• 제목/요약/키워드: Particle filters

검색결과 231건 처리시간 0.019초

Application of magnetic field to iron contained dust capture

  • Huang, Shan;Park, Hae-Woo;Jo, Young-Min;Park, Young-Koo;Kim, Youn-Che
    • 한국응용과학기술학회지
    • /
    • 제31권1호
    • /
    • pp.59-65
    • /
    • 2014
  • Indoor air quality including metro subway is of recent interests in large cities. Inflow air to the inside of the train and circulating air flow through MVAC of stations contain large amount of iron based fine particles. This paper evaluated the collection of such a dust by magnetic filters as comparing to conventional particle capturing mechanisms such as inertia, direct impaction and diffusion. It was found that filtration velocity, magnetic field intensity, and fiber size were the most important parameters for magnetic filtration. Application of magnetic force obviously enhances the collection efficiency particularly in fine modes smaller than 10 mm. However, its effect was found greater in 2.5 mm than submicron particles.

고무용(用) 국산(國産) 각종충전제(各種充塡劑)에 관(關)한 연구(硏究) (제1보(第1報)) 고무용(用) 국산(國産) 탄산(炭酸)칼슘의 성능(性能)에 관(關)하여 (Studios on the Various Filters for Rubber Compounds. Part 1. Physical Properties of Domestic Calcium Carbonate for NR Compounds)

  • 이명환;안영필
    • Elastomers and Composites
    • /
    • 제5권1호
    • /
    • pp.69-74
    • /
    • 1970
  • The influence of various calcium carbonate on the physical properties of natural rubber have teen carries out extensive experiments on compounding. Final evaluation was made through various kinds of physical test-tensile strength, modulus, tear strength and hardnees-including particle size. The results are as follows: 1. Generally, tile tensile strength, modulus and tear strength showed the similar tendency in various calcium carbonate compounding. 2. The maximum volume of general using have been obtained with 150 phr calcium carbonate in $NR-CaCO_3$ compounding. 3. The particle size of domestic calcium carbonate showed $1.0\mu-2.6\mu$.

  • PDF

초미세먼지 제거를 위한 전기집진 필터에 관한 연구 (Electric Collection Filter for Ultrafine Dust Removal)

  • 김용선;고상철
    • 한국기계가공학회지
    • /
    • 제21권5호
    • /
    • pp.40-45
    • /
    • 2022
  • In recent years, indoor air pollution has become a crucial environmental problem. Hence, the purification of indoor air is an important issue. Typical physical filters show relatively high dust collection efficiency at a dust particle size of more than 5.0 ㎛ but extremely low efficiency at an ultrafine size of less than 2.5 ㎛. In this study, an electric field filter was proposed to capture ultrafine dust with a size of less than 5.0 ㎛. Simulation results showed that the electric field filter effectively removed ultrafine dust. In addition, sufficient dust collection efficiency was obtained even with a simple plate-shaped filter without bending the Chevron filter.

인공지능 공간상의 다중객체 구분을 위한 컬러 패턴 인식과 추적 (Color Pattern Recognition and Tracking for Multi-Object Tracking in Artificial Intelligence Space)

  • 진태석
    • 한국산업융합학회 논문집
    • /
    • 제27권2_2호
    • /
    • pp.319-324
    • /
    • 2024
  • In this paper, the Artificial Intelligence Space(AI-Space) for human-robot interface is presented, which can enable human-computer interfacing, networked camera conferencing, industrial monitoring, service and training applications. We present a method for representing, tracking, and objects(human, robot, chair) following by fusing distributed multiple vision systems in AI-Space. The article presents the integration of color distributions into particle filtering. Particle filters provide a robust tracking framework under ambiguous conditions. We propose to track the moving objects(human, robot, chair) by generating hypotheses not in the image plane but on the top-view reconstruction of the scene.

스마트폰 기반 형광 smartscope의 입자계수 및 회전하는 나선형 채널의 입자정렬 성능 평가 (Evaluation of Particle Counting by Smartphone-based Fluorescence Smartscope and Particle Positioning in Spinning Helical Channel)

  • 박은정;김수빈;조명옥;김경훈;모히우띤;김선욱;이정훈;김중경
    • 한국산업정보학회논문지
    • /
    • 제20권3호
    • /
    • pp.19-28
    • /
    • 2015
  • 스마트폰의 영상정보처리에 기반한 현장 진단기기 개발을 목표로 입자계수용 형광 smartscope와 DC 모터로 제어되는 입자정렬 시스템을 제작하였다. 크기가 작고 저렴한 비용으로 비전문가도 쉽게 다룰 수 있는 smartscope는 LED, 볼렌즈, 형광필터가 설치된 어댑터가 스마트폰 카메라 앞에 장착되어 전용 애플리케이션으로 형광입자와 형광염색된 백혈구를 계수할 수 있었다. 모터는 안드로이드 스마트폰의 블루투스 무선통신 기능을 통해 제어되었다. 나선형 미세유동채널이 축을 중심으로 회전하는 동안 백혈구와 크기가 유사한 입자가 정렬되는 현상을 관찰하였다. 모터로 회전 방향과 속도가 조절되는 입자 정렬 시스템은 많은 시간이 소요되는 수작업을 최소화하고 시료 전처리 과정을 자동화할 수 있으므로, smartscope와 통합될 경우 스마트폰을 이용한 현장진단기기에 활용될 수 있을 것이다.

공기조화기 장착용 축상유입식 싸이클론의 입자제거효율에 대한 실험적 연구 (Experimental Study on Particle Collection Efficiency of Axial-flow Cyclone in Air Handling Unit)

  • 김세영;권순박;박덕신;조영민;김진호;김명준;김태성
    • 한국대기환경학회지
    • /
    • 제27권3호
    • /
    • pp.272-280
    • /
    • 2011
  • A novel particle removal system for air handling unit (AHU) of subway station was evaluated experimentally. The novel system was designed in order to minimize the maintenance cost by applying axial-flow cyclones. The system consists of multiple cyclone units and dust trap. Based on our previous numerical study, it was found to be effective for removal $1\sim10{\mu}m$ sized dust particles. In this study, we manufactured the mock-up model and evaluated the model experimentally. Liquid and solid test particles were generated for evaluating collection efficiency of the system and the pressure drop was monitored. The collection efficiency was varied from 41.2% to 85.9% with increasing the sizes of particle from 1 to $6.5{\mu}m$ by particle count ratio of inlet and outlet. The pressure drop was maintained constant less than $20mmH_2O$. In addition, the collection efficiency was estimated by total mass for solid test particles. It was found that the collection efficiency was 65.7% by particle mass ratio of inlet and outlet. It shows that present system can replace current pre-filters used in subway HVAC system for removing particulate matters with minimal operational cost.

언센티드 파티클 필터를 이용한 비선형 시스템 상태 추정 (Nonlinear System State Estimating Using Unscented Particle Filters)

  • 권오신
    • 한국정보통신학회논문지
    • /
    • 제17권6호
    • /
    • pp.1273-1280
    • /
    • 2013
  • 움직이는 물체를 추적함에 있어 언센티드 칼만 필터(UKF) 알고리즘은 미분 계산없는 빠른 수렴속도와 뛰어난 추정 성능을 지녔다. 그러나 이 방법은 가우시안 잡음 분포 하에서 적용해야 하는 등 제한적인 조건이 수반되는 문제점을 안고 있다. 반면에 파티클 필터(PF)는 제한적인 조건 없이 비선형/비가우시안 시스템에도 적용할 수 있는 상태 추정기법 이라 할 수 있겠다. 그러나 이 방법 또한 파티클의 갯수가 늘어나면 계산량이 크게 증가하는 등의 단점을 지니고 있다. 본 논문에서는 이러한 단점들을 극복하기 위하여 UKF와 PF를 결합한 언센티드 파티클 필터(UPF) 알고리즘을 제안하였다. 본 알고리즘의 성능을 확인하기 위하여 기존의 PF와 UPF 알고리즘을 2-자유도 펜듈럼 시스템을 이용하여 시뮬레이션 하였다. 결과적으로 본 논문에서 제안한 방법이 PF에 비하여 비선형/비가우시안 시스템의 상태 추정에 더욱 적합 함을 확인할 수 있었다.

大氣中 重金屬의 粒經分布에 關한 硏究 (Studies on Particle Size Distribution of Heavy Metals in the Atmosphere)

  • 손동헌;강춘원
    • 한국대기환경학회지
    • /
    • 제2권3호
    • /
    • pp.57-63
    • /
    • 1986
  • Atmospheric particulate matter (A.P.M.) was collected on quartz fiber filters from March 1985 to May 1986 according to particle size using Andersen high-volume air sampler, and 6 heavy metals (Fe, Mn, Cu, Ni, Zn, Pb) in these particulates were analyzed by atomic absorption spectrophotometry. The arithmetic mean concentration of A.P.M. was 195.57$\mug/m^3$. The arithmetic mean concentrations of 6 metals (Fe, Mn, Cu, Ni, Zn and Pb) were 3385.04, 1451.67, 897.94, 159.68, 127.14 and 59.49 $ng/m^3$ respectively. The order of heavy metals contributing to A.P.M. was as follows: Fe > Zn > Pb > Cu > Mn > Ni. These heavy metals were devided into 3 groups according to their particle size distribution. The contents of heavy metals belonging to the 1st group (Fe, Mn) were increased with the particle size. On the contrary, the content of Pb belonging to the 2nd group (Pb) was increased with the decrease in the particle size. The heavy metal contents in the 3rd group (Ni, Cu, Zn) were lowest in the particle size range of 2.0-3.3 $\mum$ compared with particles larger or smaller tha this range. The seasonal variation of heavy metal concentration were as follows: Fe and Mn contents were highest in spring, but Ni and Pb contents were highest in winter. Statistical analysis showed that there was a significant correlation between A.P.M. and Fe in coarse particles, meanwhile between A.P.M. and Pb in the case of fine particles.

  • PDF

2003년부터 2015년까지 CA 인증 공기청정기의 성능 시험 결과 분석 (Analysis of performance test results of CA-certified air cleaners from 2003 to 2015)

  • 김학준;홍기정;우창규;한방우;김용진
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.17-23
    • /
    • 2017
  • In this study, the test results obtained from the performance tests for CA (Korea Association of Cleaning Air) certificated air cleaners which had been commercially available in Korea from 2003 to 2015 were analyzed. Among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level, noise level and CADR were correlated with flow rates. Collection and odor removal efficiencies were 20% higher than the limit of the CA certification. The ozone emissions from the air cleaners were negligible because all the air cleaners were equipped with only HEPA filters, not electrostatic precipitation method which produces ozone.

집진용 세라믹 필터의 제조 및 공기 투과 특성 (Preparation of Ceramic Foam Filter and Air Permeability)

  • 박재구
    • 한국대기환경학회지
    • /
    • 제16권4호
    • /
    • pp.381-388
    • /
    • 2000
  • Ceramic foam prepared with cordierite as a starting material by foam method was tested to evaluate the feasibility as a filter for the dust collection in hot gas. Two different types of agents Benzethonium chloride (BZTC, C27H42NO2Cl) and Sodium Lauryl Sulfate(SLS, CH3(CH2)11OSO3Na) were used as foaming agents in foaming process. Porosityof ceramic foam was about 80% and mean pore size were 100${\mu}{\textrm}{m}$ for SLS agent and 200 ${\mu}{\textrm}{m}$ for BZTC. It was observed that ceramic foam was composed of continuous macro-pore structure with opening windows interconnecting macro-pores. The surface of ceramic foam support of was coated with cordierite particles ranged from 20${\mu}{\textrm}{m}$ to 50${\mu}{\textrm}{m}$ Meso-pore size in the coating layer on ceramic foam was below 10${\mu}{\textrm}{m}$. While air permeability of the support increased with increasing macro-pore size coated ceramic filters showed a constant permeability without regard to the macro-pore size of the support. The permeabuilities of support varied in the range of 600$\times$10-13m2 to 1000$\times$10-13m2. For the case of coated ceramic filter it was about 200$\times$10-13m2. As a result of particle trapping test by using fly ash the particle removal efficiency was over the 99.9%.

  • PDF