• Title/Summary/Keyword: Particle contaminants

Search Result 85, Processing Time 0.023 seconds

Discussion of Problems During the Application of the On-line Particle Counter In Water Treatment Process (정수처리 공정에서 연속식 입자계수기의 적용성 검토에 관한 연구)

  • Moon, Seong-Yong;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.214-220
    • /
    • 2005
  • Errors may occur due to analysis methods and water quality during the application of the on-line particle counter In water treatment process. Errors caused by analysis methods include particle destruction by shear force due to inflow speed and tube friction, as well as interruption by screening, bubbles and contaminants. Since errors happen frequently because of these factors, it is necessary to examine and evaluate such errors during the application of a particle counter. Errors can be large due to screening and bubbles. Measurement values are effective for water analysis after filtration process. However, because of screening, only measurement values for particles above $7{\mu}m$ are valid for water with a turbidity between 3-10NTU. As particle numbers around $10{\mu}m$ increase a lot after ozone treatment, sufficient pretreatment process is necessary. Physical conditions should keep stable for inflow to decrease errors caused by shear force.

Particle Emission Characteristics and Measurement of Ultrafine Particles from Laser Printer (사무용기기에서 발생되는 미세입자 측정 및 분석방법 연구)

  • Lee, Kyung Hwan;Kim, Sun Man;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.6 no.3
    • /
    • pp.123-129
    • /
    • 2010
  • As the indoor activity increases in recent years, the indoor air quality becomes more important. One of the major contaminants in office space is the copy machines and the laser based printers. These devices usually emit nano-particles and chemical species that may give some health effect. The amount of particles generated by the printers and copy machines depend on printer models, printing speed, toners, papers, humidity and so on. To evaluate the emission rate of nano-particles from Laser Printers, the mass concentration measurement method has been used (BAM, 2004). However, the mass concentration measurement method for nano-particles is tedious and time consuming. Therefore, for the development of a new nano-particle counting method, the nano-particle emission characteristics and size distributions are evaluated.

An Experimental Study on the Effect of Contaminated Lubricants on Wear Characteristics (오염된 윤활유가 마멸특성에 미치는 영향에 관한 실험적 연구)

  • Kim, Hae-Won;Hong, Jae-Hak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.7 no.2
    • /
    • pp.113-123
    • /
    • 1990
  • To study deleterious effects of contaminants contained in lubricating systems, the effects of fine alumina particle concentration and size on the critical failure load, friction and wear characteristic were examined on boundary lubrication condition using the four ball machine. The following conclusions are deduced: The abrasive is found to cause a transition from mild wear to severe wear at less severe conditions than with clean oil. In mild wear region the friction and wear increase with particle size and concentration, but in severe wear region do not exhibit any definite trend. In relation to film thinckness there is a threshold of particle size beyond which the failure load no longer decreases with particle size.

  • PDF

Assessment of Sorption Behavior on Slag Against Heavy Metals (카드뮴, 납, 구리에 대한 슬래그의 흡착특성평가)

  • Lee, Gwang-Hun;Choi, Sung-Dae;Chung, Jae-Shik;Park, Jun-Boum;Nam, Kyoung-Phile
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.6
    • /
    • pp.17-25
    • /
    • 2008
  • Permeable reactive barriers (PRBs) technology can be applied to contaminated groundwater remediation. It is necessary to select adequate reactive material according to contaminant characterization. In groundwater. In this research, the reaction between reactive material and heavy metal contaminants was estimated through batch test. Reactive material was slag, which has been produced in Gwangyang power plant, and heavy metal contaminants were cadmium, lead and copper. Batch test consisted of two testes: 1) sorption equilibrium test and 2) sorption kinetic test. Sorption equilibrium test was performed for estimating slag sorption capacity against contaminants. And sorption kinetic test was performed for slag sorption rate with contaminants species, contaminants initial concentration and sulfate. Sorption capacity and sorption rate were affected by contaminant species. Sorption rate increased with increasing initial concentration in lead and copper but decreased with increasing initial concentration in cadmium. Sorption rate increased in existing sulfate. In low concentration, film diffusion was domain mechanism, and in high concentration, particle diffusion was domain mechanism.

Distribution and Behavior of Mixed Contaminants, Explosives and Heavy Metals, at a Small Scale Military Shooting Range (국내 소규모 군사격장 복합오염물질(화약물질 및 중금속)의 분포 및 거동)

  • Park, Seokhyo;Bae, Bumhan;Kim, Minkyung;Chang, Yoonyoung
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.5
    • /
    • pp.523-532
    • /
    • 2008
  • A phase II site investigation and feasibility study was conducted at a military mortar shooting range near the demilitarized zone (Kyunggi, South Korea) to assess the extent of contaminants migration to the nearby Imjin river in which a flood control dam is under construction. The results showed that silty-clay soils around target areas were co-contaminated with heavy metals (Cd, Cu, and Pb) and explosives (HMX, RDX, and TNT). The total amount of contaminant was estimated to be 497.1 kg-RDX, 20.6 kg-HMX, 1.4 kg-TNT, 35.2 kg-Cd, 4,331 kg-Cu, and 5,115 kg-Pb, respectively. Both heavy metals and explosives were almost equally distributed on each soil particle size fraction. Neither subsurface soil samples nor ground water samples showed signs of contamination above the environmental criteria. The major migration route of contaminants was soil particles in surface run-off during rain at which a mass discharge rate of 30.0 mg-RDX/hour was observed.

Laser decontamination for radioactive contaminated metal surface: A review

  • Qian Wang;Feisen Wang;Chuang Cai;Hui Chen;Fei Ji;Chen Yong;Dasong Liao
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.12-24
    • /
    • 2023
  • With the improvement of laser technology, the strategic needs of efficient and precise decontamination of various components in nuclear application units can be fulfilled by laser decontamination. The surface contaminants of nuclear facilities mainly exist both as loose contaminated layer and fixed oxide layer. The types of radionuclides and contamination layer thickness are closely related to the operation status of nuclear facilities, which have an important influence on the laser decontamination process. This study reviewed the mechanism of laser surface treatment and the influence of laser process parameters on the decontamination thickness, decontamination factor, decontamination efficiency and the distribution of aerosol particle. Although multiple studies have been performed on the mechanism of laser processing and laser decontamination process, there are few studies on the microscopic process mechanism of laser decontamination and the influence of laser decontamination on surface properties. In particular, the interaction between laser and radioactive contaminants needs more research in the future.

A Study On Heavy Metal Contamination in the Different Size Fractions of Deposited Road Particles(DRPs) (노면퇴적물의 입자 크기에 따른 중금속 오염에 관한 연구)

  • Kim, Boo-Gil;Lee, Byung-Cheol
    • Journal of Environmental Science International
    • /
    • v.15 no.12
    • /
    • pp.1171-1175
    • /
    • 2006
  • Deposited road particles (DRPs) were analysed for heavy metal concentrations at four different roads in a city, Korea. The samples were collected using a roadway surface vacuum cleaning vehicle which was commonly used in collecting roadway surface particles. Six particle size ranges were analyzed separately for twelve heavy metal elements (Cd, Cr, Pb, Ni, Al, As, Co, Cu, Fe, Mn, Zn and Hg). At all sampling sites, the high concentration of the heavy metals occurred in the <74um particle size range, which conventional roadway cleaning vehicles do not remove efficiently. The Pb concentration significantly increased with decreasing particle size of DRPs, and other toxic heavy metals (Cd, Cr and Ni) also showed similar results. The heavy metal concentrations in the smaller size fraction of DRPs is important because they are contaminants that are preferentially transported by road runoff during rainfall.

Evaluation of Particle Removal Efficiency during Jet Spray and Megasonic Cleaning for Aluminum Coated Wafers

  • Choi, Hoomi;Min, Jaewon;Kulkarni, Atul;Ahn, Youngki;Kim, Taesung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.3
    • /
    • pp.7-11
    • /
    • 2012
  • Among various wet cleaning methods, megasonic and jet spray gained their popularity in single wafer cleaning process for the efficient removal of particulate contaminants from the wafer surface. In the present study, we evaluated these two cleaning methods for particle removal efficiency (PRE) and pattern damage on the aluminum layered wafer surface. Also the effect of $CO_2$ dissolved water in jet spray cleaning is assessed by measuring PRE. It is observed that the jet spray cleaning process is more effective in terms of PRE and pattern damage compared to megasonic cleaning and the mixing of $CO_2$ in the water during jet sprays further increases the PRE. We believe that the outcome of the present study is useful for the semiconductor cleaning process engineers and researchers.

Recycling of Wastepaper(Ⅶ)-The Effect of Stock Composition on Enzyme Activity- (고지재생연구(제 7보)-지료조성이 효소활성에 미치는 영향-)

  • 여성국;류정용;신종호;송봉근;오세균
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.31 no.3
    • /
    • pp.1-9
    • /
    • 1999
  • Effect of furnish on enzyme activity was investigated by using the three components (cellulose, enzyme, and cationic polyelectrolyte) model papermaking system. Avicel was used as a cellulose model compound to observe the effect of adsorption and desorption of enzyme with other component and the resultant change of particle size. As an experimental result, the enzyme loses considerably its apparent activity due to the adsorption onto cellulose and cationic polyelectrolyte. Activities of enzyme applied to the actual papermaking stocks having controlled fiber length showed different behavior in terms of pulp species UKP and KOCC stocks. That is, the enzyme activity in UKP was increased as fines content increased, however, vice versa in KOCC stock . This result can be considered to be the existence of various contaminants included in the fines of KOCC . The effect of possible contaminants such as inorganic materials, calcium ion, surfactant, and conductivity on enzyme activity were also investigated.

  • PDF

High resolution size characterization of particulate contaminants for radioactive metal waste treatment

  • Lee, Min-Ho;Yang, Wonseok;Chae, Nakkyu;Choi, Sungyeol
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2277-2288
    • /
    • 2021
  • To regulate the safety protocols in nuclear facilities, radioactive aerosols have been extensively researched to understand their health impacts. However, most measured particle-size distributions remain at low resolutions, with the particle sizes ranging from nanometer to micrometer. This study combines the high-resolution detection of 500 size classes, ranging from 6 nm to 10 ㎛, for aerodynamic diameter distributions, with a regional lung deposition calculation. We applied the new approach to characterize particle-size distributions of aerosols generated during the plasma arc cutting of simulated non-radioactive steel alloy wastes. The high-resolution measured data were used to calculate the deposition ratios of the aerosols in different lung regions. The deposition ratios in the alveolar sacs contained the dominant particle sizes ranging from 0.01 to 0.1 ㎛. We determined the distribution of various metals using different vapor pressures of the alloying components and analyzed the uncertainties of lung deposition calculations using the low-resolution aerodynamic diameter data simultaneously. In high-resolution data, the changes in aerosols that can penetrate the blood system were better captured, correcting their potential risks by a maximum of 42%. The combined calculations can aid the enhancement of high-resolution measuring equipment to effectively manage radiation safety in nuclear facilities.