• Title/Summary/Keyword: Partial denture

Search Result 423, Processing Time 0.025 seconds

Rehabilitation of a crossed-occlusion patient using implant-assisted removable partial denture with Locator® attachment: A case report (엇갈린 교합 및 교합평면 부조화를 가진 부분무치악 환자에서 임플란트를 이용한 가철성 국소의치 증례)

  • Kim, Dong-Woon;Choi, Jung-Yun;Seo, Jae-Min;Lee, Jung-Jin
    • The Journal of the Korean dental association
    • /
    • v.54 no.7
    • /
    • pp.513-520
    • /
    • 2016
  • In crossed occlusion, displacement of removable partial denture is likely to occur during function due to different characteristics of abutment and supporting tissue. It increases discomfort to the patient. In addition, adverse effect on the residual ridge and abutment can induce an unfavorable prognosis of the denture. In this case, a small number of implants can be placed in strategic locations. Attachment can be added for additional support and retention of removable partial denture assisted by implants. This article describes the rehabilitation of a crossed occlusion patient using implant-assisted removable partial denture with Locator$^{(R)}$ attachment. After 24 months, the patient was satisfied with the aesthetic and function of the prosthesis that is maintained stable.

  • PDF

The fabrication of abutment crowns for existing removable partial denture using CAD/CAM: A clinical report (CAD/CAM을 이용하여 기존 국소의치에 맞는 지대치 보철물 제작 증례)

  • Chae, Min-Jeong;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.490-494
    • /
    • 2019
  • Abutment teeth supporting removable partial denture could be faced a number of problems including development of dental caries. If the existing removable partial denture is in clinically acceptable state and the patient does not want to replace the existing removable partial denture, then a new prosthesis for abutment teeth need to be made. The procedure of fabricating a new prosthesis of abutment teeth for existing removable partial denture is complicate and technically challenging. To fabricate the abutment crown, the original cast of patient obtained before any complication to the abutment teeth is required. The original cast should also contain teeth other than the abutment teeth as a reference point. Once the cast is prepared, CAD/CAM could be used to produce retrofitting prosthesis effortlessly and efficiently. This clinical report presents fabricating a crown to fit existing removable partial denture using CAD/CAM for a patient with post and core failure and dislodged prosthesis. The prosthesis had high stability with minimum adjustment yielding satisfying result.

STRAIN ON THE LABIAL PLATES AROUND ABUTMENTS SUPPORTING REMOVABLE PARTIAL DENTURES WITH VARIOUS PROSTHETIC DESIGNS: AN IN VITRO STUDY

  • Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.322-330
    • /
    • 2005
  • Statement of problem. In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress. Purpose. The purpose of this study was to investigate the biomechanical effects of mandibular removable partial dentures with various prosthetic designs using strain gauge analysis. Material and methods. Artificial teeth of both canines were anchored bilaterally in a mandibular edentulous model made of resin. Bilateral distal extension removable partial dentures with splinted and unsplinted abutments were fabricated. Group 1 : Clasp-retained mandibular removable partial denture with unsplinted abuhnents Group 2 : Clasp-retained mandibular removable partial denture with splinted abutments by 6-unit bridge Group 3 : Bar-retained mandibular removable partial denture Strain gauges were bonded on the labial plate of the mandibular resin model, approximately 2 mm close to the abutments. Two vertical experimental loadings (100N and 200N) were applied subsequently via two miniature load cells that were placed at mandibular first molar regions. Strain measurements were performed and simultaneously monitored from a computer connected to data acquisition system. For within-group evaluations, t-test was used to compare the strain values and for between-group comparisons, a one-way analysis of variance (ANOVA) was used and Duncan test was used as post hoc comparisons. Results. Strain values increased as the applied load increased from 100N to 200N for all groups (p<.05). The strain values of group 1 and 2 were tensile under loadings. In contrast, strain values of group 3 were compressive in nature. Under 100N loading, group 1 showed higher strain values than group 3 in absolute quantity (p<.05). Under 200N loading, group 3 showed higher strain values than group 1 and 2 in absolute quantity (p<.05). Group 1 showed higher strain values than group 2 (p<.05). Conclusion. Splinting of two isolated abutments by bridge reduced the peri-abutment strain in comparison with unsplinted abutments. Strain of bar-retained removable partial denture increased much more as applied load increased, but was compressive in nature.

A Telescopic System and Its Clinical Application for the Restoration of the Partially Edentulous Arch (부분 무치악 환자에서 텔레스코프 시스템을 적용한 전악 수복 증례)

  • Shin, Mee-Ran
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.2
    • /
    • pp.139-144
    • /
    • 2007
  • Prosthodontic treatment planning for various edentulous arches is not an easy issue for dentists. Especially, in case of removable partial denture, we must have a knowledge of overall treatment procedures, and a careful approach is needed. Recently, interest of dental implant and case reports are increasing, the decrease of the removable partial denture is true, but dental implantation takes longer treatment period and it is more expensive. Also, there are still some limitations like lack of available alveolar bone, patient's general condition, and chronic periodontitis. Therefore, sometimes implantation is impossible. Finally, implantation cannot be adapted to every single patient. Currently, the clasp type removable partial dentures are used routinely, giving patients many unesthetic and functional difficulties. With better laboratory technique, removable partial denture with attachment and removable partial denture in rigid type increase patient's happiness level much more than predicted. The case presented in this article, clinically demonstrate the efficiency of using a telescopic system to improve esthetic and functional recovery for patients who lose multiple teeth.

A case of treatment denture and implant-assisted removable partial denture in a patient with collapsed occlusion caused by partial loss of posterior and anterior teeth (편측 구치 및 전치 상실로 인한 교합 붕괴 환자에서 치료 의치와 임플란트 보조 국소의치를 이용한 수복 증례)

  • Ahn, Hye-Bin;Lee, Keun-Woo;Lee, Yong-Sang;Yim, Sun-Young;Kim, Sung Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.110-118
    • /
    • 2022
  • Multiple tooth loss can cause disharmonious occlusial plane, loss of vertical dimension and deflection of mandibular movement. Therefore, restoring proper vertical dimension and occlusion in the centric relation is an important treatment goal. Implant-assisted removable partial denture is a recently used clinical technique, because it increases patient satisfaction by improving retention, support, and stability of conventional denture. The objective of this article is to present a case report describing the fabrication of treatment denture and implant assisted removable partial denture using previously placed implants for a patient with partial loss of posterior support and anterior stop.

Clinical application of mandibular removable partial denture using implant-supported surveyed crown: A case report (임플란트 지지 서베이드 금관을 이용한 하악의 가철성 국소의치 수복 증례)

  • Park, Jae-Ho;Min, Byung-Kwee;Yang, Hong-So;Park, Chan;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.154-160
    • /
    • 2018
  • When making conventional removable partial denture for the remaining teeth where the remaining teeth are only on one side, rotation of the denture occurs -in function- on the axis of the connected remaining teeth. If the edentulous portion is long, it becomes harder to obtain retention and stability for the abutment as the importance of the mucous membrane support is elevated. Such movements of denture decrease denture retention and stability, put excessive stress on the abutment, and give bad influence on periodontal health. Therefore, additional implant placement can be of a good choice in gaining additional retention and stability for partial denture. Thus hereby we report this clinical case as successful results were obtained by placing implants symmetrical to the remaining teeth and putting implant-supported surveyed crowns on the implants, allowing the partial denture to be designed to accept varying components and to have suitable path of insertion.

Fabricating retrofit crowns to an existing removable partial denture by CAD-CAM: a case report (CAD-CAM을 이용한 RPD 지대치의 retrofit crown 제작 증례)

  • Hyuksoon Lee;Seong-A Kim;Joo-Hyuk Bang;Sung Yong Kim;Hee-Won Jang;Keun-Woo Lee;Yong-Sang Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.140-145
    • /
    • 2024
  • Removable partial denture wearers are exposed to the risks that remaining teeth get damaged by caries, attritions, erosion, and fracture. In the case of damaged abutment tooth which should fit to Removable partial denture (RPD), the fabrication of surveyed crown is followed by the making of RPD. However, making new denture takes a long time, and needs several processes and costs. Also, patients should get used to new denture. If other abutment teeth and edentulous ridges provide the existing denture with support, retention, and stability, use of existing denture is considered clinically acceptable. In this situation, fabricating retrofit crowns to an existing removable partial denture makes patient use existing denture, cuts costs, and reduces discomfort. In this case, severely worn teeth were restored using monolithic zirconia crown which fit to an existing removable partial denture by CAD-CAM. Moreover, support, retention, and stability of the denture were improved, and both doctor and patient were satisfied with the result.

STUDY ON VERTICAL DISPLACEMENT OF SOFT TISSUE UNDER DISTAL EXTENSION PARTIAL DENTURE BASE BY FUNCTIONAL IMPRESSION (유리단 국소의치의 기능 인상에 의한 연조직의 수직적 변위량에 관한 연구)

  • Lee, Kwang-Hee;Chang, IK-Tai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.21 no.1
    • /
    • pp.59-66
    • /
    • 1983
  • Distal extension partial dentures are supported by both the relatively rigid teeth and the resilient mucosa. So impression techniques of residual alveolar ridge in case of distal extension partial denture have particular importance in order to broad distribution of the masticatory force. McLean recognized the need for recording the tissues supporting distal extension partial denture base in functional form to equalize the resilient and non-resilient support, and this was called functional impression. Many investigators proposed various techniques of the functional impression for a distal extension partial denture, but only a little studies were performed about displacement of soft tissue under distal extension partial denture base. The purpose of this study is to investigate the amount of vertical displacement of the soft tissue under distal extension partial denture base by different functional impression techniques. Impression techniques used were Z.O.P. Impression, Selective Tissue Placement Impression, Functional Relining Impression. Measurement of the vertical displacement of soft tissue were made with Depth Gauge and Measuring Platform. A Anatomic Impression was used as a control. The results were tested statistically using 3 way ANOVA and Scheffe test. The followings were the results obtained from this study. 1. The greatest amount of soft tissue displacement was observed in the center of the retromolar pad. 2. No significant differences were found between the crest of alveolar ridge and the buccal shelf area. 3. The greatest soft tissue displacement was observed in Functional Relining Impression using Iowa wax, and the least displacement was observed in Selective Tissue Placement Impression using murcaptan rubber base. 4. No significant differences were found between finger pressure and biting pressure in Z.O.P. Impression, but greater displacement was observed by biting pressure than finger pressure in Functional Reling Impression.

  • PDF

The Fabrication of Accurate Removable Partial Denture by Analyzing the Failed Cases (실패 증례 분석을 통한 국소의치 제작 시 주의사항)

  • Lee, Ji-Young;Lee, Kyoung-Lok;Heo, Yu-Ri;Son, Mee-Kyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.280-289
    • /
    • 2013
  • Removable partial denture for oral function recovery of partial edentulous patients is a complicated treatment because the dentist should consider both hard tissue and soft tissue. Removable partial denture produced without consideration of precise design for each component and rotation of denture may cause fracture, deformation or loss of abutment teeth. In case of failure to achieve a proper denture, the reason of failure should be analyzed and the result must be applied to later RPD cases. Finding the solutions through the failed denture cases will help patients use their dentures more comfortably and keep their sound residual teeth and tissue longer.

A case of removable partial denture restoration using implant supported surveyed crown in a maxillary edentulous patient (상악 무치악 환자에서 임플란트 지지 서베이드 크라운을 이용한 가철성 국소의치 수복 증례)

  • Seong, Si Young;Choi, Yeon Jo;Ryu, Jae Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.29-36
    • /
    • 2022
  • When planning oral rehabilitation for maxillary edentulous patients, fixed prosthetic restoration using implants, complete denture restoration or overdentures using implants can be considered as treatment methods. In the case of complete denture restoration, it does not require additional surgery and is relatively economical. In the case of implant-supported fixed prostheses, the functional part is generally superior to that of complete denture restoration, but there are cases in which implant placement is clinically difficult. Recently in consideration of the patient's needs and the condition of the remaining alveolar bone, after partial implant placement, a method of restoring with a removable partial denture using implant-supported surveyed crown is also being attempted. This case is a case of performing a removable partial denture restoration using implant-supported surveyed crown in the anterior maxilla, and showing satisfactory esthetic and functional results.