• Title/Summary/Keyword: Parotid

Search Result 502, Processing Time 0.024 seconds

An Outbreak of Mumps in Taejon. Korea. 1998 (1998년 대전지역에서 유행한 볼거리의 임상적 연구)

  • Kang, Hee-Dong;Lee, Kyung-Yil;Cha, Sang-Won;Yoon, Kye-Nam;Lee, Dong-Joan;Han, Ji-Whan;Kang, Jin-Han;Whang, Kyung-Tai
    • Pediatric Infection and Vaccine
    • /
    • v.6 no.2
    • /
    • pp.239-244
    • /
    • 1999
  • Purpose : In 1998, there was an outbreak of mumps in Taejon, Korea. We analyzed the monthly incidence, clinical manifestations, and complications during the outbreak and the annual incidence of the recent ten years. Methods : We reviewed the clinical records of 35 mumps patients who had been admitted to Taejon St. Mary's Hospital from January to December, 1998. Results : Mumps was prevalent in summer(from June to August) with 20 cases(57%). Thirthy-three patients(94.3%) received MMR at 15 months of age and no patients received a booster mumps vaccine. The mean age of the mumps patients was 10.5 years-old and the majority of mumps(71%) occurred between 5 and 12 year of age. The male female ratio was 2.2 : 1. The clinical manifestations were swelling of parotid gland(100%), fever (91%), vomiting(77%), abdominal pain(74%) and headache(66%) in order of frequency. Meningitis occurred in 20 cases(57%) and the mean WBC count of CSF was $464{\pm}263/mm^3$. In serology, the mean serum amylase level was $483{\pm}294IU/dL$ and anti-mumps IgM and IgG were positive in 11 and 15 out of 18 cases, respectively. From 1989 to 1997, the mean number of inpatients with mumps was 3.4 per year. Conclusion : We experienced an outbreak of mumps in 1998. It is suggested that there was a primary mumps vaccine failure in Korea and that further studies for vaccine faiure and method of booster mumps vaccine are necessary.

  • PDF

Usefulness of the quantitative analysis by using the functional parameter index from dynamic salivary glands scintigraphy (동적 타액선 신티그라피에서 기능적 매개변수 지표를 활용한 정량 분석의 유용성)

  • Shin, Chae Ho;Kim, Bong Su;Cho, Yong Gyi;Jo, Jin Woo;JIn, Sung Eun;Pyo, Sung Jai
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.81-86
    • /
    • 2015
  • Purpose This study was to evaluate the usefulness through the comparison of patients group and healthy control group by acquiring a variety of functional parameters index from time-activity curves of salivary gland scintigraphy using $^{99m}Tc$. Materials and Methods From December 2014 to February 2015 with the targets of 30 patients in the patient group who presented themselves with xerostomia and underwent the salivary gland scan and 10 people in healthy control group, approximately 30 minutes of dynamic Scan was carried out after the intravenous bolus injection of 370 MBq of $^{99m}TcO_4{^-}$ and per os stimulation with Vitamin C powder 20 minutes after the injection. The method of quantitative analysis was as follows, the time-activity curve was drawn after the parotid gland and submandible gland were prescribed as a region of interest, a variety of functional parameters index was obtained in each position of the curve, and the patients group and the control group were compared. Results As for the methods applied in comparison and measurement, uptake ratio (UR), time at maximum counts (Tmax), time at minimum counts (Tmin), maximum accumulation (MA), accumulation velocity, maximum secretion (MS), maximum stimulation secretion (MSS), and secretion velocity (SV) were used. In the comparison of functional parameters index of patient group and normal group, the healthy normal group showed significant difference compared to the patient group in all indices except for the minimum radioactivity time (Tmin), and also in terms of variation over time the normal group showed significant difference compared to the patient group (p<0.05). Conclusion Consequently, it was considered that the quantitative analysis that used a variety of functional parameters index would be useful for evaluating the function of the salivary glands of the patients with xerostomia as an objective and standardized information.

  • PDF

The Evaluation of Composite Dose using Deformable Image Registration in Adaptive Radiotherapy for Head and Neck Cancer (두경부 종양의 적응방사선치료시 변형영상정합을 이용한 합성선량 평가)

  • Hwang, Chul-Hwan;Ko, Seong-Jin;Kim, Chang-Soo;Kim, Jung-Hoon;Kim, Dong-Hyun;Choi, Seok-Yoon;Ye, Soo-Young;Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.36 no.3
    • /
    • pp.227-235
    • /
    • 2013
  • In adaptive radiotherapy(ART), generated composite dose of surrounding normal tissue on overall treatment course which is using deformable image registration from multistage images. Also, compared with doses summed by each treatment plan and clinical significance is considered. From the first of May, 2011 to the last of July, 2012. Patients who were given treatment and had the head and neck cancer with 3-dimension conformal radiotherapy or intensity modulated radiotherapy, those who were carried out adaptive radiotherapy cause of tumor shrinkage and weight loss. Generated composite dose of surrounding normal tissue using deformable image registration was been possible, statistically significant difference was showed to mandible($48.95{\pm}3.89$ vs $49.10{\pm}3.55$ Gy), oral cavity($36.93{\pm}4.03$ vs $38.97{\pm}5.08$ Gy), parotid gland($35.71{\pm}6.22$ vs $36.12{\pm}6.70$ Gy) and temporomandibular joint($18.41{\pm}9.60$ vs $20.13{\pm}10.42$ Gy) compared with doses summed by each treatment plan. The results of this study show significant difference between composite dose by deformable image registration and doses summed by each treatment plan, composite dose by deformable image registration may generate more exact evaluation to surrounding normal tissue in adaptive radiotherapy.

Study of overlapping setting up of Planning Target Volume for Improving Target Coverage adjacent Organ At Risk (손상위험장기에 인접한 표적 Coverage 개선을 위한 Planning Target Volume 중복 설정에 관한 연구)

  • Lee, Jung Woong;Kim, Bo Kyum;Mun, Jun Ki;Woo, Hun;Lee, Yang Hoon;Jeon, Chang Woo;Lee, Jea Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.33-41
    • /
    • 2019
  • Purpose: The purpose of this study is to improve the reduction of coverage of PTVs adjacent to organ at risk (OAR) by setting up overlapping Planning Target Volume (PTV) during Volumetric Modulated Arc Therapy(VMAT). Materials and Methods: In patients who received Whole Brain, Gall Bladder and Rectum radiation therapy, We compared the cover change, maximum dose, Homogenicity Index and Conformity Index of PTV and also compared the maximum dose and average dose change of Organ At Risk by organizing treatment plans that are not applied overlaped PTV and treatment plans that are applied overlaped PTV in areas where coverage is insufficient. Results: overage of treatment plans with overlapping PTVs was increased in all patients, and overall coverage was also increased in each of the four patients. The maximum dose for PTV was increased in five patients, and the Homogenicity Index and Conformity Index for all patients did not differ much. The maximum dose of the lens was increased by 1.12 times, and the maximum dose was decreased in two patients for brain stem. The mean dose of the eyeball was increased by a maximum of 1.15 times, and there was no significant difference between both parotid gland. In case of gallbladder cancer patients, the mean dose in the liver and colon was decreased, and the mean dose in the duodenum was increased. In the case of rectal cancer patients, the mean dose was reduced for both femur and bladder set as OARs. The overall MU was shown to be similar in four patients, excluding one. Conclusion: If the critical dose of OAR is considered and used properly, I think it is a useful way to improve coverage of PTV.

Effect of CT Contrast Media on Radiation Therapy Planning (Head & Neck Cancer and Prostate Cancer) (CT조영제가 방사선치료계획(두경부, 전립선)에 미치는 영향)

  • Jang, Jaeuk;Han, Manseok;Kim, Minjeong;Kang, Hyeonsoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.173-178
    • /
    • 2016
  • This study is to evaluate the effect of a Contrast Media (CM) on dose calculations and clinical significance in Radiation (Electromagnetic wave) Therapy (RT) plans for head & neck (H&N) and prostate cancer. Pinnacle 8.0 system was used to measure the change of Electron Density (ED) of the tissue for CM. To determine the effect of dose calculation due to CM, we did the RT planning for 30 patients. To compare the ED and dose calculations of RT plans, 3D CRT and IMRT plans were do with pinnacle and Tomotherapy planning system. Mean difference of ED between enhanced and unenhanced CT was less than 4%: H&N Target Volume (TV) 2.1%, parotid 1.9%, SMG 3.6%, tongue 0.9%, spinal cord 0.3%, esophagus 2.6%, mandible 0.1% and prostate TV 0.7%, lymph node 1.1%, bladder 1.2%, rectum 1.5%, small bowel 1.2%, colon 0.6%, penile bulb 0.8%, femoral head -0.2%. The dose difference between RT plan using CM and without CM showed an increase of dose in TV. The rate of increase was less than 2.5% (3D CRT: H&N 0.69~2.51%, prostate 0.04~1.14%, IMRT: H&N 0.58~1.31%, prostate 0.36~1.04%). RT plans using a CM has the insignificant effect on the organs and TV, so this error is allowable clinically. However, the much more accurate plan is possible as to image fusion (CM and without CM images) to ROI contour and when dose calculation, use the without CM image. Using the fusion of 'ROI import' perform calculations on without CM, it will be able to reduce the error (1~3%) caused by the CM.

Neurovascular Morphometric Aspect in the Region of Cranio-Cervical Junction (두개와 경추의 이행부에서 뇌신경계와 혈관계에 대한 형태학적 계측)

  • Lee, Kyu;Bae, Hack-Gun;Choi, Soon-Kwan;Yun, Seok-Mann;Doh, Jae-Won;Lee, Kyeong-Seok;Yun, Il-Gyu;Byun, Bark-Jang
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.9
    • /
    • pp.1094-1102
    • /
    • 2001
  • Objective : During the trans-condylar or trans-jugular approach for the lesion of cranio-cervical junction(CCJ), its necessary to identify the accurate locations of vertebral artery(VA), internal jugular vein(IJV) and its related lower cranial nerves. These neurovascular structures can also be damaged during the operation for vascular tumor or traumatic aneurysm around extra-jugular foramen, because of their changed locations. To reduce the neurovascular injury at the operation for CCJ, morphometric relationship of its surrounding neurovascular structures based on the tip of the transverse process of atlas(C1 TP), were studied. Materials & Methods : Using 10 adult formalin fixed cadavers, tip of mastoid process(MT) and TPs of atlas and axis were exposed bilaterally after removal of occipital and posterior neck muscles. Using standard caliper, the distances were measured from the C1 TP to the following structures : 1) exit point of VA from C1 transverse foramen, 2) branching point of muscular artery from VA, 3) entry point of VA into posterior atlanto-occipital membrane(AOM), 4) branching point of C-1 nerve. In addition, the distances were measured from the mid-portion of the posterior arch of atlas to the entry point of the VA into AOM and to the exit point of the VA from C1 transverse foramen. After removal of the ventrolateral neck muscles, neurovascular structures were exposed in the extra-jugular foraminal region. Distances were then measured from the C1 TP to the following structures : 1) just extra-jugular foraminal IJV and lower cranial nerves, 2) MT and branching point of facial nerve in parotid gland. In addition, distance between MT and branching point of facial nerve was measured. Results : The VA was located at the mean distance of 12mm(range, 10.5-14mm) from the C1 transverse foramen and entered into the AOM at the mean distance of 24mm(range, 22.8-24.4mm) from the C1 TP. The mean distance from the mid portion of the C1 posterior arch was 20.6mm(range, 19.1-22.3mm) to the entry point of the VA into AOM and 38.4mm(range, 34-42.4mm) to the exit point of the VA from C1 transverse foramen. Muscular artery branched away from the posterior aspect of the transverse portion of VA below the occipital condyle at the mean distance of 22.3mm(range, 15.3-27.5mm) from the C1 TP. The C-1 nerve was identified in all specimens and ran downward through the ventroinferior surface of the transverse segment of VA and branched at the mean distance of 20mm(range, 17.7-20.3mm) from the C1 TP. The IJV was located at the mean distance of 6.7mm(range, 1-13.4mm) ventromedially from the lateral surface of the C1 TP. The XI cranial nerve ran downward on the lateral surface of the IJV at the mean distance of 5mm(range, 3-7.5mm) from the C1 TP. Both IX and X cranial nerves were located in the soft tissue between the medial aspect of the internal carotid artery(ICA) and the medial aspect of the IJV at the mean distance of 15.3mm(range, 13-24mm) and 13.7mm(range, 11-15.4mm) from the C1 TP, respectively. The IX cranial nerve ran downward ventroinferiorly crossing the lateral aspect of the ICA. The X cranial nerve ran downward posteroinferior to the IX cranial nerve and descended posterior to the ICA. The XII cranial nerve was located between the posteroinferior aspect of the IX cranial nerve and the posterior aspect of the ICA at the mean distance of 13.3mm(range, 9-15mm) ventromedially from the C1 TP. The distance between MT and C1 TP was 17.4mm(range, 12.5-23.9mm). The VII cranial nerve branched at the mean distance of 10.2mm(range, 6.8-15.3mm) ventromedially from the MT and at the mean distance of 17.3mm(range, 13-21mm) anterosuperiorly from the C1 TP. Conclusion : This study facilitates an understanding of the microsurgical anatomy of CCJ and may help to reduce the neurovascular injury at the surgery around CCJ.

  • PDF

Reducing of Craniofacial Radiation Dose Using Automatic Exposure Control Technique in the 64 Multi-Detector Computed Tomography (64 다중 검출기 전산화단층촬영에서 관전류 자동노출조절 기법을 이용한 두개부 방사선량 감소 정도 평가)

  • Seoung, Youl-Hun;Kim, Yong-Ok;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • The purpose of this study was to evaluate the usefulness of reducing of craniofacial radiation dose using automatic exposure control (AEC) technique in the 64 multi-detector computed tomography (MDCT). We used SOMATOM Definition 64 multi-detector CT, and head of whole body phantom (KUPBU-50, Kyoto Kagaku CO. Ltd). The protocol were helical scan method with 120 kVp, 1 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of FOV, $512{\times}512$ of matrix size, $64{\times}0.625\;mm$ of collimation, and 1 of pitch. The evaluation of dose reducing effect was compared the fixed tube current of 350 with AEC technique. The image quality was measured the noise using standard deviation of CT number. The range of craniofacial bone was to mentum end from calvaria apex, which devided three regions: calvaria~superciliary ridge (1 segment), superciliary ridge~acanthion (2 segment), and acanthion~mentum (3 segment). In the fixed tube current technique, CTDIvol was 57.7 mGy, DLP was $640.2\;mGy{\cdot}cm$ in the all regions. The AEC technique was showed that 1 segment were 30.7 mGy of CTDIvol, 340.7 $mGy{\cdot}cm$ of DLP, 2 segment were 46.5 mGy of CTDIvol, $515.0\;mGy{\cdot}cm$ of DLP, and 3 segment were 30.3 mGy of CTDIvol, $337.0\;mGy{\cdot}cm$ of DLP. The standard deviation of CT number was 2.622 with the fixed tube current technique and 3.023 with the AEC technique in the 1 segment, was 3.118 with the fixed tube current technique and 3.379 with the AEC technique in the 2 segment, was 2.670 with the fixed tube current technique and 3.186 with the AEC technique in the 3 segment. The craniofacial radiation dose using AEC Technique in the 64 MDCT was evaluated the usefulness of reducing for the eye, the parotid and thyroid with high radiation sensitivity particularly.

Analysis of the major factors of influence on the conditions of the Intensity Modulated Radiation Therapy planning optimization in Head and Neck (두경부 세기견조방사선치료계획 최적화 조건에서 주요 인자들의 영향 분석)

  • Kim, Dae Sup;Lee, Woo Seok;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.11-19
    • /
    • 2014
  • Purpose : To derive the most appropriate factors by considering the effects of the major factors when applied to the optimization algorithm, thereby aiding the effective designing of a ideal treatment plan. Materials and Methods : The eclipse treatment planning system(Eclipse 10.0, Varian, USA) was used in this study. The PBC (Pencil Beam Convolution) algorithm was used for dose calculation, and the DVO (Dose Volume Optimizer 10.0.28) Optimization algorithm was used for intensity modulated radiation therapy. The experimental group consists of patients receiving intensity modulated radiation therapy for the head and neck cancer and dose prescription to two planned target volume was 2.2 Gy and 2.0 Gy simultaneously. Treatment plan was done with inverse dose calculation methods utilizing 6 MV beam and 7 fields. The optimal algorithm parameter of the established plan was selected based on volume dose-priority(Constrain), dose fluence smooth value and the impact of the treatment plan was analyzed according to the variation of each factors. Volume dose-priority determines the reference conditions and the optimization process was carried out under the condition using same ratio, but different absolute values. We evaluated the surrounding normal organs of treatment volume according to the changing conditions of the absolute values of the volume dose-priority. Dose fluence smooth value was applied by simply changing the reference conditions (absolute value) and by changing the related volume dose-priority. The treatment plan was evaluated using Conformal Index, Paddick's Conformal Index, Homogeneity Index and the average dose of each organs. Results : When the volume dose-priority values were directly proportioned by changing the absolute values, the CI values were found to be different. However PCI was $1.299{\pm}0.006$ and HI was $1.095{\pm}0.004$ while D5%/D95% was $1.090{\pm}1.011$. The impact on the prescribed dose were similar. The average dose of parotid gland decreased to 67.4, 50.3, 51.2, 47.1 Gy when the absolute values of the volume dose-priority increased by 40,60,70,90. When the dose smooth strength from each treatment plan was increased, PCI value increased to $1.338{\pm}0.006$. Conclusion : The optimization algorithm was more influenced by the ratio of each condition than the absolute value of volume dose-priority. If the same ratio was maintained, similar treatment plan was established even if the absolute values were different. Volume dose-priority of the treatment volume should be more than 50% of the normal organ volume dose-priority in order to achieve a successful treatment plan. Dose fluence smooth value should increase or decrease proportional to the volume dose-priority. Volume dose-priority is not enough to satisfy the conditions when the absolute value are applied solely.

Degradation and Conversion of Blood Group Antigens in Saliva (혈액형 항원의 분해와 변환에 관한 연구)

  • Lim, Sang-Wook;Park, Hee-Kyung;Jung, Seung-Eun;Kho, Hong-Seop;Kim, Young-Ku
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.15-23
    • /
    • 2005
  • Mucin glycoproteins are the primary carriers of the oligosaccharide moieties that constitute the blood group substances in human saliva. The aim of this study was to determine whether or not the conversion of either the A or B blood group antigens to the H antigen can occur during the degradation process of stored saliva samples. Forty subjects (20 subjects in each A and B blood group) identified as secretors were enrolled in this study. Fresh whole saliva samples and their clarified supernatants were stored at room temperature for 1 week. The conversion of the blood group antigens was detected by SDS-PAGE and immunoblotting. Among the subjects showing the conversion in whole saliva, glandular saliva samples were obtained from 8 subjects (4 subjects in each A and B blood group). Submandibular-sublingual saliva (SMSL) and a mixture of SMSL and parotid saliva (PS) were stored at room temperature for 1 week. The conversion of the blood group antigens was detected by the same method. The obtained results were as follows: 1. In the clarified samples of whole saliva, the A antigen was detected as being either intact (5%) or degraded molecules (95%) after the 1 week period. Conversion of the A antigen to the H antigen was detected in 5 subjects (25%). In the unclarified samples, the A antigen was either detected as degraded molecules (90%) or was not detected (10%). Conversion of the antigen had occurred in 4 subjects (20%). 2. In the clarified samples of whole saliva, the B antigen was detected as intact (20%) or as degraded molecules (65%) or was not detected (15%) after the 1 week period. Conversion of the B antigen to the H antigen was detected in 7 subjects (35%). In the unclarified samples, the B antigen was detected as intact (5%) or as degraded molecules (65%), or was not detected (30%). Conversion of the antigen was observed in 2 subjects (10%). 3. In the glandular saliva samples, only one of the four subjects displayed an antigenic conversion from the A to H antigen or from the B to H antigen. The conversion had occurred in both the SMSL samples and the SMSL and PS mixture. No degradation of the antigens was detected in the other three samples of the A or B blood groups, nor was there any conversion. The results demonstrated that conversion of the blood group antigens could occur in saliva, and suggested that the enzymes responsible for the conversion are present in saliva. Further studies on the origin and activity of the specific glycosidases in saliva as well as quantitative measurements of the antigenic conversion will be needed.

Preliminary Results of Phase I/II Study of Simultaneous Modulated Accelerated (SMART) for Nasopharyngeal Carcinoma (비인강암의 치료에서 동시차등조사가속치료를 적용한 제1상/2상 연구의 예비적 결과)

  • Park Jin-Hong;Back Geum-Mun;Yi Byong-Yong;Choi Eun-Kyung;Ahn Seung-Do;Shin Seong-Soo;Kim Jung-Hun;Kim Sang-Yoon;Lee Bong-Jae;Nam Soon-Yuhl;Choi Seung-Ho;Kim Seung-Bae;Lee Sang-Wook
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • Puroose: To present preliminary results of intensity-modulated radiotherapy (IMRT) using the simultaneous modulated accelerated radiation therapy (SMART) boost technique in patients with nasopharyngeal carcinoma (NPC). Materials and Methods: Twenty patients who underwent IMRT for non-metastatic NPC at the Asan Medical Center between September 2001 and December 2003 were prospectively evaluated. IMRT was delivered using the 'step and shoot' SMART technique at prescribed doses of 72 Gy (2.4 Gy/day) to the gross tumor volume (GTV), 60 Gy (2 Gy/day) to the clinical target volume (CTV) and metastatic nodal station, and 46 Gy (2 Gy/day) to the clinically negative neck region. Eighteen patients also received concurrent chemotherapy using cisplatin once per week. Results: The median follow-up period was 27 months. Nineteen patients completed the treatment without interruption; the remaining patient interrupted treatment for 2 weeks owing to severe pharyngitis and malnutrition. Five patients (25%) had RTOG grade 3 mucositis, whereas nine (45%) had grade 3 pharyngitis. Seven patients (35%) lost more than 10% of their pretreatment weight, whereas 11 (55%) required intravenous fluids and/or tube feeding. There was no grade 3 or 4 chronic xerostomia. All patients showed complete response. Two patients had distant metastases and loco-regional recurrence, respectively. Conclusion: IMRT using the SMART boost technique allows parotid sparing, as shown clinically and by dosimetry, and may also be more effective biologically. A larger population of patients and a longer follow-up period are needed to evaluate ultimate tumor control and late toxicity.