• Title/Summary/Keyword: Partial defect

Search Result 447, Processing Time 0.027 seconds

Clinical study of endocardial cushion defect: 37 cases report (심내막상 결손증에 대한 임상고)

  • Jo, Jae-Il;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.657-665
    • /
    • 1984
  • Thirty-seven patients had undergone repair of a endocardial cushion defect between 1977 and Aug. 1983 in Seoul National University Hospital. Twenty eight had a partial defect, one intermediate defect and eight complete endocardial cushion defect. Tricuspid cleft was found in 4 cases and mitral cleft was in all p-ECD. Seven patients were of type C anatomy in c-ECD. Four patients had associated major anomalies, including three TOF in c-ECD, one coarctation in p- ECD. In p-ECD patients, the septal defect was closed with patch in all cases and the atrioventricular valvular insufficiency was corrected with MVR in 4 cases, TVR in 1 case and simple interrupted sutures in remainders. In c-ECD patients the septal defect was closed with single patch except one case. The atrioventricular valve was repaired with simple interrupted sutures except one MVR and TVR case. The operative mortality was 14.2% in p-ECD, 44.4% in c-ECD, but recent 3 years [1980-1983] mortality was 8.7% in p-ECD, 20% in c-ECD. More than grade III systolic regurgitant murmur was oted postoperatively in 4 cases of c-ECD and 3 cases of p-ECD. The operative risk factors were preoperative NYHA classification, cyanosis, Rp/Rs, systolic pressure of main pulmonary artery and the degree of regurgitation of atrioventricular valves. The causes of death were low cardiac output syndromes, pulmonary complications and arrhythmias.

  • PDF

Partial Conductivities, Nonstoichiometry and Defect Structure of a New Cathode Candidate $Y_{1-x}Ca_xFeO_{3-\delta}$

  • Kim, Chan-Soo;Yoo, Han-Ill
    • The Korean Journal of Ceramics
    • /
    • v.4 no.2
    • /
    • pp.151-155
    • /
    • 1998
  • The total electrical conductivity, ionic conductivity, and nonstoichimetry of a new cathode material $Y_{1-x}Ca_xFeO_{3-\delta}$ (x=0.1) were measured as functions of temperature ($900\leqT/^{\circ}C\leq1100$) and oxygen partial pressure $(10^{-6}\leqPo_2/atm\leq0.21$). Isothermal variations of these properties with $Po_2$ support that the majority type of ionic defects are anti-Frenkel disorder which, however, has seldom been considered for perovskite-based oxides. The results are discussed in comparison with those reported on similar oxides.

  • PDF

Phase Distribution of Partial Discharge Pulses for Tracking Defect in a CNCO-W Cable (트래킹 결함을 갖는 CNCO-W 케이블에서 부분방전펄스의 위상분포)

  • Cha, Sang-Wook;Park, Dae-Won;Cha, Hyeon-Kyu;Cho, Hyang-Eun;Kil, Gyung-Suk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.185-185
    • /
    • 2011
  • CNCO-W 케이블의 절연결함 형태의 추정을 위해 곡률반경은 10 ${\mu}m$의 침(needle) 및 트래킹(tracking) 결함을 모의하고 부분방전 펄스의 위상분포를 분석하였다. 트래킹 결함에서는 $40^{\circ}{\sim}120^{\circ}$$200^{\circ}{\sim}285^{\circ}$에 분포하였으며, 침 결함과 비교하여 트래킹 결함에서는 펄스수가 증가하였으며, 정극성에서 넓게 분포하였다.

  • PDF

Characteristics of Ultrasonic Signal by Defect types in the Transformer (변압기내 결함의 종류에 따른 부분방전의 초음파신호 특성 분석)

  • 박현수;진상범;곽희로;권동진;박하용
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.296-298
    • /
    • 1999
  • Out of the defects occurred in a transformer, the cases of protrusion and surface discharge were simulated by using needle-plane and IEC(B) electrode. The waveform and frequency characteristics of ultrasonic signals due to partial discharge occurred at each electrode were analyzed. And then, the ultrasonic signal characteristics from the partial discharge due to the two kinds of defect were compared. As a result, in the case of the protrusion and surface discharge, the waveforms were similar, but the frequency spectra were different.

  • PDF

Transport Mechanisms of Holmium Sesquioxide-Yttrium Sesquioxide System

  • Kim, Keu-Hong;Choi, Jae-Shi;Park, Sung-Ho;Won, Hui-Jun
    • Bulletin of the Korean Chemical Society
    • /
    • v.6 no.1
    • /
    • pp.11-15
    • /
    • 1985
  • Electrical conductivites of polycrystalline yttrium sesquioxides containing 1.6 and 3.2 mol % of holmium sesquioxdes have been measured from 650 to $1050^{\circ}C$ under oxygen partial pressures of $1{\times}10^{-5}$ to $2{\times}10^{-1}$ atm. Plots of log conductivity vs. 1/T at constant oxygen partial pressures are found to be linear away from the two inflection points. The low- and high-temperature dependences of conductivity show different defect structures of yttrium sesquioxide. The plots of log conductivity vs. log $PO_2$ are found to be linear at $PO_{2'}$s of $10^{-5}$ to $10^{-1} atm. The electrical conductivity dependences on $PO_2$ are found to be $1}5.3$ at $950-1050^{\circ}C$, $\frac{6}{1}$ at $800-950^{\circ}C$ and ($\frac{6.2}{1}$) - ($\frac{6.5}{1}$) at $650-800^{\circ}C$, respectively. The defect structures and conduction mechanisms have been suggested.

Triqubit-State Measurement-Based Image Edge Detection Algorithm

  • Wang, Zhonghua;Huang, Faliang
    • Journal of Information Processing Systems
    • /
    • v.14 no.6
    • /
    • pp.1331-1346
    • /
    • 2018
  • Aiming at the problem that the gradient-based edge detection operators are sensitive to the noise, causing the pseudo edges, a triqubit-state measurement-based edge detection algorithm is presented in this paper. Combing the image local and global structure information, the triqubit superposition states are used to represent the pixel features, so as to locate the image edge. Our algorithm consists of three steps. Firstly, the improved partial differential method is used to smooth the defect image. Secondly, the triqubit-state is characterized by three elements of the pixel saliency, edge statistical characteristics and gray scale contrast to achieve the defect image from the gray space to the quantum space mapping. Thirdly, the edge image is outputted according to the quantum measurement, local gradient maximization and neighborhood chain code searching. Compared with other methods, the simulation experiments indicate that our algorithm has less pseudo edges and higher edge detection accuracy.

Analysis on Partial Discharge Fault Signals of PRPD for High Voltage Motor Stator Winding (고압전동기 고정자 권선의 PRPD 부분방전 결함신호 해석)

  • Park Jae-Jun;Lee Sung-Young;Mun Dae-Chul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.10
    • /
    • pp.942-946
    • /
    • 2006
  • We simulated insulation defects of stator winding wire on high voltage generator by 5 types. 4 types have one discharge source and other one has multi discharge source by simulation. For accurate decision, measurements used to PRPD pattern to occurred partial discharge source of various types. In this research, when PRPD pattern carried out or analyzed pattern recognition of discharge source, it used to powerful tools. In this result, PRPD Pattern defined to have single discharge source of 4 types by insulation defect. When insulation defect simulated, all the defected winding have not the same result. Errors for a little different can make mistakes from a subtle distinction. The difference between internal and void discharge have magnitude of pulse amplitude of inner discharge bigger than void discharge and have a shape of bisymmetry. But void discharge has a shape of bisymmetry against maximum value on polarity respectively. In cases of slot and surface discharge, we confirmed to show similar results those other researchers. In case of multi-discharge, as a result of we could classify not perfect match with occurred patterns in single discharge eachother. In the future, we will have to recognize and classify with results of multi-discharge.

Partial Discharge Pattern Recognition of Cast Resin Current Transformers Using Radial Basis Function Neural Network

  • Chang, Wen-Yeau
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.293-300
    • /
    • 2014
  • This paper proposes a novel pattern recognition approach based on the radial basis function (RBF) neural network for identifying insulation defects of high-voltage electrical apparatus arising from partial discharge (PD). Pattern recognition of PD is used for identifying defects causing the PD, such as internal discharge, external discharge, corona, etc. This information is vital for estimating the harmfulness of the discharge in the insulation. Since an insulation defect, such as one resulting from PD, would have a corresponding particular pattern, pattern recognition of PD is significant means to discriminate insulation conditions of high-voltage electrical apparatus. To verify the proposed approach, experiments were conducted to demonstrate the field-test PD pattern recognition of cast resin current transformer (CRCT) models. These tests used artificial defects created in order to produce the common PD activities of CRCTs by using feature vectors of field-test PD patterns. The significant features are extracted by using nonlinear principal component analysis (NLPCA) method. The experimental data are found to be in close agreement with the recognized data. The test results show that the proposed approach is efficient and reliable.

Partial Discharge Diagnosis of Interface Defect by the Distribution Statistical Analysis (분포 통계 해석에 의한 계면 결함 부분방전 진단)

  • Cho, Kyung-Soon;Lee, Kang-Won;Kim, Won-Jong;Hong, Jin-Woong;Shin, Jong-Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.4
    • /
    • pp.348-353
    • /
    • 2008
  • Most of the high voltage insulation systems, such as the power cable joint having hetero interface, are composed of more than two different insulators to improve insulating performance. The partial discharge(PD) in these hetero interface is expected to affect the total insulation performance. Thus, it is important to study electrical properties on these interfaces. This study described the influence of copper and semiconductive substance defects on $\Phi$-q-n distribution between the interface of the model cable joints to classify PD source. PD was sequentially detected for 600 cycles of the applied voltage. The K-means cluster analysis has been analyzed to investigate the $\Phi$-q-n distribution. The skewness-kurtosis(Sk-Ku) plot from K-means clustering results was defined to quantify cluster distribution and classify distribution patterns. The Sk-Ku plot is composed of skewness and kurtosis along abscissa and ordinate which indicate the asymmetry and the sharpness of distribution. As a result of the Sk-Ku plot, it was confirmed that the data was distributed in 1st 2nd and 3rd quadrant at copper foreign substance defect, but in case of semiconductive foreign substance, the data was distributed in 2nd quadrant only.

Analysis of Partial Discharge Inception Voltages for the Wrong Positioning Defects in the Joint of Distribution Power Cables

  • Kim, Jeong-Tae;Kim, Dong-Uk;Lee, Young-Jo;Koo, Ja-Yoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.977-982
    • /
    • 2012
  • In order to find out partial discharge (PD) phenomena in the cable joint due to the poor workmanship during the installation, the relationship between PD inception voltages and joint defects was investigated. For the purpose, in the joint of 22.9kV CNCV cables, electric fields were calculated for various semiconductive layer wrong positioning (WP) defects. And, PDIV were investigated through the experiments and compared with the results of electric field analysis. In all WP defect cases, the PD inception field calculated using measured PDIVs was similarly shown to be the average value of 1.84kV/mm. In addition, the calculated PDIV and the measured PDIV were almost equal, from the PDIV calculation using maximum electric fields and the measured PDIV for the normal case. Throughout this study, it is possible to analyze WP defects due to the poor workmanship and to establish better joint design for the distribution grade extruded cable system.