• Title/Summary/Keyword: Parameter Efficiency

Search Result 1,355, Processing Time 0.027 seconds

Ozone Sensitivity of Physiological Indicators for Stress Evaluation in Four Families of Quercus aliena Blume (갈참나무 4가계에서 스트레스 평가용 생리 지표들의 오존 민감성)

  • Kim, Du-Hyun;Han, Sim-Hee;Lee, Jae-Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.6
    • /
    • pp.878-884
    • /
    • 2010
  • Ozone sensitivity of physiological indicators and the difference of ozone tolerance on 4 families of Quercus aliena seedlings were investigated on the basis of the standardized physiological indicators. Photosynthetic parameters, photosynthetic pigment and malondialdehyde (MDA) content, and antioxidative enzyme activities were measured or analyzed from the leaves of Q. aliena seedlings at the end of ozone fumigation, and ozone tolerance indices among 4 families were calculated with the standardized physiological parameters. After ozone treatment, the reduction of carboxylation efficiency was observed in the leaves of four families, and their reduction were ranged from -24.1% to -56.9% of control seedlings. Photosynthetic pigment content differed significantly among 4 families and treatments. The reduction of total chlorophyll content showed the highest in family SU4 (-40.6%) and the lowest family US2 (-18.8%). Ascorbate-peroxidase (APX) activity showed significant difference among families and treatments, and increased as compared with control in three families, except for family US2. On the basis of the physiological indices, ozone tolerance of four families was ranked in the order of US1 > SU4 > US2 > SU1. In conclusion, photosynthetic parameters, pigment content and APX activity were recommended as appropriate indicators to assess the tolerance against ozone stress of Q. aliena.

The Effect of Plant Coverage on the Constructed Wetlands Performance and Development and Management of Macrophyte Communities (식생피도가 인공습지의 질소 및 인 처리효율에 미치는 영향과 습지식물의 조성 및 관리)

  • Ham, Jong-Hwa;Kim, Hyung-Chul;Koo, Won-Seok;Shin, Hyun-Bhum;Yun, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.3 s.113
    • /
    • pp.393-402
    • /
    • 2005
  • The field scale experiment was performed to examine the effect of plant coverage on the constructed wetland performance and recommend the optimum development and management of macrophyte communities. Four sets (each set of 0.88 ha) of wetland (0.8 ha) and pond (0.08 ha) systems were used. Water flowing into the Seokmoon estuarine reservoir from the Dangjin stream was pumped into wetland system. Water depth was maintained at 0.3 ${\sim}$ 0.5 m and hydraulic retention time was managed to about 2 ${\sim}$ 5 days; emergent plants were allowed to grow in the wetlands. After three growing seasons of the construction of wetlands, plant coverage was about 90%, even with no plantation, from bare soil surfaces at the initial stage. During the start up period of constructed wetlands, lower water levels should be maintained to avoid flooding newly plants, if wetland plants are to be started from germinating seeds. Effluent T-N concentration in low plant coverage wetland was higher in winter than high plant coverage wetland, whereas no T-P effluent concentration and removal efficiency difference was observed within 15% plant coverage. Dead vegetation affected nitrogen removal during winter because it is a source of organic carbon which is an essential parameter in denitrification. Biomass harvesting is not a realistic management option for most constructed wetland systems because it could only slightly increase the removal rate and provide a minor nitrogen removal pathway due to lack of organic carbon.

Dynamic-Response-Free SMPS Using a New High-Resolution DPWM Generator Based on Switched-Capacitor Delay Technique (Switched-Capacitor 지연 기법의 새로운 고해상도 DPWM 발생기를 이용한 Dynamic-Response-Free SMPS)

  • Lim, Ji-Hoon;Park, Young-Kyun;Wee, Jae-Kyung;Song, In-Chae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.1
    • /
    • pp.15-24
    • /
    • 2012
  • In this paper, we suggest the dynamic-response-free SMPS using a new high-resolution DPWM generator based on switched-capacitor delay technique. In the proposed system, duty ratio of DPWM is controlled by voltage slope of an internal capacitor using switched-capacitor delay technique. In the proposed circuit, it is possible to track output voltage by controlling current of the internal capacitor of the DPWM generator through comparison between the feedback voltage and the reference voltage. Therefore the proposed circuit is not restricted by the dynamic-response characteristic which is a problem in the existing SMPS using the closed-loop control method. In addition, it has great advantage that ringing phenomenon due to overshoot/undershoot does not appear on output voltage. The proposed circuit can operate at switching frequencies of 1MHz~10MHz using internal operating frequency of 100 MHz. The maximum current of the core circuit is 2.7 mA and the total current of the entire circuit including output buffer is 15 mA at the switching frequency of 10 MHz. The proposed circuit has DPWM duty ratio resolution of 0.125 %. It can accommodate load current up to 1 A. The maximum ripple of output voltage is 8 mV. To verify operation of the proposed circuit, we carried out simulation with Dongbu Hitek BCD $0.35{\mu}m$ technology parameter.

Effect of plant growth regulators on soybean and red bean seedling growth

  • Lee, Won Hee;Ryu, Hee La;Jeong, Eun Ju;Lee, In Jung
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.204-204
    • /
    • 2017
  • In recent years the growth rates of world agricultural production and crop yields have slowed because of rapid urbanization but the agriculture mechanization implies the use of various power sources and improved farm tools and equipment to enhance the efficiency of utilization of various crop input. Therefore the current study was conducted to investigate the growth characteristics of seedlings treated with plant growth regulators for the production of seeds suitable for mechanical formulations of soybeans and red beans. The seeds of Uram bean and Arary red bean were sown in 128 well plug tray as the testing varieties. Three growth inhibitors such as 0.05% hexaconazole, prohexadion-calcium, and 0.1% diniconazole were treated and fifteen representative plants were collected from each treatment at 2, 5, 7, 13, 16, 17, 19, and 20 days interval after treatment. The collected plants were examined for the growth atributes such as plant height, root length, leaf area and chlorophyll. The growth promoter was treated at the 13th day after treatment with growth inhibitor and treated with 0.1% concentration of Pomina ($GA_{4+7}$ 1.8% + 6-benzylaminopurine 1.8%) and Nonaji (gibberellic acid 2% + $GA_{4+7}$ 2%). Initially the growth data was recorded to examine the effect of growth inhibitor, while after treatment with growth promoters, the growth attributes were recorded at 4th and 7th day. As a result of measuring the growth parameter of soybean, the inhibitory effect was shown in the aerobic treatment at the ground level at the 7th day after treatment. At the 4th day of growth promoting agents treatment, the stimulation effect of non - treated plants was greater than that of formalin treatments. As a result of measuring the growth attributes of red bean, In the latter part of the growth, at the 4th day after the growth promoter treatment. This study was able to confirm the effective growth regulators and treatment periods for each crop, and it was possible to control the growth of seedlings. Based on these results, it can be expected that the basis of seedling production technology of crops which is necessary for sowing and transplantation mechanization of agriculturle field can be established.

  • PDF

The Usefulness of Initial Arterial Base Deficit in Trauma Patients (내원 초기에 측정한 외상환자의 동맥혈 염기결핍의 유용성)

  • Lee, Eun Hun;Choi, Jae Young;Choi, Young Cheol;Hwang, Seong Youn
    • Journal of Trauma and Injury
    • /
    • v.19 no.1
    • /
    • pp.67-73
    • /
    • 2006
  • Purpose: The arterial base deficit (BD) has proven to be useful in the evaluation and management of trauma patients. Indicators such as the Triage-Revised Trauma Score (t-RTS) and the systemic inflammatory response syndrome (SIRS) score have been used as triage tools for emergency trauma patients in Korea. The purpose of this study was to assess the usefulness of the initial BD in predicting injury severity and outcome in the trauma population. Methods: The medical records of 308 consecutive trauma patients admitted to the Emergency Center of Masan Samsung Hospital from January 2004 to December 2004 were carefully examined prospectively and retrospectively, and 291 patients were selected as subjects for this research. The SIRS score and the t-RTS were calculated based on the records from the emergency department, and the BD was calculated based on the arterial blood gas analysis obtained within 30 minutes of admission. The efficiency of the three indicators as triage tools was evaluated by using cross tabulations in two - by - two matrices and by using a receiver operating characteristic (ROC) curve analysis. Results: When the mortality was used as the outcome parameter, the sensitivity and the accuracy of the initial BD were higher than those of the SIRS score (p<0.05) and were same as those of the t-RTS. The areas under the ROC curves of the initial BD, the SIRS score, and the t-RTS were $0.740{\pm}0.087$, $0.696{\pm}0.082$, and $0.871{\pm}0.072$, respectively (95% confidence interval). When emergency operation and blood transfusion requirements were used as outcome parameters, the comparisons of the sensitivities and the accuracies of the initial BD and the other two indicators showed the same pattern as mentioned above. The areas under the ROC curves of the initial BD were 0.7~0.8 and were larger than those of the SIRS score (p<0.05). Conclusion: The ability of the initial BD to predict injury severity and outcome was similar to those of the t-RTS and the SIRS score. Therefore, the authors suggest that the initial BD may be used as an alternative to previous triage tools for trauma patients.

Quenching Curves for VOCs in the Analysis of Groundwater $^{14}C$ using Liquid Scintillation Counter (액체섬광계수기를 이용한 지하수의 $^{14}C$ 측정에서 휘발성유기화합물(VOC)에 대한 소광곡선)

  • Lee, Kil-Yong;Cho, Soo-Young;Yoon, Yoon-Yeol;Ko, Kyung-Seok;Kim, Yong-Je
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.53-59
    • /
    • 2007
  • Optimal quenching curves have been studied for the accurate analysis of $^{14}C$ in groundwater polluted by reducing efficiency of volatile organic compounds (VOCs) in liquid scintillation counter (LSC). The quenching parameters (SQP(E)) were measured for ten VOCs such as benzene, toluene, ethylbenzene, o-(m-,p-)xylene, trichloroethylene (TCE), tetrachloroethylene(PCE), carbon tetrachloride and chloroform. The quenching curves were plotted using $^{14}C$ standard solution and chloroform as a quenching agent. Optimal plotting conditions were determined for standard solution, LSC measuring time and the concentration of chloroform. The quenching effects of chlorinated organic compounds such as TCE, PCE, carbon tetrachloride and chloroform were greater than those of BTEX (benzene, toluene, ethylbenzene and xylene). Optimum measuring time was 100 minutes far 7,000 dpm/mL standard solution. A few mL of chloroform should be added for good quenching curves. These quenching curves have good correlation coefficients (> 0.99) and the curves could be applied to accurate analysis of $^{14}C$ in groundwater and tap water.

Genetic parameters of milk β-hydroxybutyrate acid, milk acetone, milk yield, and energy-corrected milk for Holstein dairy cattle in Korea (국내 Holstein종에서 milk β-hydroxybutyrate acid, milk acetone, 에너지 보정유량 및 산유량의 유전모수 추정)

  • Lee, SeokHyun;Choi, Sungwoon;Dang, Chang-Gwon;Mahboob, Alarn;Do, ChangHee
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.6
    • /
    • pp.1349-1360
    • /
    • 2017
  • This study was conducted to estimate the genetic parameters for common ketosis indicators (${\beta}$-hydroxybutyrate acid, BHBA; milk acetone), feed intake efficiency indicator (energy-corrected milk, ECM), and milk yield (MY) in Korean Holstein. A total of 75,072 monthly test-day records from 14,397 first parity cows were collected, between 2012 and 2016, from Korea animal improvement association enrolled farms. Variance components were estimated using a multiple trait random regression model. The heritability of BHBA and acetone levels ranged from 0.06 to 0.15 at different DIMs. The phenotypic and genetic correlations between BHBA and acetone were between 0.73 and 0.90, and between 0.93 and 0.98, respectively. The phenotypic correlation between BHBA and MY, between acetone and MY, between BHBA and ECM, and between acetone and ECM ranged from -0.18 to -0.05, -0.23 to -0.05, 0 to 0.10, and -0.09 to 0.01, respectively. Genetic correlation estimates between BHBA and MY, between acetone and MY, between BHBA and ECM, and between acetone and ECM also ranged from -0.55 to 0.05, -0.62 to -0.04, -0.10 to 0.11, and -0.20 to 0.00, respectively. We hope that these results would greatly assist in the improvement of ketosis disease in the local Holsteins.

Food Waste Composting by Soil Microbial Inoculators (토양미생물제제에 의한 음식물폐기물의 퇴비화 검토)

  • Bae, Il-sang;Jung, Kweon;Jeon, Eun-Mi;Kim, Gwang-Jin;Lee, Dong-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.4
    • /
    • pp.160-167
    • /
    • 2000
  • This study was performed to evaluate efficiency of soil microbial inoculator for active composting of food waste. In addition the number of microorganisms in roil microbial inoculator and the effect of seeding in the process of composting were investigated. food waste samples collected from a refectory were analyzed for physical-chemical properties. The samples were adjusted to moisture content of 65% by saw dust and seeded with soil microbial inoculator of 10% by the weight in case of reactor B. The number of microorganisms, aerobic bacteria, actinomyces, yeast, and fungi in soil microbial inoculator were over $2.98{\times}10^9/g$, $3.93{\times}10^7/g$, $1.21{\times} 10^5/g$, and $5.79{\times}10^7/g$, respectively. During the process of composting, the highest temperatures were $63.4^{\circ}C$ at reactor A(unseeded control)after 10 days and $66.8^{\circ}C$ at reactor B(seeded compost) after 4 days. The pH values of reactor A and B rapidly increased after 3 days and after first few days during composting period, respectively. The highest $CO_2$ concentrations were 6.1%(after 10 days) and 10.8%(afer 4 days) in reactor A and B, respectively. The degradation rates of organic matter(rd) between reactor A and B increased by 17.1% and 64.5%, respectively Consequently, the effects of Inoculation on comporting parameter such as temperature increasing, pH change, chemical properties, and the degradation rates of organic matter(rd) were higher in seeded compost than in unseeded control.

  • PDF

An Analysis on the Bleeding Effect of SCW Ground Heat Exchanger using Thermal Response Test Data (열응답시험 데이터를 이용한 SCW형 지중열교환기 블리딩 효과 분석)

  • Chang, Keun-Sun;Kim, Min-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.512-520
    • /
    • 2020
  • Recently, the applications of the standing column well (SCW) ground heat exchanger (GHX) have increased significantly in Korea as a heat transfer mechanism of ground source heat pump systems (GSHP) because of its high heat capacity and efficiency. Among the various design and operating parameters, bleeding was found to be the most important parameter for improving the thermal performance, such as ground thermal conductivity and borehole thermal resistance. In this study, a bleeding analysis model was developed using the thermal response test data, and the effects of bleeding rates and bleeding locations on the thermal performance of anSCW were investigated. The results show that, when the ground water flows into the top of anSCW, the time variation of circulating water temperature decreased with increasing bleeding rate, and the ground thermal conductivity increases by as much as 179% with a 30% bleeding rate. When the ground water flows into the bottom of the SCW, the circulating water temperatures become almost constant after the increase in the beginning time because the circulating water exchanges heat with the ground structure before mixing with the ground water at the bottom.

Design of a synchronization controller for non-rail mobile rack using repetitive control method (반복제어기법을 이용한 무궤도 이동랙 동기화제어기 설계)

  • Kim, Hwan-Seong;Park, Jin;Ha, Yun-Su
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.527-534
    • /
    • 2016
  • The non-rail mobile rack, which is used for cargo storage, can improve the storage capacities of logistics centers. Furthermore, it has the advantage that it can be used in traditional logistics centers without making any changes or renovation, such as installing rails. However, when the rack is operated by separated drive actuators mounted on the left and the right wheels, precise position control of the wheels is necessary even if the unbalanced cargo weight on the rack would affect the control. Therefore, internal synchronization control for position tracking between the left and right wheels on the non-rail mobile rack is necessary in this study. In addition, external synchronization control for realizing the same straight movements between mobile racks is necessary. For the internal and the external synchronization control, we propose a synchronization control algorithm based on the repetitive control theory. An internal synchronization control algorithm with repetitive control theory requires the application of the robust servo control method owing to parameter variations. In this case, we can set up the gains for the robust servo control system by considering the cargo variations on the mobile rack. Furthermore, for developing the external synchronization control algorithm, we use a double repetitive control system to perform synchronization control between mobile racks. The efficiency of the proposed control algorithm will be verified by simulation and experimental results. The proposed algorithm can be easily applied in the industry.