• Title/Summary/Keyword: Passage Area Ratio

Search Result 41, Processing Time 0.022 seconds

Numerical Analysis of Flow Characteristics within Blades for Design Parameters of Impulse Supersonic Turbine Blade (충동형 초음속 터빈 익렬의 설계 변수에 따른 익렬내 유동 특성에 관한 수치적 연구)

  • 신봉근;정수인;김귀순;이은석
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.2
    • /
    • pp.62-72
    • /
    • 2004
  • In this paper. firstly, numerical results were compared with experimental results to verify accuracy of the results. It is found that the numerical results show good agreements with experimental result. Next, computations about flow within blades for design parameters such as radius of the pressure and suction side's curvature and pitch-chord ratio have been performed. It is found that the flow and performance characteristics mainly depend on shocks occurred at the leading edge of blades and the end of nozzle and separations occurred inside the flow passage. And shock of nozzle and separations depend upon area of flow passage and shocks of blade are affected by the number of blades occupied by a nozzle.

Tip Gap Flow and Aerodynamic Loss Generation over a Cavity Squealer Tip with the Variation of Pressure-Side Opening Length in a Turbine Cascade (스퀼러팁의 압력면 개방길이 변화에 따른 터빈 익렬 팁간극 유동 특성 및 압력손실)

  • Cheon, Joo Hong;Lee, Sang Woo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.6
    • /
    • pp.5-10
    • /
    • 2012
  • The effect of pressure-side opening length on three-dimensional flow fields and aerodynamic losses downstream of a cavity squealer tip has been investigated in a turbine rotor cascade for the squealer rim height-to-chord ratio and tip gap height-tochord ratio of $h_{st}/c$ = 5.05% and h/c = 2.0% respectively. The opening length-to-camber ratio is changed to be $OL/c_c$ = 0.0, 0.1, 0.2, 0.3, 0.4, 0.5, and 0.7 The results show that longer OL leads not only to weaker secondary flow but also to lower aerodynamic loss in the tip leakage vortex region, while it significantly widens the area with high aerodynamic loss in the passage vortex region. The aerodynamic loss coefficient mass-averaged all over the measurement plane is kept almost constant for $0.0{\leq}OL/c_c{\leq}0.3$, whereas it increases rapidly for $OL/c_c$ > 0.3 in proportion to $OL/c_c$. There is little deterioration in flow turning with increasing $OL/c_c$.

A Study on Area Planning of Air Conditioning Room for Hospital Design Focused on System (체계중심병원설계를 위한 공조실 면적 계획에 관한 연구)

  • Kim, Eun Seok;Yang, Nae Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.4
    • /
    • pp.27-35
    • /
    • 2019
  • Purpose: As the improvement in quality of medical environment and the spatial consideration for the prevention of infection in the hospital have become increasingly important in the recent years, specific and practical planning for air conditioning room's area has become a major issue accordingly. However, the air conditioning room tends to be discussed focusing on technical factors such as air conditioning systems that are irrelevant to building plans, while discussions of most departments related to the medical functions have actively taken placed. Therefore, this study aims to investigate the factors influencing the planning for the air conditioning room area, and through subsequent analysis of the area of the air conditioning room, to propose a way to improve effective planning for the air conditioning room area. Methods: This study examines the case hospitals that fall into two types: each floor supply system and concentrated supply system, and compares and analyzes the air conditioning room area-related factors and the characteristics of changes in the interior of air conditioning room before and after remodeling through air conditioning floor plan of those case hospitals. Results: The air conditioning room can be classified into the net area of the functional space such as duct passages, and the public area such as aisle space, and of those the public area is an important factor in calculating the area of the air conditioning room. The public area of the air-conditioning room should not be planned considering only the spaces for mobile passage or maintenance activities, but should be planned taking into account internal changes such as expansion and replacement of equipment in the future from the beginning. Implications: When planning a medical facility, it is used as basic data for the planning of the air conditioning room area, which is a significant fixed factor in the initial setting.

Analytical Study for the Plan of Unit Household in National Housing Scale - Oriented on the cases of Korea housing corporation since 2005 ; Focused on analysing area (국민주택규모 단위세대 평면 분석 연구 - 2005년 이후 대한주택공사 사례를 면적분석 중심으로 -)

  • Lee, Jeong-Ho;Lee, Chan
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.1
    • /
    • pp.180-189
    • /
    • 2010
  • Since collective houses are started to be supplied, the housing market has been transformed from supplier to demander oriented, and various type with same area of unit households have been deigned and started to be distributed. It can be expected that such transfer phenomenon would be continuously sped-up, and unit household will be more subdivided and varied. Thus, we analysed and studied the planes with subject of unit households in national housing scale ($85m^2$) that is treated as supply standard and has biggest volume in construction by Korean housing corporation. The analysing method is investigating the area of each room within unit household, calculating their minimum, maximum, and average values, studying the efficiency of unit household plane according to the structure of each room by comparative analysis these values, and analysing changing matter by investigating any change of each room area. The analysing results of which are followings. At first, number of BAY on face is increasing. Second, allocation of each room has been vary. Third, area ratio among bedroom1, livingroom, diningroom/kitchen become similar. Fourth, the area of diningroom/kitchen become somewhat bigger. Fifth, the space for passage way is efficiently allocated. Sixth, service area is reduced, Seventh, stereotyped phenomenon Is appeared. Based on many studies so far, any improvements of unit householder in national housing scale are followings. First, in terms of forming style, unit householder in national housing scale is unfolded in various way though, the form of each room is not more than typical style. Second, it shows stereotyped phenomenon. Especially, bathroom 1, 2 show stereotyped feature in terms of their type and area across entire research years, also LDK allocation method is stereotyped, as well as stereotyped trend in bedroom 2, 3, allocation for 4 BAY type.

A Study of the Compound Choking Phenomenon in Gas Flows (기체유동에서 발생하는 복합초킹 현상에 관한 연구)

  • Lee, Jun-Hee;Baek, Seung-Cheol;Choi, Bo-Gyu;Kim, Heuy-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.1
    • /
    • pp.54-60
    • /
    • 2003
  • Compound choking frequently occurs at a minimum area of the flow passage, where two or more streams which have different stagnation properties are merged. This phenomenon is especially important in that the flow choking may not be given by Mach number, M=1 at the nozzle throat. In order to obtain a detailed understanding of the flow characteristics involved in the compound flow choking, the two-dimensional, compressible, Wavier-Stokes equations are solved using a fully implicit finite volume method and the predicted solutions are compared with the results of the one-dimensional theoretical analysis. Stagnation pressure and temperature of each stream are changed to investigate the effects on the compound choking. The results show that stagnation pressures of each stream affect Mach number and static pressure distributions downstream of the exit of the convergent nozzle. However, the flow characteristics of the compound choking are not significantly dependent on the total temperature ratio.

A Study on the Comparison of the Combustion Characteristics between a Small HSDI and an IDI Diesel Engine by Advanced One-zone Heat Release Analysis (개선된 단일영역 열발생량 계산법을 사용한 소형 HSDI와 IDI엔진의 연소특성 비교에 관한 연구)

  • Lee, Suk-Young;Jeong, Ku-Seop;Jeon, Chung-Hwan;Jang, Young-June
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.6
    • /
    • pp.46-53
    • /
    • 2004
  • Heat release analysis is a very important method for understanding the combustion phenomena inside an engine cylinder. In this study, one-zone heat release analysis was used with the measured cylinder pressures of a HSDI(high speed direct injection) and IDI(indirect injection) diesel engines, Those have benefits of simple equation, fast speed, reliability. The objective of the study is to compare the combustion characteristics between a HSDI and an IDI. The result shoes that the maximum heat release rate of a HSDI is higher than that of an IDI because of long ignition delay period. The heat release curve of an IDI is more linear than that of a HSDI, thus is similiar to that of a SI engine. The combustion efficiency of a HSDI is higher than that of an IDI because of the smaller heat transfer loss of a HSDI. There is a suggestion here that an IDI engine has broad heat transfer area which include two combustion chambers, the connection passage of combustion chambers, etc.

Theoretical Study on Heat Exchanger Performance of a Fin-tube Evaporator with Frost Growth in a $CO_2$ Refrigerator Truck (이산화탄소 냉매를 이용한 냉동탑차용 핀-관 증발기의 서리성장에 따른 열교환기 성능에 관한 해석적 연구)

  • Myung, Chi-Wook;Cho, Hong-Hyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.48-54
    • /
    • 2012
  • To analyze the cooling performance of fin-tube evaporator in the refrigerator truck using R744 according to frost growth, the analytical model of evaporator was developed under frost and non-frost conditions. The performance of fin-tube evaporator was investigated with frost thickness and indoor temperature. Besides, the performance of evaporator under frost condition was compared to that under non-frost condition. As a result, area of air passage and system performance were decreased as the frost thickness increased. The cooling capacity was reduced by 10%, 20%, 30% when the frost thickness was 0.7 mm, 1.1 mm, and 1.6 mm respectively. At these conditions, the block ratio was 31%, 48%, and 71%. In addition, the outlet quality of refrigerant was not over 1 when the frost thickness was 1.6 mm in spite of high indoor air temperature.

Performance Analysis of an Axial Flow Turbine Stage with Coolant Ejection from Stator Trailing Edge (정익 후연의 냉각유체분사를 포함한 축류터빈단의 성능해석)

  • Kim, Tong Seop;Kim, Jae Hwan;Ro, Sung Tack
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.7
    • /
    • pp.831-840
    • /
    • 1999
  • In this work, an aerothermodynamic calculation model for cooled axial flow turbine blades with trailing edge ejection is suggested and a mean line performance analysis of a turbine stage with nozzle cooling is carried out. A unique model regarding the interaction between coolant and main gas is proposed, while existing correlations are adopted to predict viscous loss and blade outflow angle. The interactions considered are the heat transfer from main gas to coolant and the temperature and pressure losses by the mixing of two streams due to the trailing edge coolant ejection. For a stator blade without ejection, trailing edge loss calculated by the trailing edge analysis is compared with that calculated by loss correlation. The effect of heat transfer effectiveness of coolant passage on the mixing loss is analyzed. For a model turbine stage with nozzle cooling, parametric analyses are carried out to investigate the effect of main design variables(coolant mass flow ratio, temperature and ejection area) on the stage performance.

Medical Treatment Service for the Housing Welfare of Elderly People- Laying stress on Aging in Place concept - (노인주거복지 향상을 위한 의료서비스 지원방안 연구 - Aging in Place 개념을 중심으로 -)

  • Lee, Joon-Min;Park, Nam-Hee;Shin, Hwa-Kyoung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.367-370
    • /
    • 2005
  • Offer of medical treatment service for recovery or preservation of physical spiritual function of elderly people by sudden population graying developing is essential. Therefore, according to increase of elderly's medical treatment demand, medical treatment service request is augmented. Number of medical treatment service utilization wishes to grope medical treatment service support way for elderly residing cloth elevation laying stress on elderly's Aging in Place in increase trend in this research. If decide, is as following : First, national hospital and public health center were concentrated most on Seoul and kyonggi, and there were many hospitals to south of a river nine, Songpagu, Seochogu, and public health center was expose that is one by one to each nine. Second, in the case of Seoul, elderly population ratio was expose that comparatively high Yeongdeungpo, Chongno, Yongsan, west passage nine is few hospital number relatively in elderly's residential area. Third, need that establish elderly full text clinic on part of general hospital or university hospital equipment. Fourth, must do so that can use access as is easy little more in local community to all elderly who need medical treatment service of visit nursing, visit medical examination and treatment etc.. that consist in present public health center.

  • PDF

Characteristics of Ship's Traffic Route in Yeosu·Gwangyang Port (여수·광양항 출입항로 통항 특성)

  • KIM, Dae-Jin
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.2
    • /
    • pp.539-549
    • /
    • 2016
  • This study analyzed ship's passing characteristics in relation with incoming and outgoing routes in Yeosu Gwangyang Port, and examined the risk factors and measures for safety management of marine traffic. The number of passing ships in Yeosu Gwangyang Port was about 60,000 ships annually based on 2014, and the tonnage rose 73% from 447,000 thousand tons in 2005 to 770,000 thousand tons in 2014. Actually, the number of large passing ships was revealed to enormously increase. As a result of marine traffic survey in Yeosu Gwangyang Port for three days in August 2015, daily average passing ships were 408 ships, and 77% of the total passing ships passed between 04:00 and 20:00. The chemical ships and general cargo ships took up the most at 58% of the total incoming and outgoing ships, followed by other work ships at 21%, tankers at 8%, fishing vessels at 7.5% and container ships at 5.5%. Concerning the size of passing ships, ships less than 1,000 tons accounted for 58.6% of the total passing ships. Ships of 1,000-5,000 tons were 20.1%, and those of 5,000-10,000 tons were 6.8%, and more than 10,000 tons were 14.4%. Especially, ships of 500 tons and less using mainly coastal passing routes took up 49% of the total passing ships. As for ship's passage ratio by route, Nakpo sea area where many routes meet accounted for 27.2%, specified area 49%, costal route 8%, specified area's incoming and outgoing sea area around Daedo 4.5%, and Dolsan coastal ara and Kumhodo sea area 8.5%. The number of ships standing by for anchoring in the six designated anchorages was 230 for three days. The standby rate for anchoring was 25% based on the specified area passing ships. In Nakpo sea area, where many routes meet, parallel passing and cross passing between ships occurred the most frequently. In the specified area, many cases, in which incoming and outgoing cargo ships at the starting and ending parts and incoming and outgoing work ships and fishing vessels at the coastal routes cross, took place. Consequently, the following measures are urgently needed: active passing management in the Nakpo sea area, where passing routes are complex, specified areas and costal traffic routes, the elimination of rocks in the route close to Myodo, an effort to improve routes including shallow depth area dredging, and rational safety management for small work ships frequently incoming and outgoing the passing routes of large ships, and fishing vessels operated in the sea areas around those passing routes.