• Title/Summary/Keyword: Parameter study

Search Result 9,887, Processing Time 0.045 seconds

A Study on the Hydraulic Characteristics of Rashig Super-Ring Random Packing in a Counter-Current Packed Tower (역류식 충전탑에서 Raschig Super-ring Random Packing의 수력학적 특성에 대한 연구)

  • Kang, Sung Jin;Lim, Dong-Ha
    • Clean Technology
    • /
    • v.26 no.2
    • /
    • pp.102-108
    • /
    • 2020
  • In recent years, packed column has been widely used in separation processes, such as absorption, desorption, distillation, and extraction, in the petrochemical, fine chemistry, and environmental industries. Packed column is used as a contacting facility for gas-liquid and liquid-liquid systems filled with random packed materials in the column. Packed column has various advantages such as low pressure drop, economical efficiency, thermally sensitive liquids, easy repairing restoration, and noxious gas treatment. The performance of a packed column is highly dependent on the maintenance of good gas and liquid distribution throughout a packed bed; thus, this is an important consideration in a design of packed column. In this study, hydraulic pressure drop, hold-up as a function of liquid load, and mass transfer in the air, air/water, and air-NH3/water systems were studied to find the geometrical characteristic for raschig super-ring experiment dry pressure drop. Based on the results, design factors and operating conditions to handle noxious gases were obtained. The dry pressure drop of the random packing raschig super-ring was linearly increased as a function of gas capacity factor with various liquid loads in the Air/Water system. This result is lower than that of 35 mm Pall-ring, which is most commonly used in the industrial field. Also, it can be found that the hydraulic pressure drop of raschig super-ring is consistently increased by gas capacity factor with various liquid loads. When gas capacity factor with various liquid loads is increased from 1.855 to 2.323 kg-1/2 m-1/2 S-1, hydraulic pressure drop increases around 17%. Finally, the liquid hold-up related to packing volume, which is a parameter of specific liquid load depending on gas capacity factor, shows consistent increase by around 3.84 kg-1/2 m-1/2 S-1 of the gas capacity factor. However, liquid hold-up significantly increases above it.

An Analysis of Prognostic Factors in the Uterine Cervical Cancer Patients (자궁경부암 환자의 예후인자에 관한 분석)

  • Yang, Dae-Sik;Yoon, Won-Sub;Kim, Tae-Hyun;Kim, Chul-Yong;Choi, Myung-Sun
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.300-308
    • /
    • 2000
  • Purpose :The aim of this study is to analysis of suwival and recurrence rates of the uterine cervical carcinoma patients whom received the radiation therapy respectively. The prognostic factors, such as Papanicolaou (Pap) smear, carcinoembriogenic antigen (CEA) and squamous cell carcinoma (SCC) antigen has been studied. Methods and Materials : From January 1981 to December 1998, eight-hundred twenty-seven uterine carvical cancer patients were treat with radiation therapy. All of the patients were divided into two groups : the radiation therapy only (S2l patients) group and the postoperative radiation therapy (326 patients) group. The age, treatment modality, clinical stage, histopathology, recurrence, follow-up Pap smears, CEA and SCC antigen were used as parameters for the evaluation. The prognostic factors such as survival and recurrence rates were peformed with the Kaplan-Meier method and the Cox hazard model, respectively. Median rollow-up was 38.6 months. Results :On the radiation therapy only group, 314 patients (60$\%$) achieved complete response (CR), 47 patients (9$\%$) showed local recurrence (LR), 78 patients (15$\%$) developed distant metastasis (DM). On the Postoperative radiation therapy group, showed 276 Patients (85$\%$) CR, 8 Patients (2$\%$) LR, 37 Patients (11$\%$) DM. The 5-year survival and recurrence rates was evaluated for all parameters. The statistically significant factors for the survival rate in univariate analysis were clinical stage (p=0.0001), treatment modality (p=0.0010), recurrence (p=0.0001), Pap smear (p=0.0329), CEA (p=0.0001) and SCC antigen (p=0.0001). Conclusion: This study indicated that after treatment, the follow-up studies of Pap smear, CEA and SCC antigen were significant parameter and prediction factors for the survival and recurrence of the uterine cervical carcinoma.

  • PDF

Effects of Exercise Training and Selenium on MCT1 and MCT4 Protein Levels in Skeletal Muscles of Diabetic Goto-Kakizaki Rats (지구성 운동과 셀레니움 투여가 당뇨 Goto-kakizaki 쥐의 골격근의 MCT1과 MCT4단백질 발현수준에 미치는 효과)

  • Kim, Seung-Seok;Kang, Eun-Bum;Eum, Hyun-Sub;Kim, Bum-Su;Lim, Yea-Hyun;Park, Joon-Young;Cho, In-Ho;Oh, Yoo-Sung;Kwak, Yi-Sub;Cho, Joon-Yong
    • Journal of Life Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • The purpose of this study was to determine the possible additive effects of endurance exercise training (EXER) and selenium (SELE) on the improvements of glucose and lactate transport capacities in diabetic Goto-kakizaki rats. Animals either remained sedentary control (SED) or performed EXER or received SELE [$5{\mu}mol$ kg body wt (-1) day (-1)], or underwent both EXER and SELE (COMBI), which lasted for 6 wk. Compared with sedentary control, EXER alone or the SELE alone group, or the combined treatment group had significant reduction in glucose response measured at 90 min and 120 min during an intraperitoneal glucose tolerance test (IPGTT) and body weight after 6week treatment. EXER alone, or combined group individually had significantly higher glycogen contents in liver compared with SED or SELE groups. EXER alone increased glycogen content in soleus and plantaris compared with SED, and this parameter was increased to greatest extent in the combined treatment groups compared with SED or SELE groups. EXER alone, SELE alone or COMBI, caused significant decreases in the plasma lactates, serum glucose, insulin, total cholesterol and HOMA-IR along with a significant increase in high-density lipoprotein cholesterol compared with SED. In addition, EXER or COMBI individually had significantly lower serum triacylglycerol compared with SED or SELE. With respect to protein expression related to glucose and lactate transport capacities, EXER alone, SELE alone, or COMBI increased in MCT1 and MCT4 protein level in soleus and plantaris. Furthermore, EXER alone, SELE alone or COMBI caused significant increases in mt MCT1 protein level in soleus and plantaris. The findings of the current study suggest that endurance exercise training and selenium treatment may provide therapeutic values to type II diabetic patients with peripheral insulin resistance and hyperlactatecemia by improving glucose and lactate transport capacities, leading to improvements in plasma lactate, serum glucose, insulin and lipid profiles (TC, TG, HDL).

The cephalometric study of skeletal types in Cl III malocclusion with reduced lower anterior face height (전하안면 고경이 작은 III급 부정교합자의 골격유형에 관한 두부방사선 계측학적 연구)

  • Han, Dong-Hun;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.26 no.2 s.55
    • /
    • pp.205-218
    • /
    • 1996
  • A given facial type can be considered as a syndrome in which various features are aggregated, so a single parameter is not sufficient to accurately identify a given facial type. This study was designed to identify & characterize the skeletal types that blend under the headline-'Cl III,deepbite'. Cephalograms of thirty-four untreated mixed dentition patients, selected mainly on the basis of clinical impression of Cl III with reduced lower face heights were studied. The following conclusion can be drawn. 1. Cl III malocclusion with reduced lower face height could be classified into three types. 2. Subtype 1 was identified by the following features : strong ramus, more anteriorly positioned upper molars without alveolar hypoplasia, acutely reduced Mn. plane angle. 3. Subtype 2 was characterized by a short ramus, sharply reduced postrior alveolar height, and normal Mn. plane angle. In general, this type had hypoplasia tendency in the vertical dimension. 4. In subtype 3, the AUFH occupying more percentage than ALFH was a outstanding feature. Ramal height was in normal range, alveolar hypoplasia and slightly reduced Mn. plane angle was observed. 5. The features of the subtypes were reflected in certain indices, which can be regarded as discriminative index. LAFH: if reduced, regardless of subtypes, indicates reduced lower ant. face height consistently. FHR: when this ratio is increased, it indicates subtype 1. FHI: when this ratio is in normal range, it indicates subtype 2. FPI: if reduced greatly, it indicates subtype 3.

  • PDF

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF

Evaluation of Setup Uncertainty on the CTV Dose and Setup Margin Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 셋업오차가 임상표적체적에 전달되는 선량과 셋업마진에 대하여 미치는 영향 평가)

  • Cho, Il-Sung;Kwark, Jung-Won;Cho, Byung-Chul;Kim, Jong-Hoon;Ahn, Seung-Do;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.81-90
    • /
    • 2012
  • The effect of setup uncertainties on CTV dose and the correlation between setup uncertainties and setup margin were evaluated by Monte Carlo based numerical simulation. Patient specific information of IMRT treatment plan for rectal cancer designed on the VARIAN Eclipse planning system was utilized for the Monte Carlo simulation program including the planned dose distribution and tumor volume information of a rectal cancer patient. The simulation program was developed for the purpose of the study on Linux environment using open source packages, GNU C++ and ROOT data analysis framework. All misalignments of patient setup were assumed to follow the central limit theorem. Thus systematic and random errors were generated according to the gaussian statistics with a given standard deviation as simulation input parameter. After the setup error simulations, the change of dose in CTV volume was analyzed with the simulation result. In order to verify the conventional margin recipe, the correlation between setup error and setup margin was compared with the margin formula developed on three dimensional conformal radiation therapy. The simulation was performed total 2,000 times for each simulation input of systematic and random errors independently. The size of standard deviation for generating patient setup errors was changed from 1 mm to 10 mm with 1 mm step. In case for the systematic error the minimum dose on CTV $D_{min}^{stat{\cdot}}$ was decreased from 100.4 to 72.50% and the mean dose $\bar{D}_{syst{\cdot}}$ was decreased from 100.45% to 97.88%. However the standard deviation of dose distribution in CTV volume was increased from 0.02% to 3.33%. The effect of random error gave the same result of a reduction of mean and minimum dose to CTV volume. It was found that the minimum dose on CTV volume $D_{min}^{rand{\cdot}}$ was reduced from 100.45% to 94.80% and the mean dose to CTV $\bar{D}_{rand{\cdot}}$ was decreased from 100.46% to 97.87%. Like systematic error, the standard deviation of CTV dose ${\Delta}D_{rand}$ was increased from 0.01% to 0.63%. After calculating a size of margin for each systematic and random error the "population ratio" was introduced and applied to verify margin recipe. It was found that the conventional margin formula satisfy margin object on IMRT treatment for rectal cancer. It is considered that the developed Monte-carlo based simulation program might be useful to study for patient setup error and dose coverage in CTV volume due to variations of margin size and setup error.

Comparative Evaluation on Sperm Parameter of Transgenic Pigs with General Pigs (형질전환 돼지의 정자와 일반돼지의 정자성상에 대한 비교평가)

  • Park, Sang Hyoun;Lee, Gunsup;Lee, Joo Yung;Kim, Kyung Woon;Byun, Sung-June;Ock, Sun A;Hwang, Seongsoo;Yang, Hyeon;Woo, Jae-Seok;Oh, Keon Bong
    • Journal of Embryo Transfer
    • /
    • v.32 no.3
    • /
    • pp.227-233
    • /
    • 2017
  • Pig has been known to be one of the most feasible animals as a bioreactor to produce pharmaceuticals in milk and as a mediator in xenotransplantation research. Previously, we generated transgenic pigs for both purposes, which were expressing Factor 8, vWF, hTPA, and hEPO in milk, along with expression of MCP at GalT gene locus ($GalT^{-MCP/-MCP}$) as well as expressing MCP at GalT gene loci with CD73 expression ($GalT^{-MCP/+}/CD73$). In this study, we performed comparative analyses of sperm parameters between wild type male (WT) pig and those transgenic males to examine the effects of transgenes integrated into the pigs on motility, morphology, viability, and acrosome integrity of the spermatozoa. Our results showed that the rates of actively motile spermatozoa of WT, Factor 8, vWF, hTPA, hEPO, $GalT^{-MCP/+}/CD73$, and $GalT^{-MCP/-MCP}$ pigs were 85.0%, 83.3%, 82.5%, 83.3%, 82.5%, 77.5%, and 78.7%, respectively. Whereas, the rates of morphologically normal spermatozoa of WT, Factor 8, vWF, hTPA, hEPO, $GalT^{-MCP/+}/CD73$, and $GalT^{-MCP/-MCP}$ pigs were 90.0%, 80.0%, 80.0%, 83.3%, 85.0%, 91.8%, and 80.8%, respectively. In addition, the viability in spermatozoa of WT, Factor 8, vWF, hTPA, hEPO, $GalT^{-MCP/+}/CD73$, and $GalT^{-MCP/-MCP}$ pigs were 93.9%, 82.4%, 89.9%, 83.9%, 87.4%, 92.8%, and 83.6%, respectively. The rates of spermatozoa with normal acrosome integrity in WT, Factor 8, vWF, hTPA, hEPO, $GalT^{-MCP/+}/CD73$, and $GalT^{-MCP/-MCP}$ pigs were 98.1%, 98.6%, 98.6%, 98.7%, 98.1%, 99.5%, and 95.1%, respectively. There were no significant differences in motility, morphology, viability, and acrosome integrity of the spermatozoa among WT, Factor 8, vWF, hTPA, and hEPO, $GalT^{-MCP/+}/CD73$, and $GalT^{-MCP/-MCP}$ pigs. These mean that neither random integration nor targeted integration of the transgene into chromosome of pig effect on characteristics of spermatozoa. Ultimately, the transgenic male pigs subjected in this study could apply to propagate their progenies for production of human therapeutic proteins and advancing the xenotransplantation research.

Evaluation of Thermal Catalytic Decomposition of Chlorinated Hydrocarbons and Catalyst-Poison Effect by Sulfur Compound (염소계 탄화수소의 열촉매 분해와 황화합물에 의한 촉매독 영향 평가)

  • Jo, Wan-Kuen;Shin, Seung-Ho;Yang, Chang-Hee;Kim, Mo-Geun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.577-583
    • /
    • 2007
  • To overcome certain disadvantages of past typical control techniques for toxic contaminants emitted from various industrial processes, the current study was conducted to establish a thermal catalytic system using mesh-type transition-metal platinum(Pt)/stainless steel(SS) catalyst and to evaluate catalytic thermal destruction of five chlorinated hydrocarbons[chlorobenzene(CHB), chloroform(CHF), perchloroethylene (PCE), 1,1,1-trichloroethane(TCEthane), trichloroethylene(TCE)]. In addition, this study evaluated the catalyst poison effect on the catalytic thermal destruction. Three operating parameters tested for the thermal catalyst system included the inlet concentrations, the incineration temperature, and the residence time in the catalyst system. The thermal decomposition efficiency decreased from the highest value of 100% to the lowest value of almost 0%(CHB) as the input concentration increased, depending upon the type of chlorinated compounds. The destruction efficiencies of the four target compounds, except for TCEthane, increased upto almost 100% as the reaction temperature increased, whereas the destruction efficiency for TCEthane did not significantly vary. For the target compounds except for TCEthane, the catalytic destruction efficiencies increased up to 30% to 97% as the residence time increased from 10 sec to 60 sec, but the increase of destruction efficiency for TCEthane stopped at the residence time of 30 sec, suggesting that long residence times are not always proper for thermal destruction of VOCs, when considering the destruction efficiency and operation costs of thermal catalytic system together. Conclusively, the current findings suggest that when applying the transition-metal catalyst for the better destruction of chlorinated hydrocarbons, VOC type should be considered, along with their inlet concentrations, and reaction temperature and residence time in catalytic system. Meanwhile, the addition of high methyl sulfide(1.8 ppm) caused a drop of 0 to 50% in the removal efficiencies of the target compounds, whereas the addition of low methyl sulfide (0.1 ppm), which is lower than the concentrations of sulfur compounds measured in typical industrial emissions, did not cause.

Predictive Clustering-based Collaborative Filtering Technique for Performance-Stability of Recommendation System (추천 시스템의 성능 안정성을 위한 예측적 군집화 기반 협업 필터링 기법)

  • Lee, O-Joun;You, Eun-Soon
    • Journal of Intelligence and Information Systems
    • /
    • v.21 no.1
    • /
    • pp.119-142
    • /
    • 2015
  • With the explosive growth in the volume of information, Internet users are experiencing considerable difficulties in obtaining necessary information online. Against this backdrop, ever-greater importance is being placed on a recommender system that provides information catered to user preferences and tastes in an attempt to address issues associated with information overload. To this end, a number of techniques have been proposed, including content-based filtering (CBF), demographic filtering (DF) and collaborative filtering (CF). Among them, CBF and DF require external information and thus cannot be applied to a variety of domains. CF, on the other hand, is widely used since it is relatively free from the domain constraint. The CF technique is broadly classified into memory-based CF, model-based CF and hybrid CF. Model-based CF addresses the drawbacks of CF by considering the Bayesian model, clustering model or dependency network model. This filtering technique not only improves the sparsity and scalability issues but also boosts predictive performance. However, it involves expensive model-building and results in a tradeoff between performance and scalability. Such tradeoff is attributed to reduced coverage, which is a type of sparsity issues. In addition, expensive model-building may lead to performance instability since changes in the domain environment cannot be immediately incorporated into the model due to high costs involved. Cumulative changes in the domain environment that have failed to be reflected eventually undermine system performance. This study incorporates the Markov model of transition probabilities and the concept of fuzzy clustering with CBCF to propose predictive clustering-based CF (PCCF) that solves the issues of reduced coverage and of unstable performance. The method improves performance instability by tracking the changes in user preferences and bridging the gap between the static model and dynamic users. Furthermore, the issue of reduced coverage also improves by expanding the coverage based on transition probabilities and clustering probabilities. The proposed method consists of four processes. First, user preferences are normalized in preference clustering. Second, changes in user preferences are detected from review score entries during preference transition detection. Third, user propensities are normalized using patterns of changes (propensities) in user preferences in propensity clustering. Lastly, the preference prediction model is developed to predict user preferences for items during preference prediction. The proposed method has been validated by testing the robustness of performance instability and scalability-performance tradeoff. The initial test compared and analyzed the performance of individual recommender systems each enabled by IBCF, CBCF, ICFEC and PCCF under an environment where data sparsity had been minimized. The following test adjusted the optimal number of clusters in CBCF, ICFEC and PCCF for a comparative analysis of subsequent changes in the system performance. The test results revealed that the suggested method produced insignificant improvement in performance in comparison with the existing techniques. In addition, it failed to achieve significant improvement in the standard deviation that indicates the degree of data fluctuation. Notwithstanding, it resulted in marked improvement over the existing techniques in terms of range that indicates the level of performance fluctuation. The level of performance fluctuation before and after the model generation improved by 51.31% in the initial test. Then in the following test, there has been 36.05% improvement in the level of performance fluctuation driven by the changes in the number of clusters. This signifies that the proposed method, despite the slight performance improvement, clearly offers better performance stability compared to the existing techniques. Further research on this study will be directed toward enhancing the recommendation performance that failed to demonstrate significant improvement over the existing techniques. The future research will consider the introduction of a high-dimensional parameter-free clustering algorithm or deep learning-based model in order to improve performance in recommendations.

The Study on the Factors for Detection of Renal Stone on Ultrasound (초음파 검사에서 신장 결석의 검출 요인에 관한 연구)

  • Sim, Hyun-Sun;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • Purpose: Renal stones are common and typically arise within the collecting system. The renal sinus are contains the collection system, the renal vessels, lymphatcs, fat, and fibrous tissue. Because of the compression of all the large echoes in signal processing, the echo from the renal stone generally cannot be distinguished from large echoes emanating from normal structures of the renal sinus. Use of ultrasonography has been difficult for detecting small renal stone without posterior shadowing and chemical composition of stone. The aim of study was measuring for posterior acoustic shadowing to a stone for various scan parameter and it examines a help in renal stone diagnosis. Material & Methods: The stone was place on sponge examined in a water bath with a 3.5MHz or 7.5MHz transducer(LOGIQ 400, USA). First, tested a variety of gain. Second, tested a variety of dynamic range. Third, tested a variety of focal zone. Fourth, measuring of the echo level for low and high frequency for depth. Results: 1) Average echo level was 98 for low total gain(10 dB) and was 142 for high total gain(40 dB). Posterior acoustic shadowing of renal stone was clear for low gain. 2) Average echo level was 129 for low dynamic range(42 dB) and was 101 for high dynamic range(72 dB). Posterior acoustic shadowing of renal stone was clear for high dynamic range. 3) When stone is in focal zone of transducer, definite posterior acoustic shadow is identified. 4) Stone was clear appeared for high frequency(7.5 MHz) than low frequency(3.5 MHz) and it is not distorted. Conclusion: The demonstration of an posterior acoustic shadow of renal stone dependents on several technical factors such as gain, dynamic range, focus, and frequency. This various factors are a help in renal stone diagnosis.

  • PDF