• 제목/요약/키워드: Particle removal

검색결과 752건 처리시간 0.032초

Monte Carlo 모델을 이용한 웨이퍼 상 오염입자의 세정효율 예측 (Prediction of particle removal efficiency of contaminant particles on wafer using Monte Carlo model)

  • 이승욱;이동근
    • 한국입자에어로졸학회지
    • /
    • 제20권3호
    • /
    • pp.103-114
    • /
    • 2024
  • Liquid-spray cleaning has recently been considered an eco-friendly cleaning method in the semiconductor industry because it efficiently cleans contaminated wafers without using any chemicals, relying instead on direct momentum transfer through dropwise impaction. Previous researches are mainly divided into two groups, such as modelling studies predicting the cleaning effect of single-droplet impact and experimental works for measuring particle removal efficiency (PRE) that essentially accompanies multiple droplet impacts. Here, we developed a Monte Carlo model to connect the single-droplet based model to the ensemble effect of multiple droplet impacts in real cleaning experiments, and thereby predict the PREs from the impaction conditions of droplets and the diameters of target particles. Additionally, we developed a two-fluid supersonic nozzle system, capable of spraying 10-60 ㎛ droplets under control of impact velocity, with aims to validate the model predictions of PREs for 15-130 nm contaminant particles on a Si wafer. We confirmed that the model predictions are in agreement with the experimental data within 7% and the cleaning time needs to be controlled for ensuring the efficient removal of particles.

DAF 공정을 이용한 축산폐수의 고형물 분리와 부상특성 (Solid Separation and Flotation Characteristics of Livestock Wastewater Using DAF Process)

  • 강병준;유승준;이세일;곽동희
    • 상하수도학회지
    • /
    • 제22권3호
    • /
    • pp.359-366
    • /
    • 2008
  • The series of experiments under the various conditions were carried out to evaluate the feasibility of dissolved air flotation (DAF) as an alternative of conventional gravity sedimentation (CGS) and to investigate the decrease of the loadings following to biological wastewater treatment processes in livestock wastewater system. On the basis of the experiment result between CGS and DAF processes, for the other water quality criteria as well as suspended solid the removal efficiency of DAF process was about 20~25 % better than CGS process on average. In addition, the particle removal efficiency of DAF process became higher in proportion as the increase of air to solid (A/S) ratio and the general wastewater treatment efficiency of DAF process was enough to meet the requirement of loading decrease to following biological process even at low A/S ratio range. Though DAF process is widely known as an solid separation unit, there was not the notable relationship between particle separation efficiency and several pollutant removal efficiencies like $COD_{Cr}$ and nutrients (T-N, T-P). Assume that the $COD_{Cr}$ was removed as the fraction of particle separation in this experiment, the removal efficiency of T-N and T-P were sensitive to removal efficiency of $COD_{Cr}$, especially.

The effect of process parameters on copper powder particle size and shape produced by electrolysis method

  • Boz, Mustafa;Hasheminiasari, Masood
    • Steel and Composite Structures
    • /
    • 제15권2호
    • /
    • pp.151-162
    • /
    • 2013
  • In this study, an electrolyzing device for the production of metal powders was designed and fabricated. The production of copper powders was performed using a variety of current densities, anode-cathode distances and power removal times. The effect of these parameters on powder particle size and shape was determined. Particle size was measured using a laser diffraction unit while the powder shape was determined by SEM. Experimental results show that an increase in current density leads to a decrease in powder particle size. In addition particle shape changed from globular dendritic to acicular dendritic with increasing the current density. Distance between the cathode and anode also showed a similar influence on powder particle size and shape. An increase in time of powder removal led to an increase in powder particle size, as the shape changed from acicular dendritic to globular dendritic.

Assessment of Air Flow Misalignment Effects on Fume Particle Removal in Optical Plastic Film Cutting Process

  • Kim, Kyoungjin;Park, Joong-Youn
    • 반도체디스플레이기술학회지
    • /
    • 제19권4호
    • /
    • pp.51-58
    • /
    • 2020
  • Many types of optical plastic films are essential in optoelectronics display unit fabrication and it is important to develop high precision laser cutting methods of optical films with extremely low level of film surface contamination by fume particles. This study investigates the effects of suction and blowing air motions with air flow misalignment in removing fume particles from laser cut line by employing random particle trajectory simulation and probabilistic particle generation model. The computational results show fume particle dispersion behaviors on optical film under suction and blowing air flow conditions. It is found that suction air flow motion is more advantageous to blowing air motion in reducing film surface contamination outside designated target margin from laser cut line. While air flow misalignment adversely affects particle dispersion in blowing air flows, its effects become much more complicated in suction air flows by showing different particle dispersion patterns around laser cut line. It is required to have more careful air flow alignment in fume particle removal under suction air flow conditions.

불산-오존-희석 암모니아수 세정에 의한 실리콘 웨이퍼 표면의 미세입자 제거 (Particle Removal on Silicon Wafer Surface by Ozone-HF-NH4OH Sequence)

  • 이건호;배소익
    • Korean Chemical Engineering Research
    • /
    • 제45권2호
    • /
    • pp.203-207
    • /
    • 2007
  • 불산과 오존 세정 시 실리콘 웨이퍼 표면의 미세입자를 효과적으로 제거할 수 있는 세정 방법에 대하여 연구하였다. 불산의 농도가 0.3 vol% 이상이 되어야 미세입자가 제거 되었으며, 초음파가 인가된 오존수를 사용 시 제거 효율은 증가되었다. 오존과 불산 세정 단계 이후에 추가로 극미량의(0.01 vol%) 희석 암모니아수 세정을 하면 미세입자가 99%이상 제거됨을 확인하였다. 이는 암모니아수에 의한 웨이퍼 표면의 미세 에칭 효과와 알칼리 영역에서의 재흡착 방지 효과가 동시에 작용함에 기인된다고 보인다. 한편, 불산-오존-희석 암모니아수 세정은 통상의 SC-1 세정과 비교할 때 표면 미세 거칠기가 개선되는 경향을 보였다. 불산-오존-희석 암모니아수 세정은 상온에서도 미세입자를 효과적으로 제거할 수 있는 세정 방법으로, 고온 공정 및 과다한 화학액을 사용하는 기존 습식세정의 대안으로서 기대된다.

집진효율 향상을 위한 미세 에어로졸 입자의 응축에 의한 성장 연구 (Condensational Growth of Fine Aerosol Particles to Increase Precipitation Efficiency)

  • 한상우;황정호
    • 대한기계학회논문집B
    • /
    • 제24권8호
    • /
    • pp.1069-1076
    • /
    • 2000
  • As the environmental problems grow, the regulation of the pollutants emitted from power plants increases. Most of the pollutants in particle phase are removed by particle removal facilities, but fine particles between 0.1 micron and I micron in diameter have a low removal efficiency compared to particles in other size ranges. Therefore the present concern has concentrated on the removal of those fine particles. The purpose of this study is to grow fine particles by condensation to the range larger than I micron. Theoretically the general dynamic equation is solved with an assumption that the particle size follows a log-normal distribution to calculate the temporal behavior of the size distribution. Experiments have been carried out to compare the results with the theoretical predictions. Particles grown by condensation are sampled by impactors and observed with SEM photographs.

Focused Ion Beam을 이용한 EUVL Mask Defect Isolation 및 Repair (EUVL Mask Defect Isolation and Repair using Focused Ion Beam)

  • 김석구;백운규;박재근
    • 반도체디스플레이기술학회지
    • /
    • 제3권2호
    • /
    • pp.5-9
    • /
    • 2004
  • Microcircuit fabrication requires precise control of impurities in tiny regions of the silicon. These regions must be interconnected to create components and VLSI circuits. The patterns to define such regions are created by lithographic processes. In order to image features smaller than 70 nm, it is necessary to employ non-optical technology (or next generation lithography: NGL). One such NGL is extreme ultra-violet lithography (EUVL). EUVL transmits the pattern on the wafer surface after reflecting ultra-violet through mask pattern. If particles exist on the blank mask, it can't transmit the accurate pattern on the wafer and decrease the reflectivity. It is important to care the blank mask. We removed the particles on the wafer using focused ion beam (FIB). During removal, FIB beam caused damage the multi layer mask and it decreased the reflectivity. The relationship between particle removal and reflectivity is examined: i) transmission electron microscope (TEM) observation after particle removal, ii) reflectivity simulation. It is found that the image mode of FIB is more effective for particle removal than spot and bar mode.

  • PDF

Evaluation of Particle Removal Efficiency during Jet Spray and Megasonic Cleaning for Aluminum Coated Wafers

  • Choi, Hoomi;Min, Jaewon;Kulkarni, Atul;Ahn, Youngki;Kim, Taesung
    • 반도체디스플레이기술학회지
    • /
    • 제11권3호
    • /
    • pp.7-11
    • /
    • 2012
  • Among various wet cleaning methods, megasonic and jet spray gained their popularity in single wafer cleaning process for the efficient removal of particulate contaminants from the wafer surface. In the present study, we evaluated these two cleaning methods for particle removal efficiency (PRE) and pattern damage on the aluminum layered wafer surface. Also the effect of $CO_2$ dissolved water in jet spray cleaning is assessed by measuring PRE. It is observed that the jet spray cleaning process is more effective in terms of PRE and pattern damage compared to megasonic cleaning and the mixing of $CO_2$ in the water during jet sprays further increases the PRE. We believe that the outcome of the present study is useful for the semiconductor cleaning process engineers and researchers.

여과초기에서의 탈착된 입자의 거동 (Role of Detached Particles During Initial Filtration Phase)

  • 김자겸
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.16-24
    • /
    • 2005
  • Mathematical model was developed to verify a sequential particle removal taking place in a granular media gravity filter. Consequential multi-layer filtration cycle model was applied to verify the fraction of filter effluent particles that are filter influent particles that were never removed as well as the fraction of filter effluent particles that were detached after deposition were performed through laboratory experiments. Three sizes of marker particles were injected ahead of the filter column as a pulse in the presence of four sizes of polystyrene particles that were used as a primary source of particles in the raw suspension to investigate particle attachment alone in contrast to net removal from attachment and detachment. Microscopic counting of filter effluent particles was assumed to reflect attachment. Experimental results indicated that particle detachment is significant beginning from the early phase of filtration. For each size of fluorescent microspheres at one filter depth, fluorescent microsphere removal increased with filter runtime to a maximum due to ripening. The detached fraction of effluent particles increased with particle size and filter depth. The presence of detached particles and the increasing fraction of detached particles in deeper bed were confirmed.

SO2 제거를 위한 유전체 장벽 방전 - 광촉매 복합 공정에서의 입자 형성과 성장 (Particle Formation and Growth in Dielectric Barrier Discharge - Photocatalysts Hybrid Process for SO2 Removal)

  • 나소노바 안나;김동주;김교선
    • 산업기술연구
    • /
    • 제30권A호
    • /
    • pp.127-132
    • /
    • 2010
  • We analyzed the effects of several process variables on the $SO_2$ removal and particle growth by the dielectric barrier discharge - photocatalysts hybrid process. In this process, $SO_2$ was converted into the ammonium sulfate ($(NH_4)_2SO_4$) particles. The size and crystallinity of ammonium sulfate particles were examined by using TEM and XRD analysis. The dielectric barrier discharge reactor consisted of two zones: the first is for plasma generation and the second is for ammonium sulfate particles formation and growth. The first zone of reactor was filled with glass beads as a dielectric material. To enhance $SO_2$ removal process, the $TiO_2$ photocatalysts were coated on glass beads by dip-coating method. As the voltage applied to the plasma reactor or the pulse frequency of applied voltage increases, the $SO_2$ removal efficiency increases. Also as the initial concentration of $SO_2$ decreases or as the residence time increases, the $SO_2$ removal efficiency increases. $(NH_4)_2SO_4$ particles continue to grow by particle coagulation and surface reaction, moving inside the reactor. Larger particles in site are produced according to the increase of residence time or $SO_2$ concentrations.

  • PDF