• Title/Summary/Keyword: Partial Volume Effect

Search Result 116, Processing Time 0.02 seconds

A study on the apparent and partial molal volumes of n-Alkyl amine hydrochloride in water (n-Alkyl amine 鹽酸鹽의 水溶液 中에서의 apparent 및 partial molal volumes에 관한 硏究)

  • Yoon Sang Ki
    • Journal of the Korean Chemical Society
    • /
    • v.13 no.2
    • /
    • pp.121-129
    • /
    • 1969
  • The apparent and partial molal volumes({\phi}\nu$and $V^{\circ}$) of a series of homologous n-alkylamine hydrochlorides $C_nH_{2n+1}NH_3^+Cl^-$, where n varies from zero to four, have been determined by means of a float method at 30$^{\circ}C$ to the fifth decimal place down to 0.01M in aqueous solutions. The experimental results indicate that the partial molal volumes of the salts are almost additive for successive homologues depending on the increment of molecular weight ($CH_2$). It has been observed that the concentration dependence of the ${\Phi}v$ are linear in general and limiting slopes are positive and relatively close to the theoretical values. Anionic partial molal volume of chlorides anion $V^{\circ}_{Cl^-}$ is found to be 18.6 ml $mole^{-1}$, which is in good agreement with the results of other workers. {\phi}\nu$ data also show that in solution the hydrophobic effect of ions are in competition with the charge effect, but the latter, that is, electrostriction seemed to be considerably predominant.

  • PDF

An Electronic Colon Cleansing Method using a Patient Colon CT Profile (환자 대장 CT 프로파일을 이용한 전자적 장세척 방법)

  • Kim, Han-Byul;Kim, Dong-Sung
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.8
    • /
    • pp.493-500
    • /
    • 2008
  • This paper proposes an electronic colon cleansing method using a patient CT profile for a virtual colonoscopy. The proposed method extracts the colon using cubic seeded region growing, and removes tagged materials adjacent to the colon. Residuals produced by a partial volume effect at the boundary of air-tagged material are deleted, and the removed soft tissue pixels due to a partial volume effect at the boundary of tagged material-soft tissue are recovered using a patient CT profile. The proposed method was applied to 16 virtual colonoscopy patient data sets, and produced promising results by a subjective evaluation of a radiologist and by a quantitative evaluation of a computer-aided diagnosis system.

MR-based Partial Volume Correction for $^{18}$F-PET Data Using Hoffman Brain Phantom

  • Kim, D. H.;Kim, H. J.;H. K. Jeong;H. K. Son;W. S. Kang;H. Jung;S. I. Hong;M. Yun;Lee, J. D.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.322-323
    • /
    • 2002
  • Partial volume averaging effect of PET data influences on the accuracy of quantitative measurements of regional brain metabolism because spatial resolution of PET is limited. The purpose of this study was to evaluate the accuracy of partial volume correction carried out on $^{18}$ F-PET images using Hoffman brain phantom. $^{18}$ F-PET Hoffman phantom images were co-registered to MR slices of the same phantom. All the MR slices of the phantom were then segmented to be binary images. Each of these binary images was convolved in 2 dimensions with the spatial resolution of the PET. The original PET images were then divided by the smoothed binary images in slice-by-slice, voxel-by-voxel basis resulting in larger PET image volume in size. This enlarged partial volume corrected PET image volume was multiplied by original binary image volume to exclude extracortical region. The evaluation of partial volume corrected PET image volume was performed by region of interests (ROI) analysis applying ROIs, which were drawn on cortical regions of the original MR image slices, to corrected and original PET image volume. From the ROI analysis, range of regional mean values increases of partial volume corrected PET images was 4 to 14%, and average increase for all the ROIs was about 10% in this phantom study. Hoffman brain phantom study was useful for the objective evaluation of the partial volume correction method. This MR-based correction method would be applicable to patients in the. quantitative analysis of FDG-PET studies.

  • PDF

College Students' Misconception about the Volume Change of Solution during Acid/Base Titration: Partial Molar Volume of Salt (산·염기 적정에서 용액의 부피 변화에 대한 대학생들의 오개념 연구)

  • Jang, Nak Han
    • Journal of Science Education
    • /
    • v.33 no.2
    • /
    • pp.317-320
    • /
    • 2009
  • I investigated Korean college students' conception about the volume change of solution when they detected the equivalence point during acid/base titration experiment using method of volume measurement. According to this study, most college students had a misconception that the volume increment was due to the formation of water by neutralization during acid/base titration. However, this is not enough to explain the volume change, neglecting contribution of a salt in solution. I calculated the partial molar volume of NaCl formed to explain the volume increment of solution during HCl/NaOH neutralization. Comparing the result of experiment with the calculation of partial molar volume, I elucidated that the main effect of volume increment was due to the partial molar volume of NaCl formed during HCl/NaOH neutralization. Here I propose to introduce college students to the concept of partial molar volume of the salt formed to reduce misconception about the volume change of solution during acid/base neutralization.

  • PDF

Electrical Insulation Characteristics at Cryogenic Temperature for High Temperature Superconducting Cables

  • Okubo, Hitoshi;Hayakawa, Naoki
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.1
    • /
    • pp.15-20
    • /
    • 2004
  • This paper discusses electrical insulation characteristics at cryogenic temperature, especially focusing on partial discharge (PD) inception characteristics, for high temperature superconducting cables. In liquid nitrogen (L$N_2$) / polypropylene (PP) laminated paper composite insulation system, PD inception strength (PDIE) was evaluated in terms of volume effect and V-t characteristics. Different kinds of butt gap condition were applied in the experiments, using parallel plane and coaxial cylindrical cable samples. Experimental results revealed that the volume effect on PDIE could be evaluated by the statistical stressed liquid volume (SSLV) taking account the discharge probability not only in the butt gap but also in the other thin layers between PP laminated papers. Furthermore, the indices n of V-t characteristics at PD inception were estimated to be 80∼110, irrespective of the butt gap condition.

Effect of partial pyloric obstruction on body weight, gastric juice, gastric surface area and gastric edema in normal intact rats and/or vagotomized rats (정상 및 미주신경절단 흰쥐의 체중, 위액 분비량, 위의 형태변화에 대한 위 유문부 부분폐색과 재개통의 효과)

  • Seon, Jong-Ki;Yoon, Sang-Hyub
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.1
    • /
    • pp.26-38
    • /
    • 2012
  • Objectives : The aim of this study was to investigate the effect of partial pyloric obstruction on body weight, gastric juice, gastric surface area and gastric edema in normal intact and/or vagotomized rats. Methods : Partial pyloric obstruction was performed by wrapping a non-absorbable rubber ring (D:6 mm, W:4 mm, T:1 mm) around the 1st portion of the duodenum. Vagotomy was performed by resecting the branches around the esophagogastric junction. Pre-post body weight differential, fasting gastric juice volume, gastric surface area and gastric edema were measured at 8 weeks and 20 weeks. For the effect of pyloric reperfusion the rubber ring was removed after 8 weeks and then an additional 12 weeks of observation was performed to the end of the 20-week experimental period. Results : In the initial 8 weeks observation, the effect of pylorus obstruction and/or vagotomy was significantly remarkable in the pylorus obstructed and vagotomized group; slowdown of weight gain, increase of fasting gastric juice volume, dilatation of gastric surface area and severe gastric edema were shown. In the remaining 12 weeks observation, the effect of reperfusion was significantly remarkable in the ring-removed antral dilated group; recovery of weight gain, decrease of gastric surface area and decrease of gastric edema were shown. However, gastric juice volume was not significantly different from the other group. Conclusions : Partial pyloric obstruction plays a aggravating role and the vagus nerve plays a protective role in body weight, gastric juice, gastric surface area, and gastric edema. Furthermore, pyloric valve dysfunction as an aggravating factor strengthened in defect of the vagus nerve. These results suggest that patients with both functional pyloric outlet obstruction and hypofunction of vagus nerve need to be diagnosed in good time and treated properly.

Implementation of Filter for the Removal of Partial Volume Effect (부분용적효과 제거를 위한 Filter 구현)

  • Park, Minju;Lee, Sangbock
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.139-145
    • /
    • 2015
  • When examining a patient using SPECT, gamma rays emitted from the body decrease or scatter. And when they reach the detector they spread in accordance with physical characteristics and geometric shapes of the scanner, quantitative analysis was difficult. For exact quantitative analysis of gamma rays emitted from the body, so that they must be considered to correction about PVE(partial volume effect). In this paper, sinogram filter was implemented to solve comprehensive PVE of SPECT. According to the results in which implemented filter was applied, partial volume effect caused by SPECT was removed. To compare proposed method and conventional method, PSNR(Peak Signal to Noise Ratio) was executed. As a result, proposed method was indicated as 7dB, conventional method was indicated as 14db respectively. dB(decibel) level of the proposed methods is lower, since the MSE(mean square error) becomes greater because scattered ray was removed, PSNR value is low. Therefore, by applying the proposed method for removing the PVE of SPECT imaging method, the image quality is improved.

Partial molal volumes of n-alkylamine hydrochlorides in methanol-water mixtures (메탄올-물 혼합액에서의 n-Alkylamine 염산염의 분 몰랄 부피)

  • Uhm, Tae-Sup;Yoon, Sang-Ki;Lee, Ik-Choon
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.51-59
    • /
    • 1970
  • The apparent molal volumes(${\phi}_v$) of the homologous salts $RNH_3Cl$, where R varies from methyl-($CH_{3^-}$) to n-butyl-(n-$C_4H_{9^-}$) in a series of methanol-water mixtures have been determined at 30$^{\circ}C$ by means of a float method to fifth decimal places down to 0.01 m. The values of ${\phi}_r$ extrapolated to infinite dilution give partial molal volumes $\bar{V}^{\circ}$which varies considerably in accordance with the solvent composition. that is, mole fraction of methanol. The experimental results are discussed in terms of the varying size and charge effect, hydrophobic nature of the solute species, and also the additivity relationship between successive homologous and the structure of the binary solvent. The results indicate that at 0.1 mole fraction methanol the enhanced structuredness of water cause a minimum in the partial molal volumes of cations $\bar{V}^{\circ}_+$, while at 0.4 mole fraction the solvent structure is such that the free volume is a minimum but the effect of electrostriction is a maximum.

  • PDF

ROI Study for Diffusion Tensor Image with Partial Volume Effect (부분용적효과를 고려한 확산텐서영상에 대한 관심영역 분석 연구)

  • Choi, Woohyuk;Yoon, Uicheul
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.84-89
    • /
    • 2016
  • In this study, we proposed ameliorated method for region of interest (ROI) study to improve its accuracy using partial volume effect (PVE). PVE which arose in volumetric images when more than one tissue type occur in a voxel, could be used to reduce an amount of gray matter and cerebrospinal fluid within ROI of diffusion tensor image (DTI). In order to define ROIs, individual b0 image was spatially aligned to the JHU DTI-based atlas using linear and non-linear registration (http://cmrm.med.jhmi.edu/). Fractional anisotropy (FA) and mean diffusivity (MD) maps were estimated by fitting diffusion tensor model to each image voxel, and their mean values were computed within each ROI with PVE threshold. Participants of this study consisted of 20 healthy controls, 27 Alzheimer's disease and 27 normal-pressure hydrocephalus patients. The result showed that the mean FA and MD of each ROI were increased and decreased respectively, but standard deviation was significantly decreased when PVE was applied. In conclusion, the proposed method suggested that PVE was indispensable to improve an accuracy of DTI ROI study.

Comparison of Recovery Coefficients for Correction of Reduced SUV by Partial Volume Effect and Organ Movements in PET/CT Images (PET/CT 영상의 부분체적효과와 장기의 움직임으로 인해 감소된 SUV의 보정을 위한 회복계수의 비교)

  • Kim, Youngjae;Park, Hoon-Hee;Lee, Joo-Young;So, Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.241-248
    • /
    • 2022
  • In this study, a recovery coefficient (RC) calculation was conducted that can correct the underestimation of the standardized uptake value (SUV) due to the partial volume effect (PVE) through phantom measurements and formulas. The experiment was conducted using a dynamic phantom capable of implement cranio-caudal movement at a respiratory rate of 15 times per minute along with the measured phantom experiment of the stopped state, and the RC of the moving state is calculated and compared. Ingenuity TF (Philips Healthcare, Netherland) was used as a positron emission tomography/computed tomography (PET/CT) device. PET-CT Phantom (Biodex Medical System, USA) was used as a phantom for measurement. A phantom image in a stationary state was acquired, and a moving phantom image was acquired using the AZ-733V Respiratory Phantom (Anzai Medical Co, Japan) capable of breathing movement in the cranio-caudal direction under the same acquisition parameters. For RC calculation, the sphere maximum radioactivity concentration and the background mean radioactivity concentration of the acquired images were measured, and the initially determined sphere and background radioactivity concentrations were calculated. The calculated RC was 0.08 to 0.72. The size of sphere smaller, it was confirmed that the RC reduced. And the RC in the moving state reduced than in the stationary state. As a result of this study, the change of the RC was confirmed according to the size of spheres and the phantom moving. Using the RC derived by implement movement of breathing with the respiratory phantom, it is possible to considering correction of underestimated SUV by the partial volume effect of PET images and the patient movements.