• 제목/요약/키워드: Partial insulation

검색결과 462건 처리시간 0.027초

수력발전기 고정자 권선의 운전중 부분방전 특성 (Properties of On-Line Partial Discharge in Hydrogenerator Stator Windings)

  • 김병한;김희동
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권4호
    • /
    • pp.172-177
    • /
    • 2006
  • During normal machine operation, partial discharge(PD) tests were performed with partial discharge analyzer(PDA) in two hydrogenerators. Six cable couplers were installed in circuit ring bus and endwinding of three phases. PDA showed that the normalized quantity number(NQN) and the partial discharge magnitude$(Q_m)$ were very low in hydrogenerator #1 and #2, respectively. The trend analyses of NQN and $Q_m$ value are available for monitoring of the insulation condition in hydrogenerator stator windings. The insulation condition of stator winding can be assessed. Discharge at conductor surface was discovered in B phase(C2 coupler) of hydrogenerator #1. Internal discharges were generated in A and C phases(C2 coupler) of hydrogenerator #1 and in A, Band C phases(C1 and C2 couplers) of hydrogenerator #2. Slot discharges occurred in A, Band C phases(C1 coupler) of hydrogenerator #1. The stator windings of two hydrogenerators were in good condition.

超音波 信號 數의 移動平均에 의한 電力用 變壓器 豫防診 (Preventive diagnosis of the power transformer by the moving average of ultrasonic signal number)

  • 권동진;곽희로;정상진;김정부
    • 대한전기학회논문지
    • /
    • 제45권3호
    • /
    • pp.432-437
    • /
    • 1996
  • This paper describes a diagnostic technique of power transformers by on-line detection of ultrasonic signals. A trend of partial discharge variation in a real transformer was estimated by counting the number of ultrasonic signals until insulation paper in the point-to-plane electrode is punctured. The number of electrical signals is closely related to the ultrasonic signals generated by partial discharge. The trend of the ultrasonic signal number could easily be distinguished by taking moving average. The insulation failure due to partial discharge in transformers can be predicted based on the trend analysis of ultrasonic signal number caused by partial discharge. (author). 14 refs., 10 figs.

  • PDF

변압기 절연지 표면 금속 이물질 방전에 의한 극초단파 신호특성 (Characteristics of Ultra High Frequency Partial Discharge Signals from Metallic Particle Defected Oil-paper Insulation in Transformer)

  • 윤진열;주형준;구선근;박기준
    • 한국전기전자재료학회논문지
    • /
    • 제22권10호
    • /
    • pp.879-883
    • /
    • 2009
  • This paper was provided to help in detecting defects in power transformer. For this purpose, a partial discharge cell was designed and manufactured as a discharge source to simulate particle defected paper-oil insulation in power transformer. Experimental set-up for measuring PD signals was described. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and pattern of PRPD(Phase Resolved Partial Discharge) of partial discharge signals were examined and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the substation faults.

Identification of Partial Discharge Defects based on Back- Propagation Algorithm in Eco-friendly Insulation Gas

  • Sung-Wook Kim
    • Journal of information and communication convergence engineering
    • /
    • 제21권3호
    • /
    • pp.233-238
    • /
    • 2023
  • This study presents a method for identifying partial discharge defects in an eco-friendly gas insulated system using a backpropagation algorithm. Four partial discharge (PD) electrode systems, namely, a free-moving particle, protrusion on the conductor, protrusion on the enclosure, and voids, were designed to simulate PD defects that can occur during the operation of eco-friendly gas-insulated switchgear. The PD signals were measured using an ultrahigh-frequency sensor as a nonconventional method based on IEC 62478. To identify the types of PD defects, the PD parameters of single PD pulses in the time and frequency domains and the phase-resolved partial discharge patterns were extracted, and a back-propagation algorithm in the artificial neural network was designed using a virtual instrument based on LabVIEW. The backpropagation algorithm proposed in this paper has an accuracy rate of over 90% for identifying the types of PD defects, and the result is expected to be used as a reference database for asset management and maintenance work for eco-friendly gas-insulated power equipment.

함침기법에 따른 인버터 구동 유도전동기 고정자 권선의 절연성능 평가 (Evaluation of Insulation Performance for Stator Winding of the Inverter Driven Induction Motor According to Impregnation Methods)

  • 황돈하;강동식;이인우;김동희;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.487-492
    • /
    • 2006
  • Inverter driven induction motors with high speed switching and advanced PWM techniques are widely used for variable speed applications. Recently, the insulation failures of stator winding have attracted much concern due to high dv/dt of IGBT PWM inverter output. In this paper, the detailed insulation test results of 26 low-voltage induction motors are presented. Six different types of insulation techniques are applied to 26 motors. The insulation characteristics are analyzed with partial discharge, inception voltage, AC current, and dissipation factor tests. Also, breakdown tests by high voltage pulses are performed. From the above test data the effects due to different wires and insulation techniques on the insulation characteristics of low-voltage induction motors are compared and analyzed. The insulation technique to enhance the insulation strength is suggested from the test results.

  • PDF

인버터 구동형 저압 유동전동기의 절연특성 분석 (Analysis of Insulation Characteristics of Low-Voltage Induction Motors Fed by Pulse-Controlled Inverters)

  • 박도영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.195-198
    • /
    • 2000
  • In this paper the insulation characteristics test results of 25 low-voltage induction motors($3\phi$, 5HP, 380V) are presented. Five different types of insulation techniques are applied to 25 motors. The maximum partial discharge (PD) magnitude ($\textrm{Q}_{m}$) discharge inception voltage (DIV) dissipation factor tip-up ($\Delta$tan$\delta$) and rate of change in AC current($\Delta$I) are measured by PD and AC current tests. Also the insulation breakdown tests by high voltage pulse are performed and the corresponding breakdown voltage are obtained.

  • PDF

회전기 고정자 권선의 절연상태 평가 (Assessment of Insulation Condition in Rotating Machine Stator Windings)

  • 김희동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1706-1708
    • /
    • 2001
  • Nondestructive tests are used to evaluate the insulation condition of stator windings in rotating machine. These tests included ac current, tan delta and maximum partial discharge. The insulation condition of stator windings was assessed by three test items. The stator windings were generally in good condition, wash, reimpregnation and rewind. It was confirmed that nondestructive tests were most useful method to indicate the insulation condition of stator windings.

  • PDF

고압회전기 절연진단 주기 설정에 관한 연구 (A Study on the Establishment of Insulation Diagnosis Cycle for High Voltage Rotating Machine)

  • 이영준;김희동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1939-1941
    • /
    • 2000
  • Nondestructive and destructuve insulation tests were performed the high voltage rotating machine in the local thermal power plants. Nondestructive tests include measurements of insulation resistance. polarization index, AC current. tan$\delta$, partial discharge. Destructive tests include measurements of AC hipot and DC hipot. This paper propose to establish the insulation diagnosis cycle for high voltage rotating machine.

  • PDF

고체 합성수지절연체와 표면노화 진단기술로서의 부분방전 측정평가기술에 대하여 (Partialt Discharge Measurement Techniques for Diagnosis of Surface Aging on Organic Insulation)

  • 박완기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 춘계학술대회 논문집
    • /
    • pp.50-56
    • /
    • 1994
  • Partial discharge on organic insulation surfaces are an important sauce of aging. Furthermore the modern PD measurement technigues are rapid developed as quality control and diagnostic tests to determine the fitness for use of HV equipment employing sol id electrical insulation. This paper deals with theory of conventional PD measurement and new tendency of technical development on PD measurements und evaluations. Finally the Measuring system used for diagnosing the surface aging on the organic insulation at High Voltage Laboratory of Technical University of Darmstadt in Germany is presented.

  • PDF

A Study of the Characteristics of a Partial Discharge of SF6 Following a Fault

  • Yoon, Dea-Hee;Song, Hyun-Jig;Lee, Kwang-Sik
    • 조명전기설비학회논문지
    • /
    • 제21권9호
    • /
    • pp.18-24
    • /
    • 2007
  • When faults occur in the power equipment that is used a great deal in industrial sites, it may lead to fatal accidents that cause losses both economically and in manpower. In this paper, the effect of particle impact on the partial discharge of $SF_6$ gas was measured by simulating a partial discharge following the type of fault found in the GIS using $SF_6$ insulating gas as the insulating material. A spectrum analysis was performed on the radiate electromagnetic waves emitted upon partial discharge by using the UHF insulation diagnosis method. This subject of this study is insulation diagnosis by the measurement of radiate electromagnetic waves when particles exist in the GIS and power equipment insulated with $SF_6$ gas.