• 제목/요약/키워드: Particle Counter

검색결과 211건 처리시간 0.022초

VACES을 이용한 대기 중 입자상물질의 농축기술 및 특성 연구 (Characteristics of Aerosol Particle Concentration by the Versatile Aerosol Concentration Enrichment System (VACES))

  • 박정호
    • 한국환경과학회지
    • /
    • 제21권11호
    • /
    • pp.1339-1348
    • /
    • 2012
  • The versatile aerosol concentration enrichment system (VACES) have proven useful for providing elevated levels of atmospheric aerosol to human and animal exposures. In this study, we describe a VACES and tests conducted to both optimize the enhancement factor (EF) and characterize how it depends on experiment conditions. Particle number concentrations were measured from upstream and downstream of the system by scanning mobility particle sizer (SMPS) with a long differential mobility analyzer (DMA) in combination with a condensation particle counter (CPC). SMPS was used for to determine VACES particle EF. Particle EF tends to increase for higher the saturator temperature ($T_{Sat}$) and lower the condenser temperature ($T_{Con}$). $T_{Con}$ higher than $0^{\circ}C$ and $T_{Sat}$ lower than $50^{\circ}C$ was the best to obtain the most increase in particle concentration. Correlation analysis of EF with factor variables of $T_{Sat}$ and $T_{Con}$ resulted in correlation 0.662 and 0.416, respectively. With all five predictor variables included in a multiple regression model, the EF had a liner correlation with $R^2=0.643$.

하드디스크 드라이브에서 Smooth 디스크와 LZT 디스크가 입자 발생에 미치는 영향 (Effects of Smooth and Textured Disks on Particle Generation in a Hard Disk Drive)

  • 이대영;허선영;강필선;황정호;조긍연;강태식
    • 정보저장시스템학회:학술대회논문집
    • /
    • 정보저장시스템학회 2005년도 추계학술대회 논문집
    • /
    • pp.88-95
    • /
    • 2005
  • The head to disk spacing must be decreased to increase recording densities in hard disk drives. Recently, to decrease the head to disk spacing, smooth disk having no bumps onto the lading zone has used. In this research, we compared the number of particles generated in HDD with smooth and textured disks. We used a sampling method using a particle sampler and a CPC (condensation particle counter) to detect particles in HDD. First, we sampled and counted panicles generated with disk rotational speed and various rest times when the smooth disk and textured disks were used, then analyzed the sampled particles by SEM (scanning electron microscopy) and AES (auger electron spectroscopy). In results of measuring particles, more particles in case of LZT disk drive generated than that of the smooth disk drive in all test modes. The number of particles generated in the smooth disk was very low. The particle generation increased as the rest time increased (smooth/LZT disks) and more particles in case of LZT disk drive generated than that of the smooth disk drive. In results of analyzing particle components, Al, Ti, Si components were detected and we could not found differences between components in case of smooth/LZT disk drive.

  • PDF

하드 디스크 드라이브에서 Smooth 디스크와 LZT 디스크가 입자 발생에 미치는 영향 (Effects of Smooth and Textured Disks on Particle Generation in a Hard Disk Drive)

  • 이대영;허선영;강필선;황정호;조긍연;강태식
    • 정보저장시스템학회논문집
    • /
    • 제2권2호
    • /
    • pp.123-129
    • /
    • 2006
  • The head to disk spacing must be decreased to increase recording densities in hard disk drives. Recently, to decrease the head to disk spacing, smooth disk having no bumps onto the lading zone has used. In this research, we compared the number of particles generated ill HDD with smooth and textured disks. We used a sampling method using a particle sampler and a CPC (condensation particle counter) to detect particles in HDD. First, we sampled and counted particles generated with disk rotational speed and various rest times when the smooth disk and textured disks were used, then analyzed the sampled particles by SEM (scanning electron microscopy) and AES (auger electron spectroscopy). In results of measuring particles, more particles in case of LZT disk drive generated than that of the smooth disk drive in all test modes. The number of particles generated in the smooth disk was very low. The particle generation increased as the rest time increased (smooth/LZT disks) and more particles in case of LZT disk drive generated than that of the smooth disk drive. In results of analyzing particle components, Al, Ti, Si components were detected and we could not found differences between components in case of smooth/LZT disk drive.

  • PDF

OPC(광학적 입자 계수기)로 측정한 2001년 서울지역 에어로졸의 입경 분포 (Characteristics of Aerosol Size Distribution from OPC Measurement in Seoul, 2001)

  • 정창훈;전영신;최병철
    • 한국대기환경학회지
    • /
    • 제19권5호
    • /
    • pp.515-528
    • /
    • 2003
  • The characteristics of one year observation aerosol data in Seoul, 200 I was studied using an OPC (Optical Particle Counter). The size resolved aerosol number concentrations of 0.3 ∼ 25 11m were measured. The results were compared with PM$_{10}$ mass concentration data under various meteorological conditions including dust and precipitation events. For fine particles whose diameter is less than 2.23 ${\mu}{\textrm}{m}$, the number concentration increases in the early morning which is considered due to transportation. while the coarse mode particles increase during daytime. This increase can be explained as local sources and human activities near sampling site. Hourly averaged data show that there exists diurnal variation. Generally, PM$_{10}$ data showed a similar tendency with OPC data. The size resolved OPC data showed that the particles of 0.5 ∼ 3.67 ${\mu}{\textrm}{m}$ are positively correlated with PM$_{10}$ data. The accumulated volume fraction of size resolved aerosol concentration in 0.5 ∼ 10 ${\mu}{\textrm}{m}$ showed that 0.5 ∼ 2.23 ${\mu}{\textrm}{m}$ particles occupied 59.2% of total aerosol volume of 0.5 ∼ 10 ${\mu}{\textrm}{m}$./TEX>.

측정 방법에 따른 PM2.5 농도 비교 (Comparison of PM2.5 Concentrations by Measurement Method)

  • 김영성;최용주;박지수;김필호;한유경
    • 한국대기환경학회지
    • /
    • 제33권5호
    • /
    • pp.515-520
    • /
    • 2017
  • $PM_{2.5}$ concentrations were measured using a cyclone, impactor (the U.S. Environmental Protection Agency well impactor ninety-six, WINS) and optical particle counter (OPC) at a campus site located in Yongin for the period August 2014 through March 2017. The concentrations from cyclone (Y) were generally higher than those from impactor(X); the best-fit line was Y=1.22X+5.64. The ratios of $PM_{2.5}/PM_{10}$ ranged from 0.61 to 0.66 when $PM_{2.5}$ concentrations from cyclones in selected studies were converted into those from impactors using a regression equation in this study. The slope of the best-fit line between OPC and impactor was close to 1 at 0.95, while that between OPC and cyclone was 0.72. After sampling, the flow rate in the low-volume air sampler with cyclone decreased by 3% on average, which did not have a significant effect on measured concentrations.

이중공기공급 속도비에 따른 이류체 선회분무 특성 연구 (A Study of Two-Phase Swirl Spray Characteristics on Dual Airblast Velocity Ratio)

  • 강신재;오제하;송기정;노병준
    • 한국분무공학회지
    • /
    • 제5권3호
    • /
    • pp.27-36
    • /
    • 2000
  • In this study, spray characteristics of a dual airblast atomizer are addressed. Three dimensional characteristics of a dual airblast atomizer with air swirl are measured to provide the significant data. The liquid flow rate was fixed at 0.06 kg/min, and atomizing air was controlled at the liquid-air mass ratio of 4.0. The performance of the spray with co-swirl and counter-swirl flow was investigated at each point in the developed spray region using a three-component phase Doppler particle analyzer. This instrument was also used to evaluate the concentration profiles. The three dimensional mean velocity were investigated of present flow characteristics of the dual airblast atomizer. In addition, drop size distributions, mean droplet size profile, and droplet concentration were analyzed to understand atomization characteristics. This experimental results can be conveniently utilized for the preliminary design of gas turbine engines for aircraft.

  • PDF

TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109, HCT Particle Sensor 3030을 이용한 PM2.5 측정결과 비교 (Comparison Study of the TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109 and HCT Particle Sensor 3030 for PM2.5 measurement)

  • 김두용;정혁;박재홍;현준호;황정호
    • 한국입자에어로졸학회지
    • /
    • 제8권1호
    • /
    • pp.9-15
    • /
    • 2012
  • Three different commercial particle counters were used to measure the PM2.5 particles in this study. An Aerosol Spectrometer (AS) 1.109 model of Grimm and a Particle Sensor (PS) 3030 model of HCT were compared with an Aerodynamic Particle Sizer (APS) 3321 model of TSI. The responses of these instruments were compared for four sizes ($1.0{\mu}m$, $1.5{\mu}m$, $2.0{\mu}m$ and $2.5{\mu}m$) of polystyrene latex (PSL) particles and indoor air particles of the office room. The mode diameter, particle size distribution and total particle number concentration of PSL particles were measured by each instrument. In the office room, the total particle number concentration was measured for 25 minutes. In results of particle size distribution and mode diameter, the APS 3321 (52 size-channels) was more accurate than the AS 1.109 (31 size-channels) and PS-3030 (10-szie channels) since the APS has more number of size-channels than the other instruments. However, AS 1.109 and PS-3030 provided similar results of total particle number concentration to those from the APS 3321. In results of office room test, there were no significant difference from each instrument similar to results of PSL test.

석탄연소 보일러에서 생성된 석탄회의 분석과 형성 메커니즘 해석에 대한 연구 (A Study on the Formation Mechanism of the Fly Ash from Coal Particles in the Coal Burning Boiler)

  • 이정언;이재근
    • 대한기계학회논문집B
    • /
    • 제22권12호
    • /
    • pp.1691-1701
    • /
    • 1998
  • Fly ash produced in coal combustion is a fine-grained material consisting mostly of spherical, glassy, and porous particles. A study on the formation mechanism of the fly ash from coal particles in the pulverized coal power plant is investigated with a physical, morphological, and chemical characteristic analysis of fly ash collected from the Samchonpo power plant. This study may contribute to the data base of domestic fly ash, the improvement of combustion efficiency, fouling phenomena and ash collection in the electrostatic precipitator. The physical property of fly ash is determined using a particle counter for the measurement of ash size distribution. Morphological characteristic of fly ash is performed using a scanning electron micrograph. The chemical components of fly ash are determined using an inductively coupled plasma emission spectrometry(ICP). The distribution of fly ash size was bi-modal and ranged from 12 to $19{\mu}m$ in mass median diameter. Exposure conditions of flue gas temperature and duration within the combustion zone of the boiler played an important role on the morphological properties of the fly ash such as shape, particle size and chemical components. The evolution of ash formation during pulverized coal combustion has revealed three major mechanisms by large particle formation due to break-up process, gas to particle conversion and growth by coagulation and agglomeration.