• Title/Summary/Keyword: Partial insulation

Search Result 462, Processing Time 0.028 seconds

Measurement and Analysis of Insulation Detects of Cast-resin Transformers using Antenna (안테나를 이용한 몰드변압기 절연결함 측정기법 연구)

  • Choi, Myeong-Il;Kim, Jae-Jin;Han, Ga-Ram;Jeon, Jeong-Chay;Lee, Hyun-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1937-1942
    • /
    • 2016
  • Unlike oil immersed transformers, cast-resin transformers have the solid insulator 'epoxy resin' in sealed structure. Therefore, they reveal a lot of limitations in checking aging conditions and predicting an accident. This study analyzed the characteristics of Cast-resin transformers by the measurement distance and measurement sensitivity with a corona defect sample, using antenna sensor. Therefore, the experiment has proven that the antenna sensor-based measurement method proposed in this study is able to detect the insulation defect location of the cast-resin transformer, unlike conventional measurement methods. It is expected that the result of this study will be used to develop a new type of measuring method in order to measure insulation defects and to use in safety inspection of domestic cast-resin transformers.

Characteristics of Insulation Diagnosis and Failure in 6.6 kV Motor Stator Windings (6.6 kV 전동기 고정자 권선의 절연진단과 절연파괴 특성)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • To assess the condition of stator insulation, nondestructive and overpotential tests were performed on four high voltage motors. The stator windings under these tests have nominal ratings of 6.6 kV. After completing nondestructive tests, the AC overvoltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No. 1, No. 2, No. 3 and No. 4 of 6.6 kV motors failed near rated voltage of 18.4 kV, 19.8 kV, 19.7 kV and 21.7 kV, respectively. The breakdown voltage of four motors was higher that expected for good quality coils(14.2 kV) in 6.6 kV motors. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor($tan{\delta}$) and partial discharge magnitude.

Performance Evaluation of SHF Sensor for Partial Discharge Signal Detection on DC Rectifier (DC 정류기 부분방전 신호검출을 위한 SHF 센서의 성능평가)

  • Jung, Ho-Sung;Park, Young;Na, Hee-Seung;Jang, Soon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.1056-1060
    • /
    • 2012
  • Online monitoring system is becoming an essential element of railway traction system for utilized to condition based malignance management and various techniques currently employed in railway traction system. Among the various techniques, it is efficient to detect partial discharge signals by electromagnetic wave detection in order to detect insulation fault of rectifier. Although VHF (Very High Frequency), UHF (Ultra High Frequency) sensors were adopted to detect partial discharge of power facilities, due to characteristics of urban railway, excessive noise occurs from 500 MHz to 1.5 GHz on UHF bandwidth. In this paper a new measurement system able to monitoring the conditions of power facilities on DC substation in metro was studied and set up. The system uses UHF sensors to measure the partial discharge of the rectifier due to electric faulting and dielectric breakdown. Comparison and estimation for performance of SHF sensor which had devised to detect partial discharge signal of urban railway rectifier has conducted. In order to estimate performance of SHF sensor, we have compared the sensor with existing UHF sensor on sensitivity upon frequency bandwidth generated by pulse generator, and also we have verified performance of the SHF sensor by detection results of partial discharge signal from urban railway rectifier.

A POSSIBLE APPLICATION OF CHAOTIC ANALYSIS FOR THE INVESTIGATE OF THE INSULATION DEGRADATION CAUSED BY THE VARIOUS DEFECTS (다양한 절연열화 분석을 위한 카오스 분석방법 적용 연구)

  • Yun, Jeung-Hoon;Lim, Yun-Sok;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1606-1608
    • /
    • 2001
  • In connection with the monitoring of the insulation degradation of the large power apparatus, a statistical treatment, such as phase resolved partial discharge analysis (PRPDA) has been established for the on-line monitoring system during the past two decades. However, it has shown some inconveniences to distinguish the nature of the PD source in power apparatus. In this regard, a novel approach based on the chaotic analysis(CAPD) is proposed describing the fundamental ideas, outcomes and different view points from conventional PRPDA. In order to make a model for the possible defects causing sudden failures in service, several types of specimen were prepared. And partial discharge signals, originated from those samples, were measured and analyzed by means of PRPDA and CAPD respectively. In this paper, it seems that the correlation between the consecutive PD pulses depending on the nature of PD could be investigated by CAPD. Therefore, it could be considered that the nature of PD source can be distinguished more distinctively when the PRPDA is combined with CAPD.

  • PDF

A Study on Insulation Degradation Diagnosis Using a Neural Network (신경회로망을 이용한 절연 열화진단에 관한 연구)

  • 박재준
    • The Journal of Information Technology
    • /
    • v.2 no.2
    • /
    • pp.13-22
    • /
    • 1999
  • In this paper, we purpose automatic diagnosis in online, as the fundamental study to diagnose the partial discharge mechanism and to predict the lifetime by introduction a neural network. In the proposed method, we use AE(acoustic emission) sensing system and calculate a quantitative statistic parameter by pulse number and amplitude. Using statically parameters such as the center of gravity(G) and the gradient if the discharge distribute(C), we analyzed the early stage and the middle stage. the quantitative statistic parameters are learned by a neural network. The diagnosis of insulation degradation and a lifetime prediction by the early stage time are achieved. On the basis of revealed excellent diagnosis ability through the neural network learning for the patterns during degradation, it was proved that the neural network is appropriate for degradation diagnosis and lifetime prediction in partial discharge.

  • PDF

A comparative study of the PD pattern analysis based on PRPD and CAPD for the diagnosis of Gas Insulated Transformer (GITr(Gas Insulated Transformer) 내부에 발생되는 PD 신호의 패턴분석을 위한 PRPD와 CAPD 적용 결과 비교)

  • Jung, Seung-Yong;Lim, Yun-Sok;Koo, Ja-Youn;Chang, Yong-Moo;Kang, Chang-Won;Lee, Yung-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2060-2062
    • /
    • 2005
  • Partial Discharge (PD) phenomena occurred by different nature of insulating defects has been regarded as a random process by which Phase Resolved Partial Discharge Analysis (PRPDA) has been proposed and then commercially accepted for the diagnosis of the power apparatus since more than three decades. Moreover, for the same purpose, a novel approach based on the Chaotic Analysis(CAPD) has been proposed since 2000, in which PD phenomena is suggested to be considered as a deterministic dynamical process. In this work for the diagnosis of GITr, four different types of specimen were fabricated as a model of the possible defects that might possibly cause its sudden failures such as turn to turn insulation, inter coil insulation, free moving particle and protrusion. For this purpose, these defects are introduced into the GITr mock-up and experimental investigations have been carried out in order to analyze the related PD patterns by means of both PRPDA and CAPD respectively and then their comparisons are made systematically.

  • PDF

Analysis of On-Line Partial Discharge Patterns in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 운전중 부분방전 패턴 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1824-1827
    • /
    • 2003
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in two high voltage motors. Two 6.6kV motors were installed with 80pF capacitive couplers at the terminal box. The PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantifies such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). Off-line PD measurements were conducted on one 4.16kV motor. The motor was energized to 2.4kV, 3.0kV, 3.5kV and 4.16kV, respectively. The PD levels in pC were measured with a conventional digital PD detector. The comparison of positive to negative PD indicates whether the defect elements of PD are within the insulation or on the insulation surface. Discharge at conductor surface was discovered in No. 1 motor. Internal discharges were generated in phase A, B and C of No. 2 motor, Slot discharges occurred in three phases of No. 3 motor.

  • PDF

Characteristics of Radiated Electromagnetic Waves in Model GIS with Electrical Trouble and Design of Insulted Diagnosis UHF Sensor (모의 GIS의 전기적 이상에 따른 방사전자파의 특성과 절연진단용 UHF 센서 설계)

  • Park, Kwang-Seo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.47-52
    • /
    • 2008
  • In this paper partial discharge were simulated by conducted particle, a fine protrusion, surface discharge, which could be easy accumulated charge and concentrated electric field in the model GIS. In this times this paper measured and analyzed the radiated electromagnetic waves by using spectrum analyzer and antenna ($30{\sim}2,000[MHz]$ for measurement of EMI EMC in accordance with occurrence and propagation of partial discharge. In the basis of this results, a novel UHF(Ultra High Frequency) spherical sensor is presented. The measured impedance bandwidth of the proposed antenna is from 0.3[GHz] to 1.7[GHz]. Form results of this study, this antenna will be playing an important role for the sensor for insulation diagnosis system by UHF method of real site GIS and power equipment using $SF_6$ gas.

Development of Equipment to Measure Insulation Resistance and Evaluate the Lifetime of High-voltage Cable in Operation (운전 중인 고전압 케이블의 절연저항 측정 및 수명평가장치의 개발)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.237-242
    • /
    • 2014
  • In this paper, we find out the lifetime index in order to determine the time-dependent trend of deteriorating performance of 6.6kV high-voltage power cable in operation at a power station. The cable systems used in our study have been in operation for 13 years. With measurements for the 13 years, we analyzed the insulation resistances. By developing measuring equipment (comprized mainly of transformer, temperature sensor, and LPF) operating by the three-phase electric power, we analyzed the changing characteristics of insulation resistance of power cable. In contrast to 22kV cables, 6.6 kV cables have thicker insulation. Therefore the characteristics of 6.6kV cables are different from that of 22kV cables. The study found that as time passes, the insulation resistance does not decrease continuously; it decreases to a certain value, then does not decrease any more and shows properties of oscillation. We could not detect the process of deterioration in the preceding twelve years. The cable system showed great stability so that deterioration was not apparent. In this case, it is not possible to measure the future life indices of power cables because the lifetime indices are not predictable

A Life Prediction of Insulation Degradation Using Complex Sensing System (복합 감지 시스템을 이용한 부분방전의 절연열화 수명추정)

  • Kim, S.H.;Kim, J.H.;Park, J.J.;Choi, J.K.;Yoon, H.J.;Lee, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.348-350
    • /
    • 1997
  • Because of internal voids ininsulators give rise to partial discharge(PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation has become important. From this viewpoint, our studies diagnose insulation degradation using the method of computer sensing system, which has the advantages of PD and acoustic emission(AE) sensing system. To use advantages of these two methods can be used effectively to search for treeing location and PD in some materials. In analysis method of degradation. We analyzed the PD pulse and AE pulses by regression analysis, compared to these obtained the correlation coefficient and determination coefficient by T-distribution and saw that PD and AE pulses show a similar pattern on the whole. Finally using statically operator such as the center of gravity(G), the gradient of the discharge distribution(C), we have analyzed for the prediction of life which we can be obtained the time, occurred of many pulse of small discharge amplitude.

  • PDF