• Title/Summary/Keyword: Parameters Sensitive Analysis

Search Result 403, Processing Time 0.027 seconds

The effect of sensitive and non-sensitive parameters on DCGL in probability analysis for decommissioning of nuclear facilities

  • Hyung-Woo Seo;Hyein Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3559-3570
    • /
    • 2023
  • In the decommissioning of nuclear facilities, Derived Concentration Guideline Level (DCGL) derivation is necessary for the release of the facility after the site remediation, which also needs to be implemented in the stage of establishing a decommissioning planning. In order to derive DCGL, the dose assessment for the receptors can be conducted from residual radioactivity by using RESRAD code. When performing sensitivity analysis on probabilistic parameters, secondary evaluation is performed by assigning a single value for parameters classified as sensitive. However, several options may arise in the handling of nonsensitive parameters. Therefore, we compared the results of the first execution of RESRAD applying probabilistic parameters for each scenario with the results of the second execution applying a single value to sensitive parameters among the probabilistic parameters. In addition, we analyzed the effect of setting options for non-sensitive parameters. As a result, the effect on DCGL were different depending on the application scenario, the target radionuclides, and the input parameter selections. In terms of the overall evaluation period, the DCGL graph of the default option was generally shown as the most conservative except for some radionuclides. However, it will not necessarily be given priority in the aspect of the need to reflect site characteristics. The reason for selecting a probabilistic parameter is the availability of the parameter and the uncertainty of applying a single value. Therefore, as an alternative, it can be consistently applied to distribution as an option for non-sensitive parameters after sensitivity analysis.

SIMULATION OF DAILY RUNOFF AND SENSITIVITY ANALYSIS WITH SOIL AND WATER ASSESSMENT TOOL

  • Lee, Do-Hun;Kim, Nam-Won;Kim, In-Ho
    • Water Engineering Research
    • /
    • v.5 no.3
    • /
    • pp.133-146
    • /
    • 2004
  • Soil and water assessment tool (SWAT) was simulated based on the default parameters and a priori soil parameter estimation method in Bocheong watershed of Korea. The performance of the model was tested against the measured daily runoff data for 5 years between 1993 and 1997. The sensitivity analysis of SWAT model parameters was conducted to identify the most sensitive model parameters affecting the model output. The results of SWAT simulation indicate that the overall performance of SWAT in calculating daily runoff is reasonably acceptable. However, there is a problem in estimating the low flow components of streamflow since the low flow components simulated by SWAT are significantly different from the measured low flow. The sensitivity analysis with SWAT points out that soil related parameters are the most sensitive parameters affecting surface and ground water balance components and groundwater flow related parameters exhibit negligible sensitivity.

  • PDF

Sensitivity Analysis on Various Parameters for Lattice Analysis of DUPIC Fuel with WIMS-AECL Code

  • Gyuhong Roh;Park, Hangbok;Park, Jee-Won
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.64-69
    • /
    • 1997
  • The code WIMS-AECL has been used for the lattice analysis of DUPIC fuel. The lattice parameters calculated by the code is sensitive to the choice of number of parameters, such as the number of tracking lines, number of condensed groups, mesh spacing in the moderator region, other parameters vital to the calculation of probabilities and burnup analysis. We have studied this sensitivity with respect to these parameters and recommend their proper values which are necessary for carrying out the lattice analysis of DUPIC fuel.

  • PDF

Calibration and Sensitivity Analysis of the RICEWQ Model (RICEWQ 모형의 보정 및 민감도 분석)

  • Chung, Sang-Ok;Park, Ki-Jung;Son, Seung-Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.2
    • /
    • pp.3-10
    • /
    • 2008
  • The main objectives of this study are to calibrate the RICEWQ model with Korean field data and then analyse the sensitivity of the parameters to identify sensitive parameters. The RICEWQ is widely used to predict pesticide fate in a paddy plot. An experimental paddy plot of 0.2 ha($100{\times}20\;m$) at Seobyeon-dong, Daegu, Korea was selected, and field observations for water and pesticide balance were performed from 4 June to 2 September 2006. The molinate, which is a herbicide widely used for weed control in rice culture, was selected. The RICEWQ model was successfully calibrated both for the water and pesticide mass balance. The calibrated model showed a RMSE of 0.537 cm for ponded water depths and a RMSE of 0.036 mg/L for the molinate concentrations in the ponded water. The most sensitive parameters for molinate concentrations in ponded water were the metabolism degradation rate in water, volatilization coefficient, and release rate for slow release formulation. In contrast, the RICEWQ model was not sensitive to parameters such as hydrolysis degradation rate in water and degradation rate in unsaturated soil.

A Study on the Characteristic Analysis of the Load-sensitive Hydraulic Pump Control System (부하 감응형 유압 펌프 제어 시스템의 특성 해석에 관한 연구)

  • 이용주;이승현;송창섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.4
    • /
    • pp.148-154
    • /
    • 2000
  • In this study, the static and the dynamic characteristics of the load-sensitive hydraulic pump control systems of a hydraulic excavator were analyzed using the developed analysis tool. The results were compared with the experimental ones. To improve the static performance of the system, the system parameter effects on the controllable region and the pump pressure variation were studied. The parameters enhancing dynamic characteristics were also considered.

  • PDF

Numerical study to reproduce a real cable tray fire event in a nuclear power plant

  • Jaiho Lee ;Byeongjun Kim;Yong Hun Jung;Sangkyu Lee;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1571-1584
    • /
    • 2023
  • In this study, a numerical analysis was performed as part of an international joint research project to reproduce a real cable tray fire that occurred in the heater bay area of the turbine building of a nuclear power plant. A sensitivity analysis was performed on various input parameters to derive results consistent with the sprinkler activation time obtained from the fire event analysis. For all sensitive parameters, the normalized sprinkler activation time correlated well with the power function of the normalized sprinkler height. A correlation equation was developed to identify the sprinkler activation time at any location when determining the slope or fire growth rate under the conditions assuming a linear or t-squared heat release rate (HRR) time curve. Various cable fire growth assumptions were used to determine which assumption was better to provide the prediction coincident with the information given from the fire event analysis in terms of the sprinkler activation time and total energy generated from cables damaged by fire. In the comprehensive analysis of all the sensitive parameters, the standard deviation of the input parameters increased as the sprinkler height decreased. Within the range of the sensitivity parameter values given in this study, when considering all sprinkler heights, the standard deviation of the cable model change was the largest and that of the overhang position change was the smallest.

The Characteristic Analysis of the Load-sensitive Hydraulic Control System for Closed Center Type of a Wheel Loader (휠 로더용 폐회로형 부하 감응 유압 제어 시스템의 특성 해석)

  • Lee, Seung-Hyun;Song, Chang-Seop;Chung, Chun-Kuk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.9
    • /
    • pp.934-942
    • /
    • 2007
  • In this study, the characteristics of the load-sensitive hydraulic control system for closed center type of a wheel loader were analyzed using developed analysis program based on Amesim tool. From the parametric analysis, the effects of each factor were revealed. Through the simulation with varying parameters, the system parameter effects on the controllable region and the pump pressure and load pressure variations were studied. The results were compared with the experimental ones. The results and discussions of the present paper could aid in the design of a load-sensitive hydraulic control system for closed center type.

Sensitivity Analysis of ILLUDAS Model Parameters Based on Rainfall Conditions (강우조건이 ILLUDAS 모형 매개변수의 민감도에 미치는 영향 분석)

  • Lee, Jong Tae;Kim, Tae Hwa
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.748-757
    • /
    • 2004
  • In this study, we analyzed the sensitivity of parameters which affect the result of ILLUDAS model, in the various rainfall conditions. The three basins including Namgaja, Kings creek, Gray haven were selected for this research. The rainfall conditions are considered in terms of the rainfall frequency, the duration and the distribution. In most cases, the impermeability area ratio, the sewer slope, and the sewer roughness coefficient give more significant effects on the results than others. The results show that as increasing the rainfall frequency, the sensitivity of the parameters, sewer slope and roughness coefficient are rised, while the impermeability area ratio is decreasing. And also, for the duration of rainfall, the impermeability area ratio's sensitivity shows similar tendency. In case of the rainfall distribution, the parameters of the sewer roughness and the impermeability area ratio show more sensitive in Huff distribution. Especially, The impermeability area ratio is the most sensitive parameter in Central blocking and Yen & Chow distributions respectively.

Perfomance Analysis of SRM according to Design Parameters (SRM의 설계파라메터 변화에 따른 성능해석)

  • Kim, Tae-Hyoung;Moon, Jae-Won;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.18-20
    • /
    • 2003
  • In this paper, design and performance analysis of switched reluctance motor(SRM) according to design parameters are foaled. The parameters which are sensitive to the performance are examined and selected to have a good performances. Prototype machines are constructed to compare with the simulated results.

  • PDF

Performance Analysis of SRM according to Design Parameters (설계파라메터의 선정에 따른 SRM의 특성해석)

  • Kim, Tae-Hyoung;Moon, Jae-Won;Ahn, Jin-Woo;An, Young-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.58-61
    • /
    • 2004
  • In this paper, design and performance analysis of switched reluctance motor(SRM) according to design parameters are researched. The parameters which are sensitive to the performance are examined and selected to have good performances. Some effective guide lines to have a good performance motor are suggested. Prototype machines are constructed to compare with the simulated and tested results.

  • PDF