Partial Discharge Ultrasonic Analysis for Generator Stator Windings

  • Yang, Yong-Ming;Chen, Xue-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.670-676
    • /
    • 2014
  • The objective of this research is to utilize the ultrasonic method to analyze the property of partial discharge (PD) which is generated by the winding of the insulation stator in the generator. Therefore, a PD measurement system is built based on ultrasonic and virtual instruments. Three types of PD models (internal PD model, surface PD model and slot PD model) have been constructed. With the analysis of these experimental results, this research has identified the ultrasonic signals of the discharges which were produced by three types of PD models. This analysis shows the different features among these PD types. Both the time domain and frequency domain of the ultrasonic signals are obviously different. In addition, an experiment based on a large rotating machine has been done to analyze ultrasonic noises. The result indicates that the ultrasonic noises can be wiped off by the filters and algorithms. The application of this system is convenient for the detection of early signs of insulation failure, which is an effective method for diagnosis of insulation faults.

Analysis of Insulation Diagnostic Test for High Voltage motor (II) (고압전동기 절연진단 해석 (II))

  • Lee, Young-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2107-2109
    • /
    • 1999
  • The insulation diagnostic tests was performed at local thermal power plants high voltage motor. The insulation diagnostic tests include measurements of insulation resistance, polarization index, AC current, $tan{\delta}$, partial discharges. This paper describes Insulation characteristics for high voltage motor which located by inside and outside.

  • PDF

Characteristics of Insulation Degradation in Epoxy Mold Type BCT (에폭시 몰드형 BCT의 절연열화 특성)

  • Song, Jae-Joo;Lee, Jung-Choi;Lim, Sung-Hun;Ko, Seok-Cheol;Han, Byung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.10
    • /
    • pp.902-908
    • /
    • 2005
  • Various stresses (such as electrical stress, mechanical stress, environmental and electrochemical stress, and defects of structure) result in insulation degradation of epoxy mold type insulators. Since the insulation degradation of BCT(Bushing Current Transformer) and bushing proceeds during fabrication process or operation time due to these causes, various methods to reduce the degradation in their insulation ability have been suggested. In this paper, we investigated surface temperature increment of these insulators due to PD(partial discharge). After the voltage applied into the insulator to generate the artificial PD, the surface temperature of the insulator was measured with non-contact thermometer using infrared rays. It was confirmed through the analysis based on PD experiments that the procession in the insulation degradation of the insulator could be estimated through the measurement of the surface temperature in the insulator.

Development of Central Monitoring System for Insulation Diagnosis of High-Voltage Generator/Motor Stator Windings (고압 회전기 고정자 권선의 절연진단을 위한 중앙 집중 감시 시스템 개발)

  • Shin, Byoung-Chol;Yoon, Dae-Hee;Hwang, Don-Ha;Kim, Yong-Joo;Ju, Young-Ho;Kim, Jeong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1906-1908
    • /
    • 2000
  • The central monitoring system with on-line diagnosis of high-voltage generator/motor stator insulation is developed. The system is capable of remote diagnosis and monitoring partial discharges of high-voltage generator/motor stator insulation. GOMS(Generator On-line Monitoring System) with maximum of 9 input channels can measure and analyze the status of high-voltage motor stator insulation by on-line. The measured and analysis data are brought to the central monitoring system via modem to build database. The central monitoring system can diagnose and monitor the insulation status of several high-voltage generator/motor at any time. The insulation status of those machines can be enhanced by the database on partial discharges.

  • PDF

Assessment of Insulation Condition in Large Transformers (대형변압기 절연상태 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik;Lee, Young-Jun;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.499-502
    • /
    • 2004
  • In order to detect of insulation problems an early, transformer has to be performed the several tests. The ac current and tan6 of transformer winding insulation were investigated by Schering bridge. Partial discharge(PD) tests are used to evaluate the insulation condition of transformer. The moisture content measurement was conducted using RVM(recovery voltage meter). The RVM test can show that the problem is affecting the paper insulation of transformer. The value of moisture content was 2.3% in main transformer. The insulations of four transformers were judged to be in good condition.

  • PDF

The Development of wide frequency analyzing system by partial electric discharge electromagnetic-wave Receiver (부분방전 전자파 측정용 광대역 주파수 분석 시스템 개발)

  • Park, Doo-Yong;Shin, Young-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.547-549
    • /
    • 2004
  • This system is monitors the degree of aging happened at the electric machine. It detects electromagnetic wave generated from the insulator when the voltage is applied to the machine. By analyzing the internal and external factors make the electric, mechanic, or thermal characteristics of the electric machinery deteriorate the electric insulation and eventually cause the partial electric discharge. The continuous partial electric charge accelerates the insulation aging and the insulation breakdown happens at last. This system consists of the relays connected with 10 sensors (40 total) detecting the partial electric discharge ans the temperature, the server, ans the program analyzing and storing the data.

  • PDF

Signal Characteristics of Ultra-high Frequency Radiation from Partial Discharge in Insulation Oil (절연유에서 부분방전에 의한 극초단파 신호 특성분석)

  • Ju, Hyoung-Jun;Goo, Sun-Geun;Park, Ki-Jun;Han, Ki-Seun;Yoon, Jin-Yul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.56-59
    • /
    • 2008
  • We have designed 4 types(void in insulation paper, protrusion electrode, floating electrode, surface discharge) of partial discharge(PD) defect to simulate typical faults found in oil filled power transformers. Ultra-high frequency(UHF) radiation due to PD was measured using a UHF measuring system and a conventional PD measuring system, simultaneously. Electromagnetic radiation spectra of these defects show UHF radiation up to about 1.5-2 GHz range. The phase resolved partial discharge(PRPD) patterns of UHF radiation from the PD defects were also measured and the pattern reveals distinct feature for each defect types. The UHF measuring could be used to detect PDs in oil filled transformers and analysis of the PRPD pattern should provide useful information on origin of PD signal.

The Electric Field Distribution Characteristic Of Outdoor ECT Using the Preventive Diagnostic Sensor (예방진단센서가 내장된 옥외용 ECT의 전계분포특성)

  • Lee, Han-Joo;Cho, Sung-Hoon;Jung, Eui-Hwan;Yoon, Jae-Hoon;Lim, Kee-Joo;Kang, Sung-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.27-27
    • /
    • 2010
  • The exact partial discharge pulse should be measured in order to estimate the discharge source in the solid insulation and diagnose the degree of deterioration. Partial discharges generated in the insulation occur in the internal voids or at the edge of the insulation, have unique characteristics following the type and location. When external voltage is applied, Partial discharges occurred in the restrictively presented voids increase the quantity of electrical charge at the discharge onset voltage. The discharge characteristics have remained constant as space is filled by the impurity such as a compound of gases accompanied with discharge. In this study, How to design the insulation about the problems of the built-in diagnostics in the transformer is discussed by the interpretation of electric field.

  • PDF

Partial Insulation and Heating Tubes Configuration of Shell and Tube Steam Reformer at Medium Temperature (중온형 원통다관형 수증기 개질기의 부분단열 및 반경방향 분배 구조의 영향)

  • PARK, DAIN;YU, SANGSEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.6
    • /
    • pp.618-626
    • /
    • 2017
  • Conventional high temperature reformers are not suitable for hybrid fuel cell systems that use waste heat as a heat source. So, development of a low temperature type reformer is needed. However, the analysis was conducted in two ways to increase the thermal efficiency, because of low reforming rate due to the low heat source. First, it is a way to ger thermal gain from the outside through partial insulation. In the case of one heat source tube and several heat source tubes, we analyzed the effect of partial heat insulation in some cases. Second, we found the most efficient arrangement of the heat source tubes by changing the location of the heat source tubes. The interpretation was carred out using the COMSOL Mutiphysics program.

Optimal Design of an Antenna for the Detection of Partial Discharges in Insulation Oil (절연유중 부분방전 검출을 위한 안테나의 최적 설계)

  • Lee, Jung-Yoon;Jo, Hyang-Eun;Park, Dae-Won;Kil, Gyung-Suk;Oh, Jae-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.4
    • /
    • pp.309-314
    • /
    • 2013
  • This paper dealt with the radiated electromagnetic wave detection of partial discharge (PD) in oil for insulation diagnostics of oil-immersed transformers. Three types of electrode system were fabricated to simulate the insulation defects that could occur in oil-immersed transformers. Frequency components of radiated electromagnetic wave in oil was measured by broadband bi-conical antennas of 300 MHz~2 GHz and a spectrum analyzer of 9 kHz~3 GHz. Frequency component of electromagnetic waves from PD in oil were highly distributed at 500 MHz. From the result, a narrow-band monopole antenna with the center frequency of 500 MHz was fabricated. We could detect PD signal in insulation oil without an influence of external noise by a measurement system which consists of the prototype monopole antenna, a LNA (Low Noise Amplifier), an oscilloscope and a spectrum analyzer.