• 제목/요약/키워드: Particle measurement

검색결과 1,196건 처리시간 0.027초

TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109, HCT Particle Sensor 3030을 이용한 PM2.5 측정결과 비교 (Comparison Study of the TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109 and HCT Particle Sensor 3030 for PM2.5 measurement)

  • 김두용;정혁;박재홍;현준호;황정호
    • 한국입자에어로졸학회지
    • /
    • 제8권1호
    • /
    • pp.9-15
    • /
    • 2012
  • Three different commercial particle counters were used to measure the PM2.5 particles in this study. An Aerosol Spectrometer (AS) 1.109 model of Grimm and a Particle Sensor (PS) 3030 model of HCT were compared with an Aerodynamic Particle Sizer (APS) 3321 model of TSI. The responses of these instruments were compared for four sizes ($1.0{\mu}m$, $1.5{\mu}m$, $2.0{\mu}m$ and $2.5{\mu}m$) of polystyrene latex (PSL) particles and indoor air particles of the office room. The mode diameter, particle size distribution and total particle number concentration of PSL particles were measured by each instrument. In the office room, the total particle number concentration was measured for 25 minutes. In results of particle size distribution and mode diameter, the APS 3321 (52 size-channels) was more accurate than the AS 1.109 (31 size-channels) and PS-3030 (10-szie channels) since the APS has more number of size-channels than the other instruments. However, AS 1.109 and PS-3030 provided similar results of total particle number concentration to those from the APS 3321. In results of office room test, there were no significant difference from each instrument similar to results of PSL test.

상압에서 열분해법을 이용한 실리콘 입자 제조 (Formation of Silicon Particles Using $SiH_4$ pyrolysis at atmospheric pressure)

  • 우대광;남경탁;김영길;김광수;강윤호;김태성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.126-129
    • /
    • 2007
  • The particle formation using pyrolysis has many advantages over other particle manufacturing techniques. The particles by pyrolysis have relatively uniform size and chemical composition. Also, we can easily produce high purity particles. Thus, we studied the formation of silicon particles by pyrolysis of 50% $SiH_4$ gas diluted in Ar gas. A pyrolysis furnace was used for the thermal decomposition of $SiH_4$ gas at $800^{\circ}C$ and atmospheric pressure. The aerosol flow from furnace is separated into two ways. The one is to the Scanning Mobility Particle Sizer (SMPS) for particle size distribution measurement and the other is to the particle deposition system. The produced silicon particles are deposited on the wafer in the deposition chamber. SEM measurement was used to compare the particle size distribution results from the SMPS. Depending on the experimental conditions, particles of high concentration in the $30\sim80$ nm size range were generated.

  • PDF

Measurement of the excited Xe atoms density of matastable state$(1S_5)$ under various binary gas mixtures(Ne-Xe) by Laser Absorption Spectroscopy.

  • Lee, Jun-Ho;OH, P.Y.;Moon, M.W.;Ko, B.D.;Jeong, J.M.;Lee, H.J.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1218-1220
    • /
    • 2005
  • We have developed laser absorption spectroscopy system for the measurement of excited Xe atoms in micro-discharged AC-PDP plasma. In this study, we have measured the absorption signals for the $1S_5$ xenon metastable state in the PDP cell with the various gas mixtures of Ne-Xe(1%), Ne-Xe(4%) and Ne-Xe(10%) under fixed gas pressure of 350 Torr and the eletrode gap distance of 50um. It is found that the maximum excited xenon densities are $1.2^{\ast}10^{12}\;cm^{-3}$, $1.8^{\ast}10^{12}\;cm^{-3}$ and $2.7^{\ast}10^{12}cm^{-3}$ for gas mixtures of Ne-Xe(1%), Ne-Xe(4%) and Ne-Xe(10%) respectively, in this experiment.

  • PDF

Characteristics of Nano-Particles Exhausted from Diesel Passenger Vehicle with DPF

  • Park, Yong-Hee;Shin, Dae-Yewn
    • 한국환경보건학회지
    • /
    • 제32권6호
    • /
    • pp.533-538
    • /
    • 2006
  • The nano-particles are known to influence the environmental protection and human health. The relationships between transient vehicle operation and nano-particle emissions are not well-known, especially for diesel passenger vehicles with DPF(Diesel Particulate Filter). In this study, two diesel passenger vehicles were measured on a chassis dynamometer test bench. The particulate matter (PM) emission of these vehicles was investigated by number and mass measurement. The mass of the total PM was evaluated using the standard gravimetric measurement method, and the total number concentrations were measured on a ECE15+EUDC driving cycle using Condensation Particle Counter (CPC). According to the investigation results, total number concentration was $1.14{\times}10^{11}$M and mass concentration was 0.71mg/km. About 99% of total number concentration was emitted during the $0{\sim}400s$ because of engine cold condition. In high temperature and high speed duration, the particulate matter was increased but particle concentration was emitted not yet except initial engine cold condition According to DPF performance deterioration, the particulate matter was emitted 2 times and particle concentration was emitted 32 times. Thus DPF performance deterioration affects particle concentration more than PM.

입자가 포함된 유동장에서 유체속도와 입자속도의 동시 측정기법 (Simultaneous Measurement of Fluid Velocity and Particle Velocity in a Particle-Containing Fluid Flow)

  • 김동욱;이대영;이윤표
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.355-363
    • /
    • 2005
  • A novel method for simultaneously measuring the fluid velocity and the large particle velocity in a particle-containing fluid flow is developed in this study. In this method, the fluid velocity and the large particle velocity are measured by PIV and PTV, respectively. The PIV and PTV images are obtained from the same flow images. Since a PIV result represents the average displacement of all particles in an interrogation area, it will include an error caused by the relative displacement between the large particles and the fluid. In order to reduce the false influence of large particles on the PIV calculation, the mean brightness of small PIV particle images is substituted to the locations of large particles in the PIV images. The simulation results showed that the new method significantly reduces the PIV error caused by the large particles even at the case where the large particles occupy area fraction as large as $20\%$ of the full image.

Abdominal-Deformation Measurement for a Shape-Flexible Mannequin Using the 3D Digital Image Correlation

  • Liu, Huan;Hao, Kuangrong;Ding, Yongsheng
    • Journal of Computing Science and Engineering
    • /
    • 제11권3호
    • /
    • pp.79-91
    • /
    • 2017
  • In this paper, the abdominal-deformation measurement scheme is conducted on a shape-flexible mannequin using the DIC technique in a stereo-vision system. Firstly, during the integer-pixel displacement search, a novel fractal dimension based on an adaptive-ellipse subset area is developed to track an integer pixel between the reference and deformed images. Secondly, at the subpixel registration, a new mutual-learning adaptive particle swarm optimization (MLADPSO) algorithm is employed to locate the subpixel precisely. Dynamic adjustments of the particle flight velocities that are according to the deformation extent of each interest point are utilized for enhancing the accuracy of the subpixel registration. A test is performed on the abdominal-deformation measurement of the shape-flexible mannequin. The experiment results indicate that under the guarantee of its measurement accuracy without the cause of any loss, the time-consumption of the proposed scheme is significantly more efficient than that of the conventional method, particularly in the case of a large number of interest points.

Ultrafine Particle의 독성, 측정방법 및 관리 (Ultrafine Particle Toxicities, Current Measurement Techniques and Controls)

  • 이수길;김성수
    • 한국산업보건학회지
    • /
    • 제20권3호
    • /
    • pp.203-215
    • /
    • 2010
  • This study is an overview of toxicities and measurement techniques of ultrafine particles (UFPs), and their exposure controls. UFPs are ubiquitous in many working situations. Exposure to UFPs is possibly causing adverse health symptoms including cardio-respiratory disease to humans. In order to measure exposure levels of airborne UFPs, there are current available measurement guidelines, instruments and other techniques (i.e. contour mapping, control banding). However, these risk assessment techniques including measurement techniques, controls and guidelines are dependent on background levels, metrics (e.g. size, mass, number, surface area, composition), environmental conditions and controls. There are no standardized measurement methods available and no generic and specific occupational exposure standards for UFPs. It is thought that there needs to be more effort to develop Regulations and Exposure Standards for generic UFPs should be based on more exposure data, health surveys, toxicological data and epidemiological data. A carefully considered hierarchy of controls can also reduce the maximum amount of airborne UFPs being emitted from diverse sources in industries.

클러터가 존재하는 환경에서의 HPDA를 이용한 다중 표적 자동 탐지 및 추적 알고리듬 연구 (A Study of Automatic Multi-Target Detection and Tracking Algorithm using Highest Probability Data Association in a Cluttered Environment)

  • 김다솔;송택렬
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1826-1835
    • /
    • 2007
  • In this paper, we present a new approach for automatic detection and tracking for multiple targets. We combine a highest probability data association(HPDA) algorithm for target detection with a particle filter for multiple target tracking. The proposed approach evaluates the probabilities of one-to-one assignments of measurement-to-track and the measurement with the highest probability is selected to be target- originated, and the measurement is used for probabilistic weight update of particle filtering. The performance of the proposed algorithm for target tracking in clutter is compared with the existing clustering algorithm and the sequential monte carlo method for probability hypothesis density(SMC PHD) algorithm for multi-target detection and tracking. Computer simulation studies demonstrate that the HPDA algorithm is robust in performing automatic detection and tracking for multiple targets even though the environment is hostile in terms of high clutter density and low target detection probability.

영상 처리 기법에서 곡률을 이용한 입경 측정 알고리듬의 개발 (Development of Image Processing Algorithm Using Boundary Curvature Information in Particle Size Measurement)

  • 김유동;이상용;김상수
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1445-1450
    • /
    • 2002
  • In the present study, a new pattern recognition algorithm was proposed to size spray particles using the boundary curvature information. Conceptually, this algorithm has an advantage over the others because it can identify the particle size and shape simultaneously, and also can separate the overlapped particles more effectively. Curvature of a boundary was obtained from the change of the slopes of two neighboring segments at the corresponding part. The algorithm developed in this study was tested by using an artificially prepared image of a group of spherical particles which were either isolated or overlapped. Particle sizes obtained from the measured curvatures agreed well with the true values. By detecting abrupt changes of the curvature along the image boundary, the element particles could be separated out from their overlapped images successfully.

분무 유동의 입경 계측 기법에 관한 연구 (Measurement Technique of Particle Sizing in Spay Flow)

  • 양창조;김정환;오종환;김만응;이영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.534-539
    • /
    • 2005
  • Particle image analyzer for measuring droplet size has been developed. Image processing technique was used with relaxation method. The morphological method based on partial curvature information of pre-processed images was adopted for recognition and separation of overlapped particles. The measurement results show that the present method may be reliable for the analysis of the size and distribution of droplets produced by water mist spay flow.

  • PDF