• Title/Summary/Keyword: Partial discharge source

Search Result 98, Processing Time 0.024 seconds

Optimal P-Well Design for ESD Protection Performance Improvement of NESCR (N-type Embedded SCR) device (NESCR 소자에서 정전기 보호 성능 향상을 위한 최적의 P-Well 구조 설계)

  • Yang, Jun-Won;Seo, Yong-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.3
    • /
    • pp.15-21
    • /
    • 2014
  • An electrostatic discharge (ESD) protection device, so called, N-type embedded silicon controlled rectifier (NESCR), was analyzed for high voltage operating I/O applications. A conventional NESCR standard device shows typical SCR-like characteristics with extremely low snapback holding voltage, which may cause latch-up problem during normal operation. However, our modified NESCR_CPS_PPW device with proper junction/channel engineering such as counter pocket source (CPS) and partial P-well structure demonstrates highly latch-up immune current-voltage characteristics with high snapback holding voltage and on-resistance.

A POSSIBLE APPLICATION OF CHAOTIC ANALYSIS FOR THE INVESTIGATE OF THE INSULATION DEGRADATION CAUSED BY THE VARIOUS DEFECTS (다양한 절연열화 분석을 위한 카오스 분석방법 적용 연구)

  • Yun, Jeung-Hoon;Lim, Yun-Sok;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1606-1608
    • /
    • 2001
  • In connection with the monitoring of the insulation degradation of the large power apparatus, a statistical treatment, such as phase resolved partial discharge analysis (PRPDA) has been established for the on-line monitoring system during the past two decades. However, it has shown some inconveniences to distinguish the nature of the PD source in power apparatus. In this regard, a novel approach based on the chaotic analysis(CAPD) is proposed describing the fundamental ideas, outcomes and different view points from conventional PRPDA. In order to make a model for the possible defects causing sudden failures in service, several types of specimen were prepared. And partial discharge signals, originated from those samples, were measured and analyzed by means of PRPDA and CAPD respectively. In this paper, it seems that the correlation between the consecutive PD pulses depending on the nature of PD could be investigated by CAPD. Therefore, it could be considered that the nature of PD source can be distinguished more distinctively when the PRPDA is combined with CAPD.

  • PDF

Application of Joint Electro-Chemical Detection for Gas Insulated Switchgear Fault Diagnosis

  • Li, Liping;Tang, Ju;Liu, Yilu
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1765-1772
    • /
    • 2015
  • The integrity of the gas insulated switchgear (GIS) is vital to the safety of an entire power grid. However, there are some limitations on the techniques of detecting and diagnosing partial discharge (PD) induced by insulation defects in GIS. This paper proposes a joint electro-chemical detection method to resolve the problems of incomplete PD data source and also investigates a new unique fault diagnosis method to enhance the reliability of data processing. By employing ultra-high frequency method for online monitoring and the chemical method for detecting SF6 decomposition offline, the acquired data can form a more complete interpretation of PD signals. By utilizing DS evidence theory, the diagnostic results with tests on the four typical defects show the validity of the new fault diagnosis system. With higher accuracy and lower computation cost, the present research provides a promising way to make a more accurate decision in practical application.

A Study on the Aging Characteristics of Power Capacitors using Electrical Methods (전기적 방법을 이용한 전력용 콘덴서 열화특성 연구)

  • 김은식;김영욱;김종서;윤철섭;박대희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.199-202
    • /
    • 1998
  • Power capacitors are highly reliable equipment due to their completely enclosed configuration. Aging diagnosis system using partial discharge(PD) and acoustic emission(AE) is being highlighted as a research area for degradation of power capacitors. Their dielectric strength can be however reduced due to some stresses such as over-voltage or thermal degradation of the insulation material during their long period of operation. In this paper, it has been developed to express the AE of the EVENT(average amplitude) and HIT(pulse count) according to the source location. And real time measurement of PD signals for aging diagnosis of power capacitors.

  • PDF

Electric field distribution Analysis and Occurrence of Partial Discharge using Numeric Analysis Program (수치해석프로그램을 이용한 전계분포해석과 부분방전의 발생)

  • Lee, Kang-Won;Park, Cheol-Hyun;Kang, Sung-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.603-606
    • /
    • 2004
  • Aspects of PD occurrence from PD sources are different with their physical and structural appearances which cause the variation of electric field distributions of them. This paper have investigated electric field distributions of some kinds of electrode structure by FEM applied analysis program. Numeric analysis is a good method to investigate Ihe electric and magnetic field distribution of partial discharge source. The analysis results were confirmed by real PD occurring situation in the laboratory.

  • PDF

New Method of PD measuring on MV XLPE Cable by Using Prototype Patch Antenna (Prototype 패치 안테나를 이용한 MV급 전력케이블의 부분방전 측정 연구)

  • Lwin, K.S.;Shin, D.H.;Lim, K.J.;Kong, T.S.;Kim, H.D.;Park, N.J.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.146-148
    • /
    • 2007
  • We studied the partial discharge detecting by sensing electromagnetic wave emitted from the partial discharge source in the MV XLPE cable with the new type of patch antenna sensor. In this study, we design new kind of Patch antenna and make many experiments compare with the existing HFCT sensor on MV XLPE cable in the laboratory. According to our experimental results our new sensor can defect pure PD and wider bandwidth 20MHz to 70MHz than HFCT and can easily localized manually on the cable.

  • PDF

PD Diagnosis on High Voltage Rotating by Using New Prototype Patch Antenna Sensor (prototype 패치 안테나를 이용한 고압 회전기의 부분방전 측정 연구)

  • Lwin, K.S.;Shin, D.H.;Lim, K.J.;Kong, T.S.;Kim, H.D.;Park, N.J.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.169-171
    • /
    • 2007
  • We studied the partial discharge detecting by sensing electromagnetic wave emitted from the partial discharge source in the HV Rotating Machine with the new prototype patch antenna sensor. In this study, we design new type of patch antenna based on microstrip technology and make many experiments of elaine testing compare with the existing HFCT and EM probe on stator winding of HV generator in the laboratory. This paper will mention comparison of experimental results based on the three kinds of sensors.

  • PDF

High Luminous Efficiency Flat Light Source with Xe mixture Gas Discharge and Areal Brightness Control Method (제논 혼합가스를 이용한 고효율 면광원과 국부적 밝기 제어 방식)

  • Jung, Jae-Chul;Seo, In-Woo;Oh, Byung-Joo;Whang, Ki-Woong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.153-157
    • /
    • 2009
  • A Highly efficient Mercury-free Flat Fluorescent Lamp (MFFL) with dielectric barrier Xe gas discharge was developed for an alternative of conventional line-type Cold Cathode Fluorescent Lamps (CCFLs) which shows a wide voltage margin and a stable discharge operation for diffuse glow discharge with an application of a auxiliary electrode. Electro-optic characteristics of the MFFL were examined through the changes in ambient temperature, total pressure and Xe partial pressure. the single cell is expanded into a multi-structured configuration to realize a large sized lamp by a simple repetition of the single cells, and a new driving scheme is proposed for an adaptive brightness control using dual auxiliary electrodes and bi-polar drive scheme. In addition, interesting application of this ultra high luminance flat lamp by the optimization of the gas condition and the pattern of the rear phosphor layer is suggested as a good alternative of daylight lamp source

  • PDF

Study of Electromagnetic Characteristics for Air discharge using Ultra - wideband Antenna (광대역 안테나를 이용한 기중방전현상에 대한 전자기적 특성에 관한 연구)

  • Lee K. W.;Yoon S. C.;Kim M. Y.;Baik K. S.
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1489-1491
    • /
    • 2004
  • PD in air is accompanied by light, sound and electromagnetic wave. Light and sound can be prevented from blocking between PD sources and sensor but electromagnetic wave can be transferred to long distance without any interference an captured by antenna. This paper investigated the wideband antenna is appropriate for sensing Partial discharge in air. PD was generated from simulated PD source which consist of needle and flat electrode with small gap. Signals obtained from wideband antenna were diminished in both time and frequence region with the distance between PD source and antenna.

  • PDF

Analysis of Propagation Characteristics of Acoustic Signal in Insulation Oil (음향신호의 유중 전파특성 분석)

  • Yun, Min-Young;Park, Kyoung-Soo;Wang, Guoming;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.2
    • /
    • pp.114-119
    • /
    • 2016
  • This paper dealt with the propagation characteristics of acoustic signal in insulation oil for the purpose of improving the reliability of AE (acoustic emission) method used for condition monitoring of oil-immersed transformers. A discharge source was placed in insulation oil and AE sensors ($f_c$ :140 kHz) were attached on the oil tank to study the changes of velocity and propagation path with the depth and distance. The average velocity was 1,436 m/s and the velocity decreased with the increase of depth from the oil surface to 430 mm. The propagation paths were classified into three sections by the shortest reflection path of the detected signal. The minimum distinguishable distance in each section was 70 mm. It was also verified that PD (partial discharge) with a magnitude over than 500 pC can be detected by the AE sensors.