• Title/Summary/Keyword: Particulate matter(TSP)

Search Result 53, Processing Time 0.026 seconds

Estimation of Source Contribution of Particulate Matter in Taegu Area using Factor Analysis (다변량 통계분석법을 이용한 대구지역 부유분진의 오염원 기여도 추정)

  • 최성우;송형도
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.1-8
    • /
    • 2000
  • The objective of this study was to identify the sources and to estimate the source contributions to the atmospheric TSP(total suspended particulate matter) and PM-10(particulate matter with aerodynamic diameters less than 10$\mu\textrm{m}$) concentration in Taegu area. A total of 84 samples was collected during the January to December 1999. TSP and PM-10 were collected on filters by portable air sampler, and heavy metals in TSP and PM-배 were analyzed by ICO(Inductively Coupled Plasma Spectrometery) after preliminary treatment. The results were follow as : First, annual average of TSP and PM-10 concentration was 123 and 69$\mu\textrm{g}$/㎥ respectively. The concentration of TSP and PM-10 were highest in winter season compared to other seasons. Second, the concentration of Al, Fe, Mn were higher in TSP than in PM-10, indicating that these heavy metals are generally associate with natural contributions. Third, metal combinations showed that a high correlation among concentrations of heavy metals were follows: As Al, Fe and Mn in TSP ; Ni, Cr, Cd and Pb in PM-10. Finally, Statistical analysis was performed using Principal Components Analysis(PCA) in order to find possible sources of the pollutants. The factor analysis was permitted to identify four major sources(soil/road dust resuspension, waste incineration, furl combustion, vehicular emission) in each fraction. These source accounted for at least 83, 85% of variance of TSP and PM-10 concentration in Taegu area.

  • PDF

Characteristic comparison of Andersen and total suspended particulate samplers in a particulate matter generation chamber (입자 발생 챔버를 이용한 Andersen과 총분진 시료채취기의 특성 비교)

  • Park, Ju-Myon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.3
    • /
    • pp.177-184
    • /
    • 2008
  • The purpose of this study was to compare the performance characteristics of Andersen and total suspended particulate (TSP) samplers in terms of particle size distribution (PSD) and mass sampling efficiency. In the present study, two Andersen and four TSP samplers were selected and tested to quantitatively estimate human exposure to fly ash representing industrial particulate matter (PM) in a carefully controlled chamber. The PSD characteristics, a mass median aerodynamic diameter and a geometric standard deviation, were found from the sampled PM of airborne samplers in the chamber. An Andersen sampler was compared with a TSP sampler quantified by a coulter counter multisizer, as a reference sampler, to describe the correlation of mass sampling efficiencies between two types of samplers. Overall results indicate that Andersen samplers overestimated small PM due to particle bounce phenomena between impaction stages. There was reasonably good correlation ($R^2$ = 0.89 and 0.91) between the mass sampling efficiencies of Andersen and TSP samplers during the two tests. However, the lower values of slope (0.71 and 0.72) in two tests showed that the Andersen sampler underestimated PM (> AD $10.1\;{\mu}m$) with sufficient inertia due to a relatively lower Andersen inlet velocity at 0.8 m/s comparing with the operating air velocity at 2.1 m/s in the sampling zone of a chamber.

Source Characteristics of Particulate Trace Metals in Daegu Area (대구지역 부유분진 중 미량금속성분의 발생원 특성연구)

  • 최성우;송형도
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.5
    • /
    • pp.469-476
    • /
    • 2000
  • This study was performed to understand the behavior and source characteristics of particulate trace metals in Daegu area. To do this, total of 84 samples had been collected from January to December 1999. TSP (total suspended particulate matter) and PM-10(particulate matter with aerodynamic diameters less 10${\mu}{\textrm}{m}$) were collected by filters on portable air sampler, and in TSP and PM-10 were analyzed by ICP(Inductively Coupled Plasma Spectrometer) after preliminary treatment. The results were follow as: first, annul means of TSP and PM-10 concentration were 123 and 69$\mu\textrm{g}$/㎤ respectively. The concentration of TSP adn PM-10 were highest in winter season compared to other seasons. Second, the concentration of Al, Fe, Mn were higher in TSP than in PM-10, indicating that these metals are generally associate with natural contributions. Third, a hierarchical clustering technique was used to group 9 metals. The results from the cluster analysis of TSP and PM-10 shows a similar clustering pattern : Fe, Al in a group and the rest of the metals such as Ni, Cr, As, Mn, Cd, Pb, Zn in the other group. One group of metal such as Fe, Al is associated with natural sources such as soil and dust. The other is closely related to urban anthropogenic sources such as fuel combustion, incineration, and refuse burning, Finally, using Al as a reference element, enrichment factors were used for identifying the major particulate contributors. The enrichment factors of Al. Fe<10 (standard value of enrichment factor) were considered to have a significant dust and soil source and termed nonenriched. Ni, Cr, As, Mn, Cd, Pb, Zn》10 is enriched and has a significant which is contributed by athropogenic sources.

  • PDF

Analysis of the Fine Particulate Matter Particle Size Fraction Emitted from Facilities Using Solid Refuse Fuel (고형연료제품 사용시설에서 배출되는 미세먼지 입경분율 분석)

  • You, Han-Jo;Jung, Yeon-Hoon;Kim, Jin-guil;Shin, Hyung-Soon;Lim, Yoon-Jung;Lee, Sang-Soo;Son, Hae-Jun;Lim, Sam-Hwa;Kim, Jong-Su
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.719-725
    • /
    • 2020
  • Objectives: With the growth of national interest in fine particulate matter, many complaints about pollutants emitted from air pollution emitting facilities have arisen in recent years. In particular, it is thought that a large volume of particulate pollutants are discharged from workplaces that use Solid Refuse Fuel (SRF). Therefore, particulate contaminants generated from SRF were measured and analyzed in this study in terms of respective particle sizes. Methods: In this study, particulate matter in exhaust gas was measured by applying US EPA method 201a using a cyclone. This method measures Filterable Particulate Matter (FPM), and does not consider the Condensable Particulate Matter (CPM) that forms particles in the atmosphere after being discharged as a gas in the exhaust gas. Results: The mass concentration of Total Suspended Particles (TSP) in the four SRF-using facilities was 1.16 to 11.21 mg/Sm3, indicating a very large concentration deviation of about 10 times. When the fuel input method was the continuous injection type, particulate matter larger than 10 ㎛ diameter showed the highest particle size fraction, followed by particulate matter smaller than 10 ㎛ and larger than 2.5 ㎛, and particulate matter of 2.5 ㎛ or less. Contrary to the continuous injection type, the batch injection type had the smallest particle size fraction of particulate matter larger than 10 ㎛. The overall particulate matter decreased as the operating load factor decreased from 100% to 60% at the batch input type D plant. In addition, as incomplete combustion significantly decreased, the particle size fraction also changed significantly. Both TSP and heavy metals (six items) satisfied the emissions standards. The measured value of the emission factor was 38-99% smaller than the existing emissions factor. Conclusions: In the batch injection facility, the particulate matter decreased as the operating load factor decreased, as did the particle size fraction of the particulate matter. These results will help the selection of effective methods such as reducing the operating load factor instead of adjusting the operating time during emergency reduction measures.

Trace Metals of Ambient TSP in Daegu Area (대구지역 총 부유분진중 중금속)

  • 이찬형
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.67-73
    • /
    • 2003
  • This study was carried out to characterize the behavior and sources of particulate trace metal in Daegu city. TSP (Total Suspended Particulate matter) was collected by filters on High Volume Air Sampler from the four areal (reference, residential, commercial, industrial area). The moult were analyzed by AAS after preliminary treatment. The average centration trend of trace metals contained in TSP was shown as follows : Fe > Cu > Pb > Mn > Ni > Cr > Cd. The trace metals showed the highest concentration in the industrial area. This study showed the seasonal variation of trace metals. Fe and Mn showed high concentration in spring, whereas Cr, Ni, Cd and Pb showed high concentration in winter. Also this study showed the regional variation of trace metals. The order of the average concentration of trace metals was : industrial > commercial > residential > reference area. Using Mn as a reference element, the enrichment factor analysis were used for identifying the trace element contributors. The enrichment factors of Cr, Fe < 10 were considered to have a significant dust and soil source and termed nonenriched. Pb, Cd, Cu >>10 were enriched and had a significant fraction which was contributed by anthropogenic sources.

Seasonal impact to air qualities in industrial areas of the Arabian Gulf region

  • Al-Taani, Ahmed A.;Howari, Fares M.;Nazzal, Yousef;Yousef, Ahmad
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.143-149
    • /
    • 2018
  • Air quality conditions and pollution status have been evaluated in the industrial area between Sharjah and Ajman border in UAE. Daily concentrations of $O_3$, CO, $NO_2$, $SO_2$, $PM_{2.5}$, $PM_{10}$, Total Volatile Organic Compounds (TVOC) and Total Suspended Particulate (TSP) have been monitored from Sept. 2015 to April 2016. The monthly average concentrations of $O_3$, CO, $NO_2$, $SO_2$, TVOC were within the UAE ambient air quality standards during the survey period. However, $PM_{10}$ and TSP levels exceeded the recommended limits in Sept. 2015, Oct. 2015 and March 2016. Temporal variations in air quality parameters showed highest levels in March 2016 for $PM_{2.5}$, $PM_{10}$, $NO_2$, TVOC and TSP, whereas $O_3$, $SO_2$ and CO showed relatively low values in this month. $PM_{2.5}$ levels in ambient air were above the EPA guideline of $35{\mu}g/m^3$ in all months. $PM_{2.5}$ was the critical ambient air pollutant with Index for Pollutant ($I_p$) values varying from 103-209, indicating Air Quality Index categories of unhealthy for sensitive groups (62.5%) to unhealthy (25%) to very unhealthy (12.5%). The $I_p$ average values of $PM_{2.5}$ decreased from Sept. 2015 to reach lowest value in Dec. 2015 before increasing gradually, peaking in March 2016. These results suggest the potential health risks associated with $PM_{2.5}$ is low in winter, where the prevailing meteorological conditions of lower temperatures, higher humidity, higher wind speed reduced particulate matter. The results revealed the industrial area is impacted by anthropogenic and natural sources of particulate matter.

Characteristics of Size Distribution and Fugitive Emissions of Particulate Matter in Foundries (주물사업장의 입자상물질 입경분포 및 비산배출 특성)

  • Park, Jeong-Ho;Jang, Min-Jae;Kim, Hyoung-Kab
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.1
    • /
    • pp.30-37
    • /
    • 2016
  • Objectives: This study was performed to measure and evaluate the concentration, size distribution and fugitive emission of particulate matter from process operations at foundries. Methods: Particle matter was collected from three foundries, and samples were also collected from a background site for calculating the fugitive emission concentration of the foundries. For the collection of the samples, a Nanosampler cascade impactor was used. Results: The concentration of TSP in the samples collected from the three foundries was $0.675{\sim}1.222mg/m^3$, $PM_{10}$ was $0.525{\sim}1.018mg/m^3$ and $PM_{2.5}$ was $0.192{\sim}0.615mg/m^3$. The mass size distribution was bimodal or monomodal with maximum peak at two stage(size $2.5{\sim}10{\mu}m$). The mass median aerodynamic diameter(MMAD) was $1.80{\sim}3.98{\mu}m$. The fugitive emission concentration of TSP varies in the range of 0.65 to $1.21mg/m^3$, which exceeds the emission standard of fugitive dust($0.5mg/m^3$). Conclusions: Particle concentration and size is an important industrial hygiene factor to protect foundry workers. Furthermore, the presence of high emission of particulate pollutants has a significant negative impact on the ambient air of the study area. Therefore, it is important to improve both the process and prevention facility in oder to reduce particulate pollutants in foundries.

밀폐된 공간에서 환기에 의한 ETS 성분 제거

  • 황건중;이문수;나도영
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.21 no.1
    • /
    • pp.102-108
    • /
    • 1999
  • This study was conducted to evaluate the ventilation to remove gases, vapor and particles of environmental tobacco smoke(ETS) in a closed room. The ventilation rate choosed were 0.445 ㎥/min, 0.528 ㎥/min, and 0.625 ㎥/min. ETS components measured were total suspended particle(TSP), ultraviolet particulate matter(UVPM), fluorescent particulate matter(FPM), solanesol, carbon dioxide($CO_2$), carbon monoxide(CO), nicotine, and 3-ethenylpyri-dine(3-EP). The concentration of ETS components measured rapidly decreased as increasing ventilation rate, but the removal efficiency by ventilation was different from each ETS compounds. The $CO_2$, and CO, gaseous components of ETS, were dominant components to be removed from the room by ventilation. The ventilation with 0.528 ㎥/min for 1 hr was enough to remove over 99% of those gaseous components. Nicotine and 3-EP needed the ventilation for 2 hrs to reduce over 95 % of those components. As the same ventilation rate, 99 % of TSP and solanesol concentration were removed from the room within 2 hrs, UVPM and FPM concentration decreased 90 %.

  • PDF

Comparison of Characteristics of Local Meteorological and Particulate Matter(TSP) on the Beopjusa Temple and Seonamsa Temple (법주사와 선암사의 국지 기상 및 미세먼지 특성 비교)

  • Kim, Myoung Nam;Lim, Bo A;Lee, Myeong Seong;Jeong, So Young
    • Journal of Conservation Science
    • /
    • v.33 no.4
    • /
    • pp.283-295
    • /
    • 2017
  • It is crucial to measure meteorological elements in relation to the biodeterioration of building cultural heritages. The Beopjusa and Seonamsa temples located respectively in Chungbuk and Jeonnam provinces, Korea, exhibit biological damage to the building cultural heritages and cause noticeable climatic differences. To compare biodeterioration environments of the abovementioned temples, 10 meteorological elements were observed, and particulate matter (TSP) was collected at each location. Furthermore, a correlation analysis was conducted between meteorological elements, and between meteorological elements and TSP. The local meteorology at Beopjusa temple characteristically showcased high total horizontal radiation, UV radiation, evaporation, wind speed, and TSP concentration, whereas, that at Seonamsa temple showcased high temperature, humidity, dew point temperature, air pressure, precipitation and number of days with precipitation. An elemental analysis of TSP revealed the presence of sae-salts at Seonamsa temple, and compared to that of Beopjusa temple, the monthly frequencies of biogenic aerosol and Fe-containing particles were higher. The correlation analysis showed that wind speed and humidity were major meteorological factors at Beopjusa and Seonamsa temples, respectively. Subsequently, the characteristics of the local meteorology at Seonamsa temple are expected to affect the biological damage of the building cultural heritages, which is favorable for the growth of various organisms.

Urinary 1-Hydroxypyrene and 2-Naphthol as a Biological Exposure Markers of Total Suspended Particulate in the General Population (일반 인구집단에 대한 대기중 총먼지의 생물학적 노출지표로서 요중 1-hydroxypyrene 및 2-naphthol의 유용성)

  • Kang, Jong-Won;Kim, Heon;Kang, Dae-Hee;Lee, Chul-Ho;Cho, Soo-Hun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.3
    • /
    • pp.306-312
    • /
    • 2000
  • Background : Polycyclic aromatic hydrocarbons (PAH) are well known environmental pollutants. The measurement of PAH in ambient air is not commonly used, because it is quite difficult to perform and is unreliable. Using biomarkers of PAH can be an alternative approach to this problem. The PAH in ambient air is absorbed in particulate matter. Total suspended particulate(TSP) or particulate matter of less than $10{\mu}m$ in diameter (PM10) can be easily measured. Therefore, TSP or PM10 can be used as a surrogate measurements of ambient air PAH. Objectives : We investigated whether the urinary concentration of two biomarkers of PAH, 1-hydroxypyrene (1-OHP) and 2-naphthol, could reflect the total suspended particulate in the general population. Methods : In order to exclude the effects of occupational exposure and smoking, first grade middle school students were included in this study. Four middle schools within a one kilometer boundary of ambient air monitoring stations were selected. Total suspended particulate was regarded as the marker of airborne PAH. Diet and smoking data were collected by self administered questionnaires, and spot urine samples were collected. Urinary 1-OHP and 2-naphthol were analyzed by high performance liquid chromatography. Results : The correlation between urinary 1-OHP, 2-naphthol and passive smoking was not statistically significant. The correlation between urinary 1-OHP and TSP indices was not statistically significant. The correlations between urinary 2-naphthol and TSP of two lag days, one lag day, and zero lag days were statistically significant. The statistical significance of two lag days was the strongest (p=0.001), one lag day was the next (p=0.0275), and zero lag days was the weakest (p=0.0349). Conclusion : Our results imply that the urinary concentration of 2-naphthol can be applied as a PAH exposure marker for the general population with low PAH exposure.

  • PDF