• 제목/요약/키워드: Partial Discharges

검색결과 206건 처리시간 0.035초

GIS내 PD 종류에 따른 UHF신호의 특성연구 (A study on the UHF signal Characteristics by two kinds of PD in GIS)

  • 송현석;이재화;장덕근;이동준;곽희로
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.251-255
    • /
    • 2002
  • This paper describes the analysis of UHF signals taking place at partial discharges due to defects in GIS. To imitate the defects, two kinds of electrode were employed. One is to generate the PD due to corona discharge, and the other surface discharge. As a result, the magnitude of the UHF signals acquired from the discharges increased with the applied voltage. However, each frequency distribution trend at corona discharges and surface discharge was similar even though the applied voltage increased. Frequency distribution between corona discharge and surface discharge was clearly distinguish.

  • PDF

전극 형태에 따른 기중 부분 방전의 양상 해석 (Analysis of Partial Discharges according to Electrode Types in Air)

  • 박정남;이강원;이청;박영국;이홍규;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1543-1545
    • /
    • 2001
  • In general, corona discharges in air are accompanied with electromagnetic wave which has wide frequency range up to UHF and can be detected by rod or loop antennas. But the existence of background noises such as TV, radio or electronic disturbances makes it difficult to separate corona discharge signals from them in the outside fields. The results of experiment using wideband antenna (30kHz - 2GHz) show that corona discharges have dependences on electrode types and independences on background noises.

  • PDF

고체절연체 계면에서 부분방전 패턴의 열화에 따른 변화특성 (The Characteristics of PD Patterns due to the Aging at the Interface between Solid Insulators)

  • 이우영;선종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1725-1727
    • /
    • 1998
  • In this paper the patterns of partial discharges(PD) occurred from some defects at the interface of cable joints as the function of the phase of the applied voltage were investigated in order to discern the kind of a defect. The results obtained in this study show that it is possible to distinguish the PD patterns between the void discharges and the treeing or tracking discharges which were occured at the cable joint interface. While the state of defect transfers from a void discharge into a tree or tracking discharge with a aging time, the skewness for both half of the applied voltage cycle is observed to go to the negative value.

  • PDF

부분방전 펄스특성을 이용한 TF Map에 대한 고찰 (Considerations on the TF Map using Partial Discharge Pulse Characteristics)

  • 김정태;김남준;장용무;김지홍;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2126-2128
    • /
    • 2005
  • In this paper, it was investigated the applicability of TF analysis for the discrimination of air corona in on-site PD measurement. For the purpose, single and multiple discharges combined with oil discharges and air corona were generated and measured by use of artificial models and HFPD pulse detector. Through the TF analysis, data clusters could be classified each other in the TF Map, even in the case of multiple discharges. Therefore, it is known that TF analysis could be applied for the improvement of on-site PD measurement.

  • PDF

대용량 터빈발전기 고정자 권선의 정지중 및 운전중 부분방전 특성 (Off-Line and On-Line Partial Discharge Properties of Large Turbine Generator)

  • 김희동;이영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1846-1849
    • /
    • 2000
  • Off-line and on-line partial discharges were measured on a 828MVA, 22kV and direct hydrogen-cooled large turbine generator. Partial discharge tests were conducted using digital partial discharge detector(PDD) and turbine generator analyzer(TGA). PDD and TGA showed that off-line partial discharge pattern seems to be very, similar to that found with on-line. Most of the partial discharge is originating with the stator slot in the three phases. As the partial discharge activity is very low, the stator insulation condition of this generator is very good.

  • PDF

수력발전기 고정자 권선에서 부분방전 특성 (Partial Discharge Property of Hydrogenerator Stator Windings)

  • 김희동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.86-90
    • /
    • 2000
  • Partial discharge(PD) tests were performed when the hydrogenerator(rated 11kV and 25MVA) was shut down(off-line). Six cable couplers were installed in the ring bus as well as within hydrogenerator terminal box. PD tests were conducted using partial discharge analyzer(PDA) and digital partial discharge detector(PDD). PDA showed that the normalized quantity number(NQN) and the partial discharge magnitude increased with increase of ac voltage. Slot discharges were discovered in three phases(A, B and C) at the rated voltage. PDA and PDD test results are in accordance with the pattern and magnitude of partial discharge. This hydrogenerator stator windings were in good condition.

  • PDF

안테나를 이용한 부분방전의 진단기병에 관한 연구 (The Diagnosis technique of Partial Discharges using Antenna)

  • 김영노;김재철;전영재;서인철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.217-219
    • /
    • 2001
  • This paper presents new diagnosis technique for detecting a partial discharge(PD) using antenna. The wavelet transform is applied for the analysis of PD pulse signal because it is difficult to identify PD signal using electromagnetic waves detected by antenna. The capabilities of the proposed diagnosis methodology for detecting PD signal is verified on experiment in laboratory.

  • PDF

GIS 내 금속입자의 부상전압과 부분방전특성 연구 (Lift-Off Voltage and Partial Discharge Characteristics of Free Metallic Particles in GIS)

  • 윤진열;한상옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권2호
    • /
    • pp.127-132
    • /
    • 1999
  • Both motion of free metallic particles from which most GIS internal failures are caused and partial discharges from the particles were examined using EHV GIS test chamber. Effects from particle length and gas pressure which are main factors to lead to breakdown failure were investigated theoretically and experimentally. Magnitude of both lift-off voltage and partial discharge inception voltage were measured respectively and, through these measurements, this paper showed the possibility of predicting breakdown fault and of taking action to prevent the fault in advance. The measurement of partial discharge when the particles began to move could be adopted to decide minimum sensitivity in developing predictive diagnostic equipments. Both the amount of apparent discharge and real discharge in GIS were examined theoretically and experimentally, then experimental results were analyzed on the basis of the theory.

  • PDF

가교폴리에틸렌(XLPE)의 부분방전에 의한 초음파 검출 (Detection of Ultrasonic Wave Signals Associated with Partial Discharge in XLPE)

  • 김성규;이상우;구경철;김충년;김인식;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.136-140
    • /
    • 1999
  • Measurements of AE signals caused by partial discharges were performed by using an ultrasonic measurement technique to diagonise the electrical treeing deterioration in XLPE cable. We also examined the partial discharge magnitude and AE signals(peak-to-peak) with the increase of the deterioration time. From these results, it was found that AE signal due to partial discharge can be greatly detected at the peak value of positive polarities prior to the breakdown voltages, and the magnitude of AE signals was closely related to the current pulses by the increase of deterioration, and it appeared that AE signals(peak-to-peak) was proportional to partial discharge magnitude. Attenuation and time-delaying characteristics of ultrasonic signals propagated in various polymers sample by using ultrasonic oscillation and receiving systems are also reported as a basic data of ultrasonic measurements in XLPE cable.

  • PDF

고압 전동기 고정자 권선의 활선 부분방전 모니터링 기술개발 (Development of On-Line Partial Discharge Monitoring Techniques for Stator Winding of High-Voltage Motors)

  • 황돈하;이주훈;강동식;김용주;이재영;신병철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.43-46
    • /
    • 2004
  • Recently many research activities on the diagnosis of stator winding insulation of high-voltage motors have been reported. Most of them utilize a trend analysis of partial discharges. In this paper, a novel on-line monitoring system for an insulation diagnosis is proposed. This system displays magnitude and phase angle distribution of partial discharge. The partial discharge activities can be interpreted more precisely by these techniques.

  • PDF