• 제목/요약/키워드: Partial insulation

검색결과 462건 처리시간 0.055초

Electrical Insulation Characteristics at Cryogenic Temperature for High Temperature Superconducting Cables

  • Okubo, Hitoshi;Hayakawa, Naoki
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권1호
    • /
    • pp.15-20
    • /
    • 2004
  • This paper discusses electrical insulation characteristics at cryogenic temperature, especially focusing on partial discharge (PD) inception characteristics, for high temperature superconducting cables. In liquid nitrogen (L$N_2$) / polypropylene (PP) laminated paper composite insulation system, PD inception strength (PDIE) was evaluated in terms of volume effect and V-t characteristics. Different kinds of butt gap condition were applied in the experiments, using parallel plane and coaxial cylindrical cable samples. Experimental results revealed that the volume effect on PDIE could be evaluated by the statistical stressed liquid volume (SSLV) taking account the discharge probability not only in the butt gap but also in the other thin layers between PP laminated papers. Furthermore, the indices n of V-t characteristics at PD inception were estimated to be 80∼110, irrespective of the butt gap condition.

부분 방전 전하와 음향 방출 펄스의 동시 측정에 의한 트리잉 파괴 진단 (The Diagnosis of Treeing Breakdown Using Simultaneous Detection of Electrical Charge and Acoustic Emission Pulse of Partial Discharge)

  • 김성홍;박재준;김재환
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권3호
    • /
    • pp.247-254
    • /
    • 1997
  • Internal voids in insulators give rise to partial discharge, which causes a local breakdown and even entire insulation breakdown. Recently, the necessity of establishing the way to diagnose the aging of insulation materials and to predict of insulation breakdown become important. The purpose of our work are to investigate the treeing phenomena with an artificial needle shaped void by the charge of discharge and acoustic emission pulse in each phase angle area at the same time. We analyzed the .PHI.-QA-t pattern and .PHI.-AEA-t pattern using statistic operators such as pulse magnitude, pulse number, skewness, kurtosis. Therefore, the relation between the charge of discharge and acoustic emission pulse will be helpful to predict the breakdown just before the breakdown occur.

  • PDF

고압전동기 고정자 권선의 절연파괴 특성 (Characteristics of Insulation Failure in High Voltage Motor Stator Windings)

  • 김희동;김경열;박덕현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.124-124
    • /
    • 2010
  • Diagnostic tests were performed on six high voltage motors. These tests included ac current, dissipation factor(tan6) and partial discharge(PD) magnitude. The rewind of motor stator insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 1 and No.2 motors(4.16 kV) failed near rated voltage of 12.3 kV and 14.2 kV, respectively. The breakdown voltage of No.3 and No.4 motors(6.6 kV) was 17.6 kV and 17.8 kV, respectively. These motors are higher that expected for good quality coils in 6.6 kV class motors.

  • PDF

고압 전동기 고정자 권선의 절연진단을 위한 운전중 부분방전 측정 시스템 개발 (Development of On-Line Partial Discharge Measuring System for Insulation Diagnosis of High-Voltage Motor Stator Windings)

  • 황돈하;강동식;신병철;이영진;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.481-486
    • /
    • 2006
  • In this paper, a new on-line high-voltage motor monitoring system is proposed. This system monitors the insulation condition of the stator winding by on-line measurements of partial discharge (PD). And this system displays magnitude and phase angle distribution of PD. Sensor, CC (Ceramic Coupler) is used for PD measurement. PD signals are continuously measured and digitized with a A/D converter to build the database of the high-voltage motor's insulation condition. Also, this system can communicate with the central monitoring system via RS-232, 422, and TCP/IP. This helps more efficient operation and maintenance of the high-voltage motor.

  • PDF

수력발전기 고정자권선의 절연보강 후 절연특성 분석 (Analysis of Insulation Characteristics for Stator Winding after Insulation Reinforcement)

  • 오봉근;최교남;최형철;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.71-73
    • /
    • 2006
  • Our company(KOWACO) has periodically performed off-line diagnostic test for 14 hydro generators (rated 11 kV over) for 15 years. In this paper, we summarized results of dissipation factor tip-up test and partial discharge test about these generators. Among these, we chose two generators and performed insulation reinforcement (cleaning and varnish Painting). We compared change of insulation condition for the stator winding based upon off-line diagnostic test result before and after repair. Test result shows that insulation condition was improved after insulation reinforcement. This insulation reinforcement has a function to reduce cause of deterioration, so we can know that it extends lifetime of generator and it is a very important factor for stable operation of facilities.

  • PDF

회전자 고정자권선의 절연보수후 절연특성변화 연구 (Change of the Insulation Characteristic for the Rotating machine stator winding after insulation reinforcement)

  • 오봉근;최교남;최형철;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.51-52
    • /
    • 2006
  • Our company(KOWACO) has periodically performed off-line diagnostic test for 14 hydro generators (rated 11 kV over) for 15 years. In this paper, we summarized results of dissipation factor tip-up test and partial discharge test about these generators. Among these, we chose two generators and performed insulation reinforcement (cleaning and varnish painting). We compared change of insulation condition for the stator winding based upon off-line diagnostic test result before and after repair. Test result shows that insulation condition was improved after insulation reinforcement. This insulation reinforcement has a function to reduce cause of deterioration, so we can know that it extends lifetime of generator and it is a very important factor for stable operation of facilities.

  • PDF

고압전동기 고정자 권선의 PRPD 부분방전 결함신호 해석 (Analysis on Partial Discharge Fault Signals of PRPD for High Voltage Motor Stator Winding)

  • 박재준;이성룡;문대철
    • 한국전기전자재료학회논문지
    • /
    • 제19권10호
    • /
    • pp.942-946
    • /
    • 2006
  • We simulated insulation defects of stator winding wire on high voltage generator by 5 types. 4 types have one discharge source and other one has multi discharge source by simulation. For accurate decision, measurements used to PRPD pattern to occurred partial discharge source of various types. In this research, when PRPD pattern carried out or analyzed pattern recognition of discharge source, it used to powerful tools. In this result, PRPD Pattern defined to have single discharge source of 4 types by insulation defect. When insulation defect simulated, all the defected winding have not the same result. Errors for a little different can make mistakes from a subtle distinction. The difference between internal and void discharge have magnitude of pulse amplitude of inner discharge bigger than void discharge and have a shape of bisymmetry. But void discharge has a shape of bisymmetry against maximum value on polarity respectively. In cases of slot and surface discharge, we confirmed to show similar results those other researchers. In case of multi-discharge, as a result of we could classify not perfect match with occurred patterns in single discharge eachother. In the future, we will have to recognize and classify with results of multi-discharge.

고압전동기 고정자권선의 부분방전 특징추출 (Feature Extraction of Partial Discharge for Stator Winding of High Voltage Motor)

  • 박재준
    • 정보학연구
    • /
    • 제7권4호
    • /
    • pp.61-69
    • /
    • 2004
  • 본 논문에서는 6.6kV급 고압전동기 모델 코일을 4가지의 권선의 인공적인 결함을 갖도록 제작하였다. 운전중 모의를 위해 모델 코일에 80pF의 에폭시-마이카 커플러를 설치하였으며, TGA를 사용하여 NQN, 부분방전 크기 및 부분방전 패턴 등을 측정하였다. 웨이블렛 변환기법을 이용한 고압전동기의 고정자권선의 결함에서 발생된 부분방전신호의 파형을 통하여 여러 가지의 통계적인 파라메터를 통하여 특징을 추출하였다.

  • PDF

고전압회전기 고정자권선 운전중 부분방전진단시스템의 현장적용사례 연구 (A Case Study of On-line PD Measuring System on the Stator Winding for High Voltage Rotating Machine)

  • 오봉근;강동식;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.109-109
    • /
    • 2010
  • On-line partial discharge(PD) diagnostic system is the most prominent systems to diagnose insulation condition for the high voltage rotating machines. Partial discharge measuring system(PDMS) series with ceramic coupler(PD detecting sensor) installed hydro generator and high voltage motor have been measured the PD data for many years. The trend of PD magnitude in the on-line PD system increased for some machines. These machines showed a same result in the conventional off-line PD test and PD magnitude decreased after stator winding insulation cleaning. This case study show that PDMS has been proved to be good results by comparing PD magnitude with on-line and off-line PD test and it is important to plan the maintenance project for the hydro generator stator winding because PD value was decreased after insulation cleaning.

  • PDF

모노폴 안테나를 이용한 유중 부분방전의 검출 (Detection of Partial Discharges by a Monopole Antenna in Insulation Oil)

  • 박대원;이정윤;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제25권9호
    • /
    • pp.727-731
    • /
    • 2012
  • This paper dealt with the measurement and analysis of electromagnetic waves radiated from a partial discharge (PD) source in insulation oil to apply condition monitoring of oil-immersed transformers. Two types of narrow-band monopole antennas with the resonant frequency of a 500 MHz and a 1 GHz were designed and fabricated. Also, a needle-plane electrode system was manufactured to simulate PDs and the curvature radius of the needle is 10 ${\mu}m$ and the diameter of the plane is 60 mm. Electromagnetic wave was measured by the PD measurement system with the monopole antennas. Detection sensitivity of the fabricated antenna was compared for the same PD magnitude; 620 $mV_{peak}$ for the 500 MHz antenna and 960 $mV_{peak}$ for the 1 GHz antenna to the PD magnitude of 74 pC. Consequently, the 1 GHz monopole antenna is more effective to detect PDs in oil-immersed transformers.