• Title/Summary/Keyword: Particle mass concentration

Search Result 276, Processing Time 0.03 seconds

A Study on the Deposition Characteristics of Ultrafine SiO2 Particles by Temperature Control in Deposition Zone (증착 구간에서의 온도 제어에 따른 SiO2 초미립자의 증착 특성 고찰)

  • You, Soo-Jong;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • v.16
    • /
    • pp.157-168
    • /
    • 1996
  • The deposition characteristics of ultrafine $SiO_2$ particles were investigated in a tube furnace reactor theoretically and experimentally controlling tube wall temperature in deposition zone. The model equations such as mass and energy balance equations and aerosol dynamic equations inside reactor and deposition tube were solved to predict the particle growth and deposition. The particle size and deposition efficiencies of $SiO_2$ particles were calculated, changing the process conditions such as tube furnace setting temperature, total gas flow rate inlet $SiCl_4$ concentration and were compared with the experimental results.

  • PDF

Physicochemical Characteristics of Single Asian Dust Storm Particles

  • Ma, Chang-Jin;Mikio kasahara;Hwang, kyung-Chul;Park, Kum-Chan;Park, Seong-Boo;Lee, Jeong-Joo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.E
    • /
    • pp.29-38
    • /
    • 2000
  • For the detailed characterization of atmospheric aerosol, the analysis of single particle is highly valuable. In this study, to investigate the characteristics of single Asian dust storm particles, scanning electron microscope(SEM) coupled with and energy dispersive X-ray microanalyzer(EDX) and micro-PIXE were applied. Sampling was performed at Kyoto University located in Kyoto, Japan, in spring of 1999. Mass concentration during Asian dust storm events was higher roughly 3∼5 times than measured in the season of the highest concentration. Single particles were generally sharp-edged and irregular in shape and contained mostly crustal elements. Significant amount of S in coarse fraction was detected in individual particles. A large particles in coarse fraction existed as the mixture of soil components and S. A good agreement between the result of SEM-EDX analysis and that iof micro-PIXE analysis was obtained in this study.

  • PDF

A Case Study of Ionic Components in the Size-resolved Ambient Particles Collected Near the Volcanic Crater of Sakurajima, Japan

  • Ma, Chang-Jin;Kim, Ki-Hyun;Kang, Gong-Unn
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.72-79
    • /
    • 2010
  • In this study, the ionic composition of volcanogenically derived particles and their temporal and spatial distributions have been investigated to evaluate the impact of the volcanic eruption on the local ecosystem and residents. To this end, an intensive field study was conducted to measure the size-segregated particulate matters at the east part of Sakurajima in Japan. Fractionated sampling of particles into > $PM_{10}$, $PM_{10-2.5}$, and $PM_{2.5}$ was made by a multi nozzle cascade impactor (MCI). The concentration of various ions present in the size-resolved particles was determined by Ion chromatography. The time dependent 3-dimensional Volcanic Ash Forecast Transport And Dispersion (VAFTAD) model developed by the NOAA Air Resources Laboratory (ARL) indicated that the sampling site of this work was affected by the volcanic aerosol particles plume. The temporal distributions of sulfate and $PM_{2.5}$ during the field campaign were significantly variable with important contributions to particle mass concentration. The chlorine loss, suspected to be caused by acidic components of volcanic gases, occurred predominantly in fine particles smaller than $10\;{\mu}m$.

Hydrolytic Stability of Cured Urea-Melamine-Formaldehyde Resins Depending on Hydrolysis Conditions and Hardener Types

  • Park, Byung-Dae;Lee, Sang-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.672-681
    • /
    • 2015
  • As a part of abating the formaldehyde emission of amino resin-bonded wood-based composite panels, this study was conducted to investigate hydrolytic stability of urea-melamine-formaldehyde (UMF) resin depending on various hydrolysis conditions and hardener types. Commercial UMF resin was cured and ground into a powdered form, and then hydrolyzed with hydrochloric acid. After the acid hydrolysis, the concentration of liberated formaldehyde in the hydrolyzed solution and mass loss of the cured UMF resins were determined to compare their hydrolytic stability. The hydrolysis of cured UMF resin increased with an increase in the acid concentration, time, and temperature and with a decrease in the smaller particle size. An optimum hydrolysis condition for the cured UMF resins was determined as $50^{\circ}C$, 90 minutes, 1.0 M hydrochloric acid and $250{\mu}m$ particle size. Hydrolysis of the UMF resin cured with different hardener types showed different degrees of the hydrolytic stability of cured UMF resins with a descending order of aluminum sulfate, ammonium chloride, and ammonium sulfate. The hydrolytic stability also decreased as the addition level of ammonium chloride increased. These results indicated that hardener types and level also had an impact on the hydrolytic stability of cured UMF resins.

Comparison of Airborne Nanoparticle Concentrations between Carbon Nanotubes Growth Laboratories based on Containment of CVD (탄소나노튜브 성장 실험실에서 CVD 밀폐 여부에 따른 공기 중 나노입자 농도 비교)

  • Ha, Ju-Hyun;Shin, Yong-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.3
    • /
    • pp.184-191
    • /
    • 2010
  • Although the usage of nanomaterials including carbon nanotubes (CNTs) has increased in various fields, scientific researches on workers' exposures and controls of these materials are very limited. The purpose of this study was to compare the airborne nanoparticles concentrations from two university laboratories conducting experiments of CNTs growth based on containment of thermal chemical vapor deposition (CVD). Airborne nanoparticle concentrations in three metrics (surface area concentration, particle number concentration, and mass concentrations) were measured by task using three direct reading instruments. In a laboratory where CVD was not contained, the surface area concentration, number concentration and mass(PM$_1$) concentration of airborne nanoparticles were 1.5 to 3.5 times higher than those in the other laboratory where CVD was confined. The ratio of PM$_1$ concentration to total suspended particles(TSP) in the laboratory where CVD was not confined was about 4 times higher than that in the other laboratory. This indicates that CVD is a major source of airbone nanoparticles in the CNTs growth laboratories. In conclusion, researchers performing CNTs growth experiments in these laboratories were exposed to airborne nanoparticles levels higher than background levels, and their exposures in a laboratory with the unconfined CVD were higher than those in the other laboratory with the confined CVD. It is recommended that in the CNTs growth laboratories adequate controls including containment of CVD be implemented for minimizing researchers' exposures to airborne nanoparticles.

Analysis of Measuring Error for Particle Size Analysis by Laser Diffraction Spectrometer (입자크기분석을 위한 레이저회절 분광계의 측정오차 분석)

  • Ha, Sang-An;Son, Heui-Jeong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.713-722
    • /
    • 2000
  • This study analysed error of measurement and reproducibility for particle size analysis by the laser diffraction spectrometer. Laser diffraction spectrometers has become a very important method of particle size analysis. This measuring method has the advantage of simple operation, good reproducibility and rapid analysis. A feeding and dispersing system have been developed, which allows mass throughputs between 0.1~23 g/min in flowing air and 1.4~35% in flowing liquid. It has been used as a feeder unit for wet and dry particle size analysis from diffraction patterns. Relevant parameters, such as particle shape, particle size, dispersion, flow rate, concentration were analysed for measuring error. And system parameters of instruments for measurement of dynamic processes, eg, measuring time, focal plane, injection pressure drop and dispersion effect by the ultrasonic and mixing of preliminary treatment, were also discussed.

  • PDF

Aerosol Characteristics at Tokchok Island in the Yellow Sea (황해상 덕적도의 대기 에어로졸 특성)

  • 이승복;배귀남;김용표;진현철;윤용석;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.4
    • /
    • pp.305-316
    • /
    • 2002
  • Various air pollutants were measured at Tokchok Island in the Yellow Sea that is about 50 km distant from Incheon since April 1999. This study was undertaken to help understanding the level of air pollution and its distribution characteristics over the Yellow Sea. The geographical characteristics of the air pollution monitoring station and emission inventories of Tokchok Island are introduced. The mass concentrations and chemical compositions of TSP and P $M_{2.5}$ measured until March 2000 are discussed in this paper. The overall average mass concentrations are about 37.2 $\mu\textrm{g}$/㎥ for TSP and 18.7 $\mu\textrm{g}$/㎥ for P $M_{2.5}$ , respectively, which are similar to or a little lower than the values observed in other background sites at Kangwha and Taean. However, they are much lower than those observed at Qingdao in China. The low mass concentration and major anthropogenic ion concentrations in aerosols collected at Tokchok Island show that local sources are not dominant at Tokchok Island. The estimated average fractions of anthropogenic non-sea-salt sulfate to the total sulfate concentration of TSP and P $M_{2.5}$ are greater than 80% for both sizes. It hence suggests that the sulfate be mainly affected by anthropogenic sources. If we consider the average mass ratio of P $M_{2.5}$ to TSP, the mass fractions of anthropogenic species to P $M_{2.5}$ , and the molar ratio of nss S $O_4$$^{2-}$ to total N $O_{3-}$, it may be possible to infer that a part of anthropogenic species measured at Tokchok Island be transported from China. The characteristics of neutralization of nss S $O_4$$^{2-}$ and the particle size of major ions are also discussed.

Study on the Regional Deposition of Smoke Particles in Human Respiratory Tract under the Variation of Fire and Breathing Conditions (화재 및 호흡조건 변화에 따른 연기입자의 인체 호흡기 내 영역별 침착량 분석)

  • Goo, Jaehark
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.95-104
    • /
    • 2019
  • Smoke generated in a fire consists of gaseous substances and particulate matter, such as unburned carbon that adsorbed the gases. Human injury caused by inhalation of gaseous substances present in smoke is mostly short-term, whereas damage caused by inhalation of particulate matter is relatively a long-term phenomenon depending on the state of the gas-phase adsorption. The amount and location of the deposited smoke particles are important factors in estimating the damage caused to humans, which are affected by the breathing conditions as well as particle conditions, such as the size and concentration affected by the combustion conditions. In this study, in order to understand the characteristics of the deposition of smoke particles in the respiratory tract related to the study of human smoke inhalation injury, the number and mass concentration of smoke particles deposited in different areas of the respiratory tract for different fuel types, combustion conditions and breathing conditions were calculated. In addition, the amount of mass deposition of smoke in the respiratory tract for a certain period of inhalation was compared with the atmospheric standard of fine dust.

Aerosol Emission from Road by Livestock Transport Vehicle Movement (축산관련차량 이동에 따른 도로의 에어로졸 발생량 분석)

  • Seo, Il-Hwan;Lee, In-Bok;Hwang, Hyun-Seob;Bae, Yeon-Jeong;Bae, Seung-Jong;Moon, Oun-Kyung
    • Journal of Korean Society of Rural Planning
    • /
    • v.19 no.4
    • /
    • pp.137-147
    • /
    • 2013
  • Most of livestock houses are concentrated in certain area with mass rearing system resulting in rapid spread of infectious diseases such as HPAI (highly pathogenic avian influenza). The livestock-related vehicles which frequently travel between farms could be a major factor for disease spread by means of transmission of airborne aerosol including pathogens. This study was focused on the quantitative measurement of aerosol concentration by field experiment while vehicles were passing through the road. The TSP (total suspended particle) and PM10 (particle matter) were measured using air sampler with teflon filter installed downward the road with consideration of weather forecast and the direction of road. And aerosol spectrometer and video recorders were also used to measure the real-time distribution of aerosol concentration by its size. The results showed that PM2.5 was not considerable for transmission of airborne aerosol from the livestock-related vehicle. The mass generated from the road during the vehicle movement was measured and calculated to 241.4 ${\mu}g/m^3$ by means of the difference between TSP and PM2.5. The dispersion distance was predicted by 79.6 m from the trend curve.

A Study on the Tendency of Fugitive Dust for Environmental Maintenance at the Aggregate Unloading Site of Ready-mixed Concrete Plants (레미콘 플랜트의 골재하차장 환경 유지관리를 위한 비산먼지 발생 경향에 관한 연구)

  • Cho, Hyun-Woo;Shin, Hong-Chul;Chung, Yoon-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.103-111
    • /
    • 2022
  • Fine dust can cause serious problems to human health, and fugitive dust generated at construction sites is one of the main sources of fine dust in Korea. However, monitoring of the amount of fugitive dust generated at the ready-mixed concrete plant site is not performed, and only passive monitoring methods are partially applied in the field. Since it is impossible to control fugitive dust after it is exposed to the air, it is very important to suppress the occurrence or to remove it immediately at the stage of occurrence. Therefore, after identifying the characteristics through real-time monitoring in the fugitive dust generation stage, systematic management is required for suppressing or removing scattering dust in the field. In this study, the scattering dust generation characteristics were analyzed by measuring the particle mass concentration(PMC) of Fugitive dust generated at the aggregate unloading site of the ready-mixed concrete plant in real-time.