• Title/Summary/Keyword: Particle filters

Search Result 231, Processing Time 0.024 seconds

Processing Methods for the Preparation of Porous Ceramics

  • Ahmad, Rizwan;Ha, Jang-Hoon;Song, In-Hyuck
    • Journal of Powder Materials
    • /
    • v.21 no.5
    • /
    • pp.389-398
    • /
    • 2014
  • Macroporous ceramics with tailored pore size and shape could be used for well-established and emerging applications, such as molten metal filtration, biomaterial, catalysis, thermal insulation, hot gas filtration and diesel particulate filters. In these applications, unique properties of porous materials were required which could be achieved through the incorporation of macro-pores into ceramics. In this article, we reviewed the main processing techniques which can be used for the fabrication of macroporous ceramics with tailored microstructure. Partial sintering, replica templates, sacrificial fugutives, and direct foaming techniques was described here and compared in terms of microstructures and mechanical properties that could be achieved. The main focus was given to the direct foaming technique which was simple and versatile approach that allowed the fabrication of macro-porous ceramics with tailored features and properties.

Filtration Characteristics of Magnetic Fibrous Polymeric Filter Elements for Industrial Lub-systems (산업용 자성폴리머 필터소재의 여과특성 연구)

  • 안병길;최웅수;이용훈;정용진;권오관
    • Tribology and Lubricants
    • /
    • v.12 no.3
    • /
    • pp.39-47
    • /
    • 1996
  • The magnetic fibrous polymeric oil filter elements for industrial lub-systems were obtained by pneumoextrusion processing prepared from thermoplastic pqlymer (polyamide) containing a magnetic particulate filler (Ba ferrite), and treated subsequently in a magnetic fields. Using the standard laboratory oil filtration test rig, metallic particle quantifier and image analyser system, the dependence of filtration charateristics of the magnetic filter media on the parameters of porosity and magnetic properties was investigated. The pressure drops and efficiencies of lubricating filter elements were measured on the packing density and magnetised filler content of filter element. Also, the industrial lub-systems such as lubricant filters for gear test rig and electric discharge processing machine were used for testing the flitrational characteristics of tl, c magnetised filter elements. The magnetic fibrous polymeric filter material was shown to possess a highly filtration efficiency in filtering the fine ferrous particles with increasing the magnetic force of filter element. Therefore, it is expected that the magnetic fibrous polymeric filter material should be used for effective oil filrers on the industrial lub-systems.

PIV Measurements of the Pressure Driven Flow Inside a T-Shaped Microchannel (T형 마이크로채널 내부 압력구동 유동의 PIV 계측)

  • Choi Jayho;Lee In-Seop
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.423-426
    • /
    • 2002
  • A custom micro-PIV optics assembly has been used to measure the flow field inside a T-shaped microchannel. The micro-PIV system consists of microscope objectives of various magnifications, a dichroic cube, and an 8-bit CCD camera. Fluorescent particles of diameters 620nm have been used with a Nd:YAG laser and color filters. A programmable syringe pump with Teflon tubings were used to inject particle-seeded distilled water into the channel at flow rates of $420,\;40,\;60{\mu}L/hr$. The microchannels are fabricated with PDMS with a silicon mold, then $O_2-ion$ bonded onto a slide glass. Results show differences in flow characteristics and resolution according to fluid injection rates, and magnifications, respectively. The results show PIV results with vector-to-vector distances of $2{\mu}m$ with 32 pixel-square interrogation windows at $50{\%}$ overlap.

  • PDF

Nonlinear Bearing Only Target Tracking Filter (방위각 정보만을 이용한 비선형 표적추적필터)

  • Yoon, Jangho
    • Journal of Aerospace System Engineering
    • /
    • v.10 no.1
    • /
    • pp.8-14
    • /
    • 2016
  • The optimal estimation of a bearing only target tracking problem be achieved through the solution of the Fokker-Planck equation and the Bayesian update. Recently, a nonlinear filtering algorithm using a direct quadrature method of moments in which the associated Fokker-Planck equation can be propagated efficiently and accurately was proposed. Although this approach has demonstrated its promising in the field of nonlinear filtering in several examples, the "degeneracy" phenomenon, similar to that which exists in a typical particle filter, occasionally appears because only the weights are updated in the modified Bayesian rule in this algorithm. Therefore, in this paper to enhance the performance, a more stable measurement update process based upon the update equation in the Extended Kalman filters and a more accurate initialization and re-sampling strategy for weight and abscissas are proposed. Simulations are used to show the effectiveness of the proposed filter and the obtained results are promising.

Characteristics of Electrostatic Cyclone-Bag Filter with Upper Inlet (상부유입식 전기 Cyclone-Bag Filter의 특성)

  • 여석준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.2
    • /
    • pp.179-190
    • /
    • 2000
  • The main object of this study was to investigate experimentally the characteristics of electrostatic cyclone-bag filter with upper tangential inlet in order to overcome the low collection efficiency for the submicron particle and high pressure drop which were main problems of general fabric bag filters. The experiment was carried out for the analysis of collection efficiency and pressure drop of electrostatic cyclone-bag filter comparing to those of fabric bag filter with various experimental parameters such as the inlet velocity(filtration velocity) and applied voltage etc. In the results the upper tangential inlet type showed higher collection efficiency for submicron particles below 2 ${\mu}{\textrm}{m}$ in diameter than that of center inlet and over 99.9% for overall collection efficiency. Pressure drop reduction ratios were shown as 40-50% for the applied voltage 0kV by centrifugal force and 70-90% for 20k V by the centrifuga and electrostatic force with the tangential inlet velocity (12-21m/s)

  • PDF

Study on Cake Resistance and Microfiltraion Performance of Rotating Membrane Filters (회전막 정밀여과기에서 케이크 저항과 여과성능에 대한 연구)

  • 박원철;최창균;김재진;박진용
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.105-109
    • /
    • 1998
  • 1. Introduction : In microfiltration the transport, deposition and removal of particles control cake formation on a filter. In this connection a new model on cake formation, based on the wall shear stress, was tested here in comparison with experiments of fine particle slurry under Taylor-vortex flow. The model expresses the deposition process for particles as two first-order steps in series of mass transfer and adhesion, and their removal process as a linear relation to the wall shear stress. This embraces characteristics of both dead-end and crossflow filtration. The correlation resulting from fitting to experimental data represented the experimental data reasonably well. This study will be helpful in analyzing fouling in heat exchangers.

  • PDF

Concentration of NH$_4$NO$_3$ in TSP in Seoul Ambient Air (서울시 부유분진증 질산암모늄 농도)

  • 천만영;이영재;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.2
    • /
    • pp.130-136
    • /
    • 1994
  • Concentration of volatile particulate nitrate(NH$_4$NO$_3$) in TSP in ambient air was determined from Feb. to Oct 1993. Sampling was carried out using a two-stage Andersen air sampler at the top of a five-story building located at Kon- Kuk University in Seoul Concentration of NH$_4$NO$_3$ in TSP was measured by Pyrolysis of sample filters at 16$0^{\circ}C$ for 1hr. Concentration of NH$_4$NO$_3$ was higher in winter time compared with that in summer time. Also, concentration of NH$_4$NO$_3$ was higher in fine particles compared with that in coarse particle. The range of NH$_4$NO$_3$concentration was between 2.99 and 9.86 $\mu\textrm{g}$/㎥. Weight fraction of NH$_4$NO$_3$ in total particulate nitrate was 31.1~59.5%, and weight fraction of NH$_4$NO$_3$ in YSP was 2.1~11.2%.

  • PDF

Soccer Player Tracking Using Blob Assignation (이미지 블롭 할당을 이용한 축구 선수 추적)

  • Park, Kyuhyoung;Changsoo Je;Yongdeuk Seo
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.10b
    • /
    • pp.616-618
    • /
    • 2003
  • In this paper particle filter is used as an underlying algorithm to track multiple objects, which are soccer players. Multi-object tracking becomes difficult when two or more players get close to and overlap each other because particles of the filters tend to move to a region of higher posterior probability. To resolve this problem, a blob assignation algorithm which identifies the separated image blobs after occlusion, based on the predicted states according to the dynamic model is suggested. This method performed well on the sequences under general camera work.

  • PDF

A Study for Application of DAF Technology to Remove Chrolophyl-a and Dissolved Organic Compound in Yongdam Reservoir (용담호소 내 Chlorophyl-a와 유기물 저감을 위한 부상기법 적용 연구)

  • Dockko, Seok;Lee, Hyungjib
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.303-309
    • /
    • 2006
  • Yongdam reservoir located in Jeoliabuk-do has had a lot of concerns for its algal blooming since it has started to fill water. Many water utilities near Yongdam area use reservoirs even though they have some problems with certain algae that cause tastes and odors and clog filters. In this research, dissolved air flotation (DAF) technology was examined for feasibility for removal of algae. OAF can save the capital cost for its compactness, because its hydraulic loadings (overflow rates) are 10 times higher than sedimentation, and hydraulic detention times are much shorter, typically 5 to 15 minutes. As a result of this research, PAC is effective rather than Alum to DAF for pretreatment. Higher DOC plays an important role to change zetapotential negatively to inhibit destabilization of particle to coagulation. The length of pipeline to carry pressurized water into reactor does not affect reaction.

A Study on Filtration System Model and Comparative Performance Tests of Automotive (여과시스템 모델과 자동차 연료필터의 비교성능시험 연구)

  • 이재천
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.3
    • /
    • pp.194-201
    • /
    • 2003
  • This study presents the comparative filtration performance evaluation of automotive fuel filters based on the theory of Beta ratio. For the experiments, the fuel component's test stand incorporating the multi-pass filtration test circuit was developed. A mathematical description of filtration process in general was derived. And the theoretical basis of multi-pass test and the test procedure were described in detail. Experimental results revealed that domestic fuel filter tested could not maintain consistent Beta ratio, that is filtration efficiency, although it had the holding capacity of contaminants close to the specification at maximum pressure drop across the filter assembly. The results of experiments and simulations also showed that filtration system model could be refined including desorption ratio to estimate the variable Beta ratio in service life.