• 제목/요약/키워드: Partial insulation

검색결과 462건 처리시간 0.048초

변압기 절연열화진단 시스템개발에 관한 고찰 (Study on Development of Insulation Degradation Diagnosis System for Electrical Transformer)

  • 김이곤;유권종;김서영;조용섭;박봉서;최시영;심상욱
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.139-144
    • /
    • 2001
  • Insulation aging diagnosis system provides early warning regarding electrical equipment defect. Early warning is very important in that it can avoid great losses resulting from unexpected shutdown of the production line. Since relations of insulation aging and partial discharge dynamics are non-linear, it is very difficult to provide early warning in an electrical equipment. In this paper, we propose the design method of insulation aging diagnosis system that use a magnetic wave and acoustic signal to diagnoses an electrical equipment. Proposed system measures the partial discharge on-line from DAS(Data Acquisition System) and acquires 2D patterns from analyzing it. For filtering the noise contained in sensor signals we used ICA algorithms. Using this data, design of the neuro-fuzzy model that diagnoses an electrical equipment is investigated. Validity of the new method is asserted by numerical simulation.

  • PDF

$SF_6$ EHV VT 권선 절연지의 절연특성 (Insulation Characteristics of PET Films for $SF_6$ EHV VT Winding)

  • 김정달;박재윤;정장근;김종석;하현진;이용길
    • 한국전기전자재료학회논문지
    • /
    • 제14권5호
    • /
    • pp.391-396
    • /
    • 2001
  • The purpose of this study is to investigate the effect of hole or crack on the Insulation characteristics of a PET films for EHV(Extra High Voltage) VT winding. The hole or the crack in the PET films was made and the insulation characteristics of them were measured. Ad an experimental result, it was shown hat he PDIV(Partial Discharge Inception Voltage) and the BDV(Breakdown Voltage) of the PET films with hole or crack were lower than those without them, and were markedly dependent on their position and temperature. Therefore, the hole and the crack affected to insulation characteristics of PET films for SF$_{6}$EHV(Extra High Voltage) VT Winding.g.

  • PDF

고압 전동기 고정자 권선의 상태진단을 위한 운전중 모니터링 시스템 개발 (Development of On-Line Monitoring System for Insulation Diagnosis of High-Voltage Motor Stator Windings)

  • 황돈하;심우용;김용주;송상옥;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1701-1703
    • /
    • 2002
  • This paper introduces a on-line monitoring system for insulation diagnosis of high-voltage motor stator windings. This system monitors the insulation condition of the stator winding with sensor, coupling capacitor. Partial discharge (PD) signals are able to be continuously measured and digitalized with a Peak-hold A/D converter to build the database of the high-voltage motor's insulation condition. This system can communicate with the central monitoring system via RS-485 This paper introduces an economic solution for data acquisition of partial discharges.

  • PDF

발전기 고정자 권선의 새로운 절연열화 판정기준 설정에 관한 연구 (A Study on the New Criteria for Assessing the Insulation Deterioration of Generator Stator Winding)

  • 황돈하;김용주;김진봉;전정우;김희곤;박종정
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1692-1695
    • /
    • 1997
  • This paper describes the relationship between the various non-destructive parameters and the breakdown voltage for the 17 kV, 300 MVA and the 22 kV, 500 MVA generators stator bars with polyester and epoxy/mica insulation respectively. Also, this study reports the results of an investigation into the factors which can assess the insulation condition of generator stator winding. Furthermore, a new parameter, Partial Discharge Index(PDI), is introduced as the valuable parameter for the assessment of insulation condition. The ratio between partial discharge increment and the stepwise voltage increment from the Discharge Inception Voltage (DIV) at the characteristic or resonant frequency band shows the close relationship between the breakdown voltage and PDI.

  • PDF

전력케이블의 절연결함에 따른 부분방전 특성분석 (Analysis of PD Characteristics by Types of Insulation Defects in Power Cables)

  • 최재성;박찬용;김선재;한주섭;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1977-1983
    • /
    • 2009
  • This paper described partial discharge(PD) patterns depending on types of insulation defects in CNCO-W cable(Concentric Neutral Closs-linked Polyethylene Insulated Polyolefin-Water Proof Sheathed Power Cable). The PD measurement system consists of a coupling network, a detection impedance, and a low noise amplifier. A 16 bit, 250 MS/s data acquisition system was used to analyze PD patterns. To simulate insulation defects in a power cable, a needle with the curvature radius of $10{\mu}m$ was inserted into the insulation part. We measured phase ($\Phi$), magnitude (q), and counts (n) of PD pulse for the defects, and classified PD patterns using the PRPD (phase Resolved Partial Discharge) method. From the analysis of acquired PD signals, we could find that a unique PD pattern is formed according to the types of defect.

  • PDF

유중 부분방전 음향신호의 전달특성 (Propagation Characteristics of Acoustic Signals Produced by Partial Discharge in Insulation Oil)

  • 김성욱;박찬용;박대원;길경석;류길수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.841-847
    • /
    • 2009
  • This paper describes the propagation characteristics of acoustic signals as a function of distance from the location of partial discharge(PD) occurrence to analyze correlation between discharge magnitude and acoustic signal in insulation oil. To measure small acoustic signals produced by PD, we fabricated an amplifier and simulated PD at a needle-plane electrode system set in insulation oil. The amplifier has the gain of 40 dB and the frequency bandwidth of 1.6 kHz$\sim$1.6 MHz. These are enough characteristics for the measurement of acoustic signals. After a comparative calibration experiment by a standard pulse generator and a coupling capacitor, we analyzed the propagation characteristics of acoustic signals in insulation oil.

  • PDF

고온초전도 케이블의 굴곡 변화에 따른 전기절연 특성 (Electrical Insulation Characteristics of HTS Cables according to Bending Strain)

  • 곽동순;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권1호
    • /
    • pp.45-48
    • /
    • 2009
  • Research on the mechanical properties of the dielectric paper and mini-model cable are important for optimum electrical insulation design of HTS cable, because the HTS cable experience of mechanical stress, such as tensile and bending stress. Also, it is operated at cryogenic temperature. Therefore, this paper discusses the experiment results on the AC and lighting impulse breakdown characteristics, partial discharge inception and extinction characteristics, and external shape change of the insulation layer according to bending strain of the mini-model cable.

수력 발전기의 운전중 부분방전 측정기법에 대한 신뢰성 평가 (Evaluation of On-Line Partial Discharge Measurement Techniques on Hydro-Generator)

  • 황돈하;김진봉;김용주;박명수;김택수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1526-1529
    • /
    • 1994
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the end winding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current test and ${\Delta}tan{\delta}$ test has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot discharges may not be found with off-line diagnoses. This paper describes the on-line partial discharge measurement techniques in the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

전극형상 및 보이드에 따른 XLPE의 부분방전 특성 (Partial Discharge Characteristics of XLPE According to Electrode Shape and Void)

  • 신종열;김균식;홍진웅
    • 한국전기전자재료학회논문지
    • /
    • 제29권1호
    • /
    • pp.50-57
    • /
    • 2016
  • Transmission equipment is mainly used for the XLPE (cross-linked polyethylene) insulation cable for ultra high voltage power to minimize power loss. The experiment examined the partial discharge characteristics according to the insertion of the bar electrode and needle electrode into the XLPE specimen and the air voids. XLPE insulation cable manufactured by T. company and tungsten electrode material by K. company were used for specimens, by adhering conductive tape on the semi-conductive material of the lower electrode of XLPE specimen with the dimension of $16{\times}40{\times}30$ [mm] was used as negative electrode. In order to investigate the PD with ${\phi}$-q-n of XLPE specimen according to the electrode shape and the size of air voids. we examined the PD by varying the voltage after applying voltage of 3~20 kV on the electrode. Therefore, it was confirmed from the result of PD characteristics of specimen that the larger the air void than the gap between electrode (+) and electrode(-), the larger effect on the discharge when the bar electrode and needle electrode inserted into XLPE, and the closer the distance between the insulation and the needle electrode, the faster insulation breakdown.

유중 부분방전의 음향검출에 관한 연구 (A Study on the Acoustic Detection of Partial Discharges in Insulation Oil)

  • 길경석;김성욱;박대원;김선재;송재만
    • 한국전기전자재료학회논문지
    • /
    • 제23권1호
    • /
    • pp.53-60
    • /
    • 2010
  • This paper dealt with the acoustic detection of partial discharge (PD) in insulation oil for insulation diagnostics of oil immersed transformers. Electrode systems such as needle to plane, plane to plane, and floating were fabricated to simulate some defects in transformers. A wide band acoustic emission(AE) sensor with the frequency ranges of 100 kHz~1 MHz and a narrow band AE sensor with the resonant frequency of 140 kHz were used in the experiment. Also, a decoupler and an amplifier were designed to detect and amplify the acoustic signal only. The decoupler separates acoustic signal from DC source without any distortion, and the amplifier has the gain of 40 dB in frequency ranges of 11 kHz~4 MHz. In the experiment, frequency components and propagation characteristics of acoustic signal were analyzed, and an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the results, the frequency components of the acoustic signal exist from 50 kHz to 200 kHz and the positioning error of PD calculated by three AE sensors was within 1%.