• 제목/요약/키워드: Particle Tracking Velocimetry

검색결과 72건 처리시간 0.024초

적응형 하이브리드 기법을 이용한 2-Frame PTV 기법의 성능향상 연구 (Performance Improvement of 2-Frame PTV Method Using an Adaptive Hybrid Scheme)

  • 김형범;이상준
    • 대한기계학회논문집B
    • /
    • 제24권3호
    • /
    • pp.443-449
    • /
    • 2000
  • The performance of 2-frame PTV(particle tracking velocimetry) system was improved using an adaptive hybrid scheme. The original 2-frame PTV method based on the match probability concept employs global match parameters for the entire flow field. Since this does not reflect fully the detailed local velocity change, it sometimes reduces the recovery rate of velocity vectors and increases the number of erroneous vectors in the region where an extraordinary flow structure exists. In this study, the preliminary FFT-based PIV results are used as an input parameter to determine the local match parameters needed for the 2-frame particle tracking algorithm. A computer simulation using synthetic particle images was carried out to study the performance of the adaptive 2-frame PTV technique. The adaptive hybrid method shows the better performance with increasing the velocity vector recovery rate and decreasing the computation time, compared to the original 2-frame PTV method.

유사 흐름 측정을 위한 입자추적유속계 알고리듬의 개발 (Development of a PTV Algorithm for Measuring Sediment-Laden Flows)

  • 류권규;마리안 머스테;로버트 에테마;윤병만
    • 한국수자원학회논문집
    • /
    • 제38권10호
    • /
    • pp.841-849
    • /
    • 2005
  • 유사 입자가 포함된 흐름이나 공기 방울이 포함된 흐름과 같은 이상류 (two-phase flow) 는 유체의 속도와 입자의 속도와 같은 두 가지 서로 다른 속도 분포가 존재한다. 이러한 이상류의 속도장 분석을 위해서는 두 가지 속도 분포를 별도로 측정할 수 있는 기법을 이용해야 한다. 공기 방울이 포함된 흐름에 대해서는 입자영상 유속계(PIV)나 입자추적유속계(PTV)를 이용하여 비교적 타당한 정도로 유속 분포를 측정하여 왔다. 그러나 자연 모래를 포함한 흐름 영상의 속도 분포 해석에서는 PIV나 PTV가 그다지 성공적이지 못했는데, 그것은 흐름 중에 있는 유사 입자가 영상을 해석하기 어렵게 만들기 때문이다. 유사 흐름의 속도 분석을 위해 다양한 영상 분석 기법을 결합한 방법을 제시하였다. 입자 추출 알고리듬으로 역치값, 경계 추출 알고리듬, 세선화 알고리듬을 조합한 새로운 방법을 제안하였다. 또한 입자의 이동 변위 계산을 위해서 PIV와 PTV를 조합한 새로운 방법을 개발하였다. 이 새로운 알고리듬은 다음과 같은 기능을 가지고 있다. (1) 새알고리듬은 유사 입자, 특히 자연 모래와 같이 불규칙한 형태를 갖는 입자의 경계를 정확히 찾아낼 수 있다. (2) 필요한 정보를 잃어버리지 않고, 반사광이나 난반사에 의한 영상을 효율적으로 제거할 수 있다. (3) 추적 입자가 유사입자 가까이에 있어 유사의 난반사 영역이 들어 있어도 이를 분리해 낼 수 있다.

2-프레임 PTV 시스템의 개발 및 채널유동에의 응용 (Development of 2-frame PTV system and its application to a channel flow)

  • 백승조;이상준
    • 대한기계학회논문집B
    • /
    • 제22권6호
    • /
    • pp.874-887
    • /
    • 1998
  • A 2-frame PTV (particle tracking velocimetry) system using the concept of match probability between two consequent image frames has been developed to obtain instantaneous velocity fields. The overall 2-frame PTV system including image pre-processing, tracking algorithm and post-processing routine was implemented to apply to real flows. The developed 2-frame PTV system has several advantages such as high recovery ratio of velocity vectors, low error ratio and small computational time compared with the conventional 4-frame PTV and the FFT-based cross-correlation PIV technique. The 2-frame PTV system was applied to a turbulent channel flow over a rectangular block to check its reliability and usefulness. Total 96 sequential image frames have been captured and processed to get both mean and fluctuating velocity vector fields over the recirculating region. The mean velocity and turbulent intensity profiles were well agreed with hte LDV measurements in the separated region behind the block. Time-averaged reattachment length is about 6.3 times of the block height.

Flow Characteristics of Neutrally Buoyant Particles in 2-Dimensional Poiseuille Flow through Circular Capillaries

  • Kim, Young-Won;Jin, Song-Wan;Yoo, Jung-Yul
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.7-10
    • /
    • 2006
  • An experimental study has been conducted to quantitatively characterize the motion of neutrally buoyant particles in 2-dimensional Poiseuille flow through the micron-sized circular capillaries in the range of Re (Reynolds number) $\approx0.1\sim100$. $A{\mu}-PTV$ (Particle Tracking Velocimetry) system is adopted, which consists of a double-headed Nd:YAG laser, an epi-fluorescence microscope and a cooled CCD camera. Since high shear rate can be induced due to the scale effect even at low Re, it is shown that in micro scale neutrally buoyant particles in Poiseuille flow drift away from the wall and away from the center of the capillary. Consequently, particles accumulate at the equilibrium position of $0.52\sim0.64R$ with R being the radius of the capillary, which is analogous to that of tube flow in macro scale. There is a plateau in equilibrium position at small Re, while equilibrium position starts increasing at $Re\approx30$. The outermost edge of particle cluster is closer to the center of the capillary than that in previous studies due to low Re effect. The present study quantitatively presents characteristics of particle motion in circular capillaries. Furthermore, it is expected to give optimum factors for designing microfluidic systems that are to be used fur plasma separation from the blood.

  • PDF

Taylor-G$\ddot{o}$rtler-Like(TGL)와의 거동특성에 관한 연구 (A Study on the Behavior Characteristics of TGL Vortex)

  • 이영호;김춘식;조대환;최장운
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권4호
    • /
    • pp.28-37
    • /
    • 1993
  • Flow characteristics within the three-dimensional square cavity are studied experimentally by adopting PIV(Particle Image Velocimetry). A new method for tracking the same particle pairs in the consecutive flow image is suggested resulting in more effective acquisition of the velocity vectors. Two methods for supplying the shearing stress within the cavity are developed by continuous moving belt and 2-dimensional plane Poiseuille flow. The effect of TGL vortex in the case of belt-moving flow is remarkable owing to the distribution of the kinetic energy in the spanwise direction. But, for the plane Poiseuille flow, velocity profiles similar to a forced vortex are obtained and its tendency increases with the Reynolds number.

  • PDF

PIV 가시화에 의한 합류덕트에서의 유동특성 (Flow Characteristics for PIV Visualization at Junction Duct)

  • 김명관;권오붕;배대석
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.45-50
    • /
    • 2005
  • Characteristics of flows at T-junction duct with and without orifices are investigated in this paper. Experiments and PIV visualization were carried out for several flow rates. Two-dimensional PIV experimental apparatus was decided by numerical analysis. PIV visualization was also coded to visualize flow fields at junctions for two-dimensional case. For the PIV visualization system, Grey-Level Cross-Correlation particle tracking algorithm was used to calculate the flow fields. Vinyl chloride polymer particles of $100{\sim}150{\mu}m$ of diameter are used in this visualization. The PIV visualization results showed relatively good agreement with Experimental data.

  • PDF

3차원 동시 PIV, PTV를 활용한 난류가 관성 입자의 거동에 미치는 영향 분석 (Analysis of the effect of turbulence on the motion of inertial particle using 3D simultaneous PIV,PTV)

  • 박형철;황진환
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.281-281
    • /
    • 2022
  • 바닥에서 생성되는 난류는 순간적으로 강한 모멘텀을 바닥에 전달함과 동시에 바닥에 있는 입자를 움직이게 한다. 경계층 내 난류 운동에 대한 분석은 다양한 유사 이송 문제를 이해하기 위해 필수적이며 이에 따라 많은 선행 연구들은 실험실 실험을 통해 해당 연구를 수행하였다. 본 연구에서는 선행 연구에서 사용하지 못했던 진보된 실험 방법을 활용하여 바닥 경계층 내의 난류 운동에 대해 확인하고 해당 운동에 의해 관성 입자의 움직임이 어떻게 발생하는지에 대하여 물리적으로 설명하고자 한다. 다양한 흐름 조건에서 3가지의 입경 크기를 가지는 모래 입자를 가지고 실험을 수행하였으며, 실험 조건별 고해상도 유속장 및 관성 입자의 움직임은 3차원 입자 영상 유속계 (Particle Image Velocimetry; 이하 PIV)와 입자 추적 유속계 (Particle Tracking Velocimetry; 이하 PTV)를 동시에 적용하여 파악하였다. 취득된 3차원 유속장과 입자 궤적을 기반으로 실험 조건별 흐름 및 입자 거동 특성에 대해 분석하였으며, 관성 입자의 움직임을 발생시키는 3차원 난류 운동은 측정된 유속장에서 산정한 Q-criterion 값을 기반으로 도식화하였다. 측정값 내에는 난류 운동에 대한 정보와 더불어 잡음이 포함되어 있으므로 이를 제거하고자 적합 직교 분해 (Proper Orthogonal Decomposition; 이하 POD) 방법을 적용하였다. 그리고 POD로 추출한 유속장을 통해 바닥면 부근에 존재하는 헤어핀 와류 운동 혹은 와류 묶음과 같은 난류 고유 구조를 파악하였다. 해당 와류 운동들의 3차원 난류 특성을 확인하고자 비등방성 불변 지도(anisotropy invariant map)를 활용하였으며 경계층 내부에서 난류의 형태가 흐름 방향으로 늘어진 럭비공 형태임을 확인하였다. 마지막으로, 입자의 움직임을 발생시키는 난류 이벤트를 결정하고자 사방구 분석 (Quadrant analysis) 기법을 적용하였으며 흐름 조건별로 입자를 움직이게 하는 난류 이벤트는 달라짐을 확인하였다.

  • PDF

와추적 위상평균 기법을 이용한 원주후류의 PIV측정 (PIV Measurement of Circular Cylinder Wake Using Vortex Tracking Phase-Average Technique)

  • 김경천;윤상열;김상기;부정숙
    • 대한기계학회논문집B
    • /
    • 제25권7호
    • /
    • pp.915-922
    • /
    • 2001
  • A new phase-average technique using instantaneous velocity fields obtained by a PIV method has been developed. The technique tracks vorticity centers and estimates the value of circulation for a chosen domain. The locations of vortex-centers and the magnitudes of circulation are matched together then showing a sine wave feature due to the periodic vortex shedding from the circular cylinder. Ensemble averaged and phase averaged velocity fields are successfully measured for the circular cylinder wake where Reynolds number is 3900 based on free stream velocity and cylinder diameter. The convection velocities of the vortices center and the vortex shedding frequency were measured by a single hot-wire probe.

Micro-PIV Measurements of In Vitro Blood Flow in a Micro-Channel

  • Park, Cheol-Woo;Lee, Sang-Joon;Shin, Se-Hyun
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제1권2호
    • /
    • pp.30-35
    • /
    • 2003
  • Flow characteristics of blood flow in a micro channel were investigated experimentally using a micro-PIV (Particle Image Velocimetry) velocity field measurement technique. The main objective of this study was to understand the real blood flow in micron-sized blood vessels. The Reynolds number based on the hydraulic diameter of micro-channel for deionized (DI) water was about Re=0.34. For each experimental condition, 100 instantaneous velocity fields were captured and ensemble-averaged to get the spatial distributions of mean velocity. In addition, the motion of RBC (Red Blood Cell) was visualized with a high-speed CCD camera. The captured flow images of nano-scale fluorescent tracer particles in DI water were clear and gave good velocity tracking-ability. However, there were substantial velocity variations in the central region of real blood flow in a micro-channel due to the presence of red blood cells.

  • PDF

다공성 방풍벽 뒤에 놓인 삼각 프리즘 주위 유동의 PTV 속도장 측정 (PTV velocity field measurements of flow around a triangular prism located behind a porous fence)

  • 김형범;이상준
    • 대한기계학회논문집B
    • /
    • 제22권5호
    • /
    • pp.708-715
    • /
    • 1998
  • The shelter effect of a porous wind fence on a triangular prism was experimentally investigated in a circulating water channel. A porous fence of porosity .epsilon.=38.5% was installed in front of the prism model. The fence and prism model were embedded in a turbulent boundary layer. The instantaneous velocity fields around the fence and prism model were measured by using the instantaneous velocity fields around the fence and prism model were measured by using the 2-frame PTV(Particle Tracking Velocimetry) system. By installing the fence in front of the prism, the recirculation flow region decreases compared with that of no fence case. The porous fence also decreases the mean velocity, turbulent intensity and turbulent kinetic energy around the prism. Especially, at the top of the prism, the turbulent kinetic energy is about half of that without the fence.