• 제목/요약/키워드: Particle measurement

검색결과 1,196건 처리시간 0.024초

입자 홀로그래피에서 입자의 광축 방향 위치 특성에 관한 연구 (The Characteristics of the Particle Position Along an Optical Axis in Particle Holography)

  • 추연준;강보선
    • 대한기계학회논문집B
    • /
    • 제30권4호
    • /
    • pp.287-297
    • /
    • 2006
  • The Holographic Particle Velocimetry system can be a promising optical tool for the measurements of three dimensional particle velocities. One of inherent limitations of particle holography is the very long depth of field of particle images, which causes considerable difficulty in the determination of particle positions in the optical axis. In this study, we introduced three auto-focusing parameters corresponding to the size of particles, namely, Correlation Coefficient, Sharpness Index, and Depth Intensity to determine the focal plane of a particle along the optical axis. To investigate the suitability of the above parameters, the plane image of dot array screens containing different size of dots was recorded by diffused illumination holography and the positions of each dot in the optical axis were evaluated. In addition, the effect of particle position from the holographic film was examined by changing the distance of the screen from the holographic film. All measurement results verified that the evaluated positions using suggested auto-focusing parameters remain within acceptable range of errors. These research results may provide fundamental information for the development of the holographic velocimetry system based on the automatic image processing.

직접 광대전의 대전특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of Direct Photoelectric Charging)

  • 이창선;김용진;김상수
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.753-759
    • /
    • 2000
  • Photoelectric charging is a very efficient way of charging small particles. This method can be applied to combustion measurement, electrostatic precipitator, metal separation and control of micro-contamination. To understand the photoelectric charging mechanism, particle charging of silver by exposure to ultraviolet is investigated in this study. Average charges and charge distributions are measured at various conditions, using two differential mobility analyzers, a condensation nucleus counter, and an aerosol electrometer. The silver particles are generated in a spark discharge aerosol generator. After that process, the generated particles are charged in the photoelectric charger using low-pressure mercury lamp that emits ultraviolet having wavelength 253.7 nm. The results show that ultra-fine particles are highly charged by the photoelectric charging. The average charges linearly increase with increasing particle size and the charge distribution change with particle size. These results are discussed by comparison with previous experiments and proposed equations. It is assumed that the coefficient of electron emission probability is affected by initial charge. The results also show that the charge distribution of a particle is dependent on initial charge. Single changed particle, uncharged particle and neutralized particle are compared. The differences of charge distribution in each case increase with increasing particle size.

알루미나/산화아연/이산화티타늄 나노유체의 열전도율 측정 (Measurement of the Thermal Conductivity of Alumina/Zinc-Oxide/Titanium-Oxide Nanofluids)

  • 김상현;최선락;홍종간;김동식
    • 대한기계학회논문집B
    • /
    • 제29권9호
    • /
    • pp.1065-1073
    • /
    • 2005
  • The thermal conductivity of water- and ethylene glycol-based nanofluids containing alumina $(Al_2O_3)$, zinc oxide (ZnO) and titanium dioxide $(TiO_2)$ nanoparticles is measured by varying the particle diameter and volume fraction. The transient hot-wire method using an anodized tantalum wire for electrical insulation is employed for the measurement. The experimental results show that nanofluids have substantially higher thermal conductivities than those of the base fluid and the ratio of thermal conductivity enhancement increases linearly with the volume fraction. It has been found that the ratio of thermal conductivity enhancement increases with decreasing particle size but no empirical or theoretical correlation can explain the particle-size dependence of the thermal conductivity. This work provides, for the first time to our knowledge, a set of consistent experimental data over a wide range of nanofluid conditions and can therefore serve as a basis for developing theoretical models to predict thermal conduction phenomena in nanofluids.

The effect of particle size on the determinability of maize composition in reflection mode.

  • MVaradi, Maria;Turza, Sandor
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1129-1129
    • /
    • 2001
  • Maize, in Hungary, is the fodder-plant grown in the biggest quantity. It is not only used as a fodder but other products such as iso-sugar are made from it, too. The quality of the fodder and the produce is largely dependent on the composition of the supplied maize to the processing site. The examination of quality parameters besides conventional methods are investigated and measured by NIR spectroscopy on a routine basis. The investigated parameters are the following: water, total protein, starch and oil content. The accuracy and precision of determining these parameters we, apart from the wet chemical methods, influenced by sample preparation to a great extent. One of the main features of this is the sample particle size and its distribution across the sample. The uneven distribution of particle size negatively influences the measurement accuracy, decreases model robustness and prediction ability. With these in mind the aim of our experiment was to investigate the effect of particle size on the accuracy of maize composition determination using reflection measurement setup. In addition, we tested different spectrum transformations, which are suitable for canceling this effect. In our experiment 47 samples were analyzed with three different mesh sizes (1.5mm, 1.8mm and 2mm). The results of our findings are presented here.

  • PDF

Evaluation of Methods for Determination of Bulk Density of Eight Kinds of Forage under Air-dry and Wet Conditions

  • Sekine, J.;Kamel, Hossam E.M.;El-Seed, Abdel Nasir M.A. Fadel;Hishinuma, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제16권8호
    • /
    • pp.1126-1130
    • /
    • 2003
  • The conditions of measurement for the determination of bulk density were evaluated to assess the bulkiness of 8 kinds of forage. The bulkiness of the forages was determined with 4 different sizes of forage samples with 7 different pressure application under air-dry and wet conditions. The dry bulk density (DBD) curvilinearly regressed with the pressure applied. The particle size of the samples and kinds of forage used in the present study did not affect changes in values of DBD determined under pressures over $20g/cm^2$ up to $200g/cm^2$. The values of the wet bulk density (WBD) increased as an increment of particle size, but were not always regressed on the particle size of the 8 kinds of forage. The DBD determined on 8 mm particles showed a higher correlation coefficient with neutral detergent fiber (NDF) contents. The DBD may be a useful tool for the assessment of NDF in forage, when it is determined under condition of a pressure of $100g/cm^2$ or over with a particle size of 8 mm. The WBD may not be utilized for the direct measurement of the physical characteristics of forage, but may be required a thorough consideration on water solubility of forages. Further studies are needed to clarify the DBD contribution to the prediction of forage intake by ruminants.

Particle Image Velocimetry 기법을 이용한 CMP 공정의 Slurry유동 분석 (Velocity Measurements of Slurry Flows in CMP Process by Particle Image Velocimetry)

  • 김문기;윤영빈;고영호;홍창기;신상희
    • 한국정밀공학회지
    • /
    • 제23권5호
    • /
    • pp.59-67
    • /
    • 2006
  • Chemical Mechanical Polishing(CMP) in semiconductor production is characterized its output property by Removal Rate(RR) and Non-Uniformity(NU). Some previous works show that RR is determined by production of pressure and velocity and NU is also largely affected by velocity of flowfield during CMP. This study is about the direct measurement of velocity of slurry during CMP and whole flowfield upon the non-groove pad by Particle Image Velocimetry(PIV). Typical PIV system is modified adequately for inspecting CMP and slurry flowfield is measured by changing both pad rpm and carrier rpm. We performed measurement with giving some variation in the kinds of pad. The results show that the flowfield is majorly determined not by Carrier but by Pad in the case of non-groove pad.

광학적 입자계수기를 이용한 2004년 황사기간 인천지역 에어로졸 특성 (Characteristics of Incheon Aerosol during Asian Dust Period in 2004 using Optical Particle Counter (OPC))

  • 정창훈;조용성;이종태
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.565-575
    • /
    • 2005
  • The characteristics for the aerosol number distribution was studied during spring, 2004 in Incheon. Optical Particle Counter (OPC, HIAC/ROYCO 5230) was used in order to measure the number concentration of aerosol in the range of $0.3\~25{\mu}m.$. The obtained results were compared with $PM_{2.5}\;and\;PM_{10}$ data during Asian dust events. The results show that the size resolved aerosol number concentration from OPC measurement has a similar tendency with $PM_{10}\;and\;PM_{2.5}$ mass concentration. During Asian dust periods, the number concentrations in large particle $(CH5\~CH8)$ increase more than small particles which diameter is less than $2.23{\mu}m(CH5)$ and the same results were shown when $PM_{10}$ was compared with $PM_{2.5}$ data compared with non-dust days, Consequently, this study shows that size resolved aerosol number concentration from OPC measurement can be used as a useful tool in comparison of mass concentration data.

근적외선 반사도를 이용한 토양 유기물 함량 측정 (Measurement of Soil Organic Matter Using Near Infra-Red Reflectance)

  • 조성인;배영민;양희성;최상현
    • Journal of Biosystems Engineering
    • /
    • 제26권5호
    • /
    • pp.475-480
    • /
    • 2001
  • Sensing soil organic matter is crucial for precision farming and environment friendly agriculture. Near infra-red(NIR) was utilized to measure the soil organic matter. Multivariate calibration methods, including stepwise multiple linear regression(MLR), principal components recession(PCR) and partial least squares regression(PLS), were applied to soil spectral reflectance data to predict the organic matter content. The effect of soil particle size and water content was studied. The range of soil organic matter contents was from 0.5 to 11%. Near infrared (NIR) region from 700 to 2,500nm was applied. For uniform soil particle size, result had good correlation (R$\^$2/ = 0.984, standard error of prediction= 0.596). The effect of soil particle size could be eliminated with 1st order derivative of the NIR signal. However. moist soil had a little lower correlation. R$\^$2/ was 0.95 and standard error of prediction was 0.94% using the PLS method. The results showed the possibility of soil organic matter measurement using NIR reflectance on the field.

  • PDF

광산란 계측기의 미세먼지 측정 정확도 향상을 위한 수분제거 전처리 기술 개발 (Development of Drying Systems for Accurate Measurement of Particulate Matter by means of Optical Particle Measuring Instruments)

  • 강두수;오정은;이상열;신희준;봉하경;최주현;김대성
    • 한국입자에어로졸학회지
    • /
    • 제14권4호
    • /
    • pp.191-203
    • /
    • 2018
  • IIn this study, we have developed drying systems for reducing the error by humidity on measuring particulate matter (PM) in the ambient air with optical particle measuring instruments. Two types of drying systems were designed: drying systems using heating and dilution methods. In addition, 3 types of drying systems using a heating method were designed: Type A (1 hole), B (3 holes) and C (7 holes). After making them, the laboratory and field tests were carried out to evaluate the developed drying systems. As a result, it was shown that the PM concentrations obtained by PM monitoring devices with drying systems agree well with that of the reference devices. Therefore, it could be concluded that the drying systems can be applied to PM monitoring devices for real-time monitoring of the ambient aerosols.

공기중 미세입자 측정 데이터 분석 및 통계 유의차 분석 (Airborne Fine Particle Measurement Data Analysis and Statistical Significance Analysis)

  • 안성준;문석환
    • 반도체디스플레이기술학회지
    • /
    • 제22권1호
    • /
    • pp.1-5
    • /
    • 2023
  • Most of the production process is performed in a cleanroom in the case of facilities that produce semiconductor chips or display panels. Therefore, environmental management of cleanrooms is very important for product yield and quality control. Among them, airborne particles are a representative management item enough to be the standard for the actual cleanroom rating, and it is a part of the Fab or Facility monitoring system, and the sequential particle monitoring system is mainly used. However, this method has a problem in that measurement efficiency decreases as the length of the sampling tube increases. In addition, a statistically significant test of deterioration in efficiency has rarely been performed. Therefore, in this study, the statistically significant test between the number of particles measured by InSitu and the number of particles measured for each sampling tube ends(Remote). Through this, the efficiency degradation problem of the sequential particle monitoring system was confirmed by a statistical method.

  • PDF