• Title/Summary/Keyword: Particle Bed

Search Result 434, Processing Time 0.027 seconds

Application of Intra-particle Combustion Model for Iron Ore Sintering Bed (제철 소결공정에 대한 단입자 연소 모델의 응용)

  • Yang, Won;Choi, Sang-Min;Jin, Hong-Jong
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.181-188
    • /
    • 2006
  • Operation parameters for large scale industrial facility such as iron making plant are carefully selected through elaborate tests and monitoring rather than through a mathematical modeling. One of the recent progresses for better energy utilization in iron ore sintering process is the distribution pattern of fuel inside a macro particle which is formed with fines of iron ore, coke and limestone. Results of model tests which have been used as a basis for the improved operation in the field are introduced and a theoretical modeling study is presented to supplement the experiment-based approach with fundamental arguments of physical modeling, which enables predictive computation beyond the limited region of tests and adjustment. A single fuel particle model along with one-dimensional bed combustion model of solid particles are utilized, and thermal processes of combustion and heat transfer are found to be dominant consideration in the discussions of productivity and energy utilization in the sintering process.

  • PDF

An Experimental study on Heat Characteristics of Horizontal Tubes with Fin in Fluidized Bed Combustor (유동층 연소로 내에서 수평 휜 전열관의 열전달 특성에 관한 실험적 연구)

  • Kang, Hyung-Soo;Chung, Tae-Yong
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.1
    • /
    • pp.19-29
    • /
    • 1996
  • This study is to investigate the characteristics of heat transfer of a horizontal tube, with radial fins of various configuration, immersed in a high temperature fluidized bed. The experimental heat transfer variation is compared with that of a smooth tube. The finned tubes and smooth tube, with outside and inside diameter of 48.6mm and 30.6mm, are made of steel tubes. The depth of the fin is 5mm, the rake angles of fin are $25^{\circ},\;35^{\circ},\;45^{\circ}$ and the widthes of fin for each rake angle are 0mm, 1mm, 2mm and 3mm. A bed temperature is fixed at $880\;{\pm}\;10^{\circ}C$. A granular refractory(silica sand) is used as a bed material with mean particle diameters of 1.22mm and 1.54mm. The maximum heat transfer coefficient is achieved with the rake angle of $25^{\circ}$ and the width of 0mm for the mean particle size 1.22mm. The coefficient is 2.14 times larger than that for a smooth tube. The rake angle for the maximum heat transfer coefficient depends on the particle size of bed material. Also the transfer coefficient decreases as the width of fin increases.

  • PDF

Analysis of Breakthrough Curves and Mass Transfer Resistance for Phenol Adsorption in a Fixed-bed Process Packed with Activated Carbon (활성탄을 충전한 고정층에서 페놀 흡착에 따른 파과곡선과 물질전달저항 해석)

  • You, Hae-Na;Kam, Sang-Kyu;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.23 no.1
    • /
    • pp.53-60
    • /
    • 2014
  • Adsorption of phenol on activated carbon in a fixed bed was studied. The effects of fixed-bed length, superficial velocity (flow rate) and particle size of adsorbent on fixed-bed performance were investigated. Some characteristic parameters such as the breakthrough time ($t_{0.05}$), saturation time ($t_{0.95}$), length of mass transfer zone ($L_{MTZ}$), adsorptive capacity (W), and adsorption rate constant ($K_a$) were derived from the breakthrough curves. Adsorbent particle sizes significantly affected the shape of the breakthrough curve. Larger particle sizes resulted in an earlier breakthrough, a longer $L_{MTZ}$ and a lower adsorption rate. Superficial velocity was a critical factor for the external mass transfer during fixed-bed adsorption process. The external mass transfer resistance was dominant as increasing superficial velocity.

Effects of Particle Concentrations on Friction Factors and Pressure Drops in a Horizontal Pipe (수평 관에서 고체입자 농도가 압력강하 및 마찰계수에 미치는 효과)

  • Ahn, S.W.;Lee, B.C.;Kang, H.K.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.44-49
    • /
    • 2007
  • Generally, the economic concept of optimized design and operating conditions in fluidized bed heat exchangers can hardly be realized. Because the lack of fundamental knowledge about the particle flows, the optimum design of the fluidized bed heat exchanger is rather limited. In the present work, measurements are made on pressure drops and friction factors in the horizontal circular tube with solid particles in the circulating water. Two different solid particles of diameters of 3mm and 4mm are covered. The Reynolds numbers are ranged from 10,000 to 45,000. It is concluded that the friction factors for the particles of 4mm diameter are much higher than those for the particles of 3mm diameter. And at the lower particle concentration, the friction factors are strongly influenced by the fluid velocity rather than the particle concentration; However, the effect of the particle concentration on friction factors is also significantly higher at a higher particle concentration operating condition.

  • PDF

Chemical Looping Combustion Characteristics of Coal and Char in a Batch Type Fluidized Bed Reactor (회분식 유동층 반응기에서 석탄과 촤의 매체순환연소 특성)

  • Ryu, Ho-Jung;Hyun, Ju-Soo;Kim, Young-Joo;Park, Yeong-Seong;Park, Moon-Hee
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.6
    • /
    • pp.884-894
    • /
    • 2011
  • Effects of temperature, volatile content, particle diameter and solid input weight were investigated in the batch fluidized bed reactor using OCN703-1100 particle as oxygen carrier and Roto coal and char as fuels. Two solid fuels represented the best reactivity at different temperature, $900^{\circ}C$ for Roto coal and $950^{\circ}C$ for char, respectively. However, we selected $900^{\circ}C$ as the best operating temperature because the improvement of reactivity of char at $950^{\circ}C$ was negligible. Char represented better reactivity than Roto coal because char contains low volatile than Roto coal. For both solid fuels, reactivities were improved with increasing of the particle diameter. These results were explained by solid mixing tests in a transparent fluidized bed using two char particles having different particle size ranges and OCN703-1100 particle. The bigger particle showed better solid mixing with OCN703-1100 particle, and therefore, represented better reactivity. For both solid fuels, reactivities were improved with increasing of the solid input weight within the experimental conditions of this study because the weight of coarse particles increased with the solid input weight increased, and therefore, these coarse particles can mix well with the oxygen carrier.

Treatment of Heavy Metal Wastewater Bed Electrode Reactor by a Fluidized 1. Distribution of Local Mass Transfer Coefficients on the Current Feeder (유동층 전극반응기를 이용한 중금속폐수의 처리에 관한 연구 1. 전류공급원에서의 국부물질전달계수의 분포)

  • 황영기;정은혁
    • Journal of Environmental Science International
    • /
    • v.6 no.1
    • /
    • pp.1-8
    • /
    • 1997
  • Varing the flow velocity of solution and particle diameter, the mass transfer coefficient of the local electrode on current feeder has been measured in an empty flow reactor, an inert fluidized bed electrode reactor, and an active fluidized bed electrode reactor. It had its maximium value when the bed porosity was 0.6 to 0.65 and decreased with in- creasing the height of local electrode. The mass transfer coefficient was found to be high especially when higher particle was fluidized. Electrochemical deposition of copper dissolved in the synthesized wastewater has been performed in the active fluidized bed electrode reactor. The deduction rate was higher than 90% and the residual concentration of copper decreased to less than 5ppm.

  • PDF

Development of a Particle Bed Heat Exchanger (III) -An Experimental Study on Pressure Drop in Fixed Bed Heat Exchanger (입자층(粒子層)을 이용한 열교환기(熱交換器) 개발(開發)에 관한 연구(硏究)(III) -고정층(固定層) 열교환기(熱交換器) 내(內)에서의 압력손실(壓力損失)에 관(關)한 연구(硏究))

  • Yang, H.J.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.226-233
    • /
    • 1990
  • Fixed bed is known to be an effective heat transfer augmentation device which could be applied to heat exchangers. In this study, pressure drop in vertical cylindrical and annular fixed beds with air flowing through was experimentally investigated. Based on the experimental data and some analytical considerations, the demensionless correlation of pressure drop has been determined and shown in empirical forms. In particular, the experimental equation for the pressure drop was derived using the particle diameter and the bed diameter as variables, which would be more practical and useful in the design of heat transfer devices, instead of void fraction which had been used previously as the major variables by others. The present empirical equation obtained for the cylindrical fixed bed were found to be applicable also to an annular fixed bed when the concept of effective diameter was introduced.

  • PDF

Measurement of Effective Thermal Conductivity in Silica Gel Packed Bed (실리카겔 충전층에서의 유효열전도율 측정)

  • Kwon Oh-Kyung;Yun Jae-Ho;Kim Joung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1126-1133
    • /
    • 2004
  • This paper presents an experimental measurement of effective thermal conductivity in an adsorbent packed bed with silica gel A type. The effective thermal conductivity was measured under different conditions of the adsorbent bed temperature, pressure, particle size and water content by using the transient hot wire method. The measured effective thermal conductivity showed to become bigger with decreasing particle size or increasing water content, but it was a little affected with increasing bed temperature and pressure. The bed temperature was varied in the range of 1$0^{\circ}C$ (equation omitted) T (equation omitted) 5$0^{\circ}C$ and the pressure in the range of 10 kPa (equation omitted) P (equation omitted) 190 kPa. The results show that 0.10~0.18 W/mㆍK of effective thermal conductivity measured for the zero water content.

New Expanded Bed Adsorption for Purification of Bovine Serum Albumin

  • Hu, Hong-Bo;Yao, Shan-Jing;Zhu, Zi-Qiang;Hur, Byung-Ki
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.5
    • /
    • pp.776-780
    • /
    • 2001
  • Based on the static and dynamic adsorption of Streamline DEAE, a modified tank-in-series model including particle size distribution was used to describe the adsorption performance of bovine serum albumin in an expanded bed. The calculated results indicated that the suggested model was able to simulate breakthrough curves under various conditions.

  • PDF

Modeling Approach of Solid Particle Bed for the Combustion Environment Control (고체 입자 베드 내 반응 환경 변화를 위한 모델링 접근 방법)

  • Ahn, Hyungjun;Choi, Sangmin
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.21-23
    • /
    • 2013
  • Various solid particle materials are treated in the industrial processes including fixed-beds or moving grate beds, and modeling approaches have been widely applied to the processes to predict and evaluate their performance. For this study, the modeling approach was applied to iron ore sintering process with various improvement measures. Based on the previous modeling approach, the changes and effects of the improvement measures were discussed at the point of controlling the combustion environment in the bed.

  • PDF