• Title/Summary/Keyword: Partial discharge detection

Search Result 197, Processing Time 0.034 seconds

Design and Fabrication of a PD Detector for Power Cable Diagnosis (전력케이블 진단을 위한 부분방전 검출장치의 설계 및 제작)

  • Song Jae-Yong;Seo Hwang-Dong;Kil Gyung-Suk;Han Moon-Soeb;Jang Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.777-782
    • /
    • 2005
  • In this paper, we designed and fabricated a partial discharge (PD) detector to diagnose the soundness of CNCV cables by analyzing PD pulses and to predict discharge locations. The PD detector is consisted of a coupling network with a discharge free capacitor and a detection impedance, a voltage follower and a low noise amplifier. Lower cut-off frequency of the detector is adjusted at 175kHz to block AC voltage and to pass discharge pulse only. The discharge location could be obtained by the time of arrival method using travelling wave propagation theory. In a laboratory test on an eighty meter CV cable, we could position the discharge location within a two meter error.

  • PDF

A Study on PD Detection Methods for Cast-resin Dry-type Transformers (몰드변압기의 부분방전 검출기술에 관한 연구)

  • Park, Chan-Yong;Park, Dae-Won;Choi, Jae-Sung;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.9
    • /
    • pp.786-791
    • /
    • 2009
  • Transformer failures are mostly due to partial discharges (PDs) caused by the deteriorated insulation. It is, therefore, important to monitor PD occurrence in insulation system and prevent their deterioration. The presented paper deals with a PD detection method by a capacitive probe, which easily apply to cast - resin dry - type transformers. The PD detection system consists of a capacitive probe and a low noise amplifier having the frequency bandwidth of 500 $Hz{\sim}30$ MHz. In the experimental set-up, sensitivity of the system is 7.16 mV/pC.

Neural Network Model for Partial Discharge Pattern Analysis of XLPE/EPR Interface (XLPE/EPR 계면의 부분방전 패턴 분석을 위한 신경망 모형)

  • Cho Kyung-Soon
    • Journal of the Korea Computer Industry Society
    • /
    • v.6 no.2
    • /
    • pp.279-286
    • /
    • 2005
  • The prefabricated type used generally in Korea to join cable runs on new installations or to repair broken Cable runs on existing installations, because installation is very simple and save time. This type is a permanent, shielded and submersible cable joint for direct burial or vault application. It confirms to the requirements of IEEE std. 404-1993 by factory testing, but many problems of insulated cable systems are caused by internal defects of the joint part which have to be mounted ensile. Faults arise from impurities or voids. A suitable solution for a monitoring of cable joints during the after-laying test and service is partial discharge detection. <중략> $\Phi-q-n$ properties were measured using detection impedance, high pass filter and computerized data acquisition system. Statistic Value like maximum charge, repetition rate, average charge, etc. are calculated. It is possible to quantitative analysis of $\Phi-q-n$ properties from this statistic value and pattern analysis.

  • PDF

Detection of Ultrasonic Characteristics of Oil Corona by Wide-Band AE Sensor (광대역 AE 센서에 의한 유중코로나의 초음파 특성)

  • Kim, In-Sik;Lee, Sang-U;Lee, Dong-In;Lee, Gwang-Sik;Kim, Lee-Guk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.44-51
    • /
    • 2000
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz] to 1.5[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane gap and from the partial discharges of an epoxy void were analyzed to determine the proper ultrasonic sensor with optimum frequency range according to the patterns of corona discharges. We also examined the propagation characteristics of AE signals in oil and the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] ac high-voltage. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were about 130[kHz] by the fast fourier transform, but the main frequency spectra appeared to be 230[kHz] in the partial discharges of an epoxy void. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages.

  • PDF

Signal analysis of surface discharge and electromagnetic wave for insulator by kaolin contamination (카올린으로 오손된 애자의 표면방전 및 방사전자파의 신호 분석)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.7 no.3
    • /
    • pp.113-118
    • /
    • 2004
  • Recently, diagnosis techniques have been investigated to detect a partial discharge associated with a dielectric material defect in a high voltage electrical apparatus. However, the properties of detection technique of PD aren't completely understood because the physical process of PD. Therefore, this paper analyzes the process on Surface Discharge of Polymer Insulator using Wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time frequency domain. As it is important to develop a non-contact method for detecting the Contamination Degree, this research analyzes the electromagnetic waves emitted from PD using Wavelet transform. This result experimentally shows the process of PD as a two-dimensional distribution in the time-frequency domain. The method is shown to be useful for detecting prediction of contamination degree.

  • PDF

A Study on the Detection of Acoustic Signal Produced by Partial Discharges in Insulation Oil and its Positioning (부분방전에 의한 음향신호의 검출과 위치추정에 관한 연구)

  • Kil, Gyung-Suk;Park, Dae-Won;Kim, Il-Kwon;Choi, Su-Yeon;Park, Chan-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.907-911
    • /
    • 2007
  • This paper dealt with the frequency spectrum analysis of acoustic signal produced by partial discharge (PD) in insulation oil and the positioning of PD occurrence to apply in diagnosis of oil insulated transformers. Three types of electrode system ; the needle-plane, the plane-plane, and the wire-wire structure were assembled to simulate partial discharges in oil insulated transformers. A low-noise amplifier and a decoupling circuit were designed to detect acoustic signal with high sensitivity The frequency spectrum of the acoustic signal were 50 kHz ${\sim}$ 260 kHz in the needle-plane, 50 kHz ${\sim}$ 250 kHz in the plane-plane, and 45 kHz${\sim}$195 kHz in the wire-wire electrode system. Their peak frequencies were 145 kHz, 130 kHz and 114 kHz, respectively The position of PD occurrence was calculated by the time difference of arrival (TOA) using three acoustic emission (AE) sensors, and we could find the position within the error of 1 % in the experimental apparatus.

Pattern Analysis by Using PD Signal generated in Bushings (부싱에서 발생하는 부분방전 신호를 이용한 패턴분석(1))

  • Lee, Chang-Jun;Park, J.H.;Ham, Kil-Ho;Kim, Hyuk-Tae;Kim, Pyung-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1951-1953
    • /
    • 2000
  • Partial Discharge is non-disruptive discharge, which can be discriminated to 3 kinds as firstly, internal discharge which is caused by internal voids inside of insulator, secondly, surface discharge which occurs from the surface of insulator and finally, corona discharge which is from the surface of an electrode. In this thesis, three kinds of defects are artificially made to the inside and the surface of the epoxy resine busing with internal voltage detection sensor, which is practically equipped into SF6 gas insulated switchgear for 22.9kV distribution line, so that discrimination of three kinds of PD signals by means of phi-q-n pattern analysis method was performed.

  • PDF

Design and Fabrication of Rogowski-type Partial Discharge Sensor for Insulation Diagnosis of Cast-Resin Transformers (몰드 변압기의 절연 진단을 위한 로고우스키형 부분방전 센서의 설계 및 제작)

  • Lee, Gyeong-Yeol;Kim, Sung-Wook;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.6
    • /
    • pp.594-602
    • /
    • 2022
  • Cast-resin transformers are widely installed in various electrical power systems because of their low operating cost and low influence on external environmental factors. However, when they have an internal defect during the manufacturing process or operation, a partial discharge (PD) occurs, and eventually destroys the insulation. In this paper, a Rogowski-type PD sensor was studied to replace commercial PD sensors used for the insulation diagnosis of power apparatus. The proposed PD sensor was manufactured with four different types of PCB-based winding structures, and it was analyzed in terms of the detection characteristics for standard calibration pulses and the changes of the output voltage according to the distance. The output increased linearly in accordance with the applied discharge amount. It was confirmed that the hexagon structure sensor had the highest sensitivity, because the winding cross-sectional area of the sensor was larger than others. In addition, as the distance from the defect increased, the output voltage of the sensors decreased by 7.32% on average. It was also confirmed that the attenuation rate according to the distance decreased as the input discharge amount increased. For the application of this new type sensor, PD electrode system was designed to simulate the void defect. Waveforms and PRPD patterns measured by the proposed PD sensors at DIV and 120% of DIV were the same as the results measured by MPD 600 based on IEC 60270. The proposed PD sensors can be installed on the inner wall of the transformer tank by coating its surfaces with a non-conductive material; therefore, it is possible to detect internal defects more effectively at a closer distance from the defect than the conventional sensors.

A Possible Application of the PD Detection Technique Using Electro-Optic Pockels Cell With Nonlinear Characteristic Analysis on the PD signals

  • Kang, Won-Jong;Lim, Yun-Sok;Chang, Young-Moo;Koo, Ja-Yoon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.2
    • /
    • pp.6-11
    • /
    • 2001
  • Abstract- In this paper, a new Partial Discharge (PD) detection using Pockels cell was proposed and considerable apparent chaotic characteristics were discussed. For this purpose, PD was generated from needle-plane electrode in air and detecte by optical measuring system using Pockels cell, based on Mach-Zehner interferometer, consisting of He-Ne laser, single mode optical fiber, 50/50 beam splitter and photo detector. In addition, the presence of chaos of the PD signals has been investigated by examining their means of qualitative and quantitative information. For the former, return map and 3-dimensional strange attractor have been drawn in order to investigate the presence of chaotic characteristics relevant to PD signals, detected through CT and Peckels sensor respectively, in the normalized time series. The presence of strange attractor indicates the existence of fractal structures in it's phase space. For the latter, several dimension values of strange attractor were verified sequentially. Throughout this paper, it is likely that the chaotic characteristics regarding the PD signals under air are verified.