 방법에 관한 연구 (An application of LT method for Design-decisions to improve energy performance of non-domestic buildings during the early stage of Remodeling Process)

  • 이승복;변소형
    • KIEAE Journal
    • /
    • 제3권4호
    • /
    • pp.3-14
    • /
    • 2003
  • Remodeling for an aged building is emerging as a potential alternative towards the future of the building industry. It is a more effective method than the new construction in environmental friendly view. Most of remodeling were aimed at the improvement of the function of the deteriorated finishing materials. But, at the early stage of remodeling process, energy performance of a building can be improved by adopting passive design solutions such as daylighting and natural ventilation. The purpose of this study is to explain the passive design strategy in remodeling process and to suggest a application of LT method. LT method is an energy-design tool which responds to parameters available early in design development. It provides an output of annual primary energy for lighting, heating, cooling and ventilation in non-domestic buildings. LT method basically uses the concept of passive zone and non-passive zones and should be used to evaluate the energy performance of a number of options and to make comparisons. In this paper, the process of LT method is introduced and investigated an applicability in our office building.

Overview of separate effect and integral system tests on the passive containment cooling system of SMART100

  • Jin-Hwa Yang;Tae-Hwan Ahn;Hong Hyun Son;Jin Su Kwon;Hwang Bae;Hyun-Sik Park;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.1066-1080
    • /
    • 2024
  • SMART100 has a containment pressure and radioactivity suppression system (CPRSS) for passive containment cooling system (PCCS). This prevents overheating and over-pressurization of a containment through direct contact condensation in an in-containment refueling water storage tank (IRWST) and wall condensation in a CPRSS heat exchanger (CHX) in an emergency cool-down tank (ECT). The Korea Atomic Energy Research Institute (KAERI) constructed scaled-down test facilities, SISTA1 and SISTA2, for the thermal-hydraulic validation of the SMART100 CPRSS. Three separate effect tests were performed using SISTA1 to confirm the heat removal characteristics of SMART100 CPRSS. When the low mass flux steam with or without non-condensable gas is released into an IRWST, the conditions for mitigation of the chugging phenomenon were identified, and the physical variables were quantified by the 3D reconstruction method. The local behavior of the non-condensable gas was measured after condensation inside heat exchanger using a traverse system. Stratification of non-condensable gas occurred in large tank of the natural circulation loop. SISTA2 was used to simulate a small break loss-of-coolant accident (SBLCOA) transient. Since the test apparatus was a metal tank, compensations of initial heat transfer to the material and effect of heat loss during long-term operation were important for simulating cooling performance of SMART100 CPRSS. The pressure of SMART100 CPRSS was maintained below the design limit for 3 days even under sufficiently conservative conditions of an SBLOCA transient.

생체용 순수 Ti 주조체의 냉각방법에 따른 주조조직과 부식특성 및 경도에 관한 연구 (A study on microstructure, corrosion characteries and hardness of pure Ti according to cooling methods)

  • 김재도
    • 대한치과기공학회지
    • /
    • 제23권1호
    • /
    • pp.65-73
    • /
    • 2001
  • The purpose of this study was to investigate the microstucture and hardness, corrosion of pure Ti alloy, which is widely used as partial denture frame work these days, depending on the cooling method, followed by casting. The first group was bench cooling at room temperature($18^{\circ}C$), the second group was slowly cooled in the furnace from $700^{\circ}C$ to room temperature, and third. rapidly cooled in $0^{\circ}C$ water. The microstructure of each specimen observed by means of photomicrograph taken by electron microscope, in add to the physical characteristics of each specimen were obtained using the rockwell Hardnest Number. the characteristics of corrosion. The results were obtained as follows: 1. From Potentiodynamic plot. we conclude furnace-cooled specimen had the best stabiltity of passive film and that air-cooled specimen showed similar characteristics. The density of electric current of quenched specimen was the highest, which formed kind of unstable passive film. 2. Specimen cooled at room temperature (air cooling) had the highest value of hardness of 81.26HRB, specimen cooled at ice-water, $0^{\circ}C$, had the value of 78.42HRB, and specimen furnace-cooled at $700^{\circ}C$ had lowest value of 77.1HRB. 3. Quenching treated micro-structure formed martensite structure by and large. In case of air cooling, we could see $\alpha$-structure widmanstatten formed overall. In furnace cooling, widmanstatten structure and various shape $\alpha$-structures forming colony with direction were detected.

  • PDF

상변화 물질을 이용한 이동전화기의 냉각에 관한 연구 (A Study of Cooling of Mobile Phone Using PCM Module)

  • 이상진;정수진;김우승
    • 대한기계학회논문집B
    • /
    • 제29권11호
    • /
    • pp.1173-1181
    • /
    • 2005
  • The cooling effect of a mobile phone using PCM(Phase Change Material) module has been numerically investigated. A transient three-dimensional numerical analysis of heat and fluid flow with natural convection is performed in this study. Governing conservation equations for mass, momentum and energy are solved by an implicit finite volume method. An enthalpy-porosity technique has been used for modeling of the melting process. Two different ways of placing the PCM module are considered. One is to place a PCM module between the substrate and battery pack, and the other is to place a PCM module between MCM(multichip module) and battery pack. Three different types of PCMs are used to predict the performance of PCM. The results show that passive cooling with PCM can reduce the temperature rise and the effect of natural convection in PCM module considered in this study is negligible.

현대 건축공간에서 버네큘러 주거 냉방기법의 적용방법에 관한 연구 (A Study on the Application Method of Passive Cooling Technology in Contemporary Architecture)

  • 윤재영;허용석;허범팔
    • 한국실내디자인학회논문집
    • /
    • 제19권3호
    • /
    • pp.22-29
    • /
    • 2010
  • Recent days, transition to ecological thought is being accelerating by environmental impact with a sustainable development. This symptom is no exception in architecture area. So is vernacular design affecting on modern architecture in many ways in terms of economical aspect and eco-friendly environment as well. Natural energy like solar power, environment, and terrestrial heat that applied in vernacular architecture is also widely accepted in name of 'sustainable energy' of which a design applied with ventilation and airing of natural wind is very useful & pragmatic in terms of economical reason. Accordingly, this study examined a relation between vernacular architecture and natural wind and compared it with traditional type and its feature of ventilation & airing. Ventilation & airing applied in the past can be divided into three categories: methods by convection, natural element, and architectural type. All these methods gave some pleasant felling indoors when there were no artificial energies. Even in modern age, such a ventilation & airing is being used with traditional type in different variety of materials, and it will be developed with modern technology without any extra cost in terms of sustainable expansion, and opened for further researches.

전기구동 자동차용 리튬이온 배터리의 고효율 운전을 위한 냉방 및 난방 시스템 설계에 대한 이론적 접근법 (Theoretical approach on the heating and cooling system design for an effective operation of Li-ion batteries for electric vehicles)

  • 김대완;이무연
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.2545-2552
    • /
    • 2014
  • 본 연구에서는 전기구동 자동차에 동력원으로 사용되는 고전압 및 고용량 배터리의 고효율 운전을 위하여 배터리 열관리 시스템 기술을 소개하고 이론적 설계 방법에 소개하고 한다. 이를 위하여 전기구동 자동차의 배터리로 많이 사용되는 리튬이온 배터리의 고효율 운전을 위한 발열 모델링을 제시하였고, 열원의 종류에 따른 냉방 및 난방 시스템 설계를 에너지 평형식을 이용하여 부하를 계산하였다. 특히, 리튬이온 배터리의 발열 모델링을 이용하여 충전 및 방전 시 발열 반응열과 혹서기 및 혹한기시 배터리 작동의 최적 온도를 유지하기 위한 냉방과 난방 설계 기술을 제시하였다. 전기구동 자동차 종류에 따라 배터리 사용 비중이 다르기 때문에 효율적인 배터리 열관리를 위하여 계절별 및 작동 모드별 부하에 따른 배터리 열관리 기술을 제안하였다. 또한, 냉방 부하가 가장 큰 여름철 동일 조건에서 외부 공기 온도가 같다고 가정하면 냉방 능력은 수랭식 냉매 방법이 가장 크며 공랭식 방법이 가장 작게 나타난다.

온실의 열을 이용한 저에너지하우스의 패시브 난방 효과 분석 (An Analysis on Effects of Passive Heating of Low Energy House Using Heat in Greenhouse)

  • 유동완;이태구
    • KIEAE Journal
    • /
    • 제16권5호
    • /
    • pp.103-109
    • /
    • 2016
  • Purpose: In Korea, to reduce greenhouse gas emissions, energy performance standard of buildings is being reinforced with goals of Passive House until 2017 and Zero Energy House until 2025 in order to reduce emissions from buildings which constitute a quarter of greenhouse gas emissions. In order to achieve the target of Zero Energy House, it is certainly necessary to develop renewable energy that can replace cooling and heating energy occupying a significant amount of building energy consumption after increasing the energy performance firstly. Method: In this study, effects of heat in greenhouse heated by solar heating on indoor heating were analyzed by constructing a greenhouse in front of the Low Energy Building. Result: As a result, indoor temperature was increased by peak average $27.8^{\circ}C$, peak average $6.8^{\circ}C$ was increased from when heat in greenhouse has not been used for heating and indoor surface temperature was increased by average $5.1^{\circ}C$. It shows it can be possible to use heat in greenhouse for heating, if the heating effects can be same as this experimental result because Energy Saving-Type buildings such as Low Energy House or Passive House keep from 18 to $20^{\circ}C$ in winter. Therefore, even if energy supply is cut off by disasters and other reasons, cooling and heating can be possible for some time.

박막형 열전 소자를 이용한 Chip-on-Board(COB) 냉각 장치의 설계 (A Design of Thin Film Thermoelectric Cooler for Chip-on-Board(COB) Assembly)

  • 유정호;이현주;김남재;김시호
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1615-1620
    • /
    • 2010
  • A thin film thermoelectric cooler for COB direct assembly was proposed and the COB cooler structure was modeled by electrical equivalent circuit by using SPICE model of thermoelectric devices. The embedded cooler attached between the die chip and metal plate can offer the possibility of thin film active cooling for the COB direct assembly. We proposed a driving method of TEC by using pulse width modulation technique. The optimum power to the TEC is simulated by using a SPICE model of thermoelectric device and passive components representing thermal resistance and capacitance. The measured and simulated results offer the possibility of thin film active cooling for the COB direct assembly.