• 제목/요약/키워드: Partial prosthesis

검색결과 196건 처리시간 0.024초

편측 후방 치아 잔존시 의치 설계에 따른 지대치지지 조직과 잔존 치조제의 응력 분석에 관한 연구 (STRESS ANALYSIS AT SUPPORTING TISSUE OF ABUTMENT TEETH AND RESIDUAL RIDGE ACCORDING TO DENTURE DESIGN WITH REMAINING UNILATERAL POSTERIOR TEETH)

  • 안광호;정영완;진태호
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.185-199
    • /
    • 1999
  • This study was peformed to investigate the distribution and magnitude of stress at supporting tissue of abutment teeth and residual ridge tissue with remaining unilateral posterior teeth. Four types of removable partial dentures that included clasp retained removable partial denture, attachment retained removable partial denture, telescopic removable partial denture, and swing-lock partial denture were designed, and strain gauge was used for stress analysis. Each prosthesis was subjected to simulated vertical and oblique load. The following conclusions were drawn from this study. 1. The clasp retained removable partial denture generally distributed simulated vertical force more evenly to the supporting structure. 2. The stress at buccal side of 1st premolar was the lowest in swing-lock partial denture and that was highest in attchment retained removable partial denture. The stress at lingual side of 1st premolar was the lowest in telescopic partial denture. 3. In clasp retained removable partial denture, stress was lower at load site and ridge crest at mid-line, but it was higher at 1st premolar area on vertical load. 4. In attachment removable partial denture, stresses at buccal side of 1st premolar. lingual side of 1st premolar on vertical load, and ridge crest at midline on oblique load were higher. 5. In telescopic removable partial denture, stress at lingual side of 1st premolar was the least in all removable partial dentures, but the stress at load site was higher. 6. In swing-lock removable partial denture, stress at buccal side of 1st premolar was the lowest, and stresses at load site and distal end of residual ridge crest were higher.

  • PDF

상악 완전 무치악 환자에서 6개의 임플란트를 동반한 두가지 가철성 의치 치료의 8년 경과 관찰 증례 (Eight-year follow-up of two different removable prostheses using six implants in maxillary edentulous patients)

  • 양승원;김종은;김지환
    • 대한치과보철학회지
    • /
    • 제55권3호
    • /
    • pp.300-304
    • /
    • 2017
  • 자연치열에 대합하는 완전 무치악 환자의 수복에서 임플란트를 이용한 고정성 보철물 또는 임플란트 피개의치는 좋은 치료법이다. 그러나, 완전 고정성 보철을 통한 치료는 충분한 골질, 골량이 뒷받침되어야 하기에 그 한계가 있다. 한편, 최근에는 임플란트 고정성 보철물과 함께 그것을 가철성 국소의치의 지대치로 사용하는 치료가 행해지고 있다. 본 증례보고는 자연치열에 대합되는 두 상악 완전 무치악 환자에 있어 임플란트 피개의치와 임플란트 고정성 보철물 및 가철성 국소의치를 이용한 치료 및 8년 경과관찰, 유지보수를 비교 고찰해 보고자 한다.

적합도에 따른 ITI 임플란트 지지 고정성 국소의치의 삼차원 유한요소 분석 (Three Dimensional Finite Element Analysis on ITI Implant Supported Fixed Partial Dentures with Various Fitting Accuracy)

  • 최민호;이일권;김유리;조혜원
    • 구강회복응용과학지
    • /
    • 제22권1호
    • /
    • pp.75-87
    • /
    • 2006
  • The purpose of this study was to investigate the effects of prostheses misfit, cantilever on the stress distribution in the implant components and surrounding bone using three dimensional finite element analysis. Two standard 3-dimensional finite element models were constructed: (1) 3 ITI implant supported, 3-unit fixed partial denture and (2) 3 ITI implant supported, 3-unit fixed partial denture with a distal cantilever. variations of the standard finite element models were made by placing a $100{\mu}m$ or $200{\mu}m$ gap between the fixture, the abutment and the crown on the second premolar and first molar. Total 14 models were constructed. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the distal marginal ridge of the distal molar. von Mises stresses were recorded and compared in the crowns, abutments, crestal compact bones, and trabecular bones. The results were obtained as follows: 1. In the ITI implant system, cement-retained prostheses showed comparatively low stress distributions on all the implant components and fixtures regardless of the misfit sizes under vertical loading. The stresses were increased twice under oblique loading especially in the prostheses with cantilever, but neither showed the effects of misfit size. 2. Under the oblique loading and posterior cantilever, the stresses were highly increased in the crestal bones around ITI implants, but effects of misfit were not shown. Although higher stresses were shown on the apical portion of trabecular bones, the effects by misfit were little and the stresses were increased by the posterior cantilever. 3. When the cement loss happened in the ITI implant supported FPD with misfit, the stresses were increased in the implant componets and supporting structures.

심한 하악 치조제 흡수를 가진 환자에서 임플란트를 이용한 가철성 국소의치로 수복한 증례 (Implant-assisted removable partial denture for severely atrophied mandible)

  • 최바다;김연주;이재훈
    • 대한치과보철학회지
    • /
    • 제57권2호
    • /
    • pp.171-175
    • /
    • 2019
  • 치조제가 심하게 흡수된 하악의 정확한 해부학적 구조를 채득하는 것은 매우 어렵다. 이 경우 보다 정확한 인상을 채득하기 위하여 수정모형 제작법을 통한 기능 인상 채득이 추천된다. 이를 위해서는 양측에 2개의 임플란트 크라운을 이용하여 적절한 고정원을 얻을 필요가 있다. 이를 통해 임플란트 피개의치에서는 불가능하였던 수정모형 제작법을 시행할 수 있다. 본 증례에서는 하악의 치조제가 심하게 흡수된 80세 여환을 하악 양측 견치 부위의 임플란트 크라운을 지대치로 한 가철성 국소의치를 이용하여 수복하였다. 가철성 국소의치의 금속구조물을 이용하여 개인 트레이를 제작하고 수정모형 제작을 위한 이차 인상을 채득하였다. 환자는 앞선 2회의 피개의치 실패 후 제작된 최종 보철물에 만족하였다. 치료 초기에 행해진 피개의치 치료에서는 부정확한 인상법에 따른 부적절한 보철물로 인해 술자와 환자 모두 만족하지 못했지만, 2개의 임플란트를 적절한 고정원으로 이용함으로써 성공적인 수복이 가능하였다.

Comparative evaluation of peri-implant stress distribution in implant protected occlusion and cuspally loaded occlusion on a 3 unit implant supported fixed partial denture: A 3D finite element analysis study

  • Acharya, Paramba Hitendrabhai;Patel, Vilas Valjibhai;Duseja, Sareen Subhash;Chauhan, Vishal Rajendrabhai
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.79-88
    • /
    • 2021
  • Purpose. To assess peri-implant stress distribution using finite element analysis in implant supported fixed partial denture with occlusal schemes of cuspally loaded occlusion and implant protected occlusion. Materials and methods. A 3-D finite element model of mandible with D2 bone with partially edentulism with unilateral distal extension was made. Two Ti alloy identical implants with 4.2 mm diameter and 10 mm length were placed in the mandibular second premolar and the mandibular second molar region and prosthesis was given with the mandibular first molar pontic. Vertical load of 100 N and and oblique load of 70 N was applied on occlusal surface of prosthesis. Group 1 was cuspally loaded occlusion with total 8 contact points and Group 2 was implant protected occlusion with 3 contact points. Results. In Group 1 for vertical load, maximum stress was generated over implant having 14.3552 Mpa. While for oblique load, overall stress generated was 28.0732 Mpa. In Group 2 for vertical load, maximum stress was generated over crown and overall stress was 16.7682 Mpa. But for oblique load, crown stress and overall stress was maximum 22.7561 Mpa. When Group 1 is compared to Group 2, harmful oblique load caused maximum overall stress 28.0732 Mpa in Group 1. Conclusion. In Group 1, vertical load generated high implant stress, and oblique load generated high overall stresses, cortical stresses and crown stresses compared to vertical load. In Group 2, oblique load generated more overall stresses, cortical stresses, and crown stresses compared to vertical load. Implant protected occlusion generated lesser harmful oblique implant, crown, bone and overall stresses compared to cuspally loaded occlusion.

보철물(補綴物) 장착시(裝着時) 치근막(齒根膜)과 치조골(齒槽骨)의 변화(變化)에 관(關)한 X선학적(線學的) 연구(硏究) (Roentgenologic Studies on the Periodontal Ligaments and Alveolar Bone Changes in Various Prosthesis)

  • 이재희
    • 대한치과보철학회지
    • /
    • 제9권1호
    • /
    • pp.17-22
    • /
    • 1969
  • Intra-oral films of 155 patients were taken on the areas of Gold Crown-Bridges, S. P. Bridges and Partial Dentures. And the author observed periodontal ligaments widening rates, the presence of periapical lesions and the alveolar bone patterns on the Partial Denture Saddle portions. The results were as follows : 1. Periodontal ligaments a) Periodontal ligaments widening rate increased obviously with the duration of wearing those prosthetic appliances. b) Periodontal ligaments widening rate was the highest in partial denture wearing patients, and then that of S. P. Crown Bridge patients, Gold Crown Bridge wearing females, Gold Crown Bridge males were the sequences. 2. Periapical lesions a) Periapical lesions increased with the wearing duration of those prosthetic appliances. But they did not increase in proportion to the duration. Periapical lesions were about the same in the teeth with those appliances showing relatively higher rate in Partial Denture abutment teeth and the lowest in Gold-Bridge abutment teeth. 3. Alveolar bone of Partial Denture saddle portion One third of all(32%) were normal with their smooth and compact bone pattern so that they were considered to perform normal function.

  • PDF

엇갈린 교합 및 교합평면 부조화를 가진 부분무치악 환자에서 임플란트를 이용한 가철성 국소의치 증례 (Rehabilitation of a crossed-occlusion patient using implant-assisted removable partial denture with Locator® attachment: A case report)

  • 김동운;최정윤;서재민;이정진
    • 대한치과의사협회지
    • /
    • 제54권7호
    • /
    • pp.513-520
    • /
    • 2016
  • In crossed occlusion, displacement of removable partial denture is likely to occur during function due to different characteristics of abutment and supporting tissue. It increases discomfort to the patient. In addition, adverse effect on the residual ridge and abutment can induce an unfavorable prognosis of the denture. In this case, a small number of implants can be placed in strategic locations. Attachment can be added for additional support and retention of removable partial denture assisted by implants. This article describes the rehabilitation of a crossed occlusion patient using implant-assisted removable partial denture with Locator$^{(R)}$ attachment. After 24 months, the patient was satisfied with the aesthetic and function of the prosthesis that is maintained stable.

  • PDF

실패한 고정성 임플란트 보철물을 제거 후 임플란트 융합 가철성 국소의치로 전환 치료한 증례 (A conversion to implant assisted removable partial denture in failed fixed implant prosthesis of mandible: A case report)

  • 진승리;정창모;윤미정;허중보;이현종;이소현
    • 대한치과보철학회지
    • /
    • 제58권2호
    • /
    • pp.161-168
    • /
    • 2020
  • 임플란트 고정성 보철물의 실패는 과도한 교합스트레스와 같은 생역학적인 요인과 세균 감염, 염증과 같은 생물학적인 요인으로 인하여 일어난다. 임플란트 합병증으로 인한 문제가 해결되지 않고 악화되어 심한 골흡수가 일어난 임플란트는 제거되어야 하며, 제거 후 잔존 치아와 잔존 임플란트 및 잔존 치조제를 고려하여 새로운 치료를 계획해야 한다. 본 증례의 환자는 하악 무치악부에 약 10년 전 식립한 하악 고정성 임플란트 보철물 중 일부를 임플란트 주위염으로 인하여 제거하게 되었다. 추가 임플란트 재식립을 위한 잔존 치조골의 상태를 재평가 하고 소수의 임플란트를 추가 식립 후 임플란트 서베이드 크라운을 지대치로 하는 임플란트 융합 가철성 국소의치로 최종 치료하였다. 이를 통해 실패 이후 저작기능을 다시 회복하고 구강위생 관리에 유리한 조건으로 전환하였기에 이를 보고하고자 한다.

Functionally generated path technique 및 구내 디지털 스캔을 이용한 상악 구치부의 고정성 보철 수복 증례 (Fixed prosthodontic rehabilitation of maxillary posterior teeth using functionally generated path technique and intraoral digital scan: Case report)

  • 김성호;이종혁;최유성
    • 대한치과보철학회지
    • /
    • 제58권3호
    • /
    • pp.228-238
    • /
    • 2020
  • 환자의 교합에 맞춰 적절한 고정성 보철물을 성공적으로 제작 및 수복하기 위해서 필요한 다양한 고려사항이 있다. 그 중 환자가 갖고 있는 교합의 형태를 파악하여 고정성 보철물에 부여하는 것은 필수적이라 할 수 있다. 견치 유도 교합, 군 기능 교합 등 여러가지 교합 형태를 파악하는데 있어서 하악의 운동을 기록하는 것이 중요한데, 1933년 Meyers에 의해 소개된 Functionally generated path (FGP) technique은 구내에서 왁스 등의 재료를 이용하여 교두가 지나가는 하악 운동로를 기록한 후 보철물 제작에 적용하는 치료 술식이다. 본 증례에서는 두 명의 환자에 있어서 상악 구치부에 이차 우식 혹은 치주염으로부터 기원한 치수 유래 병소가 있어, 근관 치료 및 치주 치료 완료 후 고정성 보철물 수복이 필요하였다. 장기적인 예후가 좋지 않은 치아이기에 측방 간섭을 최소화하기 위해 FGP technique을 이용하여 하악 운동을 기록하였다. 통상적인 석고 인상 방법이 아닌 구내 디지털 스캔을 시행함으로써 더 효율적으로 보철물을 제작하였다. 치료 후 환자와 술자 모두 기능적으로 만족할 만한 결과를 얻었기에 이를 보고하는 바이다.

소수의 임플란트 크라운을 지대치로 이용한 하악 가철성 국소 의치 수복 증례 (Mandibular implant assisted removable partial denture with a small number of implant crowns: two case reports)

  • 김유라;이수영
    • 구강회복응용과학지
    • /
    • 제38권2호
    • /
    • pp.110-119
    • /
    • 2022
  • 부분 무치악 환자의 가철성 국소의치 수복 시 지대치가 항상 유리한 위치에 존재하지는 않는다. 이로 인하여 잘 맞게 제작된 가철성 국소의치임에도 불구하고 환자는 가철성 국소의치의 안정과 지지에 대하여 만족하지 못하는 경우가 발생하게 된다. 이 때, 소수의 임플란트 크라운을 이용한 가철성 국소의치가 부분 무치악 환자에게 좋은 대안이 될 수 있다. 소수의 임플란트를 위치시키고 지대치로 이용하여 가철성 국소의치의 안정과 지지를 증가시킬 수 있다. 본 증례는 하악 편측에 잔존치를 갖는 환자에서 두개의 임플란트를 전략적으로 위치시켜 지대치를 양측으로 분포시켰다. 최종 가철성 국소의치 수복 이후 환자는 저작 기능에 만족감을 보였으며 국소의치 사용시 편안함을 나타내었다.