• 제목/요약/키워드: Parallel-connected inverter

검색결과 88건 처리시간 0.025초

2MW 풍력발전기용 병렬형 Inverter 개발 (Parallel Inverter Development for 2MW Windpower)

  • 이현영;강신일;권오정;최효진;권세진;손윤규;서재학;장성덕;오종석;이병철;황진수;류지윤
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.336-340
    • /
    • 2007
  • 본 논문에서는 750kW 풍력발전용 인버터를 개발한 결과와 2년 동안의 현장실증을 통하여 얻어진 경험을 바탕으로 2MW 영구자석형 동기발전기(RMSG, Permanent Magnet Synchronous Generator)의 전력변환을 위한 병렬형 인버터의 시뮬레이션과 이를 통한 설계와 제작 및 기본시험 과정을 소개하고자 한다.

  • PDF

다중공진 영전류 스위칭을 이용한 고주파 유도가열용 인버터 (High Frequency Inverter for Induction Heating with Multi-Resonant Zero Current Switching)

  • 라병훈;서기영;이현우;김광태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.38-40
    • /
    • 2002
  • In the case of conventional high frequency inverter, with damage of switch by surge voltage when switch gets into compulsion extinction by load accident and so on because reactor is connected by series to switch, or there was problem of conduction loss by reactor's resistivity component, Also, it has controversial point of that can not ignore conduction loss of switch in complete work kind action of soft switching. In this paper, as high frequency induction heating power supply, we propose half bridge type multi resonance soft switching high frequency inverter topology that can realize high amplitude operation of load current with controlling switch current by multiplex resonance, mitigating surge voltage when switch gets into compulsion extinction and to be complete operation of zero current switching by opposit parallel connected reactor to inverter switch. and do circuit analysis for choice of most suitable circuit parameter of circuit

  • PDF

Soft-Switching T-Type Multilevel Inverter

  • Chen, Tianyu;Narimani, Mehdi
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1182-1192
    • /
    • 2019
  • In order to improve the conversion efficiency and mitigate the EMI problem of conventional hard-switching inverters, a new soft-switching DC-AC inverter with a compact structure and a low modulation complexity is proposed in this paper. In the proposed structure, resonant inductors are connected in series for the arm branches, and resonant capacitors are connected in parallel for the neutral point branches. With the help of resonant components, the proposed structure achieves zero-current switching on the arm branches and zero-voltage switching on the neutral point branches. When compared with state-of-art soft-switching topologies, the proposed topology does not need auxiliary switches. Moreover, the commutation algorithm to realize soft-switching can be easily implemented. In this paper, the principle of the resonant operation of the proposed soft-switching converter is presented and its performance is verified through simulation studies. The feasibility of the proposed inverter is evaluated experimentally with a 2.4-kW prototype.

Common-mode Voltage Reduction for Inverters Connected in Parallel Using an MPC Method with Subdivided Voltage Vectors

  • Park, Joon Young;Sin, Jiook;Bak, Yeongsu;Park, Sung-Min;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1212-1222
    • /
    • 2018
  • This paper presents a model predictive control (MPC) method to reduce the common-mode voltage (CMV) for inverters connected in parallel, which increase the capacity of energy storage systems (ESSs). The proposed method is based on subdivided voltage vectors, and the resulting algorithm can be applied to control the inverters. Furthermore, we use more voltage vectors than the conventional MPC algorithm; consequently, the quality of grid currents is improved. Several methods were proposed in order to reduce the CMV appearing during operation and its adverse effects. However, those methods have shown to increase the total harmonic distortion of the grid currents. Our method, however, aims to both avoid this drawback and effectively reduce the CMV. By employing phase difference in the carrier signals to control each inverter, we successfully reduced the CMV for inverters connected in parallel, thus outperforming similar methods. In fact, the validity of the proposed method was verified by simulations and experimental results.

Study on Motor Characteristics due to Deviation of the Wheel Diameters with Parallel Operation

  • Lee, Hyung-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.106-109
    • /
    • 2013
  • It is desirable and advantageous to feed parallel propulsion with induction motors by a single voltage source inverter. However, effects of deviation of the wheel diameters on motor current, rotor speed and torque should be also considered for parallel operation. In order to understand the behavior and characteristics, a simple simulation model is developed by using a commercial Matlab Simulink. From the results, it is clear to manage the diameter deviation of the wheels which are connected to traction motors.

전기철도 급전시스템 전력품질 향상을 위한 새로운 보상장치 검토 (Analysis on New Equipment for countermeasure of Power Quality in Electric Railway)

  • 김주락;한문섭;이장무;정호성;김희중
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1396-1401
    • /
    • 2004
  • This paper proposes analysis on new equipment for power quality in electric railway. The Proposed equipment consists of series inverter and parallel inverter. Each inverter is connected by capacitor as de link. This structure can be compensated for active and reactive power in catenary through transformer.

  • PDF

부하불평형 해소를 위한 축소형 보상설비 개발 (Development of the down-scaled compensator for the solution of unbalanced load)

  • 김주락;한문섭;이장무;정호성;박현준;강문호;김정훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.649-654
    • /
    • 2005
  • This paper proposes analysis on new equipment for power quality in electric railway. The proposed equipment consists of series inverter and parallel inverter. Each inverter is connected by capacitor as dc link. This structure can be compensated for active and reactive power in catenary through transformer.

  • PDF

A New Parallel Hybrid Filter Configuration Minimizing Active Filter Size

  • Park, Sukin;Sung, Jeong-hyoun;Nam, Kwanghee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.894-897
    • /
    • 1998
  • A conventional parallel hybrid active filter has an inherent problem of large current ratings of devices used in inverter. In general, this problem has been solved by adjusting turn ratio of a matching transformer. However, making the transformer with high turn ratio may be not available for high power system due to its requirement for high voltage insulation. In this paper, a new configuration is proposed for parallel hybrid active filter. In the proposed hybrid active filter, the active filter is connected to the passive filter inductor in parallel through a matching transformer for the aim of reducing the size of inverter. Through computer simulations, we have shown the outstanding performances of the proposed topology.

  • PDF

다중 인버터 구동 고속전철 시스템의 IPMSM 파라미터 변동에 따른 운전 특성 고찰 (Investigation of the IPMSM Parameter Variation Effect to the System Operation Characteristics of the Multi Inverter Driven High Speed Train System)

  • 박동규;진강환;장진영;김성제;김윤호
    • 전기학회논문지P
    • /
    • 제60권4호
    • /
    • pp.193-199
    • /
    • 2011
  • The next generation domestic high speed railway system is a power distributed type and uses vector control method for motor speed control. Nowadays, inverter driven induction motor system is widely used. However, recently PMSM drives are deeply considered as a alternative candidate instead of an induction motor driven system due to their advantages in efficiency, noise reduction and maintenance. The next-generation high-speed train is composed of 2 converter units, 4 inverter units, and 4 Traction Motor units. Each motor is connected to the inverter directly. In this paper, the effects of IPMSM parameter variation to the system operation characteristics of the multi inverter driven high speed train system are investigated. The parallel connected inverter input-output characteristics are analyzed to the parameter mismatches of the IPMSM in 1C1M control using Matlab/Simulink, then the reliability of the simulation results are verified through experimental results.

단위 인버터 병렬운전에 의한 발전소 해수펌크 적용 (Studies on the Application of Unit-inverter Parallel Operation to Sea-water Lift Pump in Power Plant)

  • 김수열;류홍우
    • 전력전자학회논문지
    • /
    • 제3권1호
    • /
    • pp.1-7
    • /
    • 1998
  • 발전설비의 대형화로 인하여 전력절감 문제가 크게 대두되었고, 팬이나 펌프를 부하 변화에 따라 속도제어하므로써 전기 에너지를 절약 할 수 있다. 1MVA급 단위 인버터 2대를 병렬 운전하여 대용량 2MVA GTO 인버터를 구현하였으며, 단위 인버터의 병렬 운전은 2대의 출력변압기 2차측 결선을 직렬 연결하여 구현하였다. 개발된 시스템은 제어반, 정류기반, 2대의 인버터반으로 구성되어 있으며, 이 시스템은 한국전력공사 성인천복합화력발전처 해수펌프 구동 유도전동기(6.6KV 1500KW)에 적용되어 전력절감에 기여하고 있다. 또 단위 인버터가 상호 180$^{\circ}$위상차를 갖도록 병렬 운전하므로써 고조파 성분을 저감시키면서 대용량을 구현하였다.