• 제목/요약/키워드: Particle mass concentration

검색결과 276건 처리시간 0.028초

실공간에서 공기정화시스템을 이용한 실내 오염 입자 제거 특성에 관한 연구 (A Study on the Removal Characteristics of Indoor Air Pollutants using the Air Cleaning System)

  • 구정환;김성찬;김장우;이주용;이재근;강태욱;이감규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.532-537
    • /
    • 2000
  • The purpose of this study is to determine the performance of a commercial air cleaner in removing tobacco smoke indoors. Following injection of tobacco smoke in a room, decay rates for particle concentrations were obtained far mass concentration at each point. The size distribution of the tobacco smoke particles was approximately $1.266{\mu}m$ in mass median diameter with a geometric standard deviation of 1.313. The air cleaner consisted of an electrostatic filtration unit and a fan operated at a flow rate of 5.98 CMM. The collection efficiency for $>1\;{\mu}m$ was more than 99%. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 30% of initial values within 30 minutes and with air cleaner operation, decreased to 90% of initial values in the test chamber, volume $51.27\;m^3$. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 10% of initial values within 30 minutes and with air cleaner operation, decreased to 30-70% of initial values in the test chamber, volume $149.2\;m^3$.

  • PDF

베타선 흡수법을 이용하는 미세먼지 측정시스템을 위한 잡음제거 방법 (Noise Reduction Method for Particle Measurement System using Beta-ray Absorption Method)

  • 최훈;손상욱;배현덕
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1706-1712
    • /
    • 2012
  • The Beta-ray absorption method (BAM) gives a good solution for measuring the mass concentration of atmospheric particles(PM10 and PM2.5). To determine particular matters (PM) concentration, a ratio of the number of detected beta-ray intensity passing through the clean filter and the dust-sampled filter is used. These intensity data measured in air pollution monitoring such as PM10 and PM2.5 usually contained the additive noise(thermal noise, power supply noise and etc.). Therefore, the estimation performance of mass concentration can be deteriorated by these noises. In this paper, we present a new noise reduction method that is essentially required to develope an automatic continuous PM monitoring system using beta-ray absorption method. By combining the block data averaging technique and curve fitting, in the proposed method, the additive noise can be reduced in the measured data. To evaluate the performance of the proposed method, computer simulations were performed with computer generated signals as the input.

Coconut husk as a biosorbent for methylene blue removal and its kinetics study

  • Dave, Shailesh R.;Dave, Vaishali A.;Tipre, Devayani R.
    • Advances in environmental research
    • /
    • 제1권3호
    • /
    • pp.223-236
    • /
    • 2012
  • Biosorption of methylene blue (MB) from aqueous solution was studied with respect to the point of zero charge of coconut husk, dye concentration, particle size, pH, temperature, as well as adsorbent and NaCl concentration using coconut husk biomass. Amongst Langmuir and Freundlich adsorption isotherms studied, Langmuir adsorption isotherm showed better agreement. Pseudo second order kinetics model was found to be more suitable for data presentation as compared to pseudo first order kinetics model. Also, involvement of diffusion process was studied using intraparticle diffusion, external mass transfer and Boyd kinetic model. Involvement of intraparticle diffusion model was found to be more relevant (prominent) as compared to external mass transfer (in) for methylene blue biosorption by the coconut husk. Moreover, thermodynamic properties of MB biosorption by coconut husk were studied. Desorption of methylene blue from biomass was studied with different desorbing agents, and the highest desorption achieved was as low as 7.18% with acetone, which indicate stable immobilization. Under the experimental conditions MB sorption was not significantly affected by pH, temperature and adsorbent concentration but low sorption was observed at higher NaCl concentrations.

부산 지역 연무 발생일의 미세먼지 중 금속과 이온 성분 농도 특성 (Characteristics of Metallic and Ionic Concentration in Fine Particle during Haze Days in Busan)

  • 전병일
    • 한국환경과학회지
    • /
    • 제26권6호
    • /
    • pp.767-778
    • /
    • 2017
  • This research investigates the characteristics of metallic and ionic elements in $PM_{10}$ and $PM_{2.5}$ on haze day and non-haze day in Busan. $PM_{10}$ concentration on haze day and non-haze day were 85.75 and $33.52{\mu}g/m^3$, respectively, and $PM_{2.5}$ on haze day and non-haze day were 68.24 and $23.86{\mu}g/m^3$, respectively. Contribution rate of total inorganic water-soluble ion to $PM_{10}$ mass on haze day and non haze day were 58.2% and 61.5%, respectively, and contribution rate of total water-soluble ion to $PM_{2.5}$ mass on haze day and non haze day were 58.7% and 64.7%, respectively. Also, contribution rate of secondary ion to $PM_{10}$ mass on haze day and non haze day were 52.1% and 47.5%, respectively, and contribution rate of secondary ion to $PM_{2.5}$ mass on haze day and non haze day were 54.4% and 53.6%, respectively. AC (anion equivalents)/CE (cation equivalents) ratio of $PM_{10}$ mass on haze day and non haze day were 1.09 and 1.0, respectively, and AC/CE ratios of $PM_{2.5}$ mass on haze day and non haze day were 1.12 and 1.04, respectively. Also, SOR (Sulfur Oxidation Ratio) of $PM_{10}$ mass on haze day and non haze day were 0.32 and 0.17, respectively, and SOR of $PM_{2.5}$ on haze day and non haze day were 0.30 and 0.15, respectively. Lastly, NOR (Nitrogen Oxidation Ratio) of $PM_{10}$ on haze day and non haze day were 0.17 and 0.08, respectively, and NOR of $PM_{2.5}$ on haze day and non haze day were 0.13 and 0.06, respectively.

사후관리단계에 있는 매립지의 건식침적량 및 토양오염에 관한 연구 -난지도 매립지 사례를 중심으로- (A Study on the Atmospheric Dry Deposition Flux and Soil Contamination in a Completed Landfill - A case study on Nanji landfill -)

  • 이승묵;조경숙;이은영;김윤정;박재우;박석순
    • 환경영향평가
    • /
    • 제8권2호
    • /
    • pp.31-44
    • /
    • 1999
  • Atmospheric dry deposition flux and ambient particle mass size distribution were measured to evaluate the impact of atmospheric deposition around the Nanjido landfill sites. Wind direction affects greatly on the variation of mass flux and mass size distribution and made two times higher when the wind was blown from the road side. The effect of Nanjido landfill on the mass size distribution was significant comparing to simultaneously measured mass size distribution at the other sampling site. The results showed that the particle diameter bigger than $10{\mu}m$ explained the majority of atmospheric dry deposition flux. A survey was also carried out to investigate the contamination of soils in a completed Nanjido landfill. The chemical properties of the soil analyzed in the present study include pH, oxidation-reduction potential (ORP), anion and cation concentration, total organic carbon(TOC), and some-metal elements concentrations were analyzed. Microbial activity in the soils was also evaluated by measuring dehydrogenase activities. TOC in the soil contaminated with leachate was $467.0{\mu}g/g-dry$ soil, and the TOC in the soil, where Nanjido landfill gases were emitted from, was $675{\mu}g/g-dry$ soil. The highest microbial activity of $968.0{\sim}2147{\mu}g-TPF/g-dry$ soil day was found in the soil spouting Nanjido landfill gases. Compared with those in the uncontaminated soil, the concentrations of Cr, Cu and Ph in the contaminated soil were higher.

  • PDF

Effects of Spray Surfactant and Particle Charge on Respirable Coal Dust Capture

  • Tessum, Mei W.;Raynor, Peter C.
    • Safety and Health at Work
    • /
    • 제8권3호
    • /
    • pp.296-305
    • /
    • 2017
  • Background: Surfactant-containing water sprays are commonly used in coal mines to collect dust. This study investigates the dust collection performance of different surfactant types for a range of coal dust particle sizes and charges. Methods: Bituminous coal dust aerosol was generated in a wind tunnel. The charge of the aerosol was either left unaltered, charge-neutralized with a neutralizer, or positively- or negatively-charged using a diffusion charger after the particles were neutralized. An anionic, cationic, or nonionic surfactant spray or a plain water spray was used to remove the particles from the air flow. Some particles were captured while passing through spray section, whereas remaining particles were charge-separated using an electrostatic classifier. Particle size and concentration of the charge-separated particles were measured using an aerodynamic particle sizer. Measurements were made with the spray on and off to calculate overall collection efficiencies (integrated across all charge levels) and efficiencies of particles with specific charge levels. Results: The diameter of the tested coal dust aerosol was $0.89{\mu}m{\pm}1.45$ [geometric $mean{\pm}geometric$ standard deviations (SD)]. Respirable particle mass was collected with $75.5{\pm}5.9%$ ($mean{\pm}SD$) efficiency overall. Collection efficiency was correlated with particle size. Surfactant type significantly impacted collection efficiency: charged particle collection by nonionic surfactant sprays was greater than or equal to collection by other sprays, especially for weakly-charged aerosols. Particle charge strength was significantly correlated with collection efficiency. Conclusion: Surfactant type affects charged particle spray collection efficiency. Nonionic surfactant sprays performed well in coal dust capture in many of the tested conditions.

PIXE 분석에 의한 대기에어로졸의 원소분석 -표준시료의 작성 및 정량화- (PIXE Analysis of Aerosol Particles - Preparation of Standard Samples and Calibration Test -)

  • 崔琴簒
    • 한국대기환경학회지
    • /
    • 제7권2호
    • /
    • pp.114-118
    • /
    • 1991
  • Particle Induce X-Ray Emission (PIXE) analysis is one of the most useful methods which can determine the elemental concentration of aerosol particles in nano-gram range. The main purpose of this paper is to establish the measurement system and the procedure of PIXE analysis. The standard samples were prepared to calibrate the PIXE analysis by three different techniques. The linear relationships between the peak counts from PIXE spectra and the mass density from RBS spectra were obtained for each standardized element under the applied measurment geometry and conditions. The sensitivity curves for PIXE analysis were determined from these relationships.

  • PDF

여름철 북태평양고기압 하에서 사쿠라지마 화산 분출(2018년 7월 16일)이 부산지역 초미세먼지 농도에 미치는 영향 (Effect of Sakurajima Volcanic Eruption (July 16, 2018) on PM2.5 Concentration in Busan under Summertime North Pacific High Pressure Condition)

  • 전병일
    • 한국환경과학회지
    • /
    • 제31권6호
    • /
    • pp.503-513
    • /
    • 2022
  • This research investigated the effect of the eruption of Japan Sakurajima volcano on the concentration of ultrafine particle when the north Pacific high pressure exists in the Busan in summer. As a result of analyzing the forward trajectory using the HYSPLIT model, the air parcel from Sakurajima volcano passed through the sea in front of Busan at 1500 LST on July 17, 24 hours after the volcanic eruption. As a result of analyzing the PM10 and PM2.5 concentrations in the Busan for two days from July 16 to 17, 2018, the Sakurajima eruption in Japan, it can be seen that there was a high increase in PM10 and PM2.5 concentrations compared to the previous day. As a result of analyzing the backward trajectory, the air mass that reached Busan at 1300 LST on July 17, 2018 has moved near the Sakurajima volcano at 1,500 m, 2,000 m, and 3,000 m. The concentration of SO42- in PM2.5, the concentration of all three stations in Busan showed a sharp increase from 1000 LST on July 17th. Looking at the NH4+ concentration in PM2.5, it shows a very similar variation trend to SO42-, and the correlation coefficient between the two components is 0.96 for Jangrimdong and Yeonsandong, and 0.85 for Busan New Port. Looking at the NO3- concentration in PM2.5, the same high concentrations as SO42 and NH4+ were not observed in the afternoon of July 17th.

광산란법을 이용한 국내 석탄화력발전소 굴뚝에서 배출되는 PM10, PM2.5 측정 및 분석 (Measurement and analysis of PM10 and PM2.5 from chimneys of coal-fired power plants using a light scattering method)

  • 신동호;김영훈;홍기정;이건희;박인용;김학준;김용진;한방우;황정호
    • 한국입자에어로졸학회지
    • /
    • 제16권4호
    • /
    • pp.131-140
    • /
    • 2020
  • Air pollutants emitted from chimneys of coal-fired power plants are considered to be a major source of fine particulate matter in the atmosphere. In order to manage fine particle in the chimney of a coal-fired power plant, it is necessary to know the concentration of fine particle emitted in real time, but the current system is difficult. In this study, a real-time measurement system for chimney fine particle was developed, and measurements were performed on six coal-fired power plants. Through the measurements, the mass concentration distribution according to the particle size could be secured. All six chimneys showed bimodal distribution, and the count median diameters of each mode were 0.5 and 1.1 ㎛. In addition, it was compared with the gravimetric measurement method, and it was determined that the relative accuracy for PM10 was within 20%, and the value measured using the developed measuring instrument was reliable. Finally, three power plants were continuously measured for one month, and as a result of comparing the concentration of PM10 according to the amount of power generation, it was confirmed that the PM10 discharged from the chimney increased in the form of an exponential function according to the amount of power generation.

Nanometrology and its perspectives in environmental research

  • Kim, Hyun-A;Seo, Jung-Kwan;Kim, Taksoo;Lee, Byung-Tae
    • Environmental Analysis Health and Toxicology
    • /
    • 제29권
    • /
    • pp.16.1-16.9
    • /
    • 2014
  • Objectives Rapid increase in engineered nanoparticles (ENPs) in many goods has raised significant concern about their environmental safety. Proper methodologies are therefore needed to conduct toxicity and exposure assessment of nanoparticles in the environment. This study reviews several analytical techniques for nanoparticles and summarizes their principles, advantages and disadvantages, reviews the state of the art, and offers the perspectives of nanometrology in relation to ENP studies. Methods Nanometrology is divided into five techniques with regard to the instrumental principle: microscopy, light scattering, spectroscopy, separation, and single particle inductively coupled plasma-mass spectrometry. Results Each analytical method has its own drawbacks, such as detection limit, ability to quantify or qualify ENPs, and matrix effects. More than two different analytical methods should be used to better characterize ENPs. Conclusions In characterizing ENPs, the researchers should understand the nanometrology and its demerits, as well as its merits, to properly interpret their experimental results. Challenges lie in the nanometrology and pretreatment of ENPs from various matrices; in the extraction without dissolution or aggregation, and concentration of ENPs to satisfy the instrumental detection limit.