• Title/Summary/Keyword: Particle filters

Search Result 231, Processing Time 0.025 seconds

Characterization and Microstructure of an Extruded Flat-Tubular-Type Alumina Filter (압출공정에 의한 수 처리용 평관형알루미나 필터의 미세구조와 특성평가)

  • Bae, Byung-Seo;Ha, Jang-Hoon;Song, In-Hyuck
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.5
    • /
    • pp.406-412
    • /
    • 2014
  • In this study, flat-tubular-type alumina filters were manufactured using alumina powder of two sizes ($2.4{\mu}m$ ALM-44 and $0.4{\mu}m$ AP 400) by an extrusion process. The manufactured alumina filter was sintered at $1200-1600^{\circ}C$ for 1 h. As particle size increased, the largest pore size, average pore size and porosity increased; but density and linear shrinkage decreased. The alumina filter fabricated using ALM-44 powder sintered at $1500^{\circ}C$ was confirmed as the best water treatment filter after investigation of the bending strength, water permeability and impurity-removal efficiency of the experimental filters. This flat-tubular-type alumina filter is expected to be useful not only for direct water treatment, but also for use as a support filter during coating processes, to control pore size.

Filtration Performance of Fibrous Air Filter under External Electric Field using Insulated Electrodes (외부전기장 적용 섬유상 에어필터의 절연 전극 사용에 따른 여과특성)

  • Ji, Sung-Mi;Sohn, Jong-Ryeul;Park, Hyun-Seol
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.6
    • /
    • pp.675-687
    • /
    • 2012
  • Applying an external electric field across air filter media is one of methods to improve the filtration performance. Metal wire meshes have been commonly used as electrodes situated on both sides of a thick filter pad. For a thin filter medium a short circuit, known as the biggest drawback for applying an external electric field to air filter, can occur at the closest point between electrodes. In this study several types of insulated meshes were prepared by coating #50 meshes with a dielectric material, Nylon 66, and the filtration property of air filter was evaluated at the presence of external electric field using those insulated meshes as electrodes and compared with that of filters using bared meshes. The collection efficiency of tested filter was increased from 78% to 95% for singly charged 100 nm particles by application of external electric field. As a result, there was no significant difference in collection efficiency between filters with insulated and bared electrodes. Similar results could be also seen from the tests using polydisperse particles. Finally, through this study, we found that the insulation of mesh electrodes doesn't affect the filtration performance of fibrous air filter under external electric field.

Simultaneous NO2 and RSP Measurements Using Filtration Method (필터방식을 이용한 이산화질소 및 호흡성 분진의 동시 측정)

  • Yang, Won-Ho;Im, Sung-Kuk;Kim, Moon-Hyeon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.2
    • /
    • pp.148-152
    • /
    • 2008
  • Coated filters were developed to replace the glass impinger methods that use reagent solutions. The purpose of this study was to simultaneously measure nitrogen dioxide ($NO_2$) and respirable suspended particles (RSP) by a filtration method with a cyclone connected to a pump. A first pre-filter for RSP and second filter for $NO_2$, which was soaked in a TEA (Triethanolamine) solution, were loaded into a filter cassette with a pump flow rate of 1.7 l/m. After sampling, the TEA soaked filter was removed from the cassette, placed in a large test tube (10 ml), mixed, and allowed time to develop. The absorbance (abs) of the diazo compound of the $NO_2$ and N-(1-Napthylethylenediamine dihydrochloride) in the color reagent was measured at 545 nm on a spectrophotometer. The collection efficiency(%) of $NO_2$ by each 3 filter soaked in TEA solution and used in the cyclone with a pump flow rate 1.7 l/m was $89{\pm}3%$ and the correlation coefficient between the true $NO_2$ concentration and that determined by the TEA soaked filters was 0.993(p<0.001).

EffECTIVE PARTICULATES REDUCTION IN DIESEL ENGINES THROUGH THE USE OF FUEL CATALYSED PARTICULATE FILTERS

  • Vincent, M.-W.;Richards, P.-J.;Rogers, T.-J.
    • International Journal of Automotive Technology
    • /
    • v.3 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • There is Increasing world-wide interest in diesel particulate filters (DPF) because of their proven effectiveness in reducing exhaust smoke and particulate emissions. Fine particulates have been linked to human health . DPF use requires a means to secure the bum-out of the accumulated soot, a process called regeneration. If this is not achieved, the engine cannot continue to operate. A number of techniques are available, but most are complex, expensive or have a high electrical demand. The use of fuel additives to catalyse soot bum-out potentially solves the problem of securing regeneration reliably and at low cost. Work on organo-metallic fuel additives has shown that certain metals combine to glove exceptional regeneration performance. Best performance was achieved with a combination of iron and strontium based compounds. Tests were carried out un a bed engine and on road vehicles, which demonstrated effective and reliable regeneration from a tow dose fuel additive, using a single passive DPF. No control valves, flow diverters. heaters or other devices were employed to assist regeneration. Independent particle size measurements showed that there were no harmful side effects from the use of the iron-strontium fuel additive.

Comparison of the filtration performance by different media in pretreatment of seawater desalination by reverse osmosis (여재 종류에 따른 역삼투법 해수담수화 시설 전처리 여과공정의 성능비교)

  • Kim, Seung-Hyun;Yoon, Jong-Sup;Lee, Seockheon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.2
    • /
    • pp.215-222
    • /
    • 2009
  • This study compares the performance of the filters with various media in pretreatment of seawater desalination by reverse osmosis. For this purpose, Masan bay seawater is used as raw water. The filter performance is evaluated by the filtrate quality and the head loss development. Five media is selected in this study: anthracite, $Filtralite^{(R)}$, sand, Pumice, $AFM^{(R)}$. These media are used in combination for dual media filter and alone for mono media filter. The comparison results show that NC0.8-1.6 is the best $Filtralite^{(R)}$. The dual media filter of NC0.8-1.6 and sand outperformed other filters in particle removal. The dual media filter of anthracite and sand showed good performance in organic removal. The mono media filter of Pumice produced the similar filtrate quality as the mono media filter of sand although the effective size of Pumice is considerably greater than that of sand. Due to big size, head loss development is maintained slow in the filtration of Pumice.

Performance assessment of HEPA filter to reduce internal dose against radioactive aerosol in nuclear decommissioning

  • Hee Kwon Ku;Min-Ho Lee;Hyunjin Boo;Geun-Dong Song;Deokhee Lee;Kaphyun Yoo;Byung Gi Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1830-1837
    • /
    • 2023
  • The thermal cutting of contaminated or activated metals during decommissioning nuclear power plants inevitably results in the release of radioactive aerosol. Since radioactive aerosols are pernicious particles that contribute to the internal dose of workers, air conditioning units with a HEPA filter are used to remove radioactive aerosols. However, a HEPA filter cannot be used permanently. This study evaluates the efficiency and lifetime of filters in actual metal cutting condition using a plasma arc cutter and a high-resolution aerosol detector. The number concentration and size distribution of aerosols from 6 nm to 10 ㎛ were measured on both the upstream and downstream sides of the filter. The total aerosol removal efficiency of HEPA filter satisfies the standard of removing at least 99.97% of 0.3 ㎛ airborne particles, even if the pressure drop increases due to dust feeding load. The pressure drop and particle size removal efficiency at 0.3 ㎛ of the HEPA filter were found to increase with repeated cutting experiments. By contrast, the efficiency of used HEPA filter reduced in removing nano-sized aerosols by up to 79.26%. Altogether, these results can be used to determine the performance guidance and replacement frequency of HEPA filters used in nuclear power plants.

Clogging Phenomenon and Drainage Capacity of Tunnel Filters (터널필터재의 폐색현상과 배수성능 평가)

  • 이인모;유승헌;박광준;이석원;김홍택
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.5
    • /
    • pp.3-18
    • /
    • 1999
  • The geotextile filter, which is installed between the ground and the lining and used as a tunnel drainage system, should have sufficient groundwater drainage capacity so that water pressure does not act on the lining. The clogging may have a serious effect on the long term behaviour of geotextile filters. Two typical weathered residual soils in Korea, Shinnae-dong soil and Poi-dong soil, were chosen to investigate the in-plane flow characteristics of the soils with varying degree of compressive stresses applied on the geotextiles and with various conditions of hydraulic gradient. The Shinnae-dong soil is a relatively coarse material classified as'SW-SM'; on the other hand, the Poi-dong soil is much finer and is classified as'SC'. Based on the comparison of the $O_{95}$ of geotextile to the $D_{15}$ of residual soils, existing clogging criteria were reviewed, and a tentative clogging criterion for the in-plane flow of the residual soil through filters was proposed. The Shinnae-dong soil showed noticeable clogging phenomenon, while the clogging of the Poi-dong soil was not so serious. The Poi-dong soil seemed to be hindered in particle transport by its cohesiveness.

  • PDF

Effect of Particle Loading on the Collection Performance of an Electret Cabin Air Filter for Submicron Particles (입자 퇴적이 승용차용 정전 필터의 미세 입자 포집 특성에 미치는 영향)

  • Ji, Jun-Ho;Gang, Seok-Hun;Hwang, Jeong-Ho;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1102-1114
    • /
    • 2002
  • An electret filter is composed of permanently charged electret fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using poly-disperse particles when submicron particles were loaded. Long-term experiments were conducted by applying two different charging states, which were spray electrification and charge equilibrium by bipolar ionization. In order to investigate the effect of particle loading in filter media, NaCl particles were generated from 0.1% and 1% solutions by an atomizer. Liquid DOS particles were used to evaluate the effect of liquid particles on the collection efficiency of an electret filter. The results show significant effect of charge amount and size distribution of loading particles on the collection performance of a filter media in submicron region. Smaller particles loaded in electret fibers cause a more rapid degradation in collection efficiency and have lower minimum efficiency with time. The pressure drop of a filter media do rarely increase when the collection efficiency decreases to the minimum value. For the larger particles charged by spray electrification, which have charge amounts more than that of Boltzmann equilibrium charge distribution, the pressure drop of a filter media slowly increases in comparison with that of equilibrium charged particles. For DOS particles it is shown that the charging level of an electret filter severely decreases and the collection efficiency is below 10% in some particle size range.

Biomonitoring of Metal Exposure During Additive Manufacturing (3D Printing)

  • Ljunggren, Stefan A.;Karlsson, Helen;Stahlbom, Bengt;Krapi, Blerim;Fornander, Louise;Karlsson, Lovisa E.;Bergstrom, Bernt;Nordenberg, Eva;Ervik, Torunn K.;Graff, Pal
    • Safety and Health at Work
    • /
    • v.10 no.4
    • /
    • pp.518-526
    • /
    • 2019
  • Background: Additive manufacturing (AM) is a rapidly expanding new technology involving challenges to occupational health. Here, metal exposure in an AM facility with large-scale metallic component production was investigated during two consecutive years with preventive actions in between. Methods: Gravimetric analyzes measured airborne particle concentrations, and filters were analyzed for metal content. In addition, concentrations of airborne particles <300 nm were investigated. Particles from recycled powder were characterized. Biomonitoring of urine and dermal contamination among AM operators, office personnel, and welders was performed. Results: Total and inhalable dust levels were almost all below occupational exposure limits, but inductively coupled plasma mass spectrometry showed that AM operators had a significant increase in cobalt exposure compared with welders. Airborne particle concentrations (<300 nm) showed transient peaks in the AM facility but were lower than those of the welding facility. Particle characterization of recycled powder showed fragmentation and condensates enriched in volatile metals. Biomonitoring showed a nonsignificant increase in the level of metals in urine in AM operators. Dermal cobalt and a trend for increasing urine metals during Workweek Year 1, but not in Year 2, indicated reduced exposure after preventive actions. Conclusion: Gravimetric analyses showed low total and inhalable dust exposure in AM operators. However, transient emission of smaller particles constitutes exposure risks. Preventive actions implemented by the company reduced the workers' metal exposure despite unchanged emissions of particles, indicating a need for careful design and regulation of the AM environments. It also emphasizes the need for relevant exposure markers and biomonitoring of health risks.

MRF Particle filter-based Multi-Touch Tracking and Gesture Likelihood Estimation (MRF 입자필터 멀티터치 추적 및 제스처 우도 측정)

  • Oh, Chi-Min;Shin, Bok-Suk;Klette, Reinhard;Lee, Chil-Woo
    • Smart Media Journal
    • /
    • v.4 no.1
    • /
    • pp.16-24
    • /
    • 2015
  • In this paper, we propose a method for multi-touch tracking using MRF-based particle filters and gesture likelihood estimation Each touch (of one finger) is considered to be one object. One of frequently occurring issues is the hijacking problem which means that an object tracker can be hijacked by neighboring object. If a predicted particle is close to an adjacent object then the particle's weight should be lowered by analysing the influence of neighboring objects for avoiding hijacking problem. We define a penalty function to lower the weights of those particles. MRF is a graph representation where a node is the location of a target object and an edge describes the adjacent relation of target object. It is easy to utilize MRF as data structure of adjacent objects. Moreover, since MRF graph representation is helpful to analyze multi-touch gestures, we describe how to define gesture likelihoods based on MRF. The experimental results show that the proposed method can avoid the occurrence of hijacking problems and is able to estimate gesture likelihoods with high accuracy.