• Title/Summary/Keyword: Particle matters

Search Result 161, Processing Time 0.027 seconds

Distribution Characteristics of Organic Matters and Heavy Metals in Surface Sediments of Samcheok Port (삼척항 표층퇴적물 내 유기물 및 중금속 분포 특성)

  • Shin, Woo-Seok;Kim, Young-Kee
    • Applied Chemistry for Engineering
    • /
    • v.31 no.5
    • /
    • pp.481-486
    • /
    • 2020
  • To evaluate geochemical characteristics of surface sediments in Samcheok Port, the distribution characteristics of particle sizes, organic matters and heavy metals were investigated. The sediments showed a mixed property of sand, silt, and clay, however fine-grains dominated at the inner port and coarse-grains dominated at the outer port. The organic (COD, TOC, and IL) contamination of the sediment at the inner port were higher than that of the outer port, and the concentrations of total nitrogen and total phosphorus at the inner port was higher than those of the outer port. Also, heavy metals contamination of surface sediments at the inner port was higher than those of the outer port (except for As). From the results of high organic matter concentrations and C/N ratio at the inner port, it is considered that the contamination of organic matters was mainly derived from the land. The correlation analysis among the particle size, chemical composition, and heavy metals resulted in high correlation between silt-clay and heavy metals, and between organic matters and heavy metals. The sequential extraction results of heavy metals showed the sum of exchangeable, carbonate, and oxide fractions of Ni, Zn, Cu, Pb, Cd, and As were 14.8, 49.8, 39.1, 32.2, 51.8 and 26.6%, respectively.

A Comparative Study on Ambient Air Quality Standards for Particulate Matters (입자상 오염물질의 대기환경기준에 관한 비교연구)

  • 허정숙;남보현;김동술
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.353-354
    • /
    • 1999
  • 입자상물질에 관한 초기연구는 TSP (Total Suspended Particle)에 집중되었으나, TSP만으로는 인체에 미치는 영향이나 시정악화 같은 현상을 정확하게 설명한 수 없었다. 보건학적 관점에서, PM10과 사망률사이에 강한 상관관계가 있는 것으로 조사된 바 있으며 (Pope et al, 1995), 특히 PM10 중에서 미세입자 (PM2.5미만)는 인체에 미치는 영향이 더욱 큰 것으로 알려지고 있다 (Joel et al., 1996). 이에 따라 입자상 물질의 규제 관리는 미세입자 측면에서 강화될 필요가 있다.(중략)

  • PDF

An Analysis of Characteristics of Particulate Matter Exhausted from Diesel Locomotive Engines (디젤기관차 엔진에서 배출되는 입자의 특성분석)

  • 박덕신;김태오;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.2
    • /
    • pp.133-143
    • /
    • 2003
  • Numerous evidence have been reported that fine particulate matters can play an important role in threatening human health. Recently concerns on fine particle pollution from various engines may require re-examination of particulate emission standards. The particles emitted by most diesel engines are mainly divided into their size ranges such as Dp< 50 nm and 50 nm< Dp< 1,000 nm. In this work, the number concentration and the size distribution of fine particles emitted from an exhaust manifold of a railroad diesel engine were measured under load test conditions using a scanning mobility particle sizer (SMPS). The fine particles observed were within the range of 7 to 304 nm under different load conditions with two different dilution ratios. The fine particles exhibited unique patterns showing bimodal shapes in size distribution.

A study on a development of a measurement technique for diffusion of oil spill in the ocean (디지털 화상처리에 의한 해양유출기름확산 계측기법개발에 관한 연구)

  • 이중우;김기철;강신영;도덕희
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1998.10a
    • /
    • pp.211-221
    • /
    • 1998
  • A digital image processing technique which is able to get the velocity vector distribution of a surface of the spilled oil in the ocean without contacting the flow itself. This technique is based upon the PIV(Particle Imaging Velocimetry) technique and its system mainly consists of a high sensitive camera, a CCD camera, an image grabber, and a host computer in which an image processing algorithm is adopted for velocity vector acquisition. For the acquisition of the advective velocity vector of floating matters on the ocean, a new multi-frame tracking algorithm is proposed, and for the acquisition of the diffusion velocity vector distribution of the spilt oil onto the water surface, a high sensitive gray-level cross-correlation algorithm is proposed.

  • PDF

A Study on a Development of a Measurement Technique for Diffusion of Oil Spill in the Ocean (디지털 화상처리에 의한 해양유출기름확산 계측기법개발에 관한 연구)

  • 이중우;강신영;도덕희;김기철
    • Journal of Korean Port Research
    • /
    • v.12 no.2
    • /
    • pp.291-302
    • /
    • 1998
  • A digital image processing technique which is able to be used for getting the velocity vector distribution of a surface of the spilt oil in the ocean without contacting the flow itself. This technique is based upon the PIV(Particle Imaging Velocimetry) technique and its system mainly consists of a high sensitive camera, a CCD camera, an image grabber, and a host computer in which an image processing algorithm is adopted for velocity vector acquisition. For the acquisition of the advective velocity vector of floating matters on the ocean, a new multi-frame tracking algorithm is proposed, and for the acquisition of the diffusion velocity vector distribution of the spilt oil onto the water surface, a high sensitive gray-level cross-correlation algorithm is proposed.

  • PDF

Concentration and Size Distribution of Atmospheric Particulate Matters, Chloride, Nitrate, and Sulfate Salts in Urban Air (都市大氣중 浮遊粒子狀物質, 鹽化物, 窒酸鹽 및 黃酸鹽의 濃度와 粒經分布)

  • Sohn, Dong-Hun;Heo, Moon-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.3
    • /
    • pp.27-33
    • /
    • 1986
  • Atmospheric particulate matter (A. P. M.) was collected and size-fractionated by an Andersen high-volume air sampler over 15 month period from Jan. 1985 to Feb. 1986 in Seoul. The concentration of chloride, nitrate and sulfate were extracted in an ultrasonic bath and were analyzed by ion chromatography. The annual arithmetical mean of A. P. M. was 128.54 $\mug/m^3$. The concentration of anions were 2.88 $\mug/m^3$ for chloride, 3.86$\mug/m^3$ for nitrate, and 25.44$\mug/m^3$ for sulfate. The content of A. P. M. was lowest in the particle size range 1.1 $\sim 3.3\mum$ and increased as the particle size increased or decreased. And the anions exhibited a seasonal variation in the isize distribution. The contents of anions were higher in winter than summer. Ther ratio of fine particles to the total particles defined by F/T for chloride, nitrate and sulfate. The F\ulcornerT of these anion generally decrease with increasing air temperature. This tendency was prevalent in the chloride and nitrate.

  • PDF

Physicochemical Characteristics of Particulate Matter Emitted from Aluminum Casting Process (알루미늄 주조과정에서 배출되는 입자상물질의 물리·화학적 특성)

  • Jeong-Min Suh;Jeong-Ho Park
    • Journal of Environmental Science International
    • /
    • v.33 no.5
    • /
    • pp.297-304
    • /
    • 2024
  • PM (Particulate Matters) was collected from a bag filter dust collector at an aluminum foundries, and its physicochemical properties were investigated using particle size analyzer and scanning electron microscopy with energy dispersive X-ray spectrometer (SEM/EDS). The median volume diameter of the particles passing through the pretreatment dust collector of the cyclone was approximately 10 ㎛. The cyclone pretreatment dust collector was shown to significantly reduce the throughput of large particles with a particle size of 100 ㎛ or more. The chemical composition of the particles showed a high Al content, and trace amounts of Mg, Si, and Zn were detected.

A Study on the Mixing of Pulverization Matters when the Contrast Medium is connected to the Automatic Injection Device using the Syringe Connector (Syringe Connector를 이용하여 조영제를 자동 주입장치에 연결 시 분쇄물 혼입에 관한 연구)

  • Kim, Hyeon ju;Kim, Ji eun;Han, Yu bean;Choi, Seung hyun;Kang, Yun ki;Jung, Yu jin;Jung, Min young;Lee, Hoo min
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.777-783
    • /
    • 2018
  • The purpose of this study was to investigate the degree of tearing of the rubber when the spike of the syringe connector was connected to the bottle of the contrast medium composed of the rubber compound type and to investigate the presence of the synthetic rubber due to tearing and grinding and the size of the pulverized product when the pulverized matters rubber was detected. As a result, in the case of tearing degree, the front side of the first contact with the end of the syringe connector was torn more than the back side by about $3.14{\pm}0.04mm$, and the pulverized matters was detected on average 7 to 15 on the 10 contrast mediums. The average particle size was measured to be about $7.89{\pm}0.31{\mu}m$. In addition, it is necessary to develop a micro_filter type automatic injection system for blocking off the pulverized matters as well as additional experiments through various experiments and analysis methods, and it is considered that interest of related organizations will be needed in preparation of fatal accidents when pulverized matters is introduced.

Characteristics of PM10 Measured by Different Light-Scattering Instruments in Public Transport Vehicles (광산란 측정장치에 따른 대중교통차량 미세먼지 측정 특성)

  • Kwon, Soon-Bark;Jeong, Wootae;Park, Duckshin
    • Particle and aerosol research
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • In this study, indoor $PM_{10}$ concentration was measured by different type of real-time instruments in public transport vehicles. Light-scattering method is widely used in measuring the size of particulate matters and there is two types of light-scattering methods; one is the nephelometer type which measures the light-scattering degree by aerosol cloud, the other is the spectrometer type which measures light-scattering degree by individual particle. We observed the variation of $PM_{10}$ in KTX, subway and express bus carriages by 1-minute resolution and found that there is similar tendency in pattern among 4 light-scattering devices but difference in absolute concentrations. By comparing gravimetric result in a subway cabin, the spectrometer type device, C, was chosen as a reference device. The conversion factors of nephelometer device A-1, A-2, and B were 1.666, 1.463 and 2.125 respectively.